+852-3069 6950
css@gugent.com.hk
 

We have developed a unique portfolio of consumables, each adapted to the different feed water quality requirements and to your various applications. To maintain your water system’s performance, it’s critical to replace your purification cartridges on time and with genuine ISO 9001-certified parts.

Catalog No. Product Net Price
SK1M015W01 Pellicon® 2 Cassette with Biomax® 10 kDa Membrane, C screen, 0.5 m² 2062 
Add to Cart
  • Catalogue Number
  • SK1M015W01
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • Biomax 10
  • Filter Type
  • Ultrafiltration
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 20.6 cm (8.1 in)
  • Material Size
  • 1
  • Maximum Operating Temperature
  • 0 - 50°C
  • Maximum Transmembrane Pressure
  • Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
  • Media
  • Biomax®
  • Membrane Area
  • 0.5 m²
  • NMWL
  • 10 kDa
  • pH Range
  • pH1 – pH14
  • Recirculation Rate
  • 4 to 7 L/min/m²
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type C screen (coarse screen)
  • Trade Name
  • Pellicon®
  • Width
  • 17.8 cm (7.0 in.)
CTGB02TP3 Aerex CTGB Cartridge Filter 20 in. 0.2 µm Code 0 2092 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 0 (2-222) O-rings
  • Cartridge Nominal Length
  • 20 in. (50 cm)
  • Catalogue Number
  • CTGB02TP3
  • Chemistry
  • Polytetrafluoroethylene (PTFE)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Device Size
  • 20 in.
  • Diameter
  • 6.9 cm (2.7 in.)
  • Filtration Area
  • 1.3 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 35 mg per 10-inch cartridge after 24 hours in a 70/30% IPA/water mixture at controlled room temperature.
  • Length
  • 20 in. (50 cm)
  • Material Package
  • Easy-Open bag
  • Material Size
  • 3
  • Maximum Differential Pressure, bar (psid)
  • Forward: 6.9 bar (100 psid) @ 25 °C; 1.7 bar (25 psid) @ 80 °C; 0.35 bar (5 psid) @ 145 °C. Reverse: 5.2 bar (75 psid) @ 25 °C, intermittent
  • Maximum Inlet Pressure, bar (psi)
  • Forward - 7 bar (100 psi) @ 25 °C; 1.7 bar (25 psi) @ 80 °C; 0.35 bar (5 psi) @ 145 °C; Reverse - 5.2 bar (75 psi) @ 25 °C
  • Media
  • Aerex®
  • Non-Fiber Releasing
  • This product was manufactured with a PTFE membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Pore Size
  • 0.2 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 200 (150 forward/50 reverse) SIP cycles of 30 min @ 145 °C; SIP up to 165 hours in forward direction @ 145 °C
  • Support Material
  • Polypropylene
  • Trade Name
  • Aerex®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Wettability
  • Hydrophobic
CTGB02TP3 Aerex CTGB Cartridge Filter 20 in. 0.2 µm Code 0 2092 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 0 (2-222) O-rings
  • Cartridge Nominal Length
  • 20 in. (50 cm)
  • Catalogue Number
  • CTGB02TP3
  • Chemistry
  • Polytetrafluoroethylene (PTFE)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Device Size
  • 20 in.
  • Diameter
  • 6.9 cm (2.7 in.)
  • Filtration Area
  • 1.3 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 35 mg per 10-inch cartridge after 24 hours in a 70/30% IPA/water mixture at controlled room temperature.
  • Length
  • 20 in. (50 cm)
  • Material Package
  • Easy-Open bag
  • Material Size
  • 3
  • Maximum Differential Pressure, bar (psid)
  • Forward: 6.9 bar (100 psid) @ 25 °C; 1.7 bar (25 psid) @ 80 °C; 0.35 bar (5 psid) @ 145 °C. Reverse: 5.2 bar (75 psid) @ 25 °C, intermittent
  • Maximum Inlet Pressure, bar (psi)
  • Forward - 7 bar (100 psi) @ 25 °C; 1.7 bar (25 psi) @ 80 °C; 0.35 bar (5 psi) @ 145 °C; Reverse - 5.2 bar (75 psi) @ 25 °C
  • Media
  • Aerex®
  • Non-Fiber Releasing
  • This product was manufactured with a PTFE membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Pore Size
