+852-3069 6950
css@gugent.com.hk
 

Process Analytics


Process Instrumentation for measuring pH, Dissolved Oxygen, Conductivity, Turbidity, TOC, Sodium, Silica, Gas Analyzer


Catalog No. Product Net Price
METL52003554 pH Sensor InPro4262/425/PT1000 Special offer 
Add to Cart
  • Cable Connector
  • VP
  • Certificates & Approvals
  • CE METTLER TOLEDO Quality Certificate FM: IS Cl. I, II, III, Div 1, GR ABCDEFG/T6 ATEX/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb PED
  • Connection
  • Pg 13.5 Thread
  • Hazardous Area Approvals
  • Yes
  • Hygienic/Biocompatibility Approvals
  • No
  • ISM (Digital) or Analog
  • Analog
  • Measurement Parameter
  • pH
  • Model Family
  • InPro4260(i)
  • Operating Pressure (Bar)
  • 0 to 15 barg @ 25°C 0 to 7 barg @ 130°C
  • Operating Pressure (PSI)
  • 0 to 101 psig @ 266°F 0 to 217 psig @ 77°F
  • Operating Temperature (Celsius)
  • 0 °C - 130 °C
  • Operating Temperature (Fahrenheit)
  • 32 °F - 266 °F
  • pH Range
  • 1 – 14
  • pH Sensing Technology
  • Hydrofluoric Acid Resistant Glass Membrane (HF)
  • Primary Media/Application
  • Chemical Processes
  • Process Connection
  • Pg 13.5 Thread
  • Reference System
  • Xerolyt Extra polymer electrolyte, open double junction, Argenthal cartridge with silver-ion trap
  • Refillable Electrolyte
  • No
  • Sensor Length
  • 425 mm
  • Shaft Material
  • Glass
  • Sterilizable/Autoclavable
  • No
  • Temperature Sensor
  • PT 1000
METL30018467 pH Sensor InPro4262i/SG/120 Special offer 
Add to Cart
  • Cable Connector
  • K8S
  • Certificates & Approvals
  • CE METTLER TOLEDO Quality Certificate FM: IS Cl. I, II, III, Div 1, GR ABCDEFG/T6 ATEX/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb PED
  • Connection
  • Pg 13.5 Thread
  • Hazardous Area Approvals
  • Yes
  • Hygienic/Biocompatibility Approvals
  • No
  • ISM (Digital) or Analog
  • ISM (Digital)
  • Measurement Parameter
  • pH ORP/Redox
  • Model Family
  • InPro4260(i)
  • Operating Pressure (Bar)
  • 0 to 15 barg @ 25°C 0 to 7 barg @ 130°C
  • Operating Pressure (PSI)
  • 0 to 101 psig @ 266°F 0 to 217 psig @ 77°F
  • Operating Temperature (Celsius)
  • 0 °C - 80 °C
  • Operating Temperature (Fahrenheit)
  • 32 °F - 176 °F
  • pH Range
  • 1 – 11
  • pH Sensing Technology
  • Hydrofluoric Acid Resistant Glass Membrane (HF)
  • Primary Media/Application
  • Chemical Processes
  • Process Connection
  • Pg 13.5 Thread
  • Reference System
  • Xerolyt Extra polymer electrolyte, open double junction, Argenthal cartridge with silver-ion trap
  • Refillable Electrolyte
  • No
  • Sensor Length
  • 120 mm
  • Shaft Material
  • Glass
  • Sterilizable/Autoclavable
  • No
  • Temperature Sensor
  • Digital
METL30018468 pH Sensor InPro4262i/SG/225 Special offer 
Add to Cart
  • Cable Connector
  • K8S
  • Certificates & Approvals
  • CE METTLER TOLEDO Quality Certificate FM: IS Cl. I, II, III, Div 1, GR ABCDEFG/T6 ATEX/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb PED
  • Connection
  • Pg 13.5 Thread
  • Hazardous Area Approvals
  • Yes
  • Hygienic/Biocompatibility Approvals
  • No
