+852-3069 6950
css@gugent.com.hk
 

Process Analytics


Process Instrumentation for measuring pH, Dissolved Oxygen, Conductivity, Turbidity, TOC, Sodium, Silica, Gas Analyzer


Catalog No. Product Net Price
METL52000511 pH Sensor InPro4010/120/PT100 Special offer 
Add to Cart
  • Cable Connector
  • VP
  • Certificates & Approvals
  • CE METTLER TOLEDO Quality Certificate PED
  • Connection
  • Pg 13.5 Thread
  • Hazardous Area Approvals
  • No
  • Hygienic/Biocompatibility Approvals
  • No
  • ISM (Digital) or Analog
  • Analog
  • Measurement Parameter
  • pH
  • Model Family
  • InPro 4010
  • Operating Pressure (Bar)
  • 0 to 1 barg @ 60°C
  • Operating Pressure (PSI)
  • 0 to 15 psig @ 140°F
  • Operating Temperature (Celsius)
  • 0 °C - 60 °C
  • Operating Temperature (Fahrenheit)
  • 32 °F - 140 °F
  • pH Range
  • 2 – 12
  • pH Sensing Technology
  • General Purpose Glass Membrane
  • Primary Media/Application
  • Wastewater
  • Process Connection
  • Pg 13.5 Thread
  • Reference System
  • Xerolyt® polymer electrolyte, open double junction, Argenthal cartridge with silver-ion trap
  • Refillable Electrolyte
  • No
  • Sensor Length
  • 120 mm
  • Shaft Material
  • PEEK
  • Sterilizable/Autoclavable
  • No
  • Temperature Sensor
  • Pt 100
METL52000512 pH Sensor InPro4010/120/PT1000 Special offer 
Add to Cart
  • Cable Connector
  • VP
  • Certificates & Approvals
  • CE METTLER TOLEDO Quality Certificate PED
  • Connection
  • Pg 13.5 Thread
  • Hazardous Area Approvals
  • No
  • Hygienic/Biocompatibility Approvals
  • No
  • ISM (Digital) or Analog
  • Analog
  • Measurement Parameter
  • pH
  • Model Family
  • InPro 4010
  • Operating Pressure (Bar)
  • 0 to 1 barg @ 60°C
  • Operating Pressure (PSI)
  • 0 to 15 psig @ 140°F
  • Operating Temperature (Celsius)
  • 0 °C - 60 °C
  • Operating Temperature (Fahrenheit)
  • 32 °F - 140 °F
  • pH Range
  • 2 – 12
  • pH Sensing Technology
  • General Purpose Glass Membrane
  • Primary Media/Application
  • Wastewater
  • Process Connection
  • Pg 13.5 Thread
  • Reference System
  • Xerolyt® polymer electrolyte, open double junction, Argenthal cartridge with silver-ion trap
  • Refillable Electrolyte
  • No
  • Sensor Length
  • 120 mm
  • Shaft Material
  • PEEK
  • Sterilizable/Autoclavable
  • No
  • Temperature Sensor
  • PT 1000
METL52002986 pH Sensor InPro4260/120/PT100 Special offer 
Add to Cart
  • Cable Connector
  • VP
  • Certificates & Approvals
  • CE METTLER TOLEDO Quality Certificate FM: IS Cl. I, II, III, Div 1, GR ABCDEFG/T6 ATEX/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb PED
  • Connection
  • Pg 13.5 Thread
  • Hazardous Area Approvals
  • Yes
  • Hygienic/Biocompatibility Approvals
  • No
  • ISM (Digital) or Analog
  • Analog
  • Measurement Parameter
  • pH
  • Model Family
  • InPro4260(i)
  • Operating Pressure (Bar)
  • 0 to 15 barg @ 25°C 0 to 7 barg @ 130°C
  • Operating Pressure (PSI)
  • 0 to 101 psig @ 266°F 0 to 217 psig @ 77°F
  • Operating Temperature (Celsius)
  • 0 °C - 130 °C
  • Operating Temperature (Fahrenheit)
  • 32 °F - 266 °F
  • pH Range
  • 0 – 14
