METL30301406
pH Sensor InPro4881i/SG/225
Special offer
Add to Cart
Cable Connector
K8S
Certificates & Approvals
CE METTLER TOLEDO Quality Certificate FM: IS Cl. I, II, III, Div 1, GR ABCDEFG/T6 ATEX/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb PED
Connection
Pg 13.5 Thread
Hazardous Area Approvals
Yes
Hygienic/Biocompatibility Approvals
No
ISM (Digital) or Analog
ISM (Digital)
Measurement Parameter
pH
Model Family
InPro4800(i)
Operating Pressure (Bar)
0 to 12 barg @ 80°C
Operating Pressure (PSI)
0 to 174 psig @ 176°F
Operating Temperature (Celsius)
-5 °C - 80 °C
Operating Temperature (Fahrenheit)
23 °F - 176 °F
pH Range
1 – 14
pH Sensing Technology
Glass Membrane Suitable For Low Temperatures (LoT)
Primary Media/Application
Chemical Processes
Process Connection
Pg 13.5 Thread
Reference System
Gel electrolyte, PTFE annular diaphragm, pressure compensated double chamber Ag/AgCl system
Refillable Electrolyte
No
Sensor Length
225 mm
Shaft Material
Titanium
Sterilizable/Autoclavable
No
Temperature Sensor
Digital
METL30301407
pH Sensor InPro4881i/SG/425
Special offer
Add to Cart
Cable Connector
K8S
Certificates & Approvals
CE METTLER TOLEDO Quality Certificate FM: IS Cl. I, II, III, Div 1, GR ABCDEFG/T6 ATEX/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb PED
Connection
Pg 13.5 Thread
Hazardous Area Approvals
Yes
Hygienic/Biocompatibility Approvals
No
ISM (Digital) or Analog
ISM (Digital)
Measurement Parameter
pH
Model Family
InPro4800(i)
Operating Pressure (Bar)
0 to 12 barg @ 80°C
Operating Pressure (PSI)
0 to 174 psig @ 176°F
Operating Temperature (Celsius)
-5 °C - 80 °C
Operating Temperature (Fahrenheit)
23 °F - 176 °F
pH Range
1 – 14
pH Sensing Technology
Glass Membrane Suitable For Low Temperatures (LoT)
Primary Media/Application
Chemical Processes
Process Connection
Pg 13.5 Thread
Reference System
Gel electrolyte, PTFE annular diaphragm, pressure compensated double chamber Ag/AgCl system
Refillable Electrolyte
No
Sensor Length
425 mm
Shaft Material
Titanium
Sterilizable/Autoclavable
No
Temperature Sensor
Digital
METL30019005
CO2 Sensor InPro5000i/12/220
Special offer
Add to Cart
Cable Connector
K8S
Certificates & Approvals
Quality certificate, Material certificate 3.1, Surface finish certificate, FDA/USP Class IV
Connection
Pg 13.5
Hygienic/Biocompatibility Approvals
EHEDG EL Class 1, USP ClassVI/FDA/USP Class 7
Intelligent Sensor Management (ISM®)
Yes
ISM (Digital) or Analog
ISM (Digital)
Measured Pressure Resistance
0.2 bar – 2 bar
Measurement Parameter
Carbon Dioxide
Measuring Temp. Range
32 °F – 140 °F (0 °C – 60 °C)
Model Family
InPro 5000i
Operating Pressure (Bar)
0.200 bar–2.000 bar
Operating Pressure (PSI)
2.9 psi – 30 psi
Primary Media/Application
Pharmaceutical/Life Science Production
Process Connection
Pg 13.5
Sensor Length
220 mm
Temp. Range
32 °F – 140 °F (0 °C – 60 °C)
METL30019006
CO2 Sensor InPro5000i/12/320
Special offer
Add to Cart
Cable Connector
K8S
Certificates & Approvals
Quality certificate, Material certificate 3.1, Surface finish certificate, FDA/USP Class IV
Connection
Pg 13.5
Hygienic/Biocompatibility Approvals
EHEDG EL Class 1, USP ClassVI/FDA/USP Class 7
Intelligent Sensor Management (ISM®)
Yes
ISM (Digital) or Analog
ISM (Digital)
Measured Pressure Resistance
0.2 bar – 2 bar
Measurement Parameter
Carbon Dioxide
Measuring Temp. Range
32 °F – 140 °F (0 °C – 60 °C)
Model Family
InPro 5000i
Operating Pressure (Bar)
0.200 bar–2.000 bar
Operating Pressure (PSI)
2.9 psi – 30 psi
Primary Media/Application
Pharmaceutical/Life Science Production
Process Connection
Pg 13.5
Sensor Length
320 mm
Temp. Range
32 °F – 140 °F (0 °C – 60 °C)
METL30013606
CO2 Sensor InPro5000i/12/120
Special offer
Add to Cart
Cable Connector
K8S
Certificates & Approvals
Quality certificate, Material certificate 3.1, Surface finish certificate, FDA/USP Class IV
