MN711992.10
LC packing material (adsorbents, bulk), silica gel, POLYGOSIL 1000-7 C18
Special offer
Add to Cart
Hazardous material
No
Method
LC, packing material (adsorbent, bulk)
Brand
POLYGOSIL
Phase
POLYGOSIL 1000-7 C18
Mode
Normal phase (NP)
Base material
Silica gel
Surface chemistry
Octadecyl (C18, ODS) modification, Octadecyl phase (C18, ODS) modification
Endcapped
Yes
Selling unit
10 g, 100 g
Recommended application(s)
LC packing material for analytical applications
Particle type
Fully porous particles (FPP)
Particle size
7 µm
Pore size
1000 Å
Particle shape
Irregular
pH stability
2.0–8.0
Storage temperature
RT
MN732712
CHROMABOND Flash RS 25 C18 ec cartridges, 15–40 µm, 26 g
Special offer
Add to Cart
Hazardous material
No
Method
Flash chromatography
Brand
CHROMABOND
Phase
C18 ec
Mode
Reversed phase (RP)
Base material
Silica gel
Surface chemistry
Octadecyl (ODS, C18 ec, RP18 ec) modified silica phase, endcapped
Endcapped
Hardware
Column type
Flash RS
Column length
17.3 cm
Column inner diameter
21.2 mm
Column connection
Female Luer lock inlet and male Luer tip outlet
Filling material
Irregular, 15–40 µm
Hardware
Polypropylene (PP)
Filling quantity
26 g
Recommended application(s)
Reversed phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
Particle type
Fully porous particles (FPP)
Particle size
15–40 µm
Pore size
60 Å
Particle shape
Irregular
Specific surface according to BET
500 m²/g
Removable closure
Non-removable
Typical flow rate
25–70 mL/min
pH stability
2.0–8.0
Pressure stability (max)
21 bar
Filter element material
Polyethylene (PE)
Scope of delivery
1x CHROMABOND Flash RS cartridge
Storage temperature
RT
MN732713
CHROMABOND Flash RS 40 C18 ec cartridges, 15–40 µm, 43 g
Special offer
Add to Cart
Hazardous material
No
Method
Flash chromatography
Brand
CHROMABOND
Phase
C18 ec
Mode
Reversed phase (RP)
Base material
Silica gel
Surface chemistry
Octadecyl (ODS, C18 ec, RP18 ec) modified silica phase, endcapped
Endcapped
Hardware
Column type
Flash RS
Column length
17.6 cm
Column inner diameter
26.7 mm
Column connection
Female Luer lock inlet and male Luer tip outlet
Filling material
Irregular, 15–40 µm
Hardware
Polypropylene (PP)
Filling quantity
43 g
Recommended application(s)
Reversed phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
Particle type
Fully porous particles (FPP)
Particle size
15–40 µm
Pore size
60 Å
Particle shape
Irregular
Specific surface according to BET
500 m²/g
Removable closure
Non-removable
Typical flow rate
35–80 mL/min
pH stability
2.0–8.0
Pressure stability (max)
21 bar
Filter element material
Polyethylene (PE)
Scope of delivery
1x CHROMABOND Flash RS cartridge
Storage temperature
RT
MN732714
CHROMABOND Flash RS 80 C18 ec cartridges, 15–40 µm, 86 g
Special offer
Add to Cart
Hazardous material
No
Method
Flash chromatography
Brand
CHROMABOND
Phase
C18 ec
Mode
Reversed phase (RP)
Base material
Silica gel
Surface chemistry
Octadecyl (ODS, C18 ec, RP18 ec) modified silica phase, endcapped
Endcapped
Hardware
Column type
Flash RS
Column length
24.9 cm
Column inner diameter
30.9 mm
Column connection
Female Luer lock inlet and male Luer tip outlet
Filling material
Irregular, 15–40 µm
Hardware
Polypropylene (PP)
Filling quantity
86 g
Recommended application(s)
Reversed phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
