Agilent Inductively Coupled Plasma Mass Spectrometry (ICP-MS) is available in single quadrupole and triple quadrupole configurations. Our single quadrupole ICP-MS address the range of typical ICP-MS measurements from routine, regulated analysis to advanced research and demanding applications. Our triple quadrupole ICP-MS will give you the confidence of knowing you can resolve problematic interferences – even in your most difficult samples – delivering results you know you can trust.

Catalog No. Product Net Price
AGIL410328600 Bracket for mounting Sturman-Masters spray chamber on 700, Vista and Liberty series axial ICP-OES. Bracket for mounting Sturman-Masters spray chamber on 700, Vista and Liberty series axial ICP-OES 710/720/730 axial, Vista-PRO axial, Vista-MPX axial and 129 
Add to Cart
  • UNSPSC Code
  • 41113000
AGIL6910001200 O-ring for nebulizer inlet of single and double-pass spray chamber. O RING 1/4 inch ID X 3/8 od X 1/16 inch. 5 
Add to Cart
  • Inner Diameter (ID)
  • 6.35 mm
  • Outer Diameter (OD)
  • 9.53 mm
  • Where Used
  • Spray Chamber
G8000-64140 Clamp for torch with ball joint socket used with MP-AES/ICP-OES 66 
Add to Cart
  • UNSPSC Code
  • 41115406
  • Notes
  • Secures ball joint socket between spray chamber and torch on 5100/5110 ICP-OESNot suitable for use with the inert torch Not suitable for use with the inert torch -->
G8010-60227 Clamp for ball joint connector between spray chamber and inert torch, for Agilent MP-AES. Ensures gas-tight seal on ball joint connector, suitable for use with inert torch. 82 
Add to Cart
  • UNSPSC Code
  • 41113000
G8010-68011 PuraFlex transfer tube for IsoMist used with Agilent 5000 series ICP-OES. Required to connect aerosol outlet from IsoMist temperature-controlled spray chamber to Easy-fit torch 366 
Add to Cart
  • UNSPSC Code
  • 41113000
  • Notes
  • Connects the aerosol outlet from the IsoMist to the Easy-fit ICP-OES torch
G8010-68023 Drain fitting, right-angle, UniFit, for waste outlet from IsoMist spray chamber, 3/pk 145 
Add to Cart
  • UNSPSC Code
  • 41113000
  • Notes
  • For waste outlet of IsoMist spray chamber
  • Where Used
  • Spray Chamber
G8010-68024 Spray chamber, ICP, twister style (double-pass) cyclonic, with thermal conductive polymer encapsulation, for IsoMist with RoL configuration. Requires transfer tube (PN G8010-68011) to connect the aerosol outlet to the ICP-OES torch. 1210 
Add to Cart
  • UNSPSC Code
  • 41113000
  • Chemical Compatibility
  • Aqueous Organic solvents
  • Material
  • Borosilicate Glass
  • Notes
  • Twister style (double pass) glass cyclonic with thermal conductive polymer encapsulation for use with IsoMist for 5100/5110 ICP-OES (RoL configuration)Will not fit the IsoMist for the 4200/4210 MP-AES Will not fit the IsoMist for the 4200/4210 MP-AES -->
  • Type
  • Double pass
G8010-80036 UniFit drain connector, 2.0 mm od x 0.86 mm id, for spray chamber used with Agilent 5000 Series ICP-OES, with 480 mm capillary tubing, 3/pk 90 
Add to Cart
  • Inner Diameter (ID)
  • 0.86 mm
  • Length
  • 480 mm
  • UNSPSC Code
  • 41113000
  • Notes
  • Connects the peristaltic pump tubing for the waste line to the spray chamber outlet
  • Outer Diameter (OD)
  • 2 mm
  • Where Used
  • Spray Chamber
G8010-80036 UniFit drain connector, 2.0 mm od x 0.86 mm id, for spray chamber used with Agilent 5000 Series ICP-OES, with 480 mm capillary tubing, 3/pk 90 
Add to Cart
  • Inner Diameter (ID)
  • 0.86 mm
  • Length
  • 480 mm
  • UNSPSC Code
  • 41113000
  • Notes
  • Connects the peristaltic pump tubing for the waste line to the spray chamber outlet
  • Outer Diameter (OD)
  • 2 mm
  • Where Used
  • Spray Chamber
G8014-20002 Replacement baffle (internal), for inert spray chamber (p/n G8014-68002). Used with 5000 series ICP-OES and MP-AES 127 
Add to Cart
  • UNSPSC Code
  • 411130000

Overview

ICP-MS system operates with an ICP-MS Nebulizer, in which a high velocity Argon gas stream meets a liquid stream causing filmwise breakup of the solution into a fine aerosol. The aerosol particle size should ideally be sub-10µm with a narrow particle size distribution to achieve efficient atomization and ionization. Agilent offers a comprehensive range of ICP-MS nebulizers and supplies to solve any ICP-MS analysis challenge.

The portfolio includes standard glass concentric nebulizer (MicroMist), quartz and inert PFA nebulizers (MicroFlow and C-Flow), as well as robust Mira Mist PEEK or PTFE for high TDS samples and low-flow self-aspirating or total consumption nebulizers for your clinical or limited volume samples. ICP-MS nebulizer support is provided with a full range of accessories for all models including nebulizer cleaning tools.


The ICP torch is used to form, shape, and sustain an argon plasma which atomizes and ionizes the sample aerosol. Agilent ICP-MS Torches with Shield Torch System (STS) provide precise ion energy control, ensuring high sensitivity and stability, even in cool plasma mode for effective interference removal (ArO+).

Our portfolio is comprised of a wide range of ICP torches for your specific ICP-MS configuration. One-piece quartz torches offer the best stability and ease of use. The large 2.5mm injector on the standard torch gives maximum robustness and lowest matrix interferences for the best plasma stability. Single-piece torches with narrow bore injectors (1.0mm or 1.5 mm) are designed for use with organic solvents, to reduce plasma loading and improve plasma stability. Optional semi-demountable quartz torches with removable platinum or sapphire injectors are also available for use with the PFA inert sample introduction kit.


Resources