MN761991.30
EC HPLC guard column (analytical), NUCLEODUR C18 Gravity-SB, 3 µm, 4x3 mm
Special offer
Add to Cart
Recommended application(s)
Guard column, ideal protection for your main column, HPLC
Storage temperature
RT
Scope of delivery
3x analytical HPLC guard columns
Hazardous material
No
Method
HPLC, analytical
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR C18 Gravity-SB
USP listing
L1
Surface chemistry
Monomeric octadecyl (C18, ODS) modification with bulky side chains, distinct polar selectivity
Mode
Reversed phase (RP)
Type
EC HPLC guard column (analytical)
Hardware
Stainless steel
Column length
4 mm
Column inner diameter
3 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
3 µm
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
13.0 %
pH stability
1.0–9.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
600 bar
MN761992.20
EC HPLC guard column (analytical), NUCLEODUR C18 Gravity-SB, 5 µm, 4x2 mm
Special offer
Add to Cart
Recommended application(s)
Guard column, ideal protection for your main column, HPLC
Storage temperature
RT
Scope of delivery
3x analytical HPLC guard columns
Hazardous material
No
Method
HPLC, analytical
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR C18 Gravity-SB
USP listing
L1
Surface chemistry
Monomeric octadecyl (C18, ODS) modification with bulky side chains, distinct polar selectivity
Mode
Reversed phase (RP)
Type
EC HPLC guard column (analytical)
Hardware
Stainless steel
Column length
4 mm
Column inner diameter
2 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
5 µm
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
13.0 %
pH stability
1.0–9.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
600 bar
MN761992.30
EC HPLC guard column (analytical), NUCLEODUR C18 Gravity-SB, 5 µm, 4x3 mm
Special offer
Add to Cart
Recommended application(s)
Guard column, ideal protection for your main column, HPLC
Storage temperature
RT
Scope of delivery
3x analytical HPLC guard columns
Hazardous material
No
Method
HPLC, analytical
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR C18 Gravity-SB
USP listing
L1
Surface chemistry
Monomeric octadecyl (C18, ODS) modification with bulky side chains, distinct polar selectivity
Mode
Reversed phase (RP)
Type
EC HPLC guard column (analytical)
Hardware
Stainless steel
Column length
4 mm
Column inner diameter
3 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
5 µm
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
13.0 %
pH stability
1.0–9.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
600 bar
MN762090.160
VP HPLC guard column (preparative), NUCLEODUR C18 ec, 10x16 mm
Special offer
Add to Cart
Recommended application(s)
For examples please see analytical NUCLEODUR C18 ec, RP applications (preparative)
Storage temperature
RT
Scope of delivery
2x preparative HPLC guard column
Hazardous material
No
Method
HPLC, preparative
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR C18 ec
USP listing
L1
Surface chemistry
Medium density monomeric octadecyl (C18, ODS) modification
Mode
Reversed phase (RP)
Type
VP HPLC guard column (preparative)
Hardware
Stainless steel
Column length
10 mm
Column inner diameter
16 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
Proprietary
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
17.5 %
pH stability
1.0–9.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
400 bar
MN762090.80
VP HPLC guard column (preparative), NUCLEODUR C18 ec, 10x8 mm
Special offer
Add to Cart
Recommended application(s)
For examples please see analytical NUCLEODUR C18 ec, RP applications (preparative)
Storage temperature
RT
Scope of delivery
2x preparative HPLC guard column
Hazardous material
No
Method
HPLC, preparative
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR C18 ec
USP listing
L1
Surface chemistry
Medium density monomeric octadecyl (C18, ODS) modification
Mode
Reversed phase (RP)
Type
VP HPLC guard column (preparative)
Hardware
Stainless steel
Column length
10 mm
Column inner diameter
8 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
Proprietary
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
17.5 %
pH stability
1.0–9.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
400 bar
MN762092.160
VP HPLC guard column (preparative), NUCLEODUR C8 ec, 10x16 mm
Special offer
Add to Cart
Recommended application(s)
For examples please see analytical NUCLEODUR C8 ec, RP applications (preparative)
Storage temperature
RT
Scope of delivery
2x preparative HPLC guard column
Hazardous material
No
Method
HPLC, preparative
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR 100-5 C8 ec
USP listing
L7
Surface chemistry
Medium density monomeric octyl (C8, MOS) modification
Mode
Reversed phase (RP)
Type
VP HPLC guard column (preparative)
Hardware
Stainless steel
Column length
10 mm
Column inner diameter
16 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
Proprietary
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
10.5 %
pH stability
1.0–9.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
400 bar
MN762092.80
VP HPLC guard column (preparative), NUCLEODUR C8 ec, 10x8 mm
Special offer
Add to Cart
Recommended application(s)
For examples please see analytical NUCLEODUR C8 ec, RP applications (preparative)
Storage temperature
RT
Scope of delivery
2x preparative HPLC guard column
Hazardous material
No
Method
HPLC, preparative
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR 100-5 C8 ec
USP listing
L7
Surface chemistry
Medium density monomeric octyl (C8, MOS) modification
Mode
Reversed phase (RP)
Type
VP HPLC guard column (preparative)
Hardware
Stainless steel
Column length
10 mm
Column inner diameter
8 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
Proprietary
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
10.5 %
pH stability
1.0–9.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
400 bar
MN762094.160
VP HPLC guard column (preparative), NUCLEODUR, 10x16 mm
Special offer
Add to Cart
Recommended application(s)
For all NUCLEODUR and NUCLEOSIL normal phases, ideal protection for your main column, Polar universal guard column cartridge
Storage temperature
RT
Scope of delivery
2x preparative HPLC guard column
Hazardous material
No
Method
HPLC, preparative
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR
USP listing
L3
Surface chemistry
Unmodified silica gel (SiOH)
Mode
Normal phase (NP)
Type
VP HPLC guard column (preparative)
Hardware
Stainless steel
Column length
10 mm
Column inner diameter
16 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
Proprietary
Eluent in HPLC column
n-heptane
Endcapped
No
Carbon content
Not available or not applicable
pH stability
2.0–8.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
400 bar
MN762094.80
VP HPLC guard column (preparative), NUCLEODUR, 10x8 mm
Special offer
Add to Cart
Recommended application(s)
For all NUCLEODUR and NUCLEOSIL normal phases, ideal protection for your main column, Polar universal guard column cartridge
Storage temperature
RT
Scope of delivery
2x preparative HPLC guard column
Hazardous material
No
Method
HPLC, preparative
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR
USP listing
L3
Surface chemistry
Unmodified silica gel (SiOH)
Mode
Normal phase (NP)
Type
VP HPLC guard column (preparative)
Hardware
Stainless steel
Column length
10 mm
Column inner diameter
8 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
Proprietary
Eluent in HPLC column
n-heptane
Endcapped
No
Carbon content
Not available or not applicable
pH stability
2.0–8.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
400 bar
MN762097.160
VP HPLC guard column (preparative), NUCLEODUR C8 Gravity, 10x16 mm
Special offer
Add to Cart
Recommended application(s)
For examples please see analytical NUCLEODUR C8 Gravity, RP applications (preparative)
Storage temperature
RT
Scope of delivery
2x preparative HPLC guard column
Hazardous material
No
Method
HPLC, preparative
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR C8 Gravity
USP listing
L7
Surface chemistry
Base deactivated (BDS), High density monomeric octyl (C8, MOS) modification
Mode
Reversed phase (RP)
Type
VP HPLC guard column (preparative)
Hardware
Stainless steel
Column length
10 mm
Column inner diameter
16 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
Proprietary
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
11.0 %
pH stability
1.0–11.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
400 bar