Shimadzu has been developing UV-Vis spectrophotometers for more than 60 years, and continues to manufacture instruments that meet scientists' needs for ruggedness, ease of use, validation and applications. Our current lineup features the technologically advanced double-beam UV-1900i, which enhances usability, performance, and compliance, the introductory research-grade UV-2600i, with an extended range to 1400nm, and the double monochromator UV-2700i, which is capable of high Abs measurements. These compact systems are equipped with proprietary low-ray-ligh gratings, offer USB connectivity, and come with the full-featured UVProbe software.
The research-grade UV-Vis-NIR systems, UV-3600i Plus and SolidSpec-3700i, incorporate three detectors, which help to achieve excellent sensitivity during transmittance and reflectance, even in the switchover range, while significantly reducing noise.
Additional models include the versatile single-beam UV-1280 and the low-maintenance, micro-volume BioSpec-nano. Designed for the modern life science laboratory, the BioSpec-nano provides quick, easy nucleic acid quantitation and protein analysis with 1µL to 2µL samples.
Catalog No. | Product | Net Price | |||
---|---|---|---|---|---|
220-92910-17 | Semi-Micro Cell, 10 mm, Quartz, W/ PTFE | 693 |
Add to Cart
|
||
220-92910-53 | Macro Cell, 10 mm, Quartz, W/PTFE Stopper | 541 |
Add to Cart
|
||
220-92910-55 | Macro Cell, 10 mm, Quartz | 283 |
Add to Cart
|
||
220-92910-37 | Cell, Clyinder W/ Stopper 100 Mm, Quartz | 318 |
Add to Cart
|
||
220-92910-78 | Ultra Micro Flow Cell,10 mm,80 Microliter | 1215 |
Add to Cart
|
||
220-92910-82 | Macro Cell W/ PTFE Stopper, 10 mm, Quartz | 499 |
Add to Cart
|
||
220-92910-83 | 1.25Mm Base Semi-Micro Cell W/ PTFE Lid, Quartz | 322 |
Add to Cart
|
||
220-92910-84 | Semi-Micro Cell W/ PTFE Stopper, Quartz | 520 |
Add to Cart
|
||
220-92910-64 | Short Path (1 mm)Macro Flow-Through Cell | 922 |
Add to Cart
|
||
220-92910-41 | Cell Short Path 1 Mm, Quartz | 158 |
Add to Cart
|
||
Sample | Analytical form and analytical condition | Accessory | ||
---|---|---|---|---|
Smooth Surface Samples* | Transmittance Measurement | Less than 3 mm thick | Standard compartments+Film Holder, Cell Type Sample Holder, Glass/Film Holder for Standard Sample Compartment | |
More than 3 mm thick | Integrating Sphere Attachment (ISR-2600, ISR-2600Plus, ISR-603) | |||
Requires a large integrating sphere (due to ISO compliance and other reasons). | Integrating Sphere Attachment, 150 mm Dia. (ISR-1503, ISR-1503F) | |||
Large sample size (over 100 mm square) | Large-Sample Compartment (MPC-2600A/603A or SolidSpec-3700) Glass Sample Holder for MPC series/SolidSpec | |||
Reflectance Measurement | Relative Specular Reflectance Measurement | Normal measurement | Specular Reflectance Measurement Attachment (5° incident angle) | |
Large sample size (over 100 mm square) | SolidSpec-3700 + Large Specular Reflectance Measurement Attachment (5° incident angle) | |||
Absolute Specular Reflectance Measurement | 5゚ incident angle measurement | Absolute Specular Reflectance Attachment (ASR-3105) (Requires a Large-Sample Compartment and BIS-3100/3700/603 Sample Base Plate Integrating Sphere Set separately). | ||
12/30/45゚ incident angle measurement | Absolute Specular Reflectance Attachment (ASR-3112, ASR-3130, ASR-3145) (Requires a Large-Sample Compartment, BIS-3100/3700/603 Sample Base Plate Integrating Sphere Set, and polarizer assembly separately.) | |||
Variable Angle Measurement Unit | Variable Angle Measurement Unit (Requires large-sample compartment and polarizer assembly separately.) | |||
Relative Diffuse Reflectance Measurement | Normal measurement | Integrating Sphere Attachment (ISR-2600, ISR-2600Plus, ISR-603) | ||
Requires a large integrating sphere (due to ISO compliance and other reasons). | Integrating Sphere Attachment, 150 mm Dia. (ISR-1503, ISR-1503F) | |||
Large sample size (over 100 mm square) | Large-Sample Compartment (MPC-2600A/603A, or SolidSpec-3700) | |||
Rough Surface Sample** | Transmittance Measurement | Normal measurement | Integrating Sphere Attachment (ISR-2600, ISR-2600Plus, ISR-603) | |
Requires a large integrating sphere (due to ISO compliance and other reasons). | Integrating Sphere Attachment, 150 mm Dia. (ISR-1503, ISR-1503F) | |||
Large sample size (over 100 mm square) | Large-Sample Compartment (MPC-2600A/603A, or SolidSpec-3700) | |||
Reflectance Measurement | Relative Diffuse Reflectance Measurement | Normal measurement | Integrating Sphere Attachment (ISR-2600, ISR-2600Plus, ISR-603) | |
Requires a large integrating sphere (due to ISO compliance and other reasons). | Integrating Sphere Attachment, 150 mm Dia. (ISR-1503, ISR-1503F) | |||
Large sample size (over 100 mm square) | Large-Sample Compartment (MPC-2600A/603A, or SolidSpec-3700) | |||
Absolute Diffuse Reflectance Measurement | Consult your Shimadzu representative. (Depends on the sample. A method using conversion from the mirror reflectance, for instance, is available.) | |||
Large sample size (over 100 mm square) | Large-Sample Compartment (MPC-2600A/603A, or SolidSpec-3700) | |||
Small sample size (below 5 mm square) | Micro Sample Holder + Micro Beam Lens Unit |