MN761951.30
EC HPLC guard column (analytical), NUCLEODUR 100-3 NH2-RP, 3 µm, 4x3 mm
Special offer
Add to Cart
Recommended application(s)
Guard column, ideal protection for your main column, HPLC
Storage temperature
RT
Scope of delivery
3x analytical HPLC guard columns
Hazardous material
No
Method
HPLC, analytical
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR 100-3 NH2-RP
USP listing
L8
Surface chemistry
Aminopropyl (NH2) modification
Mode
Multi-mode (NP and RP), Reversed phase (RP)
Type
EC HPLC guard column (analytical)
Hardware
Stainless steel
Column length
4 mm
Column inner diameter
3 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
3 µm
Eluent in HPLC column
Acetonitrile – water
Endcapped
No
Carbon content
2.5 %
pH stability
2.0–8.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
600 bar
MN761952.30
EC HPLC guard column (analytical), NUCLEODUR 100-5 NH2, 5 µm, 4x3 mm
Special offer
Add to Cart
Recommended application(s)
Guard column, ideal protection for your main column, HPLC
Storage temperature
RT
Scope of delivery
3x analytical HPLC guard columns
Hazardous material
No
Method
HPLC, analytical
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR 100-5 NH2
USP listing
L8
Surface chemistry
Aminopropyl (NH2) modification
Mode
Multi-mode (NP and RP), Normal phase (NP)
Type
EC HPLC guard column (analytical)
Hardware
Stainless steel
Column length
4 mm
Column inner diameter
3 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
5 µm
Eluent in HPLC column
n-heptane
Endcapped
No
Carbon content
2.5 %
pH stability
2.0–8.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
600 bar
MN761953.20
EC HPLC guard column (analytical), NUCLEODUR 100-5 NH2-RP, 5 µm, 4x2 mm
Special offer
Add to Cart
Recommended application(s)
Guard column, ideal protection for your main column, HPLC
Storage temperature
RT
Scope of delivery
3x analytical HPLC guard columns
Hazardous material
No
Method
HPLC, analytical
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR 100-5 NH2-RP
USP listing
L8
Surface chemistry
Aminopropyl (NH2) modification
Mode
Multi-mode (NP and RP), Reversed phase (RP)
Type
EC HPLC guard column (analytical)
Hardware
Stainless steel
Column length
4 mm
Column inner diameter
2 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
5 µm
Eluent in HPLC column
Acetonitrile – water
Endcapped
No
Carbon content
2.5 %
pH stability
2.0–8.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
600 bar
MN761953.30
EC HPLC guard column (analytical), NUCLEODUR 100-5 NH2-RP, 5 µm, 4x3 mm
Special offer
Add to Cart
Recommended application(s)
Guard column, ideal protection for your main column, HPLC
Storage temperature
RT
Scope of delivery
3x analytical HPLC guard columns
Hazardous material
No
Method
HPLC, analytical
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR 100-5 NH2-RP
USP listing
L8
Surface chemistry
Aminopropyl (NH2) modification
Mode
Multi-mode (NP and RP), Reversed phase (RP)
Type
EC HPLC guard column (analytical)
Hardware
Stainless steel
Column length
4 mm
Column inner diameter
3 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
5 µm
Eluent in HPLC column
Acetonitrile – water
Endcapped
No
Carbon content
2.5 %
pH stability
2.0–8.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
600 bar
MN761960.20
EC UHPLC guard column (analytical), NUCLEODUR HILIC, 1.8 µm, 4x2 mm
Special offer
Add to Cart
Recommended application(s)
Guard column, ideal protection for your main column, HPLC
Storage temperature
RT
Scope of delivery
3x analytical HPLC guard columns
Hazardous material
No
Method
HPLC/UHPLC, analytical
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR HILIC
USP listing
Not available or proprietary
Surface chemistry
Ammonium – sulfonic acid (zwitterionic) modification
Mode
Hydrophilic Interaction Chromatography (HILIC)
Type
EC UHPLC guard column (analytical)
Hardware
Stainless steel
Column length
4 mm
Column inner diameter
2 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
1.8 µm
Eluent in HPLC column
Acetonitrile – water
Endcapped
No
Carbon content
7.0 %
pH stability
2.0–8.5
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
900 bar
MN761960.30
EC UHPLC guard column (analytical), NUCLEODUR HILIC, 1.8 µm, 4x3 mm
