METL52005380 |
pH Sensor InPro3253i/SG/425
|
Special offer
|
Add to Cart
|
- Cable Connector
- K8S
- Certificates & Approvals
- CE METTLER TOLEDO Quality Certificate FM: IS Cl. I, II, III, Div 1, GR ABCDEFG/T6 EHEDG ATEX/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb PED
- Connection
- Pg 13.5 Thread
- Hazardous Area Approvals
- Yes
- Hygienic/Biocompatibility Approvals
- Yes
- ISM (Digital) or Analog
- ISM (Digital)
- Measurement Parameter
- pH ORP/Redox
- Model Family
- InPro3250(i)
- Operating Pressure (Bar)
- 0 to 4 barg
- Operating Pressure (PSI)
- 0 to 58 psig
- Operating Temperature (Celsius)
- 0 °C - 100 °C
- Operating Temperature (Fahrenheit)
- 32 °F - 212 °F
- pH Range
- 0 – 12
- pH Sensing Technology
- Steam Sterilizable Glass Membrane (A41)
- Primary Media/Application
- Pharmaceutical/Life Science Production
- Process Connection
- Pg 13.5 Thread
- Reference System
- Pre-pressurized liquid electrolyte, ceramic diaphragm, Argenthal cartridge with silver-ion trap
- Refillable Electrolyte
- No
- Sensor Length
- 425 mm
- Shaft Material
- Glass
- Sterilizable/Autoclavable
- Yes
- Temperature Sensor
- Digital
|
|
METL52002576 |
pH Sensor InPro3253/SG/120/PT100
|
Special offer
|
Add to Cart
|
- Cable Connector
- VP
- Certificates & Approvals
- CE METTLER TOLEDO Quality Certificate FM: IS Cl. I, II, III, Div 1, GR ABCDEFG/T6 EHEDG ATEX/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb PED
- Connection
- Pg 13.5 Thread
- Hazardous Area Approvals
- Yes
- Hygienic/Biocompatibility Approvals
- Yes
- ISM (Digital) or Analog
- Analog
- Measurement Parameter
- pH ORP/Redox
- Model Family
- InPro3250(i)
- Operating Pressure (Bar)
- 0 to 4 barg
- Operating Pressure (PSI)
- 0 to 58 psig
- Operating Temperature (Celsius)
- 0 °C - 100 °C
- Operating Temperature (Fahrenheit)
- 32 °F - 212 °F
- pH Range
- 0 – 12
- pH Sensing Technology
- Steam Sterilizable Glass Membrane (A41)
- Primary Media/Application
- Pharmaceutical/Life Science Production
- Process Connection
- Pg 13.5 Thread
- Reference System
- Pre-pressurized liquid electrolyte, ceramic diaphragm, Argenthal cartridge with silver-ion trap
- Refillable Electrolyte
- No
- Sensor Length
- 120 mm
- Shaft Material
- Glass
- Sterilizable/Autoclavable
- Yes
- Temperature Sensor
- Pt 100
|
|
METL52002577 |
pH Sensor InPro3253/SG/120/PT1000
|
Special offer
|
Add to Cart
|
- Cable Connector
- VP
- Certificates & Approvals
- CE METTLER TOLEDO Quality Certificate FM: IS Cl. I, II, III, Div 1, GR ABCDEFG/T6 EHEDG ATEX/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb PED
- Connection
- Pg 13.5 Thread
- Hazardous Area Approvals
- Yes
- Hygienic/Biocompatibility Approvals
- Yes
- ISM (Digital) or Analog
- Analog
- Measurement Parameter
- pH ORP/Redox
- Model Family
- InPro3250(i)
- Operating Pressure (Bar)
- 0 to 4 barg
- Operating Pressure (PSI)
- 0 to 58 psig
- Operating Temperature (Celsius)
- 0 °C - 100 °C
- Operating Temperature (Fahrenheit)
- 32 °F - 212 °F
- pH Range
- 0 – 12
- pH Sensing Technology
- Steam Sterilizable Glass Membrane (A41)
- Primary Media/Application
- Pharmaceutical/Life Science Production
- Process Connection
- Pg 13.5 Thread
- Reference System
- Pre-pressurized liquid electrolyte, ceramic diaphragm, Argenthal cartridge with silver-ion trap
- Refillable Electrolyte
- No
- Sensor Length
- 120 mm
- Shaft Material
- Glass
- Sterilizable/Autoclavable
- Yes
- Temperature Sensor
- PT 1000
|
|
METL52002578 |
pH Sensor InPro3253/SG/225/PT100
|
Special offer
|
Add to Cart
|
- Cable Connector
- VP
- Certificates & Approvals
- CE METTLER TOLEDO Quality Certificate FM: IS Cl. I, II, III, Div 1, GR ABCDEFG/T6 EHEDG ATEX/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb PED
- Connection
- Pg 13.5 Thread