  • ISM (Digital) or Analog
  • ISM (Digital)
  • Measurement Parameter
  • pH ORP/Redox
  • Model Family
  • InPro4260(i)
  • Operating Pressure (Bar)
  • 0 to 15 barg @ 25°C 0 to 7 barg @ 130°C
  • Operating Pressure (PSI)
  • 0 to 101 psig @ 266°F 0 to 217 psig @ 77°F
  • Operating Temperature (Celsius)
  • 0 °C - 80 °C
  • Operating Temperature (Fahrenheit)
  • 32 °F - 176 °F
  • pH Range
  • 1 – 11
  • pH Sensing Technology
  • Hydrofluoric Acid Resistant Glass Membrane (HF)
  • Primary Media/Application
  • Chemical Processes
  • Process Connection
  • Pg 13.5 Thread
  • Reference System
  • Xerolyt Extra polymer electrolyte, open double junction, Argenthal cartridge with silver-ion trap
  • Refillable Electrolyte
  • No
  • Sensor Length
  • 225 mm
  • Shaft Material
  • Glass
  • Sterilizable/Autoclavable
  • No
  • Temperature Sensor
  • Digital
METL30301402 pH Sensor InPro4281i/SG/120 Special offer 
Add to Cart
  • Cable Connector
  • K8S
  • Certificates & Approvals
  • CE METTLER TOLEDO Quality Certificate FM: IS Cl. I, II, III, Div 1, GR ABCDEFG/T6 ATEX/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb PED
  • Connection
  • Pg 13.5 Thread
  • Hazardous Area Approvals
  • Yes
  • Hygienic/Biocompatibility Approvals
  • No
  • ISM (Digital) or Analog
  • ISM (Digital)
  • Measurement Parameter
  • pH
  • Model Family
  • InPro4260(i)
  • Operating Pressure (Bar)
  • 0 to 15 barg @ 25°C
  • Operating Pressure (PSI)
  • 0 to 217 psig @ 77°F
  • Operating Temperature (Celsius)
  • 0 °C - 80 °C
  • Operating Temperature (Fahrenheit)
  • 32 °F - 176 °F
  • pH Range
  • 1 – 14
  • pH Sensing Technology
  • Glass Membrane Suitable For Low Temperatures (LoT)
  • Primary Media/Application
  • Chemical Processes
  • Process Connection
  • Pg 13.5 Thread
  • Reference System
  • Xerolyt Extra polymer electrolyte, open double junction, Argenthal cartridge with silver-ion trap
  • Refillable Electrolyte
  • No
  • Sensor Length
  • 120 mm
  • Shaft Material
  • Titanium
  • Sterilizable/Autoclavable
  • No
  • Temperature Sensor
  • Digital
METL30301403 pH Sensor InPro4281i/SG/225 Special offer 
Add to Cart
  • Cable Connector
  • K8S
  • Certificates & Approvals
  • CE METTLER TOLEDO Quality Certificate FM: IS Cl. I, II, III, Div 1, GR ABCDEFG/T6 ATEX/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb PED
  • Connection
  • Pg 13.5 Thread
  • Hazardous Area Approvals
  • Yes
  • Hygienic/Biocompatibility Approvals
  • No
  • ISM (Digital) or Analog
  • ISM (Digital)
  • Measurement Parameter
  • pH
  • Model Family
  • InPro4260(i)
  • Operating Pressure (Bar)
  • 0 to 15 barg @ 25°C
  • Operating Pressure (PSI)
  • 0 to 217 psig @ 77°F
  • Operating Temperature (Celsius)
  • 0 °C - 80 °C
  • Operating Temperature (Fahrenheit)
  • 32 °F - 176 °F
  • pH Range
  • 1 – 14
  • pH Sensing Technology
  • Glass Membrane Suitable For Low Temperatures (LoT)
  • Primary Media/Application
  • Chemical Processes
  • Process Connection
  • Pg 13.5 Thread
  • Reference System
  • Xerolyt® polymer electrolyte, open double junction, Argenthal cartridge with silver-ion trap
