+852-3069 6950
css@gugent.com.hk
 

About 30 years ago MACHEREY‑NAGEL designed and introduced CHROMABOND SPE cartridges containing silica-based adsorbents.

SPE is a form of digital (step-wise) chromatography designed to extract, partition, and / or adsorb one or more components from a liquid phase (sample) onto a stationary phase (adsorbent or resin). An adsorbed substance can be removed from the adsorbent by stepwise increase of elution strength of the eluent (step gradient technique).

SPE extends a chromatographic system’s lifetime, improves qualitative and quantitative analysis, and the demand placed on an analytical instrument is considerably lessened.


Catalog No. Product Net Price
MN732983 CHROMABOND Flash DL 40, empty cartridges, 75 mL, 17.1 cm L, 26.4 mm ID Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Flash - accessory
  • Brand
  • CHROMABOND
  • Column type
  • Empty Flash column/cartridge
  • Column length
  • 17.6 cm
  • Column inner diameter
  • 26.7 mm
  • Hardware
  • Polypropylene (PP)
  • Filling quantity
  • No filling
  • Recommended application(s)
  • Flash chromatography (efficient liquid column chromatographic method for preparative applications in the gram range), Flash Direct Load cartridges - empty columns for solid injection
  • Filter element material
  • Polyethylene (PE)
  • Scope of delivery
  • 20x empty Flash cartridges/columns with 20x3 filter elements
  • Storage temperature
  • RT
MN732984 CHROMABOND Flash DL 80, empty cartridges, 160 mL, 24.0 cm L, 30.8 mm ID Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Flash - accessory
  • Brand
  • CHROMABOND
  • Column type
  • Empty Flash column/cartridge
  • Column length
  • 24.9 cm
  • Column inner diameter
  • 30.9 mm
  • Hardware
  • Polypropylene (PP)
  • Filling quantity
  • No filling
  • Recommended application(s)
  • Flash chromatography (efficient liquid column chromatographic method for preparative applications in the gram range), Flash Direct Load cartridges - empty columns for solid injection
  • Filter element material
  • Polyethylene (PE)
  • Scope of delivery
  • 20x empty Flash cartridges/columns with 20x3 filter elements
  • Storage temperature
  • RT
MN732985 CHROMABOND Flash DL 120, empty cartridges, 220 mL, 25.5 cm L, 36.0 mm ID Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Flash - accessory
  • Brand
  • CHROMABOND
  • Column type
  • Empty Flash column/cartridge
  • Column length
  • 26.2 cm
  • Column inner diameter
  • 37.2 mm
  • Hardware
  • Polypropylene (PP)
  • Filling quantity
  • No filling
  • Recommended application(s)
  • Flash chromatography (efficient liquid column chromatographic method for preparative applications in the gram range), Flash Direct Load cartridges - empty columns for solid injection
  • Filter element material
  • Polyethylene (PE)
  • Scope of delivery
  • 20x empty Flash cartridges/columns with 20x3 filter elements
  • Storage temperature
  • RT
MN732986 CHROMABOND Flash DL 200, empty cartridges, 410 mL, 20.0 cm L, 60.0 mm ID Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Flash - accessory
  • Brand
  • CHROMABOND
  • Column type
  • Empty Flash column/cartridge
  • Column length
  • 21.6 cm
  • Column inner diameter
  • 59.4 mm
  • Hardware
  • Polypropylene (PP)
  • Filling quantity
  • No filling
  • Recommended application(s)
  • Flash chromatography (efficient liquid column chromatographic method for preparative applications in the gram range), Flash Direct Load cartridges - empty columns for solid injection
  • Filter element material
  • Polyethylene (PE)
  • Scope of delivery
  • 10x empty Flash cartridges/columns with 10x3 filter elements
  • Storage temperature
  • RT
MN732987 CHROMABOND Flash DL 330, empty cartridges, 600 mL, 27.0 cm L, 60.0 mm ID Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Flash - accessory
  • Brand
  • CHROMABOND
  • Column type
  • Empty Flash column/cartridge
  • Column length
  • 28.0 cm
  • Column inner diameter
  • 59.4 mm
  • Hardware
  • Polypropylene (PP)
  • Filling quantity
  • No filling
  • Recommended application(s)
  • Flash chromatography (efficient liquid column chromatographic method for preparative applications in the gram range), Flash Direct Load cartridges - empty columns for solid injection
  • Filter element material
  • Polyethylene (PE)
  • Scope of delivery
  • 10x empty Flash cartridges/columns with 10x3 filter elements
  • Storage temperature
  • RT
MN732800 CHROMABOND Flash RS 4 SiOH cartridges, 40–63 µm, 4 g Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Flash chromatography
  • Brand
  • CHROMABOND
  • Phase
  • SiOH
  • Mode
  • Normal phase (NP)
  • Base material
  • Silica gel
  • Surface chemistry
  • Unmodified silica gel (SiOH)
  • Endcapped
  • No
  • Column type
  • Flash RS
  • Column length
  • 10.6 cm
  • Column inner diameter
  • 12.4 mm
  • Column connection