Particle type
Fully porous particles (FPP)
Particle size
15–40 µm
Pore size
60 Å
Particle shape
Irregular
Specific surface according to BET
500 m²/g
Removable closure
Non-removable
Typical flow rate
45–105 mL/min
pH stability
2.0–8.0
Pressure stability (max)
14 bar
Filter element material
Polyethylene (PE)
Scope of delivery
1x CHROMABOND Flash RS cartridge
Storage temperature
RT
MN732715
CHROMABOND Flash RS 120 C18 ec cartridges, 15–40 µm, 130 g
Special offer
Add to Cart
Hazardous material
No
Method
Flash chromatography
Brand
CHROMABOND
Phase
C18 ec
Mode
Reversed phase (RP)
Base material
Silica gel
Surface chemistry
Octadecyl (ODS, C18 ec, RP18 ec) modified silica phase, endcapped
Endcapped
Hardware
Column type
Flash RS
Column length
26.2 cm
Column inner diameter
37.2 mm
Column connection
Female Luer lock inlet and male Luer tip outlet
Filling material
Irregular, 15–40 µm
Hardware
Polypropylene (PP)
Filling quantity
130 g
Recommended application(s)
Reversed phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
Particle type
Fully porous particles (FPP)
Particle size
15–40 µm
Pore size
60 Å
Particle shape
Irregular
Specific surface according to BET
500 m²/g
Removable closure
Non-removable
Typical flow rate
55–155 mL/min
pH stability
2.0–8.0
Pressure stability (max)
14 bar
Filter element material
Polyethylene (PE)
Scope of delivery
1x CHROMABOND Flash RS cartridge
Storage temperature
RT
MN732716
CHROMABOND Flash RS 200 C18 ec cartridges, 15–40 µm, 220 g
Special offer
Add to Cart
Hazardous material
No
Method
Flash chromatography
Brand
CHROMABOND
Phase
C18 ec
Mode
Reversed phase (RP)
Base material
Silica gel
Surface chemistry
Octadecyl (ODS, C18 ec, RP18 ec) modified silica phase, endcapped
Endcapped
Hardware
Column type
Flash RS
Column length
21.6 cm
Column inner diameter
59.4 mm
Column connection
Female Luer lock inlet and male Luer tip outlet
Filling material
Irregular, 15–40 µm
Hardware
Polypropylene (PP)
Filling quantity
220 g
Recommended application(s)
Reversed phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
Particle type
Fully porous particles (FPP)
Particle size
15–40 µm
Pore size
60 Å
Particle shape
Irregular
Specific surface according to BET
500 m²/g
Removable closure
Non-removable
Typical flow rate
75–255 mL/min
pH stability
2.0–8.0
Pressure stability (max)
11 bar
Filter element material
Polyethylene (PE)
Scope of delivery
1x CHROMABOND Flash RS cartridge
Storage temperature
RT
MN732717
CHROMABOND Flash RS 330 C18 ec cartridges, 15–40 µm, 360 g
Special offer
Add to Cart
Hazardous material
No
Method
Flash chromatography
Brand
CHROMABOND
Phase
C18 ec
Mode
Reversed phase (RP)
Base material
Silica gel
Surface chemistry
Octadecyl (ODS, C18 ec, RP18 ec) modified silica phase, endcapped
Endcapped
Hardware
Column type
Flash RS
Column length
28.0 cm
Column inner diameter
59.8 mm
Column connection
Female Luer lock inlet and male Luer tip outlet
Filling material
Irregular, 15–40 µm
Hardware
Polypropylene (PP)
Filling quantity
360 g
Recommended application(s)
Reversed phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
Particle type
Fully porous particles (FPP)
Particle size
15–40 µm
Pore size
60 Å
Particle shape
Irregular
Specific surface according to BET
500 m²/g
Removable closure
