P2B500V05
Pellicon® 2 Cassette with Biomax® 500 kDa Membrane, V screen, 0.5 m²
2115
Add to Cart
Catalogue Number
P2B500V05
Chemistry
Polyethersulfone (PES)
Device Configuration
Cassette
Device Material
Polypropylene and Polysulfone end cap
Filter Code
Biomax 500
Filter Type
Ultrafiltration
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 1500 mg/m² after a water flush.
Height
2.16 cm (0.85 in.)
Key Applications
Protein PurificationAnalytical Sample Prep
Length
20.6 cm (8.1 in)
Material Size
1
Maximum Operating Temperature
0 - 50°C
Maximum Transmembrane Pressure
Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
Media
Biomax®
Membrane Area
0.5 m²
NMWL
500 kDa
pH Range
pH1 – pH14
Recirculation Rate
7 to 10 L/min/m²
Screen Material
Polypropylene (PP)
Screen Type
Type V screen (open channel)
Trade Name
Pellicon®
Width
17.8 cm (7.0 in.)
P2C01MV05
Pellicon® 2 Cassette with Ultracel® 1000 kDa Membrane, V screen, 0.5 m²
2115
Add to Cart
Catalogue Number
P2C01MV05
Chemistry
Composite Regenerated Cellulose (CRC)
Device Configuration
Cassette
Device Material
Polypropylene and Polysulfone end cap
Filter Code
PLCXK
Filter Type
Ultrafiltration
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 1500 mg/m² after a water flush.
Height
2.16 cm (0.85 in.)
Key Applications
Protein PurificationAnalytical Sample Prep
Length
20.6 cm (8.1 in)
Material Size
1
Maximum Operating Temperature
0 - 30°C
Maximum Transmembrane Pressure
Forward: 3.4 bar (50 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
Media
Ultracel®
Membrane Area
0.5 m²
NMWL
1000 kDa
pH Range
pH2 – pH13
Recirculation Rate
7 to 10 L/min/m²
Screen Material
Polypropylene (PP)
Screen Type
Type V screen (open channel)
Trade Name
Pellicon®
Width
17.8 cm (7.0 in.)
P2C01MV05
Pellicon® 2 Cassette with Ultracel® 1000 kDa Membrane, V screen, 0.5 m²
2115
Add to Cart
Catalogue Number
P2C01MV05
Chemistry
Composite Regenerated Cellulose (CRC)
Device Configuration
Cassette
Device Material
Polypropylene and Polysulfone end cap
Filter Code
PLCXK
Filter Type
Ultrafiltration
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 1500 mg/m² after a water flush.
Height
2.16 cm (0.85 in.)
Key Applications
Protein PurificationAnalytical Sample Prep
Length
20.6 cm (8.1 in)
Material Size
1
Maximum Operating Temperature
0 - 30°C
Maximum Transmembrane Pressure
Forward: 3.4 bar (50 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
Media
Ultracel®
Membrane Area
0.5 m²
NMWL
1000 kDa
pH Range
pH2 – pH13
Recirculation Rate
7 to 10 L/min/m²
Screen Material
Polypropylene (PP)
Screen Type
Type V screen (open channel)
Trade Name
Pellicon®
Width
17.8 cm (7.0 in.)
P2C100V05
Pellicon® 2 Cassette with Ultracel® 100 kDa Membrane, V screen, 0.5 m²
2115
Add to Cart
Catalogue Number
P2C100V05
Chemistry
Composite Regenerated Cellulose (CRC)
Device Configuration
Cassette
Device Material
Polypropylene and Polysulfone end cap
Filter Code
PLCHK
Filter Type
Ultrafiltration
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 1500 mg/m² after a water flush.
Height
2.16 cm (0.85 in.)
Key Applications
Protein PurificationAnalytical Sample Prep
Length
20.6 cm (8.1 in)
Material Size
1
Maximum Operating Temperature
0 - 30°C
Maximum Transmembrane Pressure
Forward: 3.4 bar (50 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
Media
Ultracel®
Membrane Area
0.5 m²
NMWL
100 kDa
pH Range
pH2 – pH13
Recirculation Rate
7 to 10 L/min/m²
Screen Material
Polypropylene (PP)
Screen Type
Type V screen (open channel)
Trade Name
Pellicon®
Width
17.8 cm (7.0 in.)
P2C100V05
Pellicon® 2 Cassette with Ultracel® 100 kDa Membrane, V screen, 0.5 m²
2115
Add to Cart
Catalogue Number
P2C100V05
Chemistry
Composite Regenerated Cellulose (CRC)
Device Configuration
Cassette
Device Material
Polypropylene and Polysulfone end cap
Filter Code
PLCHK
Filter Type
Ultrafiltration
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 1500 mg/m² after a water flush.
Height
2.16 cm (0.85 in.)
Key Applications
Protein PurificationAnalytical Sample Prep
Length
20.6 cm (8.1 in)
Material Size
1
Maximum Operating Temperature
0 - 30°C
Maximum Transmembrane Pressure
Forward: 3.4 bar (50 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
Media
Ultracel®
Membrane Area
0.5 m²
NMWL
100 kDa
pH Range
pH2 – pH13
Recirculation Rate
7 to 10 L/min/m²
Screen Material
Polypropylene (PP)
Screen Type
Type V screen (open channel)
Trade Name
Pellicon®
Width
17.8 cm (7.0 in.)
