+852-3069 6950
css@gugent.com.hk
 

We have developed a unique portfolio of consumables, each adapted to the different feed water quality requirements and to your various applications. To maintain your water system’s performance, it’s critical to replace your purification cartridges on time and with genuine ISO 9001-certified parts.

Catalog No. Product Net Price
P2PLACC05 Pellicon 2 Cassette Ultrafiltration Module PLAC C 0.5 m2 2126 
Add to Cart
  • Catalogue Number
  • P2PLACC05
  • Chemistry
  • Regenerated Cellulose (RC)
  • Device Configuration
  • Cassette
  • Device Size
  • 0.5 m²
  • Filter Code
  • PLAC
  • Filter Type
  • Ultrafiltration
  • Filtration Area
  • 0.5 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Height
  • 1.5 cm (0.6 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 21 cm (8.3 in.)
  • Material Size
  • 1
  • Maximum Transmembrane Pressure
  • 3.5 bar (50 psig) @ 30 °C
  • Media
  • Ultracel®
  • Membrane Area
  • 0.5 m²
  • NMWL
  • 1 kDa
  • Recirculation Rate
  • 5–35 L/min @ 0.4 bar (6 psi)
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type C screen (coarse screen)
  • Trade Name
  • Pellicon®
  • Width
  • 17.8 cm (7.0 in.)
P2PLACV05 Pellicon 2 Cassette Ultrafiltration Module PLAC V 0.5 m2 2126 
Add to Cart
  • Catalogue Number
  • P2PLACV05
  • Chemistry
  • Regenerated Cellulose (RC)
  • Device Configuration
  • Cassette
  • Device Size
  • 0.5 m²
  • Filter Code
  • PLAC
  • Filter Type
  • Ultrafiltration
  • Filtration Area
  • 0.5 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Height
  • 2.16 cm (0.85 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 21 cm (8.3 in.)
  • Material Size
  • 1
  • Maximum Transmembrane Pressure
  • 3.5 bar (50 psig) @ 30 °C
  • Media
  • Ultracel®
  • Membrane Area
  • 0.5 m²
  • NMWL
  • 1 kDa
  • Recirculation Rate
  • 5–35 L/min @ 0.4 bar (6 psi)
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type V screen (open channel)
  • Trade Name
  • Pellicon®
  • Width
  • 17.8 cm (7.0 in.)
CVML72TP3 Durapore® CVML Cartridge Filter 20 in. 0.1 µm Code 7 2138 
Add to Cart
  • Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Bacterial Retention
  • Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
  • Cartridge Code
  • Code 7 (2-226) O-rings w/locking-tabs
  • Cartridge Nominal Length
  • 20 in. (50 cm)
  • Catalogue Number
  • CVML72TP3
  • Chemistry
  • Polyvinylidene Fluoride (PVDF)
  • Device Configuration
  • Cartridge
  • Device Size
  • 20 in.
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 24 mg per 10-inch cartridge after 24 hours in water at controlled room temperature.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Length
  • 20 in. (50 cm)
  • Material Size
  • 3
  • Media
  • Durapore®
  • Non-Fiber Releasing
  • This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Sterility
  • Other
  • Trade Name
  • Durapore®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Wettability
  • Hydrophilic
P2B005V05 Pellicon® 2 Cassette with Biomax® 5 kDa Membrane, V screen, 0.5 m² 2140 
Add to Cart
  • Catalogue Number
  • P2B005V05
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene and Polysulfone end cap
  • Filter Code
  • Biomax 5
  • Filter Type
  • Ultrafiltration
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Height
  • 2.16 cm (0.85 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 20.6 cm (8.1 in)
  • Material Size
  • 1
  • Maximum Operating Temperature
  • 0 - 50°C
  • Maximum Transmembrane Pressure
  • Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
  • Media
  • Biomax®
  • Membrane Area
  • 0.5 m²
  • NMWL
  • 5 kDa
  • pH Range
  • pH1 – pH14
  • Recirculation Rate
  • 7 to 10 L/min/m²
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type V screen (open channel)
  • Trade Name
  • Pellicon®
  • Width
  • 17.8 cm (7.0 in.)
P2B005V05 Pellicon® 2 Cassette with Biomax® 5 kDa Membrane, V screen, 0.5 m² 2140 
Add to Cart
  • Catalogue Number
  • P2B005V05
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene and Polysulfone end cap
  • Filter Code
  • Biomax 5
  • Filter Type
  • Ultrafiltration
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Height
  • 2.16 cm (0.85 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 20.6 cm (8.1 in)
  • Material Size
  • 1
  • Maximum Operating Temperature
  • 0 - 50°C
  • Maximum Transmembrane Pressure
  • Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
  • Media
  • Biomax®
  • Membrane Area
  • 0.5 m²
  • NMWL
  • 5 kDa
  • pH Range
  • pH1 – pH14
  • Recirculation Rate
  • 7 to 10 L/min/m²
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type V screen (open channel)
  • Trade Name
  • Pellicon®
  • Width
  • 17.8 cm (7.0 in.)
CGEP73TE3 Millipore Express® SHF Cartridge Filter 30 in. 0.2 µm Code 7 EPDM 2146 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Bacterial Retention
  • Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
  • Cartridge Code
  • Code 7
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • CGEP73TE3
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene/Polysulfone
  • Device Size
  • 30 in.
  • Diameter
  • 6.9 cm (2.7 in.)
  • Filtration Area
