About 30 years ago MACHEREY‑NAGEL designed and introduced CHROMABOND SPE cartridges containing silica-based adsorbents.

SPE is a form of digital (step-wise) chromatography designed to extract, partition, and / or adsorb one or more components from a liquid phase (sample) onto a stationary phase (adsorbent or resin). An adsorbed substance can be removed from the adsorbent by stepwise increase of elution strength of the eluent (step gradient technique).

SPE extends a chromatographic system’s lifetime, improves qualitative and quantitative analysis, and the demand placed on an analytical instrument is considerably lessened.


Catalog No. Product Net Price
MN732812 CHROMABOND Flash RS 25 C18 ec cartridges, 40–63 µm, 26 g Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Flash chromatography
  • Brand
  • CHROMABOND
  • Phase
  • C18 ec
  • Mode
  • Reversed phase (RP)
  • Base material
  • Silica gel
  • Surface chemistry
  • Octadecyl (ODS, C18 ec, RP18 ec) modified silica phase, endcapped
  • Endcapped
  • Hardware
  • Column type
  • Flash RS
  • Column length
  • 17.3 cm
  • Column inner diameter
  • 21.2 mm
  • Column connection
  • Female Luer lock inlet and male Luer tip outlet
  • Filling material
  • Irregular, 40–63 µm
  • Hardware
  • Polypropylene (PP)
  • Filling quantity
  • 26 g
  • Recommended application(s)
  • Reversed phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 40–63 µm
  • Pore size
  • 60 Å
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • Removable closure
  • Non-removable
  • Typical flow rate
  • 25–55 mL/min
  • pH stability
  • 2.0–8.0
  • Pressure stability (max)
  • 21 bar
  • Filter element material
  • Polyethylene (PE)
  • Scope of delivery
  • 1x CHROMABOND Flash RS cartridge
  • Storage temperature
  • RT
MN732813 CHROMABOND Flash RS 40 C18 ec cartridges, 40–63 µm, 43 g Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Flash chromatography
  • Brand
  • CHROMABOND
  • Phase
  • C18 ec
  • Mode
  • Reversed phase (RP)
  • Base material
  • Silica gel
  • Surface chemistry
  • Octadecyl (ODS, C18 ec, RP18 ec) modified silica phase, endcapped
  • Endcapped
  • Hardware
  • Column type
  • Flash RS
  • Column length
  • 17.6 cm
  • Column inner diameter
  • 26.7 mm
  • Column connection
  • Female Luer lock inlet and male Luer tip outlet
  • Filling material
  • Irregular, 40–63 µm
  • Hardware
  • Polypropylene (PP)
  • Filling quantity
  • 43 g
  • Recommended application(s)
  • Reversed phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 40–63 µm
  • Pore size
  • 60 Å
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • Removable closure
  • Non-removable
  • Typical flow rate
  • 35–65 mL/min
  • pH stability
  • 2.0–8.0
  • Pressure stability (max)
  • 21 bar
  • Filter element material
  • Polyethylene (PE)
  • Scope of delivery
  • 1x CHROMABOND Flash RS cartridge
  • Storage temperature
  • RT
MN732814 CHROMABOND Flash RS 80 C18 ec cartridges, 40–63 µm, 86 g Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Flash chromatography
  • Brand
  • CHROMABOND
  • Phase
  • C18 ec
  • Mode
  • Reversed phase (RP)
  • Base material
  • Silica gel
  • Surface chemistry
  • Octadecyl (ODS, C18 ec, RP18 ec) modified silica phase, endcapped
  • Endcapped
  • Hardware
  • Column type
  • Flash RS
  • Column length
  • 24.9 cm
  • Column inner diameter
  • 30.9 mm
  • Column connection
  • Female Luer lock inlet and male Luer tip outlet
  • Filling material
  • Irregular, 40–63 µm
  • Hardware
  • Polypropylene (PP)
  • Filling quantity
  • 86 g
  • Recommended application(s)
  • Reversed phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 40–63 µm
  • Pore size
  • 60 Å
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • Removable closure
  • Non-removable
  • Typical flow rate
  • 45–95 mL/min
  • pH stability
  • 2.0–8.0
  • Pressure stability (max)
  • 14 bar
  • Filter element material
  • Polyethylene (PE)
  • Scope of delivery
  • 1x CHROMABOND Flash RS cartridge
  • Storage temperature
  • RT
MN732815 CHROMABOND Flash RS 120 C18 ec cartridges, 40–63 µm, 130 g Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Flash chromatography
  • Brand
  • CHROMABOND
  • Phase
  • C18 ec
  • Mode
  • Reversed phase (RP)
  • Base material
  • Silica gel
  • Surface chemistry
  • Octadecyl (ODS, C18 ec, RP18 ec) modified silica phase, endcapped
  • Endcapped
  • Hardware
  • Column type
  • Flash RS
  • Column length
  • 26.2 cm
  • Column inner diameter
  • 37.2 mm
  • Column connection
  • Female Luer lock inlet and male Luer tip outlet
  • Filling material
  • Irregular, 40–63 µm
  • Hardware
  • Polypropylene (PP)
  • Filling quantity
  • 130 g
  • Recommended application(s)
  • Reversed phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 40–63 µm
  • Pore size
  • 60 Å
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • Removable closure
  • Non-removable
  • Typical flow rate
  • 55–140 mL/min
  • pH stability
  • 2.0–8.0
  • Pressure stability (max)
  • 14 bar
  • Filter element material
  • Polyethylene (PE)
  • Scope of delivery
  • 1x CHROMABOND Flash RS cartridge
  • Storage temperature
  • RT
MN732816 CHROMABOND Flash RS 200 C18 ec cartridges, 40–63 µm, 220 g Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Flash chromatography
  • Brand
  • CHROMABOND
  • Phase
  • C18 ec
  • Mode
  • Reversed phase (RP)
  • Base material
  • Silica gel
  • Surface chemistry
  • Octadecyl (ODS, C18 ec, RP18 ec) modified silica phase, endcapped
  • Endcapped
  • Hardware
  • Column type
  • Flash RS
  • Column length
  • 21.6 cm
  • Column inner diameter
  • 59.4 mm
  • Column connection
  • Female Luer lock inlet and male Luer tip outlet
  • Filling material
  • Irregular, 40–63 µm
  • Hardware
  • Polypropylene (PP)
  • Filling quantity
  • 220 g
  • Recommended application(s)
  • Reversed phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 40–63 µm