Connection
Pg 13.5
Hygienic/Biocompatibility Approvals
EHEDG EL Class 1, USP ClassVI/FDA/USP Class 7
ISM (Digital) or Analog
ISM (Digital)
Measured Pressure Resistance
0.2 bar – 2 bar
Measurement Parameter
Carbon Dioxide
Measuring Temp. Range
32 °F – 140 °F (0 °C – 60 °C)
Model Family
InPro 5000i
Operating Pressure (Bar)
0.200 bar–2.000 bar
Operating Pressure (PSI)
2.9 psi – 30 psi
Primary Media/Application
Pharmaceutical/Life Science Production
Process Connection
Pg 13.5
Sensor Length
120 mm
Temp. Range
32 °F – 140 °F (0 °C – 60 °C)
METL30034264
CO2 Sensor InPro5500i/D28/M42
Special offer
Add to Cart
Cable Connector
M12 5 PIN
Certificates & Approvals
Quality certificate, Material certificate 3.1, Surface finish certificate
Connection
29 mm with cap nut M42
Hygienic/Biocompatibility Approvals
FDA
ISM (Digital) or Analog
ISM (Digital)
Measurement Parameter
Carbon Dioxide
Measuring Temp. Range
32 °F – 122 °F (0 °C – 50 °C)
Model Family
InPro 5500i
Operating Pressure (Bar)
0-20 bar
Operating Pressure (PSI)
362.6 psi
Primary Media/Application
Food and Beverage
Process Connection
29 mm with cap nut M42
Temp. Range
32 °F – 122 °F (0 °C – 50 °C)
METL30034266
CO2 Sensor InPro5500i/TriClamp 2''
Special offer
Add to Cart
Cable Connector
M12 5 PIN
Certificates & Approvals
Quality certificate, Material certificate 3.1, Surface finish certificate
Connection
Tri-Clamp 2"
Hygienic/Biocompatibility Approvals
FDA
ISM (Digital) or Analog
ISM (Digital)
Measurement Parameter
Carbon Dioxide
Measuring Temp. Range
32 °F – 122 °F (0 °C – 50 °C)
Model Family
InPro 5500i
Operating Pressure (Bar)
0-20 bar
Operating Pressure (PSI)
362.6 psi
Primary Media/Application
Food and Beverage
Process Connection
Tri-Clamp 2"
Temp. Range
32 °F – 122 °F (0 °C – 50 °C)
METL30034265
CO2 Sensor InPro5500i/Var. Type N
Special offer
Add to Cart
Cable Connector
M12 5 PIN
Certificates & Approvals
Quality certificate, Material certificate 3.1, Surface finish certificate
Connection
Varivent Type N
Hygienic/Biocompatibility Approvals
FDA
ISM (Digital) or Analog
ISM (Digital)
Measurement Parameter
Carbon Dioxide
Measuring Temp. Range
32 °F – 122 °F (0 °C – 50 °C)
Model Family
InPro 5500i
Operating Pressure (Bar)
0-20 bar
Operating Pressure (PSI)
362.6 psi
Primary Media/Application
Food and Beverage
Process Connection
Varivent Type N
Temp. Range
32 °F – 122 °F (0 °C – 50 °C)
METL52200851
DO Sensor InPro6050/120
Special offer
Add to Cart
Cable Connector
VP6 analog
Certificates & Approvals
Quality Certificate
Connection
Pg 13.5
ISM (Digital) or Analog
Analog
Measurement Parameter
Oxygen
Measurement range
30 ppb - sat.
Measuring Temp. Range
32 °F – 140 °F (0 °C – 60 °C)
Model Family
InPro6050
Primary Media/Application
Wastewater Chemical Processes
Process Connection
Pg 13.5
Sensor Length
120 mm
Temp. Range
23 °F – 140 °F (-5 °C – 60 °C)
METL52200964
DO Sensor InPro6800/12/070
Special offer
Add to Cart
Cable Connector
VP7
Certificates & Approvals
Quality certificate, Material certificate 3.1, Surface finish certificate, ATEX/IECEx/FM certificate, FDA/USP Class IV
Connection
Pg 13.5
Hazardous Area Approvals
FM (C US): IS / I, II, III / 1 / ABCDEFG/ T6 Ta=60 °C 53 800 002 Entity ATEX:/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb/Ex ia IIIC T69°C/T81°C/T109°C/T161°C Da/Db
Hygienic/Biocompatibility Approvals
EHEDG/FDA/USP Class 7
ISM (Digital) or Analog
Analog
Measured Pressure Resistance
0.2 bar – 6 bar
Measurement Parameter
Oxygen
Measurement range
0-100% O2 saturation
Measuring Temp. Range
32 °F – 176 °F (0 °C – 80 °C)
Model Family
InPro 6800/6850i
Operating Pressure (Bar)
0.2–6 Bar
Operating Pressure (PSI)
0–87 PSI
Primary Media/Application
Pharmaceutical/Life Science Production
Process Connection
Pg 13.5
Sensor Length
70 mm
Sterilizable/Autoclavable
Yes
Temp. Range
23 °F – 284 °F (-5 °C – 140 °C)