MN761932.30
EC HPLC guard column (analytical), NUCLEODUR 100-5 C18 ec, 5 µm, 4x3 mm
Special offer
Add to Cart
Recommended application(s)
Guard column, ideal protection for your main column, HPLC
Storage temperature
RT
Scope of delivery
3x analytical HPLC guard columns
Hazardous material
No
Method
HPLC, analytical
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR 100-5 C18 ec
USP listing
L1
Surface chemistry
Medium density monomeric octadecyl (C18, ODS) modification
Mode
Reversed phase (RP)
Type
EC HPLC guard column (analytical)
Hardware
Stainless steel
Column length
4 mm
Column inner diameter
3 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
5 µm
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
17.5 %
pH stability
1.0–9.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
600 bar
MN761936.20
EC HPLC guard column (analytical), NUCLEODUR 100-3 C8 ec, 3 µm, 4x2 mm
Special offer
Add to Cart
Recommended application(s)
Guard column, ideal protection for your main column, HPLC
Storage temperature
RT
Scope of delivery
3x analytical HPLC guard columns
Hazardous material
No
Method
HPLC, analytical
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR 100-3 C8 ec
USP listing
L7
Surface chemistry
Medium density monomeric octyl (C8, MOS) modification
Mode
Reversed phase (RP)
Type
EC HPLC guard column (analytical)
Hardware
Stainless steel
Column length
4 mm
Column inner diameter
2 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
3 µm
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
10.5 %
pH stability
1.0–9.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
600 bar
MN761936.30
EC HPLC guard column (analytical), NUCLEODUR 100-3 C8 ec, 3 µm, 4x3 mm
Special offer
Add to Cart
Recommended application(s)
Guard column, ideal protection for your main column, HPLC
Storage temperature
RT
Scope of delivery
3x analytical HPLC guard columns
Hazardous material
No
Method
HPLC, analytical
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR 100-3 C8 ec
USP listing
L7
Surface chemistry
Medium density monomeric octyl (C8, MOS) modification
Mode
Reversed phase (RP)
Type
EC HPLC guard column (analytical)
Hardware
Stainless steel
Column length
4 mm
Column inner diameter
3 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
3 µm
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
10.5 %
pH stability
1.0–9.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
600 bar
MN761937.20
EC HPLC guard column (analytical), NUCLEODUR 100-5 C8 ec, 5 µm, 4x2 mm
Special offer
Add to Cart
Recommended application(s)
Guard column, ideal protection for your main column, HPLC
Storage temperature
RT
Scope of delivery
3x analytical HPLC guard columns
Hazardous material
No
Method
HPLC, analytical
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR 100-5 C8 ec
USP listing
L7
Surface chemistry
Medium density monomeric octyl (C8, MOS) modification
Mode
Reversed phase (RP)
Type
EC HPLC guard column (analytical)
Hardware
Stainless steel
Column length
4 mm
Column inner diameter
2 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
5 µm
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
10.5 %
pH stability
1.0–9.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
600 bar
MN761937.30
EC HPLC guard column (analytical), NUCLEODUR 100-5 C8 ec, 5 µm, 4x3 mm
Special offer
Add to Cart
Recommended application(s)
Guard column, ideal protection for your main column, HPLC
Storage temperature
RT
Scope of delivery
3x analytical HPLC guard columns
Hazardous material
No
Method
HPLC, analytical
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR 100-5 C8 ec
USP listing
L7
Surface chemistry
Medium density monomeric octyl (C8, MOS) modification
Mode
Reversed phase (RP)
Type
EC HPLC guard column (analytical)
Hardware
Stainless steel
Column length
4 mm
Column inner diameter
3 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
5 µm
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
10.5 %
pH stability
1.0–9.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
600 bar
MN761941.20
EC HPLC guard column (analytical), NUCLEODUR 100-3 CN-RP, 3 µm, 4x2 mm
Special offer
Add to Cart
Recommended application(s)
Guard column, ideal protection for your main column, HPLC
Storage temperature
RT
Scope of delivery
3x analytical HPLC guard columns
Hazardous material
No
Method
HPLC, analytical
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR 100-3 CN-RP
USP listing
L10
Surface chemistry
Cyano, nitrile (CN) modification
Mode
Multi-mode (NP and RP), Reversed phase (RP)
Type
EC HPLC guard column (analytical)
Hardware
Stainless steel
Column length
4 mm
Column inner diameter
2 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
3 µm
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
7.0 %
pH stability
1.0–8.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
600 bar
MN761941.30
EC HPLC guard column (analytical), NUCLEODUR 100-3 CN-RP, 3 µm, 4x3 mm
Special offer
Add to Cart
Recommended application(s)
Guard column, ideal protection for your main column, HPLC
Storage temperature
RT
Scope of delivery
3x analytical HPLC guard columns
Hazardous material
No
Method
HPLC, analytical
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR 100-3 CN-RP
USP listing
L10
Surface chemistry
Cyano, nitrile (CN) modification
Mode
Multi-mode (NP and RP), Reversed phase (RP)
Type
EC HPLC guard column (analytical)
Hardware
Stainless steel
Column length
4 mm
Column inner diameter
3 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
3 µm
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
7.0 %
pH stability
1.0–8.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
600 bar
MN761943.30
EC HPLC guard column (analytical), NUCLEODUR 100-5 CN, 5 µm, 4x3 mm
Special offer
Add to Cart
Recommended application(s)
Guard column, ideal protection for your main column, HPLC
Storage temperature
RT
Scope of delivery
3x analytical HPLC guard columns
Hazardous material
No
Method
HPLC, analytical
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR 100-5 CN
USP listing
L10
Surface chemistry
Cyano, nitrile (CN) modification
Mode
Multi-mode (NP and RP), Normal phase (NP)
Type
EC HPLC guard column (analytical)
Hardware
Stainless steel
Column length
4 mm
Column inner diameter
3 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
5 µm
Eluent in HPLC column
n-heptane
Endcapped
Yes
Carbon content
7.0 %
pH stability
1.0–8.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
600 bar
MN761944.30
EC HPLC guard column (analytical), NUCLEODUR 100-5 CN-RP, 5 µm, 4x3 mm
Special offer
Add to Cart
Recommended application(s)
Guard column, ideal protection for your main column, HPLC
Storage temperature
RT
Scope of delivery
3x analytical HPLC guard columns
Hazardous material
No
Method
HPLC, analytical
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR 100-5 CN-RP
USP listing
L10
Surface chemistry
Cyano, nitrile (CN) modification
Mode
Multi-mode (NP and RP), Reversed phase (RP)
Type
EC HPLC guard column (analytical)
Hardware
Stainless steel
Column length
4 mm
Column inner diameter
3 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
5 µm
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
7.0 %
pH stability
1.0–8.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
600 bar
MN761951.20
EC HPLC guard column (analytical), NUCLEODUR 100-3 NH2-RP, 3 µm, 4x2 mm
Special offer
Add to Cart
Recommended application(s)
Guard column, ideal protection for your main column, HPLC
Storage temperature
RT
Scope of delivery
3x analytical HPLC guard columns
Hazardous material
No
Method
HPLC, analytical
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR 100-3 NH2-RP
USP listing
L8
Surface chemistry
Aminopropyl (NH2) modification
Mode
Multi-mode (NP and RP), Reversed phase (RP)
Type
EC HPLC guard column (analytical)
Hardware
Stainless steel
Column length
4 mm
Column inner diameter
2 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
3 µm
Eluent in HPLC column
Acetonitrile – water
Endcapped
No
Carbon content
2.5 %
pH stability
2.0–8.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
600 bar