  • 0.2 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 200 (150 forward/50 reverse) SIP cycles of 30 min @ 145 °C; SIP up to 165 hours in forward direction @ 145 °C
  • Support Material
  • Polypropylene
  • Trade Name
  • Aerex®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Wettability
  • Hydrophobic
CTGB72TP3 Aerex CTGB Cartridge Filter 20 in. 0.2 µm Code 7 2092 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 7
  • Cartridge Nominal Length
  • 20 in. (50 cm)
  • Catalogue Number
  • CTGB72TP3
  • Chemistry
  • Polytetrafluoroethylene (PTFE)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Device Size
  • 20 in.
  • Diameter
  • 6.9 cm (2.7 in.)
  • Filtration Area
  • 1.3 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 35 mg per 10-inch cartridge after 24 hours in a 70/30% IPA/water mixture at controlled room temperature.
  • Length
  • 20 in. (50 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 3
  • Maximum Differential Pressure, bar (psid)
  • Forward: 6.9 bar (100 psid) @ 25 °C; 1.7 bar (25 psid) @ 80 °C; 0.35 bar (5 psid) @ 145 °C. Reverse: 5.2 bar (75 psid) @ 25 °C, intermittent
  • Maximum Inlet Pressure, bar (psi)
  • Forward - 7 bar (100 psi) @ 25 °C; 1.7 bar (25 psi) @ 80 °C; 0.35 bar (5 psi) @ 145 °C; Reverse - 5.2 bar (75 psi) @ 25 °C
  • Media
  • Aerex®
  • Non-Fiber Releasing
  • This product was manufactured with a PTFE membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Pore Size
  • 0.2 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 200 (150 forward/50 reverse) SIP cycles of 30 min @ 145 °C; SIP up to 165 hours in forward direction @ 145 °C
  • Support Material
  • Polypropylene
  • Trade Name
  • Aerex®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Wettability
  • Hydrophobic
CTGB72TP3 Aerex CTGB Cartridge Filter 20 in. 0.2 µm Code 7 2092 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 7
  • Cartridge Nominal Length
  • 20 in. (50 cm)
  • Catalogue Number
  • CTGB72TP3
  • Chemistry
  • Polytetrafluoroethylene (PTFE)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Device Size
  • 20 in.
  • Diameter
  • 6.9 cm (2.7 in.)
  • Filtration Area
  • 1.3 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 35 mg per 10-inch cartridge after 24 hours in a 70/30% IPA/water mixture at controlled room temperature.
  • Length
  • 20 in. (50 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 3
  • Maximum Differential Pressure, bar (psid)
  • Forward: 6.9 bar (100 psid) @ 25 °C; 1.7 bar (25 psid) @ 80 °C; 0.35 bar (5 psid) @ 145 °C. Reverse: 5.2 bar (75 psid) @ 25 °C, intermittent
  • Maximum Inlet Pressure, bar (psi)
  • Forward - 7 bar (100 psi) @ 25 °C; 1.7 bar (25 psi) @ 80 °C; 0.35 bar (5 psi) @ 145 °C; Reverse - 5.2 bar (75 psi) @ 25 °C
  • Media
  • Aerex®
  • Non-Fiber Releasing
  • This product was manufactured with a PTFE membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Pore Size
  • 0.2 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 200 (150 forward/50 reverse) SIP cycles of 30 min @ 145 °C; SIP up to 165 hours in forward direction @ 145 °C
  • Support Material
  • Polypropylene
  • Trade Name
  • Aerex®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Wettability
  • Hydrophobic
P2B01MV05 Pellicon® 2 Cassette with Biomax® 1000 kDa Membrane, V screen, 0.5 m² 2108 
Add to Cart
  • Catalogue Number
  • P2B01MV05
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene and Polysulfone end cap
  • Filter Code
  • Biomax 1000
  • Filter Type
  • Ultrafiltration
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Height
  • 2.16 cm (0.85 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 20.6 cm (8.1 in)
  • Material Size
  • 1
  • Maximum Operating Temperature
  • 0 - 50°C
  • Maximum Transmembrane Pressure
  • Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
  • Media
  • Biomax®
  • Membrane Area
  • 0.5 m²
  • NMWL
  • 1000 kDa
  • pH Range