  • Female Luer lock inlet and male Luer tip outlet
  • Filling material
  • Irregular, 40–63 µm
  • Hardware
  • Polypropylene (PP)
  • Filling quantity
  • 4 g
  • Recommended application(s)
  • Normal phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 40–63 µm
  • Pore size
  • 60 Å
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • Removable closure
  • Non-removable
  • Typical flow rate
  • 10–35 mL/min
  • pH stability
  • 2.0–8.0
  • Pressure stability (max)
  • 21 bar
  • Filter element material
  • Polyethylene (PE)
  • Scope of delivery
  • 20x CHROMABOND Flash RS cartridges
  • Storage temperature
  • RT
MN732801 CHROMABOND Flash RS 15 SiOH cartridges, 40–63 µm, 15 g Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Flash chromatography
  • Brand
  • CHROMABOND
  • Phase
  • SiOH
  • Mode
  • Normal phase (NP)
  • Base material
  • Silica gel
  • Surface chemistry
  • Unmodified silica gel (SiOH)
  • Endcapped
  • No
  • Column type
  • Flash RS
  • Column length
  • 12.5 cm
  • Column inner diameter
  • 21.2 mm
  • Column connection
  • Female Luer lock inlet and male Luer tip outlet
  • Filling material
  • Irregular, 40–63 µm
  • Hardware
  • Polypropylene (PP)
  • Filling quantity
  • 15 g
  • Recommended application(s)
  • Normal phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 40–63 µm
  • Pore size
  • 60 Å
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • Removable closure
  • Non-removable
  • Typical flow rate
  • 25–55 mL/min
  • pH stability
  • 2.0–8.0
  • Pressure stability (max)
  • 21 bar
  • Filter element material
  • Polyethylene (PE)
  • Scope of delivery
  • 20x CHROMABOND Flash RS cartridges
  • Storage temperature
  • RT
MN732802 CHROMABOND Flash RS 25 SiOH cartridges, 40–63 µm, 25 g Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Flash chromatography
  • Brand
  • CHROMABOND
  • Phase
  • SiOH
  • Mode
  • Normal phase (NP)
  • Base material
  • Silica gel
  • Surface chemistry
  • Unmodified silica gel (SiOH)
  • Endcapped
  • No
  • Column type
  • Flash RS
  • Column length
  • 17.3 cm
  • Column inner diameter
  • 21.2 mm
  • Column connection
  • Female Luer lock inlet and male Luer tip outlet
  • Filling material
  • Irregular, 40–63 µm
  • Hardware
  • Polypropylene (PP)
  • Filling quantity
  • 25 g
  • Recommended application(s)
  • Normal phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 40–63 µm
  • Pore size
  • 60 Å
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • Removable closure
  • Non-removable
  • Typical flow rate
  • 25–55 mL/min
  • pH stability
  • 2.0–8.0
  • Pressure stability (max)
  • 21 bar
  • Filter element material
  • Polyethylene (PE)
  • Scope of delivery
  • 15x CHROMABOND Flash RS cartridges
  • Storage temperature
  • RT
MN732803 CHROMABOND Flash RS 40 SiOH cartridges, 40–63 µm, 40 g Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Flash chromatography
  • Brand
  • CHROMABOND
  • Phase
  • SiOH
  • Mode
  • Normal phase (NP)
  • Base material
  • Silica gel
  • Surface chemistry
  • Unmodified silica gel (SiOH)
  • Endcapped
  • No
  • Column type
  • Flash RS
  • Column length
  • 17.6 cm
  • Column inner diameter
  • 26.7 mm
  • Column connection
  • Female Luer lock inlet and male Luer tip outlet
  • Filling material
  • Irregular, 40–63 µm
  • Hardware
  • Polypropylene (PP)
  • Filling quantity
  • 40 g
  • Recommended application(s)
  • Normal phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 40–63 µm
  • Pore size
  • 60 Å
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • Removable closure
  • Non-removable
  • Typical flow rate
  • 35–65 mL/min
  • pH stability
  • 2.0–8.0
  • Pressure stability (max)
  • 21 bar
  • Filter element material
  • Polyethylene (PE)
  • Scope of delivery
  • 15x CHROMABOND Flash RS cartridges
  • Storage temperature
  • RT
MN732804 CHROMABOND Flash RS 80 SiOH cartridges, 40–63 µm, 80 g Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Flash chromatography
  • Brand
  • CHROMABOND
  • Phase
  • SiOH
  • Mode
  • Normal phase (NP)
  • Base material
  • Silica gel
  • Surface chemistry
  • Unmodified silica gel (SiOH)
  • Endcapped
  • No
  • Column type
  • Flash RS
  • Column length
  • 24.9 cm
  • Column inner diameter
  • 30.9 mm
  • Column connection
  • Female Luer lock inlet and male Luer tip outlet
  • Filling material
  • Irregular, 40–63 µm
  • Hardware
  • Polypropylene (PP)
  • Filling quantity
  • 80 g
  • Recommended application(s)
  • Normal phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 40–63 µm
  • Pore size
  • 60 Å
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • Removable closure
  • Non-removable
  • Typical flow rate
  • 45–95 mL/min
  • pH stability
  • 2.0–8.0
  • Pressure stability (max)
  • 14 bar
  • Filter element material
  • Polyethylene (PE)
  • Scope of delivery
  • 12x CHROMABOND Flash RS cartridges
  • Storage temperature
  • RT

