+852-3069 6950
css@gugent.com.hk
 

We have developed a unique portfolio of consumables, each adapted to the different feed water quality requirements and to your various applications. To maintain your water system’s performance, it’s critical to replace your purification cartridges on time and with genuine ISO 9001-certified parts.

Catalog No. Product Net Price
P2B008A05 Pellicon® 2 Cassette with Biomax® 8 kDa Membrane, A screen, 0.5 m² 2147 
Add to Cart
  • Catalogue Number
  • P2B008A05
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • Biomax 8
  • Filter Type
  • Ultrafiltration
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Height
  • 1.5 cm (0.6 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 20.6 cm (8.1 in)
  • Material Size
  • 1
  • Maximum Operating Temperature
  • 0 - 50°C
  • Maximum Transmembrane Pressure
  • Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
  • Media
  • Biomax®
  • Membrane Area
  • 0.5 m²
  • NMWL
  • 8 kDa
  • pH Range
  • pH1 – pH14
  • Recirculation Rate
  • 4 to 7 L/min/m²
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type A screen (tight screen)
  • Trade Name
  • Pellicon®
  • Width
  • 17.8 cm (7.0 in.)
P2B008V05 Pellicon® 2 Cassette with Biomax® 8 kDa Membrane, V screen, 0.5 m² 2147 
Add to Cart
  • Catalogue Number
  • P2B008V05
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene and Polysulfone end cap
  • Filter Code
  • Biomax 8
  • Filter Type
  • Ultrafiltration
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Height
  • 2.16 cm (0.85 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 20.6 cm (8.1 in)
  • Material Size
  • 1
  • Maximum Operating Temperature
  • 0 - 50°C
  • Maximum Transmembrane Pressure
  • Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
  • Media
  • Biomax®
  • Membrane Area
  • 0.5 m²
  • NMWL
  • 8 kDa
  • pH Range
  • pH1 – pH14
  • Recirculation Rate
  • 7 to 10 L/min/m²
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type V screen (open channel)
  • Trade Name
  • Pellicon®
  • Width
  • 17.8 cm (7.0 in.)
P2B008V05 Pellicon® 2 Cassette with Biomax® 8 kDa Membrane, V screen, 0.5 m² 2147 
Add to Cart
  • Catalogue Number
  • P2B008V05
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene and Polysulfone end cap
  • Filter Code
  • Biomax 8
  • Filter Type
  • Ultrafiltration
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Height
  • 2.16 cm (0.85 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 20.6 cm (8.1 in)
  • Material Size
  • 1
  • Maximum Operating Temperature
  • 0 - 50°C
  • Maximum Transmembrane Pressure
  • Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
  • Media
  • Biomax®
  • Membrane Area
  • 0.5 m²
  • NMWL
  • 8 kDa
  • pH Range
  • pH1 – pH14
  • Recirculation Rate
  • 7 to 10 L/min/m²
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type V screen (open channel)
  • Trade Name
  • Pellicon®
  • Width
  • 17.8 cm (7.0 in.)
P2C005V05 Pellicon® 2 Cassette with Ultracel® 5 kDa Membrane, V screen, 0.5 m² 2147 
Add to Cart
  • Catalogue Number
  • P2C005V05
  • Chemistry
  • Composite Regenerated Cellulose (CRC)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene and Polysulfone end cap
  • Filter Code
  • PLCCC
  • Filter Type
  • Ultrafiltration
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Height
  • 2.16 cm (0.85 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 20.6 cm (8.1 in)
  • Material Size
  • 1
  • Maximum Operating Temperature
  • 0 - 30°C
  • Maximum Transmembrane Pressure
  • Forward: 3.4 bar (50 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
  • Media
  • Ultracel®
  • Membrane Area
  • 0.5 m²
  • NMWL
  • 5 kDa
  • pH Range
  • pH2 – pH13
  • Recirculation Rate
  • 7 to 10 L/min/m²
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type V screen (open channel)
  • Trade Name
  • Pellicon®
  • Width
  • 17.8 cm (7.0 in.)
P2C005V05 Pellicon® 2 Cassette with Ultracel® 5 kDa Membrane, V screen, 0.5 m² 2147 
Add to Cart
  • Catalogue Number
  • P2C005V05
  • Chemistry
  • Composite Regenerated Cellulose (CRC)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene and Polysulfone end cap
  • Filter Code
  • PLCCC
  • Filter Type
  • Ultrafiltration
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Height
  • 2.16 cm (0.85 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 20.6 cm (8.1 in)
  • Material Size
  • 1
  • Maximum Operating Temperature
  • 0 - 30°C
  • Maximum Transmembrane Pressure
  • Forward: 3.4 bar (50 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
  • Media
  • Ultracel®
  • Membrane Area
  • 0.5 m²
  • NMWL
  • 5 kDa
  • pH Range
  • pH2 – pH13
  • Recirculation Rate
  • 7 to 10 L/min/m²