  • Pore size
  • 60 Å
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • Removable closure
  • Non-removable
  • Typical flow rate
  • 75–210 mL/min
  • pH stability
  • 2.0–8.0
  • Pressure stability (max)
  • 11 bar
  • Filter element material
  • Polyethylene (PE)
  • Scope of delivery
  • 1x CHROMABOND Flash RS cartridge
  • Storage temperature
  • RT
MN732817 CHROMABOND Flash RS 330 C18 ec cartridges, 40–63 µm, 360 g Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Flash chromatography
  • Brand
  • CHROMABOND
  • Phase
  • C18 ec
  • Mode
  • Reversed phase (RP)
  • Base material
  • Silica gel
  • Surface chemistry
  • Octadecyl (ODS, C18 ec, RP18 ec) modified silica phase, endcapped
  • Endcapped
  • Hardware
  • Column type
  • Flash RS
  • Column length
  • 28.0 cm
  • Column inner diameter
  • 59.8 mm
  • Column connection
  • Female Luer lock inlet and male Luer tip outlet
  • Filling material
  • Irregular, 40–63 µm
  • Hardware
  • Polypropylene (PP)
  • Filling quantity
  • 360 g
  • Recommended application(s)
  • Reversed phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 40–63 µm
  • Pore size
  • 60 Å
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • Removable closure
  • Non-removable
  • Typical flow rate
  • 75–210 mL/min
  • pH stability
  • 2.0–8.0
  • Pressure stability (max)
  • 11 bar
  • Filter element material
  • Polyethylene (PE)
  • Scope of delivery
  • 1x CHROMABOND Flash RS cartridge
  • Storage temperature
  • RT
MN732718 CHROMABOND Flash RS 800 C18 ec cartridges, 15–40 µm, 880 g Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Flash chromatography
  • Brand
  • CHROMABOND
  • Phase
  • C18 ec
  • Mode
  • Reversed phase (RP)
  • Base material
  • Silica gel
  • Surface chemistry
  • Octadecyl (ODS, C18 ec, RP18 ec) modified silica phase, endcapped
  • Endcapped
  • Hardware
  • Column type
  • Flash RS
  • Column length
  • 38.3 cm
  • Column inner diameter
  • 78.2 mm
  • Column connection
  • Maxi Luer
  • Filling material
  • Irregular, 15–40 µm
  • Hardware
  • Polypropylene (PP)
  • Filling quantity
  • 880 g
  • Recommended application(s)
  • Reversed phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 15–40 µm
  • Pore size
  • 60 Å
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • Removable closure
  • Non-removable
  • Typical flow rate
  • 100–300 mL/min
  • pH stability
  • 2.0–8.0
  • Pressure stability (max)
  • 7 bar
  • Filter element material
  • Polyethylene (PE)
  • Scope of delivery
  • 1x CHROMABOND Flash RS cartridge
  • Storage temperature
  • RT
MN732719 CHROMABOND Flash RS 1600 C18 ec cartridges,15–40 µm, 1760 g Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Flash chromatography
  • Brand
  • CHROMABOND
  • Phase
  • C18 ec
  • Mode
  • Reversed phase (RP)
  • Base material
  • Silica gel
  • Surface chemistry
  • Octadecyl (ODS, C18 ec, RP18 ec) modified silica phase, endcapped
  • Endcapped
  • Hardware
  • Column type
  • Flash RS
  • Column length
  • 43.2 cm
  • Column inner diameter
  • 103.8 mm
  • Column connection
  • Maxi Luer
  • Filling material
  • Irregular, 15–40 µm
  • Hardware
  • Polypropylene (PP)
  • Filling quantity
  • 1760 g
  • Recommended application(s)
  • Reversed phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 15–40 µm
  • Pore size
  • 60 Å
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • Removable closure
  • Non-removable
  • Typical flow rate
  • 200–500 mL/min
  • pH stability
  • 2.0–8.0
  • Pressure stability (max)
  • 7 bar
  • Filter element material
  • Polyethylene (PE)
  • Scope of delivery
  • 1x CHROMABOND Flash RS cartridge
  • Storage temperature
  • RT
MN732818 CHROMABOND Flash RS 800 C18 ec cartridges, 40–63 µm, 880 g Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Flash chromatography
  • Brand
  • CHROMABOND
  • Phase
  • C18 ec
  • Mode
  • Reversed phase (RP)
  • Base material
  • Silica gel
  • Surface chemistry
  • Octadecyl (ODS, C18 ec, RP18 ec) modified silica phase, endcapped
  • Endcapped
  • Hardware
  • Column type
  • Flash RS
  • Column length
  • 38.3 cm
  • Column inner diameter
  • 78.2 mm
  • Column connection
  • Maxi Luer
  • Filling material
  • Irregular, 40–63 µm
  • Hardware
  • Polypropylene (PP)
  • Filling quantity
  • 880 g
  • Recommended application(s)
  • Reversed phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 40–63 µm
  • Pore size
  • 60 Å
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • Removable closure
  • Non-removable
  • Typical flow rate
  • 140–240 mL/min
  • pH stability
  • 2.0–8.0
  • Pressure stability (max)
  • 7 bar
  • Filter element material
  • Polyethylene (PE)
  • Scope of delivery
  • 1x CHROMABOND Flash RS cartridge
  • Storage temperature
  • RT
MN732819 CHROMABOND Flash RS 1600 C18 ec cartridges, 40–63 µm, 1760 g Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Flash chromatography
  • Brand
  • CHROMABOND
  • Phase
  • C18 ec
  • Mode
  • Reversed phase (RP)
  • Base material
  • Silica gel
  • Surface chemistry
  • Octadecyl (ODS, C18 ec, RP18 ec) modified silica phase, endcapped
  • Endcapped
  • Hardware
  • Column type
  • Flash RS
  • Column length
  • 43.2 cm
  • Column inner diameter
  • 103.8 mm
  • Column connection
  • Maxi Luer
  • Filling material
  • Irregular, 40–63 µm
  • Hardware
  • Polypropylene (PP)
  • Filling quantity
  • 1760 g
  • Recommended application(s)
  • Reversed phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 40–63 µm
  • Pore size
  • 60 Å
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • Removable closure
  • Non-removable
  • Typical flow rate
  • 190–250 mL/min
  • pH stability
  • 2.0–8.0
  • Pressure stability (max)
  • 7 bar
  • Filter element material
  • Polyethylene (PE)
  • Scope of delivery
  • 1x CHROMABOND Flash RS cartridge
  • Storage temperature
  • RT