Overview

Main steps of the SPE procedure

1) Conditioning

Conditioning of the adsorbent is necessary in order to ensure reproducible interaction with the analyte. Conditioning, also called solvation, results in a wetting of the adsorbent and thus produces an environment, which is suitable for adsorption of the analyte. Nonpolar adsorbents are usually conditioned with 2–3 column volumes of a solvent, which is miscible with water (methanol, THF, 2-propanol etc.), followed by the solvent in which the analyte is dissolved (pure matrix, e.g., water, buffer). Polar adsorbents are conditioned with nonpolar solvents. After the conditioning step the adsorbent bed must not run dry, because otherwise solvation is destroyed (deconditioning).


2) Sample application (adsorption)

Sample application can be performed with positive or negative pressure with a flow rate of ~3 mL/min. Sample volumes vary from a few mL up to liters.


3) Washing

Washing of the adsorbent is usually achieved with a special wash solution; however, in some cases it may not be necessary. If the polarity difference between wash solution and eluent is very large, or if both are not miscible, drying of the adsorbent bed after washing is recommended to improve elution and recovery.


4) Elution

Elution with a suitable eluent should not be too fast. The elution speed depends on the column or cartridge dimension and the quantity of adsorbent (about 1 mL/min).


Since analytes can either be adsorbed on the SPE packing material or directly flown through while the interfering substances are retained, two general separation procedures are possible – both cases are shown in the figure below.



Resources