  • pH Sensing Technology
  • Highly Alkali Resistant Glass Membrane for Tough Conditions (HA)
  • Primary Media/Application
  • Chemical Processes
  • Process Connection
  • Pg 13.5 Thread
  • Reference System
  • Xerolyt Extra polymer electrolyte, open double junction, Argenthal cartridge with silver-ion trap
  • Refillable Electrolyte
  • No
  • Sensor Length
  • 120 mm
  • Shaft Material
  • Glass
  • Sterilizable/Autoclavable
  • No
  • Temperature Sensor
  • Pt 100
METL52002987 pH Sensor InPro4260/120/PT1000 Special offer 
Add to Cart
  • Cable Connector
  • VP
  • Certificates & Approvals
  • CE METTLER TOLEDO Quality Certificate FM: IS Cl. I, II, III, Div 1, GR ABCDEFG/T6 ATEX/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb PED
  • Connection
  • Pg 13.5 Thread
  • Hazardous Area Approvals
  • Yes
  • Hygienic/Biocompatibility Approvals
  • No
  • ISM (Digital) or Analog
  • Analog
  • Measurement Parameter
  • pH
  • Model Family
  • InPro4260(i)
  • Operating Pressure (Bar)
  • 0 to 15 barg @ 25°C 0 to 7 barg @ 130°C
  • Operating Pressure (PSI)
  • 0 to 101 psig @ 266°F 0 to 217 psig @ 77°F
  • Operating Temperature (Celsius)
  • 0 °C - 130 °C
  • Operating Temperature (Fahrenheit)
  • 32 °F - 266 °F
  • pH Range
  • 0 – 14
  • pH Sensing Technology
  • Highly Alkali Resistant Glass Membrane for Tough Conditions (HA)
  • Primary Media/Application
  • Chemical Processes
  • Process Connection
  • Pg 13.5 Thread
  • Reference System
  • Xerolyt Extra polymer electrolyte, open double junction, Argenthal cartridge with silver-ion trap
  • Refillable Electrolyte
  • No
  • Sensor Length
  • 120 mm
  • Shaft Material
  • Glass
  • Sterilizable/Autoclavable
  • No
  • Temperature Sensor
  • PT 1000
METL52002988 pH Sensor InPro4260/225/PT100 Special offer 
Add to Cart
  • Cable Connector
  • VP
  • Certificates & Approvals
  • CE METTLER TOLEDO Quality Certificate FM: IS Cl. I, II, III, Div 1, GR ABCDEFG/T6 ATEX/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb PED
  • Connection
  • Pg 13.5 Thread
  • Hazardous Area Approvals
  • Yes
  • Hygienic/Biocompatibility Approvals
  • No
  • ISM (Digital) or Analog
  • Analog
  • Measurement Parameter
  • pH
  • Model Family
  • InPro4260(i)
  • Operating Pressure (Bar)
  • 0 to 15 barg @ 25°C 0 to 7 barg @ 130°C
  • Operating Pressure (PSI)
  • 0 to 101 psig @ 266°F 0 to 217 psig @ 77°F
  • Operating Temperature (Celsius)
  • 0 °C - 130 °C
  • Operating Temperature (Fahrenheit)
  • 32 °F - 266 °F
  • pH Range
  • 0 – 14
  • pH Sensing Technology
  • Highly Alkali Resistant Glass Membrane for Tough Conditions (HA)
  • Primary Media/Application
  • Chemical Processes
  • Process Connection
  • Pg 13.5 Thread
  • Reference System
  • Xerolyt Extra polymer electrolyte, open double junction, Argenthal cartridge with silver-ion trap
  • Refillable Electrolyte
  • No
  • Sensor Length
  • 225 mm
  • Shaft Material
  • Glass
  • Sterilizable/Autoclavable
  • No
  • Temperature Sensor
  • Pt 100
METL52002989 pH Sensor InPro4260/225/PT1000 Special offer 
Add to Cart
  • Cable Connector
  • VP
