* NUCLEODUR as a state-of-the-art silica is the ideal base material for modern HPLC phases. It is the result of MACHEREY-NAGEL's pioneering research in chromatography for almost 50 years. NUCLEODUR HPLC columns with 1.8 µm particle size for increased separation efficiency are used for UHPLC applications.

* Due to core-shell technology NUCLEOSHELL columns provide highly efficient separation results with a comparably lower back pressure to fully porous materials.

Catalog No. Product Net Price
MN762390.160 VP HPLC guard column (preparative), NUCLEODUR Sphinx RP, 10x16 mm Special offer 
Add to Cart
  • Recommended application(s)
  • For examples please see analytical NUCLEODUR Sphinx RP, RP applications (preparative)
  • Storage temperature
  • RT
  • Scope of delivery
  • 2x preparative HPLC guard column
  • Hazardous material
  • No
  • Method
  • HPLC, preparative
  • Brand
  • NUCLEODUR
  • Base material
  • NUCLEODUR - high purity silica
  • Phase
  • NUCLEODUR Sphinx RP
  • USP listing
  • L1, L11
  • Surface chemistry
  • Bifunctional RP phase, balanced ratio of propylphenyl and C18 ligands
  • Mode
  • Reversed phase (RP)
  • Type
  • VP HPLC guard column (preparative)
  • Hardware
  • Stainless steel
  • Column length
  • 10 mm
  • Column inner diameter
  • 16 mm
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • Proprietary
  • Eluent in HPLC column
  • Acetonitrile – water
  • Endcapped
  • Yes
  • Carbon content
  • 15.0 %
  • pH stability
  • 1.0–10.0
  • Pore size
  • 110 Å
  • Specific surface according to BET
  • 340 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 400 bar
MN762390.80 VP HPLC guard column (preparative), NUCLEODUR Sphinx RP, 10x8 mm Special offer 
Add to Cart
  • Recommended application(s)
  • For examples please see analytical NUCLEODUR Sphinx RP, RP applications (preparative)
  • Storage temperature
  • RT
  • Scope of delivery
  • 2x preparative HPLC guard column
  • Hazardous material
  • No
  • Method
  • HPLC, preparative
  • Brand
  • NUCLEODUR
  • Base material
  • NUCLEODUR - high purity silica
  • Phase
  • NUCLEODUR Sphinx RP
  • USP listing
  • L1, L11
  • Surface chemistry
  • Bifunctional RP phase, balanced ratio of propylphenyl and C18 ligands
  • Mode
  • Reversed phase (RP)
  • Type
  • VP HPLC guard column (preparative)
  • Hardware
  • Stainless steel
  • Column length
  • 10 mm
  • Column inner diameter
  • 8 mm
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • Proprietary
  • Eluent in HPLC column
  • Acetonitrile – water
  • Endcapped
  • Yes
  • Carbon content
  • 15.0 %
  • pH stability
  • 1.0–10.0
  • Pore size
  • 110 Å
  • Specific surface according to BET
  • 340 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 400 bar
MN762420.160 VP HPLC guard column (preparative), NUCLEODUR C18 Isis, 10x16 mm Special offer 
Add to Cart
  • Recommended application(s)
  • For examples please see analytical NUCLEODUR C18 Isis, RP applications (preparative)
  • Storage temperature
  • RT
  • Scope of delivery
  • 2x preparative HPLC guard column
  • Hazardous material
  • No
  • Method
  • HPLC, preparative
  • Brand
  • NUCLEODUR
  • Base material
  • NUCLEODUR - high purity silica
  • Phase
  • NUCLEODUR C18 Isis
  • USP listing
  • L1
  • Surface chemistry
  • High steric selectivity, Nonpolar crosslinked polymeric octadecyl (C18, ODS) modification
  • Mode
  • Reversed phase (RP)
  • Type
  • VP HPLC guard column (preparative)
  • Hardware
  • Stainless steel
  • Column length
  • 10 mm
  • Column inner diameter
  • 16 mm
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • Proprietary
  • Eluent in HPLC column
  • Acetonitrile – water
  • Endcapped
  • Yes
  • Carbon content
  • 20.0 %
  • pH stability
  • 1.0–10.0
  • Pore size
  • 110 Å
  • Specific surface according to BET
  • 340 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 400 bar
MN762420.80 VP HPLC guard column (preparative), NUCLEODUR C18 Isis, 10x8 mm Special offer 
Add to Cart
  • Recommended application(s)
  • For examples please see analytical NUCLEODUR C18 Isis, RP applications (preparative)
  • Storage temperature
  • RT
  • Scope of delivery
  • 2x preparative HPLC guard column
  • Hazardous material
  • No
  • Method
  • HPLC, preparative
  • Brand
  • NUCLEODUR
  • Base material
  • NUCLEODUR - high purity silica
  • Phase
  • NUCLEODUR C18 Isis
  • USP listing
  • L1
  • Surface chemistry