- Hazardous Area Approvals
- Yes
- Hygienic/Biocompatibility Approvals
- Yes
- ISM (Digital) or Analog
- Analog
- Measurement Parameter
- pH ORP/Redox
- Model Family
- InPro3250(i)
- Operating Pressure (Bar)
- 0 to 4 barg
- Operating Pressure (PSI)
- 0 to 58 psig
- Operating Temperature (Celsius)
- 0 °C - 100 °C
- Operating Temperature (Fahrenheit)
- 32 °F - 212 °F
- pH Range
- 0 – 12
- pH Sensing Technology
- Steam Sterilizable Glass Membrane (A41)
- Primary Media/Application
- Pharmaceutical/Life Science Production
- Process Connection
- Pg 13.5 Thread
- Reference System
- Pre-pressurized liquid electrolyte, ceramic diaphragm, Argenthal cartridge with silver-ion trap
- Refillable Electrolyte
- No
- Sensor Length
- 225 mm
- Shaft Material
- Glass
- Sterilizable/Autoclavable
- Yes
- Temperature Sensor
- Pt 100
|
|
METL52002579 |
pH Sensor InPro3253/SG/225/PT1000
|
Special offer
|
Add to Cart
|
- Cable Connector
- VP
- Certificates & Approvals
- CE METTLER TOLEDO Quality Certificate FM: IS Cl. I, II, III, Div 1, GR ABCDEFG/T6 EHEDG ATEX/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb PED
- Connection
- Pg 13.5 Thread
- Hazardous Area Approvals
- Yes
- Hygienic/Biocompatibility Approvals
- Yes
- ISM (Digital) or Analog
- Analog
- Measurement Parameter
- pH ORP/Redox
- Model Family
- InPro3250(i)
- Operating Pressure (Bar)
- 0 to 4 barg
- Operating Pressure (PSI)
- 0 to 58 psig
- Operating Temperature (Celsius)
- 0 °C - 100 °C
- Operating Temperature (Fahrenheit)
- 32 °F - 212 °F
- pH Range
- 0 – 12
- pH Sensing Technology
- Steam Sterilizable Glass Membrane (A41)
- Primary Media/Application
- Pharmaceutical/Life Science Production
- Process Connection
- Pg 13.5 Thread
- Reference System
- Pre-pressurized liquid electrolyte, ceramic diaphragm, Argenthal cartridge with silver-ion trap
- Refillable Electrolyte
- No
- Sensor Length
- 225 mm
- Shaft Material
- Glass
- Sterilizable/Autoclavable
- Yes
- Temperature Sensor
- PT 1000
|
|
METL52002580 |
pH Sensor InPro3253/SG/325/PT100
|
Special offer
|
Add to Cart
|
- Cable Connector
- VP
- Certificates & Approvals
- CE METTLER TOLEDO Quality Certificate FM: IS Cl. I, II, III, Div 1, GR ABCDEFG/T6 EHEDG ATEX/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb PED
- Connection
- Pg 13.5 Thread
- Hazardous Area Approvals
- Yes
- Hygienic/Biocompatibility Approvals
- Yes
- ISM (Digital) or Analog
- Analog
- Measurement Parameter
- pH ORP/Redox
- Model Family
- InPro3250(i)
- Operating Pressure (Bar)
- 0 to 4 barg
- Operating Pressure (PSI)
- 0 to 58 psig
- Operating Temperature (Celsius)
- 0 °C - 100 °C
- Operating Temperature (Fahrenheit)
- 32 °F - 212 °F
- pH Range
- 0 – 12
- pH Sensing Technology
- Steam Sterilizable Glass Membrane (A41)
- Primary Media/Application
- Pharmaceutical/Life Science Production
- Process Connection
- Pg 13.5 Thread
- Reference System
- Pre-pressurized liquid electrolyte, ceramic diaphragm, Argenthal cartridge with silver-ion trap
- Refillable Electrolyte
- No
- Sensor Length
- 325 mm
- Shaft Material
- Glass
- Sterilizable/Autoclavable
- Yes
- Temperature Sensor
- Pt 100
|
|
METL52002581 |
pH Sensor InPro3253/SG/325/PT1000
|
Special offer
|
Add to Cart
|
- Cable Connector
- VP
- Certificates & Approvals
- CE METTLER TOLEDO Quality Certificate FM: IS Cl. I, II, III, Div 1, GR ABCDEFG/T6 EHEDG ATEX/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb PED
- Connection
- Pg 13.5 Thread
- Hazardous Area Approvals
- Yes
- Hygienic/Biocompatibility Approvals
- Yes
- ISM (Digital) or Analog
- Analog
- Measurement Parameter
- pH ORP/Redox
- Model Family
- InPro3250(i)
- Operating Pressure (Bar)
- 0 to 4 barg
- Operating Pressure (PSI)
- 0 to 58 psig
- Operating Temperature (Celsius)
- 0 °C - 100 °C
- Operating Temperature (Fahrenheit)
