METL59909548 |
pH Sensor InPro4501/1000/SG/10m/S/T
|
Special offer
|
Add to Cart
|
- Cable Connector
- Fixed cable 10 m
- Certificates & Approvals
- CE METTLER TOLEDO Quality Certificate FM: IS Cl. I, II, III, Div 1, GR ABCDEFG/T6 ATEX/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb PED
- Connection
- 1 inch NPT
- Hazardous Area Approvals
- Yes
- Hygienic/Biocompatibility Approvals
- No
- ISM (Digital) or Analog
- Analog
- Measurement Parameter
- pH
- Model Family
- InPro4500
- Operating Pressure (Bar)
- 0 to 6 barg @ 65 °C
- Operating Pressure (PSI)
- 0 to 87 psig @ 149 °F
- Operating Temperature (Celsius)
- 0 °C - 100 °C
- Operating Temperature (Fahrenheit)
- 32 °F - 212 °F
- pH Range
- 1 – 14
- pH Sensing Technology
- Glass Membrane Suitable For Low Temperatures (LoT)
- Primary Media/Application
- Chemical Processes
- Process Connection
- 1 inch NPT
- Reference System
- Xerolyt Extra polymer electrolyte, open double junction, Argenthal cartridge with silver-ion trap
- Refillable Electrolyte
- No
- Sensor Length
- 72.5 mm
- Shaft Material
- PVDF
- Sterilizable/Autoclavable
- No
- Temperature Sensor
- PT 1000
|
|
METL59909570 |
pH Sensor InPro4501/VP/PT100/SG
|
Special offer
|
Add to Cart
|
- Cable Connector
- VP
- Certificates & Approvals
- CE METTLER TOLEDO Quality Certificate FM: IS Cl. I, II, III, Div 1, GR ABCDEFG/T6 ATEX/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb PED
- Connection
- 1 inch NPT
- Hazardous Area Approvals
- Yes
- Hygienic/Biocompatibility Approvals
- No
- ISM (Digital) or Analog
- Analog
- Measurement Parameter
- pH
- Model Family
- InPro4500
- Operating Pressure (Bar)
- 0 to 6 barg @ 65 °C
- Operating Pressure (PSI)
- 0 to 87 psig @ 149 °F
- Operating Temperature (Celsius)
- 0 °C - 100 °C
- Operating Temperature (Fahrenheit)
- 32 °F - 212 °F
- pH Range
- 1 – 14
- pH Sensing Technology
- Glass Membrane Suitable For Low Temperatures (LoT)
- Primary Media/Application
- Chemical Processes
- Process Connection
- 1 inch NPT
- Reference System
- Xerolyt Extra polymer electrolyte, open double junction, Argenthal cartridge with silver-ion trap
- Refillable Electrolyte
- No
- Sensor Length
- 72.5 mm
- Shaft Material
- PVDF
- Sterilizable/Autoclavable
- No
- Temperature Sensor
- Pt 100
|
|
METL59909571 |
pH Sensor InPro4501/VP/PT1000/SG
|
Special offer
|
Add to Cart
|
- Cable Connector
- VP
- Certificates & Approvals
- CE METTLER TOLEDO Quality Certificate FM: IS Cl. I, II, III, Div 1, GR ABCDEFG/T6 ATEX/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb PED
- Connection
- 1 inch NPT
- Hazardous Area Approvals
- Yes
- Hygienic/Biocompatibility Approvals
- No
- ISM (Digital) or Analog
- Analog
- Measurement Parameter
- pH
- Model Family
- InPro4500
- Operating Pressure (Bar)
- 0 to 6 barg @ 65 °C
- Operating Pressure (PSI)
- 0 to 87 psig @ 149 °F
- Operating Temperature (Celsius)
- 0 °C - 100 °C
- Operating Temperature (Fahrenheit)
- 32 °F - 212 °F
- pH Range
- 1 – 14
- pH Sensing Technology
- Glass Membrane Suitable For Low Temperatures (LoT)
- Primary Media/Application
- Chemical Processes
- Process Connection
- 1 inch NPT
- Reference System
- Xerolyt Extra polymer electrolyte, open double junction, Argenthal cartridge with silver-ion trap
- Refillable Electrolyte
- No
- Sensor Length
- 72.5 mm
- Shaft Material
- PVDF
- Sterilizable/Autoclavable
- No
- Temperature Sensor
- PT 1000
|
|
METL52002401 |
pH Sensor InPro4550/VP/PT100/SG
|
Special offer
|
Add to Cart
|
- Cable Connector
- VP
- Certificates & Approvals
- CE METTLER TOLEDO Quality Certificate FM: IS Cl. I, II, III, Div 1, GR ABCDEFG/T6 ATEX/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb PED
- Connection
- 1 inch NPT
- Hazardous Area Approvals
- Yes
- Hygienic/Biocompatibility Approvals
- No
- ISM (Digital) or Analog