  • High steric selectivity, Nonpolar crosslinked polymeric octadecyl (C18, ODS) modification
  • Mode
  • Reversed phase (RP)
  • Type
  • VP HPLC guard column (preparative)
  • Hardware
  • Stainless steel
  • Column length
  • 10 mm
  • Column inner diameter
  • 8 mm
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • Proprietary
  • Eluent in HPLC column
  • Acetonitrile – water
  • Endcapped
  • Yes
  • Carbon content
  • 20.0 %
  • pH stability
  • 1.0–10.0
  • Pore size
  • 110 Å
  • Specific surface according to BET
  • 340 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 400 bar
MN762591.160 VP HPLC guard column (preparative), NUCLEODUR C18 HTec, 10x16 mm Special offer 
Add to Cart
  • Recommended application(s)
  • For examples please see analytical NUCLEODUR C18 HTec, RP applications (preparative)
  • Storage temperature
  • RT
  • Scope of delivery
  • 2x preparative HPLC guard column
  • Hazardous material
  • No
  • Method
  • HPLC, preparative
  • Brand
  • NUCLEODUR
  • Base material
  • NUCLEODUR - high purity silica
  • Phase
  • NUCLEODUR C18 HTec
  • USP listing
  • L1
  • Surface chemistry
  • High density octadecyl (C18, ODS) modification, base deactivated (BDS)
  • Mode
  • Reversed phase (RP)
  • Type
  • VP HPLC guard column (preparative)
  • Hardware
  • Stainless steel
  • Column length
  • 10 mm
  • Column inner diameter
  • 16 mm
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • Proprietary
  • Eluent in HPLC column
  • Acetonitrile – water
  • Endcapped
  • Yes
  • Carbon content
  • 18.0 %
  • pH stability
  • 1.0–11.0
  • Pore size
  • 110 Å
  • Specific surface according to BET
  • 340 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 400 bar
MN762591.80 VP HPLC guard column (preparative), NUCLEODUR C18 HTec, 10x8 mm Special offer 
Add to Cart
  • Recommended application(s)
  • For examples please see analytical NUCLEODUR C18 HTec, RP applications (preparative)
  • Storage temperature
  • RT
  • Scope of delivery
  • 2x preparative HPLC guard column
  • Hazardous material
  • No
  • Method
  • HPLC, preparative
  • Brand
  • NUCLEODUR
  • Base material
  • NUCLEODUR - high purity silica
  • Phase
  • NUCLEODUR C18 HTec
  • USP listing
  • L1
  • Surface chemistry
  • High density octadecyl (C18, ODS) modification, base deactivated (BDS)
  • Mode
  • Reversed phase (RP)
  • Type
  • VP HPLC guard column (preparative)
  • Hardware
  • Stainless steel
  • Column length
  • 10 mm
  • Column inner diameter
  • 8 mm
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • Proprietary
  • Eluent in HPLC column
  • Acetonitrile – water
  • Endcapped
  • Yes
  • Carbon content
  • 18.0 %
  • pH stability
  • 1.0–11.0
  • Pore size
  • 110 Å
  • Specific surface according to BET
  • 340 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 400 bar
MN762592.320 VP HPLC guard column (preparative), NUCLEODUR C18 HTec, 15x32 mm Special offer 
Add to Cart
  • Recommended application(s)
  • For examples please see analytical NUCLEODUR C18 HTec, RP applications (preparative)
  • Storage temperature
  • RT
  • Scope of delivery
  • 1x preparative HPLC guard column
  • Hazardous material
  • No
  • Method
  • HPLC, preparative
  • Brand
  • NUCLEODUR
  • Base material
  • NUCLEODUR - high purity silica
  • Phase
  • NUCLEODUR C18 HTec
  • USP listing
  • L1
  • Surface chemistry
  • High density octadecyl (C18, ODS) modification, base deactivated (BDS)
  • Mode
  • Reversed phase (RP)
  • Type
  • VP HPLC guard column (preparative)
  • Hardware
  • Stainless steel
  • Column length
  • 15 mm
  • Column inner diameter
  • 32 mm
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • Proprietary
  • Eluent in HPLC column
  • Acetonitrile – water
  • Endcapped
  • Yes
  • Carbon content
  • 18.0 %
  • pH stability
  • 1.0–11.0
  • Pore size
  • 110 Å
  • Specific surface according to BET
  • 340 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 400 bar
MN762592.500 VP HPLC guard column (preparative), NUCLEODUR C18 HTec, 15x50 mm Special offer 
Add to Cart
  • Recommended application(s)
  • For examples please see analytical NUCLEODUR C18 HTec, RP applications (preparative)
  • Storage temperature
  • RT
  • Scope of delivery
  • 1x preparative HPLC guard column
  • Hazardous material
  • No
  • Method
  • HPLC, preparative
  • Brand
  • NUCLEODUR
  • Base material
  • NUCLEODUR - high purity silica
