MN732805
CHROMABOND Flash RS 120 SiOH cartridges, 40–63 µm, 120 g
Special offer
Add to Cart
Hazardous material
No
Method
Flash chromatography
Brand
CHROMABOND
Phase
SiOH
Mode
Normal phase (NP)
Base material
Silica gel
Surface chemistry
Unmodified silica gel (SiOH)
Endcapped
No
Column type
Flash RS
Column length
26.2 cm
Column inner diameter
37.2 mm
Column connection
Female Luer lock inlet and male Luer tip outlet
Filling material
Irregular, 40–63 µm
Hardware
Polypropylene (PP)
Filling quantity
120 g
Recommended application(s)
Normal phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
Particle type
Fully porous particles (FPP)
Particle size
40–63 µm
Pore size
60 Å
Particle shape
Irregular
Specific surface according to BET
500 m²/g
Removable closure
Non-removable
Typical flow rate
55–140 mL/min
pH stability
2.0–8.0
Pressure stability (max)
14 bar
Filter element material
Polyethylene (PE)
Scope of delivery
10x CHROMABOND Flash RS cartridges
Storage temperature
RT
MN732806
CHROMABOND Flash RS 200 SiOH cartridges, 40–63 µm, 200 g
Special offer
Add to Cart
Hazardous material
No
Method
Flash chromatography
Brand
CHROMABOND
Phase
SiOH
Mode
Normal phase (NP)
Base material
Silica gel
Surface chemistry
Unmodified silica gel (SiOH)
Endcapped
No
Column type
Flash RS
Column length
21.6 cm
Column inner diameter
59.4 mm
Column connection
Female Luer lock inlet and male Luer tip outlet
Filling material
Irregular, 40–63 µm
Hardware
Polypropylene (PP)
Filling quantity
200 g
Recommended application(s)
Normal phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
Particle type
Fully porous particles (FPP)
Particle size
40–63 µm
Pore size
60 Å
Particle shape
Irregular
Specific surface according to BET
500 m²/g
Removable closure
Non-removable
Typical flow rate
75–210 mL/min
pH stability
2.0–8.0
Pressure stability (max)
11 bar
Filter element material
Polyethylene (PE)
Scope of delivery
6x CHROMABOND Flash RS cartridges
Storage temperature
RT
MN732807
CHROMABOND Flash RS 330 SiOH cartridges, 40–63 µm, 330 g
Special offer
Add to Cart
Hazardous material
No
Method
Flash chromatography
Brand
CHROMABOND
Phase
SiOH
Mode
Normal phase (NP)
Base material
Silica gel
Surface chemistry
Unmodified silica gel (SiOH)
Endcapped
No
Column type
Flash RS
Column length
28.0 cm
Column inner diameter
59.8 mm
Column connection
Female Luer lock inlet and male Luer tip outlet
Filling material
Irregular, 40–63 µm
Hardware
Polypropylene (PP)
Filling quantity
330 g
Recommended application(s)
Normal phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
Particle type
Fully porous particles (FPP)
Particle size
40–63 µm
Pore size
60 Å
Particle shape
Irregular
Specific surface according to BET
500 m²/g
Removable closure
Non-removable
Typical flow rate
75–210 mL/min
pH stability
2.0–8.0
Pressure stability (max)
11 bar
Filter element material
Polyethylene (PE)
Scope of delivery
4x CHROMABOND Flash RS cartridges
Storage temperature
RT
MN732700
CHROMABOND Flash RS 4 SiOH cartridges, 15–40 µm, 4 g
Special offer
Add to Cart
Hazardous material
No
Method
Flash chromatography
Brand
CHROMABOND
Phase
SiOH
Mode
Normal phase (NP)
Base material
Silica gel
Surface chemistry
Unmodified silica gel (SiOH)
Endcapped
No
Column type
Flash RS
Column length
10.6 cm
Column inner diameter
12.4 mm
Column connection
Female Luer lock inlet and male Luer tip outlet
Filling material
Irregular, 15–40 µm
Hardware
Polypropylene (PP)
Filling quantity
4 g
Recommended application(s)
Normal phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
Particle type
Fully porous particles (FPP)
Particle size
15–40 µm
Pore size
60 Å
Particle shape
Irregular
Specific surface according to BET
500 m²/g
Removable closure
Non-removable
Typical flow rate
10–50 mL/min
pH stability
2.0–8.0
Pressure stability (max)
21 bar
Filter element material
Polyethylene (PE)
Scope of delivery
20x CHROMABOND Flash RS cartridges
Storage temperature
RT
MN732701
CHROMABOND Flash RS 15 SiOH cartridges, 15–40 µm, 15 g
Special offer
Add to Cart
Hazardous material
No
Method
Flash chromatography
Brand
CHROMABOND
Phase
SiOH
Mode
Normal phase (NP)
Base material
Silica gel
Surface chemistry
Unmodified silica gel (SiOH)
Endcapped
No
Column type
Flash RS
Column length
12.5 cm
Column inner diameter
21.2 mm
Column connection
Female Luer lock inlet and male Luer tip outlet
Filling material
Irregular, 15–40 µm
Hardware
Polypropylene (PP)
Filling quantity
15 g
Recommended application(s)
Normal phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
Particle type
Fully porous particles (FPP)
Particle size
15–40 µm
Pore size
60 Å
Particle shape
Irregular
Specific surface according to BET
500 m²/g
Removable closure
Non-removable
Typical flow rate
25–70 mL/min
pH stability
2.0–8.0
Pressure stability (max)
21 bar
Filter element material
Polyethylene (PE)
Scope of delivery
20x CHROMABOND Flash RS cartridges
Storage temperature
RT
