MN762097.80
VP HPLC guard column (preparative), NUCLEODUR C8 Gravity, 10x8 mm
Special offer
Add to Cart
Recommended application(s)
For examples please see analytical NUCLEODUR C8 Gravity, RP applications (preparative)
Storage temperature
RT
Scope of delivery
2x preparative HPLC guard column
Hazardous material
No
Method
HPLC, preparative
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR C8 Gravity
USP listing
L7
Surface chemistry
Base deactivated (BDS), High density monomeric octyl (C8, MOS) modification
Mode
Reversed phase (RP)
Type
VP HPLC guard column (preparative)
Hardware
Stainless steel
Column length
10 mm
Column inner diameter
8 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
Proprietary
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
11.0 %
pH stability
1.0–11.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
400 bar
MN762160.160
VP HPLC guard column (preparative), NUCLEODUR C18 Gravity, 10x16 mm
Special offer
Add to Cart
Recommended application(s)
For examples please see analytical NUCLEODUR C18 Gravity, RP applications (preparative)
Storage temperature
RT
Scope of delivery
2x preparative HPLC guard column
Hazardous material
No
Method
HPLC, preparative
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR C18 Gravity
USP listing
L1
Surface chemistry
Base deactivated (BDS), High density octadecyl (C18, ODS) modification
Mode
Reversed phase (RP)
Type
VP HPLC guard column (preparative)
Hardware
Stainless steel
Column length
10 mm
Column inner diameter
16 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
Proprietary
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
18.0 %
pH stability
1.0–11.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
400 bar
MN762160.80
VP HPLC guard column (preparative), NUCLEODUR C18 Gravity, 10x8 mm
Special offer
Add to Cart
Recommended application(s)
For examples please see analytical NUCLEODUR C18 Gravity, RP applications (preparative)
Storage temperature
RT
Scope of delivery
2x preparative HPLC guard column
Hazardous material
No
Method
HPLC, preparative
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR C18 Gravity
USP listing
L1
Surface chemistry
Base deactivated (BDS), High density octadecyl (C18, ODS) modification
Mode
Reversed phase (RP)
Type
VP HPLC guard column (preparative)
Hardware
Stainless steel
Column length
10 mm
Column inner diameter
8 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
Proprietary
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
18.0 %
pH stability
1.0–11.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
400 bar
MN762214.160
VP HPLC guard column (preparative), NUCLEODUR PFP, 10x16 mm
Special offer
Add to Cart
Recommended application(s)
For examples please see analytical NUCLEODUR PFP, RP applications (preparative)
Storage temperature
RT
Scope of delivery
2x preparative HPLC guard column
Hazardous material
No
Method
HPLC, preparative
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR PFP
USP listing
L43
Surface chemistry
Pentafluorophenylpropyl (PFP) modification
Mode
Reversed phase (RP)
Type
VP HPLC guard column (preparative)
Hardware
Stainless steel
Column length
10 mm
Column inner diameter
16 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
Proprietary
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
8.0 %
pH stability
1.0–9.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
400 bar
MN762224.160
VP HPLC guard column (preparative), NUCLEODUR PolarTec, 10x16 mm
Special offer
Add to Cart
Recommended application(s)
For examples please see analytical NUCLEODUR PolarTec, RP applications (preparative)
Storage temperature
RT
Scope of delivery
2x preparative HPLC guard column
Hazardous material
No
Method
HPLC, preparative
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR PolarTec
USP listing
L1, L60
Surface chemistry
Octadecyl phase (C18, ODS) modification, with embedded polar group (PEG)
Mode
Reversed phase (RP)
Type
VP HPLC guard column (preparative)
Hardware
Stainless steel
Column length
10 mm
Column inner diameter
16 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
Proprietary
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
17.0 %
pH stability
1.0–9.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
400 bar
MN762224.80
VP HPLC guard column (preparative), NUCLEODUR PolarTec, 10x8 mm
Special offer
Add to Cart
Recommended application(s)
For examples please see analytical NUCLEODUR PolarTec, RP applications (preparative)
Storage temperature
RT
Scope of delivery
2x preparative HPLC guard column
Hazardous material
No
Method
HPLC, preparative
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR PolarTec
USP listing
L1, L60
Surface chemistry
Octadecyl phase (C18, ODS) modification, with embedded polar group (PEG)
Mode
Reversed phase (RP)
Type
VP HPLC guard column (preparative)
Hardware
Stainless steel
Column length
10 mm
Column inner diameter
8 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
Proprietary
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
17.0 %
pH stability
1.0–9.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
400 bar
MN762234.160
VP HPLC guard column (preparative), NUCLEODUR Phenyl-Hexyl, 10x16 mm
Special offer
Add to Cart
Recommended application(s)
For examples please see analytical NUCLEODUR Phenyl-Hexyl, RP applications (preparative)
Storage temperature
RT
Scope of delivery
2x preparative HPLC guard column
Hazardous material
No
Method
HPLC, preparative
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR Phenyl-Hexyl
USP listing
L11
Surface chemistry
Phenylhexyl modification
Mode
Reversed phase (RP)
Type
VP HPLC guard column (preparative)
Hardware
Stainless steel
Column length
10 mm
Column inner diameter
16 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
Proprietary
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
10.0 %
pH stability
1.0–10.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
400 bar
MN762291.160
VP HPLC guard column (preparative), NUCLEODUR C18 Pyramid, 10x16 mm
Special offer
Add to Cart
Recommended application(s)
For examples please see analytical NUCLEODUR C18 Pyramid, RP applications (preparative)
Storage temperature
RT
Scope of delivery
2x preparative HPLC guard column
Hazardous material
No
Method
HPLC, preparative
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR C18 Pyramid
USP listing
L1
Surface chemistry
Octadecyl (C18, ODS) modification, Polar endcapping
Mode
Reversed phase (RP)
Type
VP HPLC guard column (preparative)
Hardware
Stainless steel
Column length
10 mm
Column inner diameter
16 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
Proprietary
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
14.0 %
pH stability
1.0–9.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
400 bar
MN762291.80
VP HPLC guard column (preparative), NUCLEODUR C18 Pyramid, 10x8 mm
Special offer
Add to Cart
Recommended application(s)
For examples please see analytical NUCLEODUR C18 Pyramid, RP applications (preparative)
Storage temperature
RT
Scope of delivery
2x preparative HPLC guard column
Hazardous material
No
Method
HPLC, preparative
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR C18 Pyramid
USP listing
L1
Surface chemistry
Octadecyl (C18, ODS) modification, Polar endcapping
Mode
Reversed phase (RP)
Type
VP HPLC guard column (preparative)
Hardware
Stainless steel
Column length
10 mm
Column inner diameter
8 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
Proprietary
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
14.0 %
pH stability
1.0–9.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
400 bar
MN762354.160
VP HPLC guard column (preparative), NUCLEODUR C18 Gravity-SB, 10x16 mm
Special offer
Add to Cart
Recommended application(s)
For examples please see analytical NUCLEODUR C18 Gravity-SB, RP applications (preparative)
Storage temperature
RT
Scope of delivery
2x preparative HPLC guard column
Hazardous material
No
Method
HPLC, preparative
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR C18 Gravity-SB
USP listing
L1
Surface chemistry
Monomeric octadecyl (C18, ODS) modification with bulky side chains, distinct polar selectivity
Mode
Reversed phase (RP)
Type
VP HPLC guard column (preparative)
Hardware
Stainless steel
Column length
10 mm
Column inner diameter
16 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
Proprietary
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
13.0 %
pH stability
1.0–9.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
400 bar