  • Phase
  • NUCLEODUR C18 HTec
  • USP listing
  • L1
  • Surface chemistry
  • High density octadecyl (C18, ODS) modification, base deactivated (BDS)
  • Mode
  • Reversed phase (RP)
  • Type
  • VP HPLC guard column (preparative)
  • Hardware
  • Stainless steel
  • Column length
  • 15 mm
  • Column inner diameter
  • 50 mm
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • Proprietary
  • Eluent in HPLC column
  • Acetonitrile – water
  • Endcapped
  • Yes
  • Carbon content
  • 18.0 %
  • pH stability
  • 1.0–11.0
  • Pore size
  • 110 Å
  • Specific surface according to BET
  • 340 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 400 bar
MN763138.20 EC HPLC guard column (analytical), NUCLEOSHELL RP 18, 2.7 µm, 4x2 mm Special offer 
Add to Cart
  • Recommended application(s)
  • Guard column, ideal protection for your main column, HPLC
  • Storage temperature
  • RT
  • Scope of delivery
  • 3x analytical HPLC guard columns
  • Hazardous material
  • No
  • Method
  • HPLC, analytical
  • Brand
  • NUCLEOSHELL
  • Base material
  • NUCLEOSHELL - core-shell silica
  • Phase
  • NUCLEOSHELL RP 18
  • USP listing
  • L1
  • Surface chemistry
  • Base deactivated (BDS), High density monomeric octadecyl (C18, ODS) modification
  • Mode
  • Reversed phase (RP)
  • Type
  • EC HPLC guard column (analytical)
  • Hardware
  • Stainless steel
  • Column length
  • 4 mm
  • Column inner diameter
  • 2 mm
  • Particle type
  • Core-shell, superficially porous particles (SPP)
  • Particle shape
  • Spherical
  • Particle size
  • 2.7 µm
  • Eluent in HPLC column
  • Acetonitrile – water
  • Endcapped
  • Yes
  • Carbon content
  • 7.8 %
  • pH stability
  • 1.0–11.0
  • Pore size
  • 90 Å
  • Specific surface according to BET
  • 90 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 600 bar
MN763138.30 EC HPLC guard column (analytical), NUCLEOSHELL RP 18, 2.7 µm, 4x3 mm Special offer 
Add to Cart
  • Recommended application(s)
  • Guard column, ideal protection for your main column, HPLC
  • Storage temperature
  • RT
  • Scope of delivery
  • 3x analytical HPLC guard columns
  • Hazardous material
  • No
  • Method
  • HPLC, analytical
  • Brand
  • NUCLEOSHELL
  • Base material
  • NUCLEOSHELL - core-shell silica
  • Phase
  • NUCLEOSHELL RP 18
  • USP listing
  • L1
  • Surface chemistry
  • Base deactivated (BDS), High density monomeric octadecyl (C18, ODS) modification
  • Mode
  • Reversed phase (RP)
  • Type
  • EC HPLC guard column (analytical)
  • Hardware
  • Stainless steel
  • Column length
  • 4 mm
  • Column inner diameter
  • 3 mm
  • Particle type
  • Core-shell, superficially porous particles (SPP)
  • Particle shape
  • Spherical
  • Particle size
  • 2.7 µm
  • Eluent in HPLC column
  • Acetonitrile – water
  • Endcapped
  • Yes
  • Carbon content
  • 7.8 %
  • pH stability
  • 1.0–11.0
  • Pore size
  • 90 Å
  • Specific surface according to BET
  • 90 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 600 bar

Overview

High performance liquid chromatography (HPLC) is part of liquid chromatographic separating processes of substance mixtures and their analysis. At the beginning the technique was also called high pressure liquid chromatography due to the high back pressure of the column. HPLC offers qualitative (identification of substances) and quantitative (concentration determination) analysis by comparison with standard substances. The term HPLC was introduced in the 1970s, for the delineation of the high-performance method to the in the 1930s developed column liquid chromatography (column chromatography). At the beginning of the 21st century the HPLC was complemented by the even more efficient UHPLC (ultra high performance liquid chromatography). Hereby even higher pressures (> 400 bar) result in shorter analysis time and enhanced efficiency enabling a higher sample throughput with smaller sample volumes.


Detailed information of the particular properties of the high-purity silica phases NUCLEODUR, the established standard silica NUCLEOSIL and the modern Core-Shell material NUCLEOSHELL as well as phases for special separations can be found at the equivalent HPLC- and UHPLC-columns.


Each MACHEREY‑NAGEL HPLC / UHPLC column is individually tested according to the most important characteristic parameters in quality control and the results are documented in a certificate of analysis.



Resources