MN732702
CHROMABOND Flash RS 25 SiOH cartridges, 15–40 µm, 25 g
Special offer
Add to Cart
Hazardous material
No
Method
Flash chromatography
Brand
CHROMABOND
Phase
SiOH
Mode
Normal phase (NP)
Base material
Silica gel
Surface chemistry
Unmodified silica gel (SiOH)
Endcapped
No
Column type
Flash RS
Column length
17.3 cm
Column inner diameter
21.2 mm
Column connection
Female Luer lock inlet and male Luer tip outlet
Filling material
Irregular, 15–40 µm
Hardware
Polypropylene (PP)
Filling quantity
25 g
Recommended application(s)
Normal phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
Particle type
Fully porous particles (FPP)
Particle size
15–40 µm
Pore size
60 Å
Particle shape
Irregular
Specific surface according to BET
500 m²/g
Removable closure
Non-removable
Typical flow rate
25–70 mL/min
pH stability
2.0–8.0
Pressure stability (max)
21 bar
Filter element material
Polyethylene (PE)
Scope of delivery
15x CHROMABOND Flash RS cartridges
Storage temperature
RT
MN732703
CHROMABOND Flash RS 40 SiOH cartridges, 15–40 µm, 40 g
Special offer
Add to Cart
Hazardous material
No
Method
Flash chromatography
Brand
CHROMABOND
Phase
SiOH
Mode
Normal phase (NP)
Base material
Silica gel
Surface chemistry
Unmodified silica gel (SiOH)
Endcapped
No
Column type
Flash RS
Column length
17.6 cm
Column inner diameter
26.7 mm
Column connection
Female Luer lock inlet and male Luer tip outlet
Filling material
Irregular, 15–40 µm
Hardware
Polypropylene (PP)
Filling quantity
40 g
Recommended application(s)
Normal phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
Particle type
Fully porous particles (FPP)
Particle size
15–40 µm
Pore size
60 Å
Particle shape
Irregular
Specific surface according to BET
500 m²/g
Removable closure
Non-removable
Typical flow rate
35–80 mL/min
pH stability
2.0–8.0
Pressure stability (max)
21 bar
Filter element material
Polyethylene (PE)
Scope of delivery
15x CHROMABOND Flash RS cartridges
Storage temperature
RT
MN732704
CHROMABOND Flash RS 80 SiOH cartridges, 15–40 µm, 80 g
Special offer
Add to Cart
Hazardous material
No
Method
Flash chromatography
Brand
CHROMABOND
Phase
SiOH
Mode
Normal phase (NP)
Base material
Silica gel
Surface chemistry
Unmodified silica gel (SiOH)
Endcapped
No
Column type
Flash RS
Column length
24.9 cm
Column inner diameter
30.9 mm
Column connection
Female Luer lock inlet and male Luer tip outlet
Filling material
Irregular, 15–40 µm
Hardware
Polypropylene (PP)
Filling quantity
80 g
Recommended application(s)
Normal phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
Particle type
Fully porous particles (FPP)
Particle size
15–40 µm
Pore size
60 Å
Particle shape
Irregular
Specific surface according to BET
500 m²/g
Removable closure
Non-removable
Typical flow rate
45–105 mL/min
pH stability
2.0–8.0
Pressure stability (max)
14 bar
Filter element material
Polyethylene (PE)
Scope of delivery
12x CHROMABOND Flash RS cartridges
Storage temperature
RT
MN732705
CHROMABOND Flash RS 120 SiOH cartridges, 15–40 µm, 120 g
Special offer
Add to Cart
Hazardous material
No
Method
Flash chromatography
Brand
CHROMABOND
Phase
SiOH
Mode
Normal phase (NP)
Base material
Silica gel
Surface chemistry
Unmodified silica gel (SiOH)
Endcapped
No
Column type
Flash RS
Column length
26.2 cm
Column inner diameter
37.2 mm
Column connection
Female Luer lock inlet and male Luer tip outlet
Filling material
Irregular, 15–40 µm
Hardware
Polypropylene (PP)
Filling quantity
120 g
Recommended application(s)
Normal phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
Particle type
Fully porous particles (FPP)
Particle size
15–40 µm
Pore size
60 Å
Particle shape
Irregular
Specific surface according to BET
500 m²/g
Removable closure
Non-removable
Typical flow rate
55–155 mL/min
pH stability
2.0–8.0
Pressure stability (max)
14 bar
Filter element material
Polyethylene (PE)
Scope of delivery
10x CHROMABOND Flash RS cartridges
Storage temperature
RT
MN732706
CHROMABOND Flash RS 200 SiOH cartridges, 15–40 µm, 200 g
Special offer
Add to Cart
Hazardous material
No
Method
Flash chromatography
Brand
CHROMABOND
Phase
SiOH
Mode
Normal phase (NP)
Base material
Silica gel
Surface chemistry
Unmodified silica gel (SiOH)
Endcapped
No
Column type
Flash RS
Column length
21.6 cm
Column inner diameter
59.4 mm
Column connection
Female Luer lock inlet and male Luer tip outlet
Filling material
Irregular, 15–40 µm
Hardware
Polypropylene (PP)
Filling quantity
200 g
Recommended application(s)
Normal phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
Particle type
Fully porous particles (FPP)
Particle size
15–40 µm
Pore size
60 Å
Particle shape
Irregular
Specific surface according to BET
500 m²/g
Removable closure
Non-removable
Typical flow rate
75–255 mL/min
pH stability
2.0–8.0
Pressure stability (max)
11 bar
Filter element material
Polyethylene (PE)
Scope of delivery
6x CHROMABOND Flash RS cartridges
Storage temperature
RT