- 32 °F - 212 °F
- pH Range
- 0 – 12
- pH Sensing Technology
- Steam Sterilizable Glass Membrane (A41)
- Primary Media/Application
- Pharmaceutical/Life Science Production
- Process Connection
- Pg 13.5 Thread
- Reference System
- Pre-pressurized liquid electrolyte, ceramic diaphragm, Argenthal cartridge with silver-ion trap
- Refillable Electrolyte
- No
- Sensor Length
- 325 mm
- Shaft Material
- Glass
- Sterilizable/Autoclavable
- Yes
- Temperature Sensor
- PT 1000
|
|
METL52002582 |
pH Sensor InPro3253/SG/425/PT100
|
Special offer
|
Add to Cart
|
- Cable Connector
- VP
- Certificates & Approvals
- CE METTLER TOLEDO Quality Certificate FM: IS Cl. I, II, III, Div 1, GR ABCDEFG/T6 EHEDG ATEX/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb PED
- Connection
- Pg 13.5 Thread
- Hazardous Area Approvals
- Yes
- Hygienic/Biocompatibility Approvals
- Yes
- ISM (Digital) or Analog
- Analog
- Measurement Parameter
- pH ORP/Redox
- Model Family
- InPro3250(i)
- Operating Pressure (Bar)
- 0 to 4 barg
- Operating Pressure (PSI)
- 0 to 58 psig
- Operating Temperature (Celsius)
- 0 °C - 100 °C
- Operating Temperature (Fahrenheit)
- 32 °F - 212 °F
- pH Range
- 0 – 12
- pH Sensing Technology
- Steam Sterilizable Glass Membrane (A41)
- Primary Media/Application
- Pharmaceutical/Life Science Production
- Process Connection
- Pg 13.5 Thread
- Reference System
- Pre-pressurized liquid electrolyte, ceramic diaphragm, Argenthal cartridge with silver-ion trap
- Refillable Electrolyte
- No
- Sensor Length
- 425 mm
- Shaft Material
- Glass
- Sterilizable/Autoclavable
- Yes
- Temperature Sensor
- Pt 100
|
|
METL52002583 |
pH Sensor InPro3253/SG/425/PT1000
|
Special offer
|
Add to Cart
|
- Cable Connector
- VP
- Certificates & Approvals
- CE METTLER TOLEDO Quality Certificate FM: IS Cl. I, II, III, Div 1, GR ABCDEFG/T6 EHEDG ATEX/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb PED
- Connection
- Pg 13.5 Thread
- Hazardous Area Approvals
- Yes
- Hygienic/Biocompatibility Approvals
- Yes
- ISM (Digital) or Analog
- Analog
- Measurement Parameter
- pH ORP/Redox
- Model Family
- InPro3250(i)
- Operating Pressure (Bar)
- 0 to 4 barg
- Operating Pressure (PSI)
- 0 to 58 psig
- Operating Temperature (Celsius)
- 0 °C - 100 °C
- Operating Temperature (Fahrenheit)
- 32 °F - 212 °F
- pH Range
- 0 – 12
- pH Sensing Technology
- Steam Sterilizable Glass Membrane (A41)
- Primary Media/Application
- Pharmaceutical/Life Science Production
- Process Connection
- Pg 13.5 Thread
- Reference System
- Pre-pressurized liquid electrolyte, ceramic diaphragm, Argenthal cartridge with silver-ion trap
- Refillable Electrolyte
- No
- Sensor Length
- 425 mm
- Shaft Material
- Glass
- Sterilizable/Autoclavable
- Yes
- Temperature Sensor
- PT 1000
|
|
METL52000510 |
pH Sensor InPro4010/120
|
Special offer
|
Add to Cart
|
- Cable Connector
- VP
- Certificates & Approvals
- CE METTLER TOLEDO Quality Certificate PED
- Connection
- Pg 13.5 Thread
- Hazardous Area Approvals
- No
- Hygienic/Biocompatibility Approvals
- No
- ISM (Digital) or Analog
- Analog
- Measurement Parameter
- pH
- Model Family
- InPro 4010
- Operating Pressure (Bar)
- 0 to 1 barg @ 60°C
- Operating Pressure (PSI)
- 0 to 15 psig @ 140°F
- Operating Temperature (Celsius)
- 0 °C - 60 °C
- Operating Temperature (Fahrenheit)
- 32 °F - 140 °F
- pH Range
- 2 – 12
- pH Sensing Technology
- General Purpose Glass Membrane
- Primary Media/Application
- Wastewater
- Process Connection
- Pg 13.5 Thread
- Reference System
- Xerolyt® polymer electrolyte, open double junction, Argenthal cartridge with silver-ion trap
- Refillable Electrolyte
- No
- Sensor Length
- 120 mm
- Shaft Material
- PEEK
- Sterilizable/Autoclavable
- No
- Temperature Sensor
- No
|