+852-3069 6950
css@gugent.com.hk
 

Stainless steel HPLC columns for analytical or preparative applictions from MACHEREY‑NAGEL are a great choice for your daily labwork.

* NUCLEOSIL HPLC phases have gained wide acceptance as routine chromatographic packings for very different fields of modern chromatography. It is one of the first spherical silicas used in HPLC and is an absolutely reliable choice for routine analyses.

* NUCLEODUR as a state-of-the-art silica is the ideal base material for modern HPLC phases. It is the result of MACHEREY-NAGEL's pioneering research in chromatography for almost 50 years. NUCLEODUR HPLC columns with 1.8 µm particle size for increased separation efficiency are used for UHPLC applications.

* Due to core-shell technology NUCLEOSHELL columns provide highly efficient separation results with a comparably lower back pressure to fully porous materials.

Catalog No. Product Net Price
MN761991.30 EC HPLC guard column (analytical), NUCLEODUR C18 Gravity-SB, 3 µm, 4x3 mm Special offer 
Add to Cart
  • Recommended application(s)
  • Guard column, ideal protection for your main column, HPLC
  • Storage temperature
  • RT
  • Scope of delivery
  • 3x analytical HPLC guard columns
  • Hazardous material
  • No
  • Method
  • HPLC, analytical
  • Brand
  • NUCLEODUR
  • Base material
  • NUCLEODUR - high purity silica
  • Phase
  • NUCLEODUR C18 Gravity-SB
  • USP listing
  • L1
  • Surface chemistry
  • Monomeric octadecyl (C18, ODS) modification with bulky side chains, distinct polar selectivity
  • Mode
  • Reversed phase (RP)
  • Type
  • EC HPLC guard column (analytical)
  • Hardware
  • Stainless steel
  • Column length
  • 4 mm
  • Column inner diameter
  • 3 mm
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • 3 µm
  • Eluent in HPLC column
  • Acetonitrile – water
  • Endcapped
  • Yes
  • Carbon content
  • 13.0 %
  • pH stability
  • 1.0–9.0
  • Pore size
  • 110 Å
  • Specific surface according to BET
  • 340 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 600 bar
MN761992.20 EC HPLC guard column (analytical), NUCLEODUR C18 Gravity-SB, 5 µm, 4x2 mm Special offer 
Add to Cart
  • Recommended application(s)
  • Guard column, ideal protection for your main column, HPLC
  • Storage temperature
  • RT
  • Scope of delivery
  • 3x analytical HPLC guard columns
  • Hazardous material
  • No
  • Method
  • HPLC, analytical
  • Brand
  • NUCLEODUR
  • Base material
  • NUCLEODUR - high purity silica
  • Phase
  • NUCLEODUR C18 Gravity-SB
  • USP listing
  • L1
  • Surface chemistry
  • Monomeric octadecyl (C18, ODS) modification with bulky side chains, distinct polar selectivity
  • Mode
  • Reversed phase (RP)
  • Type
  • EC HPLC guard column (analytical)
  • Hardware
  • Stainless steel
  • Column length
  • 4 mm
  • Column inner diameter
  • 2 mm
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • 5 µm
  • Eluent in HPLC column
  • Acetonitrile – water
  • Endcapped
  • Yes
  • Carbon content
  • 13.0 %
  • pH stability
  • 1.0–9.0
  • Pore size
  • 110 Å
  • Specific surface according to BET
  • 340 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 600 bar
MN761992.30 EC HPLC guard column (analytical), NUCLEODUR C18 Gravity-SB, 5 µm, 4x3 mm Special offer 
Add to Cart
  • Recommended application(s)
  • Guard column, ideal protection for your main column, HPLC
  • Storage temperature
  • RT
  • Scope of delivery
  • 3x analytical HPLC guard columns
  • Hazardous material
  • No
  • Method
  • HPLC, analytical
  • Brand
  • NUCLEODUR
  • Base material
  • NUCLEODUR - high purity silica
  • Phase
  • NUCLEODUR C18 Gravity-SB
  • USP listing
  • L1
  • Surface chemistry
  • Monomeric octadecyl (C18, ODS) modification with bulky side chains, distinct polar selectivity
  • Mode
  • Reversed phase (RP)
  • Type
  • EC HPLC guard column (analytical)
  • Hardware
  • Stainless steel
  • Column length
  • 4 mm
  • Column inner diameter
  • 3 mm
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • 5 µm
  • Eluent in HPLC column
  • Acetonitrile – water
  • Endcapped
  • Yes
  • Carbon content
  • 13.0 %
  • pH stability
  • 1.0–9.0
  • Pore size
  • 110 Å
  • Specific surface according to BET
  • 340 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 600 bar
MN762090.160 VP HPLC guard column (preparative), NUCLEODUR C18 ec, 10x16 mm Special offer 
Add to Cart
  • Recommended application(s)
  • For examples please see analytical NUCLEODUR C18 ec, RP applications (preparative)