P2C300V05
Pellicon® 2 Cassette with Ultracel® 300 kDa Membrane, V screen, 0.5 m²
2115
Add to Cart
Catalogue Number
P2C300V05
Chemistry
Composite Regenerated Cellulose (CRC)
Device Configuration
Cassette
Device Material
Polypropylene and Polysulfone end cap
Filter Code
PLCMK
Filter Type
Ultrafiltration
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 1500 mg/m² after a water flush.
Height
2.16 cm (0.85 in.)
Key Applications
Protein PurificationAnalytical Sample Prep
Length
20.6 cm (8.1 in)
Material Size
1
Maximum Operating Temperature
0 - 30°C
Maximum Transmembrane Pressure
Forward: 3.4 bar (50 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
Media
Ultracel®
Membrane Area
0.5 m²
NMWL
300 kDa
pH Range
pH2 – pH13
Recirculation Rate
7 to 10 L/min/m²
Screen Material
Polypropylene (PP)
Screen Type
Type V screen (open channel)
Trade Name
Pellicon®
Width
17.8 cm (7.0 in.)
P2C300V05
Pellicon® 2 Cassette with Ultracel® 300 kDa Membrane, V screen, 0.5 m²
2115
Add to Cart
Catalogue Number
P2C300V05
Chemistry
Composite Regenerated Cellulose (CRC)
Device Configuration
Cassette
Device Material
Polypropylene and Polysulfone end cap
Filter Code
PLCMK
Filter Type
Ultrafiltration
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 1500 mg/m² after a water flush.
Height
2.16 cm (0.85 in.)
Key Applications
Protein PurificationAnalytical Sample Prep
Length
20.6 cm (8.1 in)
Material Size
1
Maximum Operating Temperature
0 - 30°C
Maximum Transmembrane Pressure
Forward: 3.4 bar (50 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
Media
Ultracel®
Membrane Area
0.5 m²
NMWL
300 kDa
pH Range
pH2 – pH13
Recirculation Rate
7 to 10 L/min/m²
Screen Material
Polypropylene (PP)
Screen Type
Type V screen (open channel)
Trade Name
Pellicon®
Width
17.8 cm (7.0 in.)
CN1274V06
Polygard-CN Cartridge Filter 40 in. 1.2 µm Code 7 Fluoroelastomer
2116
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Code
Code 7 (2-226) O-rings w/locking-tabs
Cartridge Nominal Length
40 in. (100 cm)
Catalogue Number
CN1274V06
Chemistry
Polypropylene (PP)
Device Configuration
Cartridge
Device Material
Polypropylene
Diameter
7.0 cm (2.75 in.)
Filtration Area
1.68 m²
Gravimetric Extractables
≤200 mg after 24-h soak in water
Length
40 in. (100 cm)
Material Size
6
Maximum Differential Pressure, bar (psid)
4.8 bar (70 psid) @ 25 °C
Maximum Inlet Pressure, bar (psi)
4.8 bar (70 psi) @ 25 °C
Nominal Pore Size
1.2 µm
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥20 L
Pore Size
1.2 µm
Sanitization
30 min with hot water @ 80 °C
Seal Material
Fluorocarbon rubber
Sterilization
10 autoclave cycles or SIP @ 126 °C for 30 min
Trade Name
Polygard®
Wettability
Hydrophilic
CRK1F4006
Polygard-CR Cartridge Filter 40 in. 0.1 µm Code F
2124
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Code
Code F double open end w/flat gaskets
Cartridge Nominal Length
40 in. (100 cm)
Catalogue Number
CRK1F4006
Chemistry
Polypropylene (PP)
Device Configuration
Cartridge
Device Material
Polypropylene
Diameter
7.0 cm (2.75 in.)
Gravimetric Extractables
≤50 mg after 24-h soak in water
Length
40 in. (100 cm)
Material Size
6
Maximum Differential Pressure, bar (psid)
4.8 bar (70 psid) @ 25 °C
Maximum Inlet Pressure, bar (psi)
4.8 bar (70 psi) @ 25 °C
Nominal Pore Size
0.1 µm
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥20 L
Pore Size
1.0 µm
Sanitization
30 min with hot water @ 80 °C
Seal Material
Polyethylene (PE)
Sterilization
Do not autoclave
Trade Name
Polygard®
Wettability
Hydrophilic
CRK1F4006
Polygard-CR Cartridge Filter 40 in. 0.1 µm Code F
2124
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Code
Code F double open end w/flat gaskets
Cartridge Nominal Length
40 in. (100 cm)
Catalogue Number
CRK1F4006
Chemistry
Polypropylene (PP)
Device Configuration
Cartridge
Device Material
Polypropylene
Diameter
7.0 cm (2.75 in.)
Gravimetric Extractables
≤50 mg after 24-h soak in water
Length
40 in. (100 cm)
Material Size
6
Maximum Differential Pressure, bar (psid)
4.8 bar (70 psid) @ 25 °C
Maximum Inlet Pressure, bar (psi)
4.8 bar (70 psi) @ 25 °C
Nominal Pore Size
0.1 µm
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥20 L
Pore Size
1.0 µm
Sanitization
30 min with hot water @ 80 °C
Seal Material
Polyethylene (PE)
Sterilization
Do not autoclave
Trade Name
Polygard®
Wettability
Hydrophilic