Overview

Main steps of the SPE procedure

1) Conditioning

Conditioning of the adsorbent is necessary in order to ensure reproducible interaction with the analyte. Conditioning, also called solvation, results in a wetting of the adsorbent and thus produces an environment, which is suitable for adsorption of the analyte. Nonpolar adsorbents are usually conditioned with 2–3 column volumes of a solvent, which is miscible with water (methanol, THF, 2-propanol etc.), followed by the solvent in which the analyte is dissolved (pure matrix, e.g., water, buffer). Polar adsorbents are conditioned with nonpolar solvents. After the conditioning step the adsorbent bed must not run dry, because otherwise solvation is destroyed (deconditioning).


2) Sample application (adsorption)

Sample application can be performed with positive or negative pressure with a flow rate of ~3 mL/min. Sample volumes vary from a few mL up to liters.


3) Washing

Washing of the adsorbent is usually achieved with a special wash solution; however, in some cases it may not be necessary. If the polarity difference between wash solution and eluent is very large, or if both are not miscible, drying of the adsorbent bed after washing is recommended to improve elution and recovery.


4) Elution

Elution with a suitable eluent should not be too fast. The elution speed depends on the column or cartridge dimension and the quantity of adsorbent (about 1 mL/min).


Since analytes can either be adsorbed on the SPE packing material or directly flown through while the interfering substances are retained, two general separation procedures are possible – both cases are shown in the figure below.



Resources