+852-3069 6950
sales@gugent.com.hk
 

Water or air, measure H2S where it matters – right at the source.


Meet the new GS1440 and GS1440EX hydrogen sulfide sensors from Hach. Whether in water or air, you will have the direct H2S measurement you need to optimize your H2S treatment process and proactively control H2S before it causes issues.

Catalog No. Product Net Price
LXV323.99.30002 TSS sc Turbidity and Suspended Solids Inline Probe, Stainless Steel 6913 
Add to Cart
  • Automatic Wiper
  • No
  • Cable Length
  • 10 m (optional extension cables available)
  • Calibration Method
  • Turbidity Formazin or StablCal® Standard (at 800 NTU). Requires a calibration kit. Suspended Solids Sample specific, based on gravimetric analysis with a correction factor procedure.
  • Flow
  • Max. 3 m/s (the presence of air bubbles affects the measurement)
  • Length
  • 332 mm
  • Maintenance Interval
  • 1 h/month
  • Material
  • Optics Carrier and Sleeve: stainless steel 1.4460 / stainless steel 1.4571
  • Max. cable length Sensor-to-Controller
  • 100
  • Measuring Principle
  • Turbidity: 2-channel 90° scattered light measurement in accordance with DIN/EN 27027/ISO7027TSS: Modified absorption measurementEight-channel multiple-angle measurement, wavelength = 860 nm
  • Model
  • TSS sc
  • Operating Temperature Range
  • 0 - 60 °C
  • Parameter
  • Turbidity, Suspended Solids
  • Pressure Range
  • < 10 bar or < 100 m
  • Range
  • Turbidity (TRB): 0.001 - 9999 NTUSolids (TSS): 0.001 - 500 g/L
  • Repeatability
  • TSS content: < 4 %Turbidity: < 3 %
  • Response Time T90
  • 1 - 300 s adjustable
  • Special Notes
  • Installation note:Distance sensor–wall > 10 cm (TSS)
  • Warranty
  • 12 months
  • Weight
  • Approx. 1.6 kg
  • What's included?
  • Turbidity & Suspended Solids sensor, user manual
HACH08362=A=1111 8362 Ultrapure Water ORP Sensor 1818 
Add to Cart
  • Cable Length
  • 3 m Cable Length
  • Flow
  • 100 - 400 mL/min
  • Material
  • Housing: Polyester Coated AluminiumScrews: Stainless Steel
  • Operating Temperature Range
  • -20 - 60 °C
  • Pressure Range
  • Maximum Pressure: 16 bar at 25 °C, 6 bar at 100 °C
  • Range
  • -1500 - 1500
  • Warranty
  • 6 months
  • Weight
  • 0.9 kg
  • What's included?
  • 8362 analog ORP sensor, instruction manual
HACH6178001 8362sc High Purity Water ORP Panel 2275 
Add to Cart
  • Cable Length
  • 7.7 m (25 ft.), supplied
  • Operating Temperature Range
  • 0 - 60 °C
  • Parameter
  • ORP
  • Range
  • -1500 - 1500 mV at 0 - 80°C (32 - 176°F)
  • Repeatability
  • ± 2 mV at 25°C (constant flow)
  • Warranty
  • 12 months
  • Weight
  • 3.6 kg
  • What's included?
  • Includes: sensor, junction box, flow meter, mounting assembly and manual
HACH9582.99.73P4 Hach 9582sc Dissolved Oxygen System with Profibus DP Communications, 24 V DC Special offer 
Add to Cart
  • Cable Length
  • 10 m (33 ft)
  • Calibration Method
  • Zero: Electrically or with oxygen free water, Slope: in air or against a laboratory measurement
  • Communication Capabilities
  • Profibus DP (includes sculpted barrier)
  • Conduit Openings
  • 1/2" NPT Conduit
  • Display
  • Graphic dot matrix LCD with LED backlighting, transreflective
  • Enclosure Rating
  • IP66 / NEMA 4X
  • Maintenance Interval
  • Membrane Lifetime: 6 months depending on sample
  • Material
  • Electrodes: Gold cathode, Silver anode; Flow-through cell: Stainless Steel 316L; Membrane: PFA, Sensor Body: Noryl
  • Material Enclosures
  • PolycarbonateAluminium (powder coated)Stainless Steel
  • Measurements
  • 0 to 2000 ppb (0-2 ppm)
  • Operating Temperature Range
  • -20 - 60 °C at 0 - 95% RH (non-condensing)
  • Power Requirements (Voltage)
  • 24 V DC
  • Range
  • 0 - 2000 ppb (0-2 ppm)
  • Relays