  • Refillable Electrolyte
  • No
  • Sensor Length
  • 225 mm
  • Shaft Material
  • Titanium
  • Sterilizable/Autoclavable
  • No
  • Temperature Sensor
  • Digital
METL30301404 pH Sensor InPro4281i/SG/425 Special offer 
Add to Cart
  • Cable Connector
  • K8S
  • Certificates & Approvals
  • CE METTLER TOLEDO Quality Certificate FM: IS Cl. I, II, III, Div 1, GR ABCDEFG/T6 ATEX/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb PED
  • Connection
  • Pg 13.5 Thread
  • Hazardous Area Approvals
  • Yes
  • Hygienic/Biocompatibility Approvals
  • No
  • ISM (Digital) or Analog
  • ISM (Digital)
  • Measurement Parameter
  • pH
  • Model Family
  • InPro4260(i)
  • Operating Pressure (Bar)
  • 0 to 15 barg @ 25°C
  • Operating Pressure (PSI)
  • 0 to 217 psig @ 77°F
  • Operating Temperature (Celsius)
  • 0 °C - 80 °C
  • Operating Temperature (Fahrenheit)
  • 32 °F - 176 °F
  • pH Range
  • 1 – 14
  • pH Sensing Technology
  • Glass Membrane Suitable For Low Temperatures (LoT)
  • Primary Media/Application
  • Chemical Processes
  • Process Connection
  • Pg 13.5 Thread
  • Reference System
  • Xerolyt® polymer electrolyte, open double junction, Argenthal cartridge with silver-ion trap
  • Refillable Electrolyte
  • No
  • Sensor Length
  • 425 mm
  • Shaft Material
  • Titanium
  • Sterilizable/Autoclavable
  • No
  • Temperature Sensor
  • Digital
METL59909542 pH Sensor InPro4501/PT100/SG/3m/S/T Special offer 
Add to Cart
  • Cable Connector
  • Fixed cable 3 m
  • Certificates & Approvals
  • CE METTLER TOLEDO Quality Certificate FM: IS Cl. I, II, III, Div 1, GR ABCDEFG/T6 ATEX/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb PED
  • Connection
  • 1 inch NPT
  • Hazardous Area Approvals
  • Yes
  • Hygienic/Biocompatibility Approvals
  • No
  • ISM (Digital) or Analog
  • Analog
  • Measurement Parameter
  • pH
  • Model Family
  • InPro4500
  • Operating Pressure (Bar)
  • 0 to 6 barg @ 65 °C
  • Operating Pressure (PSI)
  • 0 to 87 psig @ 149 °F
  • Operating Temperature (Celsius)
  • 0 °C - 100 °C
  • Operating Temperature (Fahrenheit)
  • 32 °F - 212 °F
  • pH Range
  • 1 – 14
  • pH Sensing Technology
  • Glass Membrane Suitable For Low Temperatures (LoT)
  • Primary Media/Application
  • Chemical Processes
  • Process Connection
  • 1 inch NPT
  • Reference System
  • Xerolyt Extra polymer electrolyte, open double junction, Argenthal cartridge with silver-ion trap
  • Refillable Electrolyte
  • No
  • Sensor Length
  • 72.5 mm
  • Shaft Material
  • PVDF
  • Sterilizable/Autoclavable
  • No
  • Temperature Sensor
  • Pt 100
METL59909543 pH Sensor InPro4501/PT100/SG/3m/BNC Special offer 
Add to Cart
  • Cable Connector
  • Fixed cable 3 m with BNC
  • Certificates & Approvals
  • CE METTLER TOLEDO Quality Certificate FM: IS Cl. I, II, III, Div 1, GR ABCDEFG/T6 ATEX/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb PED
  • Connection
  • 1 inch NPT
  • Hazardous Area Approvals
  • Yes
  • Hygienic/Biocompatibility Approvals
  • No
  • ISM (Digital) or Analog
  • Analog
  • Measurement Parameter
  • pH
  • Model Family
  • InPro4500