  • Certificates & Approvals
  • CE METTLER TOLEDO Quality Certificate FM: IS Cl. I, II, III, Div 1, GR ABCDEFG/T6 ATEX/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb PED
  • Connection
  • Pg 13.5 Thread
  • Hazardous Area Approvals
  • Yes
  • Hygienic/Biocompatibility Approvals
  • No
  • ISM (Digital) or Analog
  • Analog
  • Measurement Parameter
  • pH
  • Model Family
  • InPro4260(i)
  • Operating Pressure (Bar)
  • 0 to 15 barg @ 25°C 0 to 7 barg @ 130°C
  • Operating Pressure (PSI)
  • 0 to 101 psig @ 266°F 0 to 217 psig @ 77°F
  • Operating Temperature (Celsius)
  • 0 °C - 130 °C
  • Operating Temperature (Fahrenheit)
  • 32 °F - 266 °F
  • pH Range
  • 0 – 14
  • pH Sensing Technology
  • Highly Alkali Resistant Glass Membrane for Tough Conditions (HA)
  • Primary Media/Application
  • Chemical Processes
  • Process Connection
  • Pg 13.5 Thread
  • Reference System
  • Xerolyt Extra polymer electrolyte, open double junction, Argenthal cartridge with silver-ion trap
  • Refillable Electrolyte
  • No
  • Sensor Length
  • 225 mm
  • Shaft Material
  • Glass
  • Sterilizable/Autoclavable
  • No
  • Temperature Sensor
  • PT 1000
METL52002992 pH Sensor InPro4260/425/PT100 Special offer 
Add to Cart
  • Cable Connector
  • VP
  • Certificates & Approvals
  • CE METTLER TOLEDO Quality Certificate FM: IS Cl. I, II, III, Div 1, GR ABCDEFG/T6 ATEX/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb PED
  • Connection
  • Pg 13.5 Thread
  • Hazardous Area Approvals
  • Yes
  • Hygienic/Biocompatibility Approvals
  • No
  • ISM (Digital) or Analog
  • Analog
  • Measurement Parameter
  • pH
  • Model Family
  • InPro4260(i)
  • Operating Pressure (Bar)
  • 0 to 15 barg @ 25°C 0 to 7 barg @ 130°C
  • Operating Pressure (PSI)
  • 0 to 101 psig @ 266°F 0 to 217 psig @ 77°F
  • Operating Temperature (Celsius)
  • 0 °C - 130 °C
  • Operating Temperature (Fahrenheit)
  • 32 °F - 266 °F
  • pH Range
  • 0 – 14
  • pH Sensing Technology
  • Highly Alkali Resistant Glass Membrane for Tough Conditions (HA)
  • Primary Media/Application
  • Chemical Processes
  • Process Connection
  • Pg 13.5 Thread
  • Reference System
  • Xerolyt Extra polymer electrolyte, open double junction, Argenthal cartridge with silver-ion trap
  • Refillable Electrolyte
  • No
  • Sensor Length
  • 425 mm
  • Shaft Material
  • Glass
  • Sterilizable/Autoclavable
  • No
  • Temperature Sensor
  • Pt 100
METL52002993 pH Sensor InPro4260/425/PT1000 Special offer 
Add to Cart
  • Cable Connector
  • VP
  • Certificates & Approvals
  • CE METTLER TOLEDO Quality Certificate FM: IS Cl. I, II, III, Div 1, GR ABCDEFG/T6 ATEX/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb PED
  • Connection
  • Pg 13.5 Thread
  • Hazardous Area Approvals
  • Yes
  • Hygienic/Biocompatibility Approvals
  • No
  • ISM (Digital) or Analog
  • Analog
  • Measurement Parameter
  • pH
  • Model Family
  • InPro4260(i)
  • Operating Pressure (Bar)
  • 0 to 15 barg @ 25°C 0 to 7 barg @ 130°C
  • Operating Pressure (PSI)
  • 0 to 101 psig @ 266°F 0 to 217 psig @ 77°F
  • Operating Temperature (Celsius)
  • 0 °C - 130 °C