- Analog
- Measurement Parameter
- pH
- Model Family
- InPro4500
- Operating Pressure (Bar)
- 0 to 7 barg @ 130°C
- Operating Pressure (PSI)
- 0 to 101 psig @ 266°F
- Operating Temperature (Celsius)
- 0 °C - 130 °C
- Operating Temperature (Fahrenheit)
- 32 °F - 266 °F
- pH Range
- 0 – 14
- pH Sensing Technology
- Highly Alkali Resistant Glass Membrane for Tough Conditions (HA)
- Primary Media/Application
- Chemical Processes
- Process Connection
- 1 inch NPT
- Reference System
- Xerolyt Extra polymer electrolyte, open double junction, Argenthal cartridge with silver-ion trap
- Refillable Electrolyte
- No
- Sensor Length
- 72.5 mm
- Shaft Material
- PPS
- Sterilizable/Autoclavable
- No
- Temperature Sensor
- Pt 100
|
|
METL52002402 |
pH Sensor InPro4550/VP/PT1000/SG
|
Special offer
|
Add to Cart
|
- Cable Connector
- VP
- Certificates & Approvals
- CE METTLER TOLEDO Quality Certificate FM: IS Cl. I, II, III, Div 1, GR ABCDEFG/T6 ATEX/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb PED
- Connection
- 1 inch NPT
- Hazardous Area Approvals
- Yes
- Hygienic/Biocompatibility Approvals
- No
- ISM (Digital) or Analog
- Analog
- Measurement Parameter
- pH
- Model Family
- InPro4500
- Operating Pressure (Bar)
- 0 to 7 barg @ 130°C
- Operating Pressure (PSI)
- 0 to 101 psig @ 266°F
- Operating Temperature (Celsius)
- 0 °C - 130 °C
- Operating Temperature (Fahrenheit)
- 32 °F - 266 °F
- pH Range
- 0 – 14
- pH Sensing Technology
- Highly Alkali Resistant Glass Membrane for Tough Conditions (HA)
- Primary Media/Application
- Chemical Processes
- Process Connection
- 1 inch NPT
- Reference System
- Xerolyt Extra polymer electrolyte, open double junction, Argenthal cartridge with silver-ion trap
- Refillable Electrolyte
- No
- Sensor Length
- 72.5 mm
- Shaft Material
- PPS
- Sterilizable/Autoclavable
- No
- Temperature Sensor
- PT 1000
|
|
METL52002124 |
pH Sensor InPro4800/120/PT100
|
Special offer
|
Add to Cart
|
- Cable Connector
- VP
- Certificates & Approvals
- CE METTLER TOLEDO Quality Certificate FM: IS Cl. I, II, III, Div 1, GR ABCDEFG/T6 ATEX/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb PED
- Connection
- Pg 13.5 Thread
- Hazardous Area Approvals
- Yes
- Hygienic/Biocompatibility Approvals
- No
- ISM (Digital) or Analog
- Analog
- Measurement Parameter
- pH
- Model Family
- InPro4800(i)
- Operating Pressure (Bar)
- 0 to 12 barg @ 130 °C
- Operating Pressure (PSI)
- 0 to 174 psig @ 266 °F
- Operating Temperature (Celsius)
- -5 °C - 130 °C
- Operating Temperature (Fahrenheit)
- 23 °F - 266 °F
- pH Range
- 0 – 14
- pH Sensing Technology
- Highly Alkali Resistant Glass Membrane for Tough Conditions (HA)
- Primary Media/Application
- Chemical Processes
- Process Connection
- Pg 13.5 Thread
- Reference System
- Gel electrolyte, PTFE annular diaphragm, pressure compensated double chamber Ag/AgCl system
- Refillable Electrolyte
- No
- Sensor Length
- 120 mm
- Shaft Material
- Glass
- Sterilizable/Autoclavable
- No
- Temperature Sensor
- Pt 100
|
|
METL52002125 |
pH Sensor InPro4800/120/PT1000
|
Special offer
|
Add to Cart
|
- Cable Connector
- VP
- Certificates & Approvals
- CE METTLER TOLEDO Quality Certificate FM: IS Cl. I, II, III, Div 1, GR ABCDEFG/T6 ATEX/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb PED
- Connection
- Pg 13.5 Thread
- Hazardous Area Approvals
- Yes
- Hygienic/Biocompatibility Approvals
- No
- ISM (Digital) or Analog
- Analog
- Measurement Parameter
- pH
- Model Family
- InPro4800(i)
- Operating Pressure (Bar)
- 0 to 12 barg @ 130 °C
- Operating Pressure (PSI)
- 0 to 174 psig @ 266 °F
- Operating Temperature (Celsius)
- -5 °C - 130 °C
- Operating Temperature (Fahrenheit)
- 23 °F - 266 °F
- pH Range
- 0 – 14
- pH Sensing Technology
- Highly Alkali Resistant Glass Membrane for Tough Conditions (HA)