  • Operating Pressure (Bar)
  • 0 to 6 barg @ 65 °C
  • Operating Pressure (PSI)
  • 0 to 87 psig @ 149 °F
  • Operating Temperature (Celsius)
  • 0 °C - 100 °C
  • Operating Temperature (Fahrenheit)
  • 32 °F - 212 °F
  • pH Range
  • 1 – 14
  • pH Sensing Technology
  • Glass Membrane Suitable For Low Temperatures (LoT)
  • Primary Media/Application
  • Chemical Processes
  • Process Connection
  • 1 inch NPT
  • Reference System
  • Xerolyt Extra polymer electrolyte, open double junction, Argenthal cartridge with silver-ion trap
  • Refillable Electrolyte
  • No
  • Sensor Length
  • 72.5 mm
  • Shaft Material
  • PVDF
  • Sterilizable/Autoclavable
  • No
  • Temperature Sensor
  • Pt 100
METL59909545 pH Sensor InPro4501/1000/SG/3m/S/T Special offer 
Add to Cart
  • Cable Connector
  • Fixed cable 3 m
  • Certificates & Approvals
  • CE METTLER TOLEDO Quality Certificate FM: IS Cl. I, II, III, Div 1, GR ABCDEFG/T6 ATEX/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb PED
  • Connection
  • 1 inch NPT
  • Hazardous Area Approvals
  • Yes
  • Hygienic/Biocompatibility Approvals
  • No
  • ISM (Digital) or Analog
  • Analog
  • Measurement Parameter
  • pH
  • Model Family
  • InPro4500
  • Operating Pressure (Bar)
  • 0 to 6 barg @ 65 °C
  • Operating Pressure (PSI)
  • 0 to 87 psig @ 149 °F
  • Operating Temperature (Celsius)
  • 0 °C - 100 °C
  • Operating Temperature (Fahrenheit)
  • 32 °F - 212 °F
  • pH Range
  • 1 – 14
  • pH Sensing Technology
  • Glass Membrane Suitable For Low Temperatures (LoT)
  • Primary Media/Application
  • Chemical Processes
  • Process Connection
  • 1 inch NPT
  • Reference System
  • Xerolyt Extra polymer electrolyte, open double junction, Argenthal cartridge with silver-ion trap
  • Refillable Electrolyte
  • No
  • Sensor Length
  • 72.5 mm
  • Shaft Material
  • PVDF
  • Sterilizable/Autoclavable
  • No
  • Temperature Sensor
  • PT 1000
METL59909546 pH Sensor InPro4501/100/SG/10m/S/T Special offer 
Add to Cart
  • Cable Connector
  • Fixed cable 10 m
  • Certificates & Approvals
  • CE METTLER TOLEDO Quality Certificate FM: IS Cl. I, II, III, Div 1, GR ABCDEFG/T6 ATEX/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb PED
  • Connection
  • 1 inch NPT
  • Hazardous Area Approvals
  • Yes
  • Hygienic/Biocompatibility Approvals
  • No
  • ISM (Digital) or Analog
  • Analog
  • Measurement Parameter
  • pH
  • Model Family
  • InPro4500
  • Operating Pressure (Bar)
  • 0 to 6 barg @ 65 °C
  • Operating Pressure (PSI)
  • 0 to 87 psig @ 149 °F
  • Operating Temperature (Celsius)
  • 0 °C - 100 °C
  • Operating Temperature (Fahrenheit)
  • 32 °F - 212 °F
  • pH Range
  • 1 – 14
  • pH Sensing Technology
  • Glass Membrane Suitable For Low Temperatures (LoT)
  • Primary Media/Application
  • Chemical Processes
  • Process Connection
  • 1 inch NPT
  • Reference System
  • Xerolyt Extra polymer electrolyte, open double junction, Argenthal cartridge with silver-ion trap
  • Refillable Electrolyte
  • No
  • Sensor Length
  • 72.5 mm
  • Shaft Material
  • PVDF
  • Sterilizable/Autoclavable
  • No
  • Temperature Sensor
  • Pt 100