Special offer
Add to Cart
Recommended application(s)
Guard column, ideal protection for your main column, HPLC
Storage temperature
RT
Scope of delivery
3x analytical HPLC guard columns
Hazardous material
No
Method
HPLC/UHPLC, analytical
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR HILIC
USP listing
Not available or proprietary
Surface chemistry
Ammonium – sulfonic acid (zwitterionic) modification
Mode
Hydrophilic Interaction Chromatography (HILIC)
Type
EC UHPLC guard column (analytical)
Hardware
Stainless steel
Column length
4 mm
Column inner diameter
3 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
1.8 µm
Eluent in HPLC column
Acetonitrile – water
Endcapped
No
Carbon content
7.0 %
pH stability
2.0–8.5
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
900 bar
MN761961.20
EC HPLC guard column (analytical), NUCLEODUR HILIC, 3 µm, 4x2 mm
Special offer
Add to Cart
Recommended application(s)
Guard column, ideal protection for your main column, HPLC
Storage temperature
RT
Scope of delivery
3x analytical HPLC guard columns
Hazardous material
No
Method
HPLC, analytical
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR HILIC
USP listing
Not available or proprietary
Surface chemistry
Ammonium – sulfonic acid (zwitterionic) modification
Mode
Hydrophilic Interaction Chromatography (HILIC)
Type
EC HPLC guard column (analytical)
Hardware
Stainless steel
Column length
4 mm
Column inner diameter
2 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
3 µm
Eluent in HPLC column
Acetonitrile – water
Endcapped
No
Carbon content
7.0 %
pH stability
2.0–8.5
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
600 bar
MN761961.30
EC HPLC guard column (analytical), NUCLEODUR HILIC, 3 µm, 4x3 mm
Special offer
Add to Cart
Recommended application(s)
Guard column, ideal protection for your main column, HPLC
Storage temperature
RT
Scope of delivery
3x analytical HPLC guard columns
Hazardous material
No
Method
HPLC, analytical
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR HILIC
USP listing
Not available or proprietary
Surface chemistry
Ammonium – sulfonic acid (zwitterionic) modification
Mode
Hydrophilic Interaction Chromatography (HILIC)
Type
EC HPLC guard column (analytical)
Hardware
Stainless steel
Column length
4 mm
Column inner diameter
3 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
3 µm
Eluent in HPLC column
Acetonitrile – water
Endcapped
No
Carbon content
7.0 %
pH stability
2.0–8.5
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
600 bar
MN761962.20
EC HPLC guard column (analytical), NUCLEODUR HILIC, 5 µm, 4x2 mm
Special offer
Add to Cart
Recommended application(s)
Guard column, ideal protection for your main column, HPLC
Storage temperature
RT
Scope of delivery
3x analytical HPLC guard columns
Hazardous material
No
Method
HPLC, analytical
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR HILIC
USP listing
Not available or proprietary
Surface chemistry
Ammonium – sulfonic acid (zwitterionic) modification
Mode
Hydrophilic Interaction Chromatography (HILIC)
Type
EC HPLC guard column (analytical)
Hardware
Stainless steel
Column length
4 mm
Column inner diameter
2 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
5 µm
Eluent in HPLC column
Acetonitrile – water
Endcapped
No
Carbon content
7.0 %
pH stability
2.0–8.5
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
600 bar
MN761962.30
EC HPLC guard column (analytical), NUCLEODUR HILIC, 5 µm, 4x3 mm
Special offer
Add to Cart
Recommended application(s)
Guard column, ideal protection for your main column, HPLC
Storage temperature
RT
Scope of delivery
3x analytical HPLC guard columns
Hazardous material
No
Method
HPLC, analytical
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR HILIC
USP listing
Not available or proprietary
Surface chemistry
Ammonium – sulfonic acid (zwitterionic) modification
Mode
Hydrophilic Interaction Chromatography (HILIC)
Type
EC HPLC guard column (analytical)
Hardware
Stainless steel
Column length
4 mm
Column inner diameter
3 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
5 µm
Eluent in HPLC column
Acetonitrile – water
Endcapped
No
Carbon content
7.0 %
pH stability
2.0–8.5
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
600 bar