  • Storage temperature
  • RT
  • Scope of delivery
  • 2x preparative HPLC guard column
  • Hazardous material
  • No
  • Method
  • HPLC, preparative
  • Brand
  • NUCLEODUR
  • Base material
  • NUCLEODUR - high purity silica
  • Phase
  • NUCLEODUR C18 ec
  • USP listing
  • L1
  • Surface chemistry
  • Medium density monomeric octadecyl (C18, ODS) modification
  • Mode
  • Reversed phase (RP)
  • Type
  • VP HPLC guard column (preparative)
  • Hardware
  • Stainless steel
  • Column length
  • 10 mm
  • Column inner diameter
  • 16 mm
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • Proprietary
  • Eluent in HPLC column
  • Acetonitrile – water
  • Endcapped
  • Yes
  • Carbon content
  • 17.5 %
  • pH stability
  • 1.0–9.0
  • Pore size
  • 110 Å
  • Specific surface according to BET
  • 340 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 400 bar
MN762090.80 VP HPLC guard column (preparative), NUCLEODUR C18 ec, 10x8 mm Special offer 
Add to Cart
  • Recommended application(s)
  • For examples please see analytical NUCLEODUR C18 ec, RP applications (preparative)
  • Storage temperature
  • RT
  • Scope of delivery
  • 2x preparative HPLC guard column
  • Hazardous material
  • No
  • Method
  • HPLC, preparative
  • Brand
  • NUCLEODUR
  • Base material
  • NUCLEODUR - high purity silica
  • Phase
  • NUCLEODUR C18 ec
  • USP listing
  • L1
  • Surface chemistry
  • Medium density monomeric octadecyl (C18, ODS) modification
  • Mode
  • Reversed phase (RP)
  • Type
  • VP HPLC guard column (preparative)
  • Hardware
  • Stainless steel
  • Column length
  • 10 mm
  • Column inner diameter
  • 8 mm
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • Proprietary
  • Eluent in HPLC column
  • Acetonitrile – water
  • Endcapped
  • Yes
  • Carbon content
  • 17.5 %
  • pH stability
  • 1.0–9.0
  • Pore size
  • 110 Å
  • Specific surface according to BET
  • 340 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 400 bar
MN762092.160 VP HPLC guard column (preparative), NUCLEODUR C8 ec, 10x16 mm Special offer 
Add to Cart
  • Recommended application(s)
  • For examples please see analytical NUCLEODUR C8 ec, RP applications (preparative)
  • Storage temperature
  • RT
  • Scope of delivery
  • 2x preparative HPLC guard column
  • Hazardous material
  • No
  • Method
  • HPLC, preparative
  • Brand
  • NUCLEODUR
  • Base material
  • NUCLEODUR - high purity silica
  • Phase
  • NUCLEODUR 100-5 C8 ec
  • USP listing
  • L7
  • Surface chemistry
  • Medium density monomeric octyl (C8, MOS) modification
  • Mode
  • Reversed phase (RP)
  • Type
  • VP HPLC guard column (preparative)
  • Hardware
  • Stainless steel
  • Column length
  • 10 mm
  • Column inner diameter
  • 16 mm
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • Proprietary
  • Eluent in HPLC column
  • Acetonitrile – water
  • Endcapped
  • Yes
  • Carbon content
  • 10.5 %
  • pH stability
  • 1.0–9.0
  • Pore size
  • 110 Å
  • Specific surface according to BET
  • 340 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 400 bar
MN762092.80 VP HPLC guard column (preparative), NUCLEODUR C8 ec, 10x8 mm Special offer 
Add to Cart
  • Recommended application(s)
  • For examples please see analytical NUCLEODUR C8 ec, RP applications (preparative)
  • Storage temperature
  • RT
  • Scope of delivery
  • 2x preparative HPLC guard column
  • Hazardous material
  • No
  • Method
  • HPLC, preparative
  • Brand
  • NUCLEODUR
  • Base material
  • NUCLEODUR - high purity silica
  • Phase
  • NUCLEODUR 100-5 C8 ec
  • USP listing
  • L7
  • Surface chemistry
  • Medium density monomeric octyl (C8, MOS) modification
  • Mode
  • Reversed phase (RP)
  • Type
  • VP HPLC guard column (preparative)
  • Hardware
  • Stainless steel
  • Column length
  • 10 mm
  • Column inner diameter
  • 8 mm
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • Proprietary
  • Eluent in HPLC column
  • Acetonitrile – water
  • Endcapped
  • Yes
  • Carbon content
  • 10.5 %
  • pH stability
  • 1.0–9.0
  • Pore size
  • 110 Å
  • Specific surface according to BET
  • 340 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 400 bar
MN762094.160 VP HPLC guard column (preparative), NUCLEODUR, 10x16 mm Special offer 
Add to Cart
  • Recommended application(s)
  • For all NUCLEODUR and NUCLEOSIL normal phases, ideal protection for your main column, Polar universal guard column cartridge
  • Storage temperature
  • RT