  • 1.62 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Length
  • 30 in. (75 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 3
  • Maximum Differential Pressure
  • Forward: 6900 mbar (100 psi) @ 25 °C; 1700 bar (25 psi) @ 80 °C; 340 mbar (5 psi) @ 135 °C. Reverse: 2100 mbar (30 psi) @ 25 °C, 69 mbar (1 psi) @ 135 °C
  • Maximum Inlet Pressure, bar (psi)
  • Forward - 7 bar (100 psi) @ 25 °C; 1.7 bar (25 psi) @ 80 °C; 0.35 bar (5 psi) @ 135 °C; Reverse - 2.07 bar (30 psi) @ 25 °C; 0.07 bar (1 psi) @ 135 °C
  • Media
  • Millipore Express® SHF
  • Non-Fiber Releasing
  • This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥3 L
  • Pore Size
  • 0.2 µm
  • Seal Material
  • EPDM
  • Sterilization
  • 25 forward or 22 forward and 3 reverse SIP cycles of 30 min @ 135 °C; 25 autoclave cycles of 60 min @ 126 °C
  • Support Material
  • Polypropylene
  • Trade Name
  • Millipore Express®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Wettability
  • Hydrophilic
CGEP73TE3 Millipore Express® SHF Cartridge Filter 30 in. 0.2 µm Code 7 EPDM 2146 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Bacterial Retention
  • Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
  • Cartridge Code
  • Code 7
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • CGEP73TE3
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene/Polysulfone
  • Device Size
  • 30 in.
  • Diameter
  • 6.9 cm (2.7 in.)
  • Filtration Area
  • 1.62 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Length
  • 30 in. (75 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 3
  • Maximum Differential Pressure
  • Forward: 6900 mbar (100 psi) @ 25 °C; 1700 bar (25 psi) @ 80 °C; 340 mbar (5 psi) @ 135 °C. Reverse: 2100 mbar (30 psi) @ 25 °C, 69 mbar (1 psi) @ 135 °C
  • Maximum Inlet Pressure, bar (psi)
  • Forward - 7 bar (100 psi) @ 25 °C; 1.7 bar (25 psi) @ 80 °C; 0.35 bar (5 psi) @ 135 °C; Reverse - 2.07 bar (30 psi) @ 25 °C; 0.07 bar (1 psi) @ 135 °C
  • Media
  • Millipore Express® SHF
  • Non-Fiber Releasing
  • This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥3 L
  • Pore Size
  • 0.2 µm
  • Seal Material
  • EPDM
  • Sterilization
  • 25 forward or 22 forward and 3 reverse SIP cycles of 30 min @ 135 °C; 25 autoclave cycles of 60 min @ 126 °C
  • Support Material
  • Polypropylene
  • Trade Name
  • Millipore Express®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Wettability
  • Hydrophilic
P2B005A05 Pellicon® 2 Cassette with Biomax® 5 kDa Membrane, A screen, 0.5 m² 2147 
Add to Cart
  • Catalogue Number
  • P2B005A05
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • Biomax 5
  • Filter Type
  • Ultrafiltration
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Height
  • 1.5 cm (0.6 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 20.6 cm (8.1 in)
  • Material Size
  • 1
  • Maximum Operating Temperature
  • 0 - 50°C
  • Maximum Transmembrane Pressure
  • Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
  • Media
  • Biomax®
  • Membrane Area
  • 0.5 m²
  • NMWL
  • 5 kDa
  • pH Range
  • pH1 – pH14
  • Recirculation Rate
  • 4 to 7 L/min/m²
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type A screen (tight screen)
  • Trade Name
  • Pellicon®
  • Width
  • 17.8 cm (7.0 in.)
P2B005A05 Pellicon® 2 Cassette with Biomax® 5 kDa Membrane, A screen, 0.5 m² 2147 
Add to Cart
  • Catalogue Number
  • P2B005A05
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • Biomax 5
  • Filter Type
  • Ultrafiltration
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Height
  • 1.5 cm (0.6 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 20.6 cm (8.1 in)
  • Material Size
  • 1
  • Maximum Operating Temperature
  • 0 - 50°C
  • Maximum Transmembrane Pressure
  • Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
  • Media
  • Biomax®
  • Membrane Area
  • 0.5 m²
  • NMWL
  • 5 kDa
  • pH Range
  • pH1 – pH14
  • Recirculation Rate
  • 4 to 7 L/min/m²
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type A screen (tight screen)
  • Trade Name
  • Pellicon®
  • Width
  • 17.8 cm (7.0 in.)
P2B008A05 Pellicon® 2 Cassette with Biomax® 8 kDa Membrane, A screen, 0.5 m² 2147 
Add to Cart
  • Catalogue Number
  • P2B008A05
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • Biomax 8
  • Filter Type
  • Ultrafiltration
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Height
  • 1.5 cm (0.6 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 20.6 cm (8.1 in)
  • Material Size
  • 1
  • Maximum Operating Temperature
  • 0 - 50°C
  • Maximum Transmembrane Pressure
  • Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
  • Media
  • Biomax®
  • Membrane Area
  • 0.5 m²
  • NMWL
  • 8 kDa
  • pH Range
  • pH1 – pH14
  • Recirculation Rate
  • 4 to 7 L/min/m²
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type A screen (tight screen)
  • Trade Name
  • Pellicon®
  • Width
  • 17.8 cm (7.0 in.)

Overview

Analytical Sample Preparation Membrane Filtration Devices


Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.


Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.


Filter Membranes

Millex® Syringe Filters

Filtration Holders & Accessories



Resources