Agilent Inductively Coupled Plasma Mass Spectrometry (ICP-MS) is available in single quadrupole and triple quadrupole configurations. Our single quadrupole ICP-MS address the range of typical ICP-MS measurements from routine, regulated analysis to advanced research and demanding applications. Our triple quadrupole ICP-MS will give you the confidence of knowing you can resolve problematic interferences – even in your most difficult samples – delivering results you know you can trust.

Catalog No. Product Net Price
G8014-68005 O-ring kit for inert spray chamber (p/n G8014-68002). Includes O-rings, 3/pk 23 
Add to Cart
  • UNSPSC Code
  • 411130000
  • Where Used
  • Spray Chamber
G8014-68007 Drain connector, 10/32UNF to Luer Slip, for inert spray chamber (p/n G8014-68002). Includes O-ring and Leur slip for inert spray chamber drain fitting. 6 
Add to Cart
  • UNSPSC Code
  • 411130000
  • Where Used
  • Spray Chamber
G8460-68001 Adaptor kit to fit inert spray shamber (p/n G8014-68002) for the Agilent 700, Vista, and Liberty series ICP-OES. Includes mounting bracket and a ball joint adapter that connects to the FEP transfer tube. 244 
Add to Cart
  • UNSPSC Code
  • 411130000
G3285-80020 PFA end cap for Scott PFA spray chamber, with makeup gas port, suits inert sample introduction kit. Suits Agilent 7500, 7700, 7800, 7850, 7900, 8800, 8900 ICP-MS with PFA inert kit. 560 
Add to Cart
  • UNSPSC Code
  • 41115411
G1820-65515 Drain Tubing for aqueous or organic waste, ETFE core, 4 mm id, 6mm OD, 2.5 m length per unit. Suitable for use for aqueous or organic samples from spray chamber drain peristaltic pump tubing or Autosampler drain to waste vessel. Used with all Agilent ICP 90 
Add to Cart
  • Inner Diameter (ID)
  • 4 mm
  • Length
  • 2.5 m
  • UNSPSC Code
  • 41115411
  • Fittings
  • None
  • Tubing Material
  • ETFE
  • Tubing OD
  • 6 mm
  • Where Used
  • Waste
G3280-60008 End cap for Scott spray chamber. Suitable for use with Agilent 7700, 7800, 7850, 7900, 8800, 8900 ICP-MS 273 
Add to Cart
  • UNSPSC Code
  • 41115411
G3280-60077 Drain Tubing for aqueous waste, PVC Tygon®, 3 mm id, 6 mm OD, 3 m length per unit. Suitable for use for aqueous samples from spray chamber drain peristaltic pump tubing or Autosampler drain to waste vessel. Used with all Agilent ICP-MS models. 96 
Add to Cart
  • Inner Diameter (ID)
  • 3.17 mm
  • Length
  • 3 m
  • UNSPSC Code
  • 41115411
  • Fittings
  • None
  • Tubing Material
  • Tygon
  • Where Used
  • Waste
G3280-80008 Quartz Spray chamber, Scott double-pass, standard for Agilent 7500, 7700, 7800 and 8800. For use with HMI or no aerosol gas dilution. Also suits 7850 / 7900 / 8900 if UHMI capability is not required. Requires End Cap G3280-60008 529 
Add to Cart
  • UNSPSC Code
  • 41115411
  • Chemical Compatibility
  • Aqueous Organic solvents
  • Material
  • Quartz
  • Type
  • Scott style
G3280-80503 Quartz Spray chamber with fixed connector to torch, Scott double-pass, recommended for ultra-trace analysis of Boron. For use without aerosol gas dilution, not compatible with HMI or UHMI. Optional on all Agilent ICP-MS. Requires End Cap G3280-60008 1448 
Add to Cart
  • UNSPSC Code
  • 41115411
  • Chemical Compatibility
  • Aqueous Organic solvents
  • Material
  • Quartz
  • Type
  • Scott style
G8400-40200 End cap locking ring for spray chamber, for Agilent 7900 and 8900 ICP-MS with UHMI. Used with G8400-67150 spray chamber 19 
Add to Cart
  • UNSPSC Code
  • 41113000

Overview

ICP-MS system operates with an ICP-MS Nebulizer, in which a high velocity Argon gas stream meets a liquid stream causing filmwise breakup of the solution into a fine aerosol. The aerosol particle size should ideally be sub-10µm with a narrow particle size distribution to achieve efficient atomization and ionization. Agilent offers a comprehensive range of ICP-MS nebulizers and supplies to solve any ICP-MS analysis challenge.

The portfolio includes standard glass concentric nebulizer (MicroMist), quartz and inert PFA nebulizers (MicroFlow and C-Flow), as well as robust Mira Mist PEEK or PTFE for high TDS samples and low-flow self-aspirating or total consumption nebulizers for your clinical or limited volume samples. ICP-MS nebulizer support is provided with a full range of accessories for all models including nebulizer cleaning tools.


The ICP torch is used to form, shape, and sustain an argon plasma which atomizes and ionizes the sample aerosol. Agilent ICP-MS Torches with Shield Torch System (STS) provide precise ion energy control, ensuring high sensitivity and stability, even in cool plasma mode for effective interference removal (ArO+).

Our portfolio is comprised of a wide range of ICP torches for your specific ICP-MS configuration. One-piece quartz torches offer the best stability and ease of use. The large 2.5mm injector on the standard torch gives maximum robustness and lowest matrix interferences for the best plasma stability. Single-piece torches with narrow bore injectors (1.0mm or 1.5 mm) are designed for use with organic solvents, to reduce plasma loading and improve plasma stability. Optional semi-demountable quartz torches with removable platinum or sapphire injectors are also available for use with the PFA inert sample introduction kit.


Resources