  • Scope of delivery
  • 2x preparative HPLC guard column
  • Hazardous material
  • No
  • Method
  • HPLC, preparative
  • Brand
  • NUCLEODUR
  • Base material
  • NUCLEODUR - high purity silica
  • Phase
  • NUCLEODUR
  • USP listing
  • L3
  • Surface chemistry
  • Unmodified silica gel (SiOH)
  • Mode
  • Normal phase (NP)
  • Type
  • VP HPLC guard column (preparative)
  • Hardware
  • Stainless steel
  • Column length
  • 10 mm
  • Column inner diameter
  • 16 mm
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • Proprietary
  • Eluent in HPLC column
  • n-heptane
  • Endcapped
  • No
  • Carbon content
  • Not available or not applicable
  • pH stability
  • 2.0–8.0
  • Pore size
  • 110 Å
  • Specific surface according to BET
  • 340 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 400 bar
MN762094.80 VP HPLC guard column (preparative), NUCLEODUR, 10x8 mm Special offer 
Add to Cart
  • Recommended application(s)
  • For all NUCLEODUR and NUCLEOSIL normal phases, ideal protection for your main column, Polar universal guard column cartridge
  • Storage temperature
  • RT
  • Scope of delivery
  • 2x preparative HPLC guard column
  • Hazardous material
  • No
  • Method
  • HPLC, preparative
  • Brand
  • NUCLEODUR
  • Base material
  • NUCLEODUR - high purity silica
  • Phase
  • NUCLEODUR
  • USP listing
  • L3
  • Surface chemistry
  • Unmodified silica gel (SiOH)
  • Mode
  • Normal phase (NP)
  • Type
  • VP HPLC guard column (preparative)
  • Hardware
  • Stainless steel
  • Column length
  • 10 mm
  • Column inner diameter
  • 8 mm
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • Proprietary
  • Eluent in HPLC column
  • n-heptane
  • Endcapped
  • No
  • Carbon content
  • Not available or not applicable
  • pH stability
  • 2.0–8.0
  • Pore size
  • 110 Å
  • Specific surface according to BET
  • 340 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 400 bar
MN762097.160 VP HPLC guard column (preparative), NUCLEODUR C8 Gravity, 10x16 mm Special offer 
Add to Cart
  • Recommended application(s)
  • For examples please see analytical NUCLEODUR C8 Gravity, RP applications (preparative)
  • Storage temperature
  • RT
  • Scope of delivery
  • 2x preparative HPLC guard column
  • Hazardous material
  • No
  • Method
  • HPLC, preparative
  • Brand
  • NUCLEODUR
  • Base material
  • NUCLEODUR - high purity silica
  • Phase
  • NUCLEODUR C8 Gravity
  • USP listing
  • L7
  • Surface chemistry
  • Base deactivated (BDS), High density monomeric octyl (C8, MOS) modification
  • Mode
  • Reversed phase (RP)
  • Type
  • VP HPLC guard column (preparative)
  • Hardware
  • Stainless steel
  • Column length
  • 10 mm
  • Column inner diameter
  • 16 mm
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • Proprietary
  • Eluent in HPLC column
  • Acetonitrile – water
  • Endcapped
  • Yes
  • Carbon content
  • 11.0 %
  • pH stability
  • 1.0–11.0
  • Pore size
  • 110 Å
  • Specific surface according to BET
  • 340 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 400 bar

Overview

High performance liquid chromatography (HPLC) is part of liquid chromatographic separating processes of substance mixtures and their analysis. At the beginning the technique was also called high pressure liquid chromatography due to the high back pressure of the column. HPLC offers qualitative (identification of substances) and quantitative (concentration determination) analysis by comparison with standard substances. The term HPLC was introduced in the 1970s, for the delineation of the high-performance method to the in the 1930s developed column liquid chromatography (column chromatography). At the beginning of the 21st century the HPLC was complemented by the even more efficient UHPLC (ultra high performance liquid chromatography). Hereby even higher pressures (> 400 bar) result in shorter analysis time and enhanced efficiency enabling a higher sample throughput with smaller sample volumes.


Detailed information of the particular properties of the high-purity silica phases NUCLEODUR, the established standard silica NUCLEOSIL and the modern Core-Shell material NUCLEOSHELL as well as phases for special separations can be found at the equivalent HPLC- and UHPLC-columns.


Each MACHEREY‑NAGEL HPLC / UHPLC column is individually tested according to the most important characteristic parameters in quality control and the results are documented in a certificate of analysis.



Resources