  • pH1 – pH14
  • Recirculation Rate
  • 7 to 10 L/min/m²
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type V screen (open channel)
  • Trade Name
  • Pellicon®
  • Width
  • 17.8 cm (7.0 in.)
P2B01MV05 Pellicon® 2 Cassette with Biomax® 1000 kDa Membrane, V screen, 0.5 m² 2108 
Add to Cart
  • Catalogue Number
  • P2B01MV05
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene and Polysulfone end cap
  • Filter Code
  • Biomax 1000
  • Filter Type
  • Ultrafiltration
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Height
  • 2.16 cm (0.85 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 20.6 cm (8.1 in)
  • Material Size
  • 1
  • Maximum Operating Temperature
  • 0 - 50°C
  • Maximum Transmembrane Pressure
  • Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
  • Media
  • Biomax®
  • Membrane Area
  • 0.5 m²
  • NMWL
  • 1000 kDa
  • pH Range
  • pH1 – pH14
  • Recirculation Rate
  • 7 to 10 L/min/m²
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type V screen (open channel)
  • Trade Name
  • Pellicon®
  • Width
  • 17.8 cm (7.0 in.)
P2B300C05 Pellicon® 2 Cassette with Biomax® 300 kDa Membrane, C screen, 0.5 m² 2108 
Add to Cart
  • Catalogue Number
  • P2B300C05
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • Biomax 300
  • Filter Type
  • Ultrafiltration
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Height
  • 1.5 cm (0.6 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 20.6 cm (8.1 in)
  • Material Size
  • 1
  • Maximum Operating Temperature
  • 0 - 50°C
  • Maximum Transmembrane Pressure
  • Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
  • Media
  • Biomax®
  • Membrane Area
  • 0.5 m²
  • NMWL
  • 300 kDa
  • pH Range
  • pH1 – pH14
  • Recirculation Rate
  • 4 to 7 L/min/m²
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type C screen (coarse screen)
  • Trade Name
  • Pellicon®
  • Width
  • 17.8 cm (7.0 in.)
P2B300C05 Pellicon® 2 Cassette with Biomax® 300 kDa Membrane, C screen, 0.5 m² 2108 
Add to Cart
  • Catalogue Number
  • P2B300C05
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • Biomax 300
  • Filter Type
  • Ultrafiltration
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Height
  • 1.5 cm (0.6 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 20.6 cm (8.1 in)
  • Material Size
  • 1
  • Maximum Operating Temperature
  • 0 - 50°C
  • Maximum Transmembrane Pressure
  • Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
  • Media
  • Biomax®
  • Membrane Area
  • 0.5 m²
  • NMWL
  • 300 kDa
  • pH Range
  • pH1 – pH14
  • Recirculation Rate
  • 4 to 7 L/min/m²
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type C screen (coarse screen)
  • Trade Name
  • Pellicon®
  • Width
  • 17.8 cm (7.0 in.)
P2B500C05 Pellicon® 2 Cassette with Biomax® 500 kDa Membrane, C screen, 0.5 m² 2108 
Add to Cart
  • Catalogue Number
  • P2B500C05
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • Biomax 500
  • Filter Type
  • Ultrafiltration
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Height
  • 1.5 cm (0.6 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 20.6 cm (8.1 in)
  • Material Size
  • 1
  • Maximum Operating Temperature
  • 0 - 50°C
  • Maximum Transmembrane Pressure
  • Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
  • Media
  • Biomax®
  • Membrane Area
  • 0.5 m²
  • NMWL
  • 500 kDa
  • pH Range
  • pH1 – pH14
  • Recirculation Rate
  • 4 to 7 L/min/m²
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type C screen (coarse screen)
  • Trade Name
  • Pellicon®
  • Width
  • 17.8 cm (7.0 in.)

Overview

Analytical Sample Preparation Membrane Filtration Devices


Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.


Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.


Filter Membranes

Millex® Syringe Filters

Filtration Holders & Accessories



Resources