  • Operating Temperature (Fahrenheit)
  • 32 °F - 266 °F
  • pH Range
  • 0 – 14
  • pH Sensing Technology
  • Highly Alkali Resistant Glass Membrane for Tough Conditions (HA)
  • Primary Media/Application
  • Chemical Processes
  • Process Connection
  • Pg 13.5 Thread
  • Reference System
  • Xerolyt Extra polymer electrolyte, open double junction, Argenthal cartridge with silver-ion trap
  • Refillable Electrolyte
  • No
  • Sensor Length
  • 425 mm
  • Shaft Material
  • Glass
  • Sterilizable/Autoclavable
  • No
  • Temperature Sensor
  • PT 1000
METL52003545 pH Sensor InPro4260/SG/120/PT100 Special offer 
Add to Cart
  • Cable Connector
  • VP
  • Certificates & Approvals
  • CE METTLER TOLEDO Quality Certificate FM: IS Cl. I, II, III, Div 1, GR ABCDEFG/T6 ATEX/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb PED
  • Connection
  • Pg 13.5 Thread
  • Hazardous Area Approvals
  • Yes
  • Hygienic/Biocompatibility Approvals
  • No
  • ISM (Digital) or Analog
  • Analog
  • Measurement Parameter
  • pH ORP/Redox
  • Model Family
  • InPro4260(i)
  • Operating Pressure (Bar)
  • 0 to 15 barg @ 25°C 0 to 7 barg @ 130°C
  • Operating Pressure (PSI)
  • 0 to 101 psig @ 266°F 0 to 217 psig @ 77°F
  • Operating Temperature (Celsius)
  • 0 °C - 130 °C
  • Operating Temperature (Fahrenheit)
  • 32 °F - 266 °F
  • pH Range
  • 0 – 14
  • pH Sensing Technology
  • Highly Alkali Resistant Glass Membrane for Tough Conditions (HA)
  • Primary Media/Application
  • Chemical Processes
  • Process Connection
  • Pg 13.5 Thread
  • Reference System
  • Xerolyt Extra polymer electrolyte, open double junction, Argenthal cartridge with silver-ion trap
  • Refillable Electrolyte
  • No
  • Sensor Length
  • 120 mm
  • Shaft Material
  • Glass
  • Sterilizable/Autoclavable
  • No
  • Temperature Sensor
  • Pt 100
METL52003546 pH Sensor InPro4260/SG/120/PT1000 Special offer 
Add to Cart
  • Cable Connector
  • VP
  • Certificates & Approvals
  • CE METTLER TOLEDO Quality Certificate FM: IS Cl. I, II, III, Div 1, GR ABCDEFG/T6 ATEX/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb PED
  • Connection
  • Pg 13.5 Thread
  • Hazardous Area Approvals
  • Yes
  • Hygienic/Biocompatibility Approvals
  • No
  • ISM (Digital) or Analog
  • Analog
  • Measurement Parameter
  • pH ORP/Redox
  • Model Family
  • InPro4260(i)
  • Operating Pressure (Bar)
  • 0 to 15 barg @ 25°C 0 to 7 barg @ 130°C
  • Operating Pressure (PSI)
  • 0 to 101 psig @ 266°F 0 to 217 psig @ 77°F
  • Operating Temperature (Celsius)
  • 0 °C - 130 °C
  • Operating Temperature (Fahrenheit)
  • 32 °F - 266 °F
  • pH Range
  • 0 – 14
  • pH Sensing Technology
  • Highly Alkali Resistant Glass Membrane for Tough Conditions (HA)
  • Primary Media/Application
  • Chemical Processes
  • Process Connection
  • Pg 13.5 Thread
  • Reference System
  • Xerolyt Extra polymer electrolyte, open double junction, Argenthal cartridge with silver-ion trap
  • Refillable Electrolyte
  • No
  • Sensor Length
  • 120 mm
  • Shaft Material
  • Glass
  • Sterilizable/Autoclavable
  • No
  • Temperature Sensor
  • PT 1000