Non-removable
Typical flow rate
75–255 mL/min
pH stability
2.0–8.0
Pressure stability (max)
11 bar
Filter element material
Polyethylene (PE)
Scope of delivery
1x CHROMABOND Flash RS cartridge
Storage temperature
RT
MN732720
CHROMABOND Flash RS 4 C18 ec cartridges, 15–40 µm, 4.3 g
Special offer
Add to Cart
Hazardous material
No
Method
Flash chromatography
Brand
CHROMABOND
Phase
C18 ec
Mode
Reversed phase (RP)
Base material
Silica gel
Surface chemistry
Octadecyl (ODS, C18 ec, RP18 ec) modified silica phase, endcapped
Endcapped
Hardware
Column type
Flash RS
Column length
10.6 cm
Column inner diameter
12.4 mm
Column connection
Female Luer lock inlet and male Luer tip outlet
Filling material
Irregular, 15–40 µm
Hardware
Polypropylene (PP)
Filling quantity
5 g
Recommended application(s)
Reversed phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
Particle type
Fully porous particles (FPP)
Particle size
15–40 µm
Pore size
60 Å
Particle shape
Irregular
Specific surface according to BET
500 m²/g
Removable closure
Non-removable
Typical flow rate
10–25 mL/min
pH stability
2.0–8.0
Pressure stability (max)
21 bar
Filter element material
Polyethylene (PE)
Scope of delivery
2x CHROMABOND Flash RS cartridges
Storage temperature
RT
MN732810
CHROMABOND Flash RS 4 C18 ec cartridges, 40–63 µm, 4.3 g
Special offer
Add to Cart
Hazardous material
No
Method
Flash chromatography
Brand
CHROMABOND
Phase
C18 ec
Mode
Reversed phase (RP)
Base material
Silica gel
Surface chemistry
Octadecyl (ODS, C18 ec, RP18 ec) modified silica phase, endcapped
Endcapped
Hardware
Column type
Flash RS
Column length
10.6 cm
Column inner diameter
12.4 mm
Column connection
Female Luer lock inlet and male Luer tip outlet
Filling material
Irregular, 40–63 µm
Hardware
Polypropylene (PP)
Filling quantity
4.3 g
Recommended application(s)
Reversed phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
Particle type
Fully porous particles (FPP)
Particle size
40–63 µm
Pore size
60 Å
Particle shape
Irregular
Specific surface according to BET
500 m²/g
Removable closure
Non-removable
Typical flow rate
10–35 mL/min
pH stability
2.0–8.0
Pressure stability (max)
21 bar
Filter element material
Polyethylene (PE)
Scope of delivery
2x CHROMABOND Flash RS cartridges
Storage temperature
RT
MN732811
CHROMABOND Flash RS 15 C18 ec cartridges, 40–63 µm, 16.4 g
Special offer
Add to Cart
Hazardous material
No
Method
Flash chromatography
Brand
CHROMABOND
Phase
C18 ec
Mode
Reversed phase (RP)
Base material
Silica gel
Surface chemistry
Octadecyl (ODS, C18 ec, RP18 ec) modified silica phase, endcapped
Endcapped
Hardware
Column type
Flash RS
Column length
12.5 cm
Column inner diameter
21.2 mm
Column connection
Female Luer lock inlet and male Luer tip outlet
Filling material
Irregular, 40–63 µm
Hardware
Polypropylene (PP)
Filling quantity
16.4 g
Recommended application(s)
Reversed phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
Particle type
Fully porous particles (FPP)
Particle size
40–63 µm
Pore size
60 Å
Particle shape
Irregular
Specific surface according to BET
500 m²/g
Removable closure
Non-removable
Typical flow rate
25–55 mL/min
pH stability
2.0–8.0
Pressure stability (max)
21 bar
Filter element material
Polyethylene (PE)
Scope of delivery
1x CHROMABOND Flash RS cartridge
Storage temperature
RT