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type V screen (open channel)
  • Trade Name
  • Pellicon®
  • Width
  • 17.8 cm (7.0 in.)
P2PLBCV05 Pellicon 2 Cassette Ultrafiltration Module PLBC V 0.5 m2 2147 
Add to Cart
  • Catalogue Number
  • P2PLBCV05
  • Chemistry
  • Regenerated Cellulose (RC)
  • Device Configuration
  • Cassette
  • Device Size
  • 0.5 m²
  • Filter Code
  • PLBC
  • Filter Type
  • Ultrafiltration
  • Filtration Area
  • 0.5 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Height
  • 2.16 cm (0.85 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 21 cm (8.3 in.)
  • Material Size
  • 1
  • Maximum Transmembrane Pressure
  • 3.5 bar (50 psig) @ 30 °C
  • Media
  • Ultracel®
  • Membrane Area
  • 0.5 m²
  • NMWL
  • 3 kDa
  • Recirculation Rate
  • 5–35 L/min @ 0.4 bar (6 psi)
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type V screen (open channel)
  • Trade Name
  • Pellicon®
  • Width
  • 17.8 cm (7.0 in.)
P2B050V05 Pellicon® 2 Cassette with Biomax® 50 kDa Membrane, V screen, 0.5 m² 2153 
Add to Cart
  • Catalogue Number
  • P2B050V05
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene and Polysulfone end cap
  • Filter Code
  • Biomax 50
  • Filter Type
  • Ultrafiltration
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Height
  • 2.16 cm (0.85 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 20.6 cm (8.1 in)
  • Material Size
  • 1
  • Maximum Operating Temperature
  • 0 - 50°C
  • Maximum Transmembrane Pressure
  • Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
  • Media
  • Biomax®
  • Membrane Area
  • 0.5 m²
  • NMWL
  • 50 kDa
  • pH Range
  • pH1 – pH14
  • Recirculation Rate
  • 7 to 10 L/min/m²
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type V screen (open channel)
  • Trade Name
  • Pellicon®
  • Width
  • 17.8 cm (7.0 in.)
P2B050V05 Pellicon® 2 Cassette with Biomax® 50 kDa Membrane, V screen, 0.5 m² 2153 
Add to Cart
  • Catalogue Number
  • P2B050V05
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene and Polysulfone end cap
  • Filter Code
  • Biomax 50
  • Filter Type
  • Ultrafiltration
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Height
  • 2.16 cm (0.85 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 20.6 cm (8.1 in)
  • Material Size
  • 1
  • Maximum Operating Temperature
  • 0 - 50°C
  • Maximum Transmembrane Pressure
  • Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
  • Media
  • Biomax®
  • Membrane Area
  • 0.5 m²
  • NMWL
  • 50 kDa
  • pH Range
  • pH1 – pH14
  • Recirculation Rate
  • 7 to 10 L/min/m²
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type V screen (open channel)
  • Trade Name
  • Pellicon®
  • Width
  • 17.8 cm (7.0 in.)
P2B010V05 Pellicon® 2 Cassette with Biomax® 10 kDa Membrane, V screen, 0.5 m² 2161 
Add to Cart
  • Catalogue Number
  • P2B010V05
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene and Polysulfone end cap
  • Filter Code
  • Biomax 10
  • Filter Type
  • Ultrafiltration
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Height
  • 2.16 cm (0.85 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 20.6 cm (8.1 in)
  • Material Size
  • 1
  • Maximum Operating Temperature
  • 0 - 50°C
  • Maximum Transmembrane Pressure
  • Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
  • Media
  • Biomax®
  • Membrane Area
  • 0.5 m²
  • NMWL
  • 10 kDa
  • pH Range
  • pH1 – pH14
  • Recirculation Rate
  • 7 to 10 L/min/m²
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type V screen (open channel)
  • Trade Name
  • Pellicon®
  • Width
  • 17.8 cm (7.0 in.)
P2B010V05 Pellicon® 2 Cassette with Biomax® 10 kDa Membrane, V screen, 0.5 m² 2161 
Add to Cart
  • Catalogue Number
  • P2B010V05
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene and Polysulfone end cap
  • Filter Code
  • Biomax 10
  • Filter Type
  • Ultrafiltration
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Height
  • 2.16 cm (0.85 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 20.6 cm (8.1 in)
  • Material Size
  • 1
  • Maximum Operating Temperature
  • 0 - 50°C
  • Maximum Transmembrane Pressure
  • Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
  • Media
  • Biomax®
  • Membrane Area
  • 0.5 m²
  • NMWL
  • 10 kDa
  • pH Range
  • pH1 – pH14
  • Recirculation Rate
  • 7 to 10 L/min/m²
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type V screen (open channel)
  • Trade Name
  • Pellicon®
  • Width
  • 17.8 cm (7.0 in.)

Overview

Analytical Sample Preparation Membrane Filtration Devices


Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.


Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.


Filter Membranes

Millex® Syringe Filters

Filtration Holders & Accessories



Resources