- Primary Media/Application
- Chemical Processes
- Process Connection
- Pg 13.5 Thread
- Reference System
- Gel electrolyte, PTFE annular diaphragm, pressure compensated double chamber Ag/AgCl system
- Refillable Electrolyte
- No
- Sensor Length
- 120 mm
- Shaft Material
- Glass
- Sterilizable/Autoclavable
- No
- Temperature Sensor
- PT 1000
|
|
METL52002126 |
pH Sensor InPro4800/225/PT100
|
Special offer
|
Add to Cart
|
- Cable Connector
- VP
- Certificates & Approvals
- CE METTLER TOLEDO Quality Certificate FM: IS Cl. I, II, III, Div 1, GR ABCDEFG/T6 ATEX/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb PED
- Connection
- Pg 13.5 Thread
- Hazardous Area Approvals
- Yes
- Hygienic/Biocompatibility Approvals
- No
- ISM (Digital) or Analog
- Analog
- Measurement Parameter
- pH
- Model Family
- InPro4800(i)
- Operating Pressure (Bar)
- 0 to 12 barg @ 130 °C
- Operating Pressure (PSI)
- 0 to 174 psig @ 266 °F
- Operating Temperature (Celsius)
- -5 °C - 130 °C
- Operating Temperature (Fahrenheit)
- 23 °F - 266 °F
- pH Range
- 0 – 14
- pH Sensing Technology
- Highly Alkali Resistant Glass Membrane for Tough Conditions (HA)
- Primary Media/Application
- Chemical Processes
- Process Connection
- Pg 13.5 Thread
- Reference System
- Gel electrolyte, PTFE annular diaphragm, pressure compensated double chamber Ag/AgCl system
- Refillable Electrolyte
- No
- Sensor Length
- 225 mm
- Shaft Material
- Glass
- Sterilizable/Autoclavable
- No
- Temperature Sensor
- Pt 100
|
|
METL52002127 |
pH Sensor InPro4800/225/PT1000
|
Special offer
|
Add to Cart
|
- Cable Connector
- VP
- Certificates & Approvals
- CE METTLER TOLEDO Quality Certificate FM: IS Cl. I, II, III, Div 1, GR ABCDEFG/T6 ATEX/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb PED
- Connection
- Pg 13.5 Thread
- Hazardous Area Approvals
- Yes
- Hygienic/Biocompatibility Approvals
- No
- ISM (Digital) or Analog
- Analog
- Measurement Parameter
- pH
- Model Family
- InPro4800(i)
- Operating Pressure (Bar)
- 0 to 12 barg @ 130 °C
- Operating Pressure (PSI)
- 0 to 174 psig @ 266 °F
- Operating Temperature (Celsius)
- -5 °C - 130 °C
- Operating Temperature (Fahrenheit)
- 23 °F - 266 °F
- pH Range
- 0 – 14
- pH Sensing Technology
- Highly Alkali Resistant Glass Membrane for Tough Conditions (HA)
- Primary Media/Application
- Chemical Processes
- Process Connection
- Pg 13.5 Thread
- Reference System
- Gel electrolyte, PTFE annular diaphragm, pressure compensated double chamber Ag/AgCl system
- Refillable Electrolyte
- No
- Sensor Length
- 225 mm
- Shaft Material
- Glass
- Sterilizable/Autoclavable
- No
- Temperature Sensor
- PT 1000
|
|
METL52002129 |
pH Sensor InPro4800/425/PT100
|
Special offer
|
Add to Cart
|
- Cable Connector
- VP
- Certificates & Approvals
- CE METTLER TOLEDO Quality Certificate FM: IS Cl. I, II, III, Div 1, GR ABCDEFG/T6 ATEX/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb PED
- Connection
- Pg 13.5 Thread
- Hazardous Area Approvals
- Yes
- Hygienic/Biocompatibility Approvals
- No
- ISM (Digital) or Analog
- Analog
- Measurement Parameter
- pH
- Model Family
- InPro4800(i)
- Operating Pressure (Bar)
- 0 to 12 barg @ 130 °C
- Operating Pressure (PSI)
- 0 to 174 psig @ 266 °F
- Operating Temperature (Celsius)
- -5 °C - 130 °C
- Operating Temperature (Fahrenheit)
- 23 °F - 266 °F
- pH Range
- 0 – 14
- pH Sensing Technology
- Highly Alkali Resistant Glass Membrane for Tough Conditions (HA)
- Primary Media/Application
- Chemical Processes
- Process Connection
- Pg 13.5 Thread
- Reference System
- Gel electrolyte, PTFE annular diaphragm, pressure compensated double chamber Ag/AgCl system
- Refillable Electrolyte
- No
- Sensor Length
- 425 mm
- Shaft Material
- Glass
- Sterilizable/Autoclavable
- No
- Temperature Sensor
- Pt 100
|