  • Four electromechanical SPDT (Form C) contacts, 1200 W, 5 A
  • Repeatability
  • ± 0.5 ppb or ±5%, whichever is greater
  • Storage Conditions
  • -20 °C to 70 °C
  • Weight
  • 3.2 kg
  • What's included?
  • Controller, Mounting Hardware, Oxygen sensor, Temperature Sensor, Cable, Flow-Chamber, Basic User Manual
HACH9582.99.79P4 Polymetron 9582 Dissolved Oxygen System with 4-20mA Output Communications, 24 V DC Special offer 
Add to Cart
  • Cable Length
  • 10 m (33 ft)
  • Calibration Method
  • Zero: Electrically or with oxygen free water, Slope: in air or against a laboratory measurement
  • Communication Capabilities
  • 5x 4-20mA Out
  • Conduit Openings
  • 1/2" NPT Conduit
  • Display
  • Graphic dot matrix LCD with LED backlighting, transreflective
  • Enclosure Rating
  • IP66 / NEMA 4X
  • Maintenance Interval
  • Membrane Lifetime: 6 months depending on sample
  • Material
  • Electrodes: Gold cathode, Silver anode; Flow-through cell: Stainless Steel 316L; Membrane: PFA, Sensor Body: Noryl
  • Material Enclosures
  • PolycarbonateAluminium (powder coated)Stainless Steel
  • Measurements
  • 0 to 2000 ppb (0-2 ppm)
  • Operating Temperature Range
  • -20 - 60 °C at 0 - 95% RH (non-condensing)
  • Power Requirements (Voltage)
  • 24 V DC
  • Range
  • 0 - 2000 ppb (0-2 ppm)
  • Relays
  • Four electromechanical SPDT (Form C) contacts, 1200 W, 5 A
  • Repeatability
  • ± 0.5 ppb or ±5%, whichever is greater
  • Storage Conditions
  • -20 °C to 70 °C
  • Weight
  • 3.2 kg
  • What's included?
  • Controller, Mounting Hardware, Oxygen sensor, Temperature Sensor, Cable, Flow-Chamber, Basic User Manual
HACH9582.99.09P4 Polymetron 9582 Dissolved Oxygen System with 4-20mA Output Communications, AC-DC Special offer 
Add to Cart
  • Cable Length
  • 10 m (33 ft)
  • Calibration Method
  • Zero: Electrically or with oxygen free water, Slope: in air or against a laboratory measurement
  • Communication Capabilities
  • 5x 4-20mA Out
  • Conduit Openings
  • 1/2" NPT Conduit
  • Display
  • Graphic dot matrix LCD with LED backlighting, transreflective
  • Enclosure Rating
  • IP66 / NEMA 4X
  • Maintenance Interval
  • Membrane Lifetime: 6 months depending on sample
  • Material
  • Electrodes: Gold cathode, Silver anode; Flow-through cell: Stainless Steel 316L; Membrane: PFA, Sensor Body: Noryl
  • Material Enclosures
  • PolycarbonateAluminium (powder coated)Stainless Steel
  • Measurements
  • 0 to 2000 ppb (0-2 ppm)
  • Operating Temperature Range
  • -20 - 60 °C at 0 - 95% RH (non-condensing)
  • Power Requirements (Voltage)
  • 100 - 240 VAC
  • Range
  • 0 - 2000 ppb (0-2 ppm)
  • Relays
  • Four electromechanical SPDT (Form C) contacts, 1200 W, 5 A
  • Repeatability
  • ± 0.5 ppb or ±5%, whichever is greater
  • Storage Conditions
  • -20 °C to 70 °C
  • Weight
  • 3.2 kg
  • What's included?
  • Controller, Mounting Hardware, Oxygen sensor, Temperature Sensor, Cable, Flow-Chamber, Basic User Manual
HACH9582.99.75P4 Polymetron 9582 Dissolved Oxygen System with HART Communications, 24 V DC Special offer 
Add to Cart
  • Cable Length
  • 10 m (33 ft)
  • Calibration Method
  • Zero: Electrically or with oxygen free water, Slope: in air or against a laboratory measurement
  • Communication Capabilities
  • Hart
  • Conduit Openings
  • 1/2" NPT Conduit
  • Display
  • Graphic dot matrix LCD with LED backlighting, transreflective
  • Enclosure Rating
  • IP66 / NEMA 4X
  • Maintenance Interval
  • Membrane Lifetime: 6 months depending on sample
  • Material
  • Electrodes: Gold cathode, Silver anode; Flow-through cell: Stainless Steel 316L; Membrane: PFA, Sensor Body: Noryl
  • Material Enclosures
  • PolycarbonateAluminium (powder coated)Stainless Steel
  • Measurements
  • 0 to 2000 ppb (0-2 ppm)
  • Operating Temperature Range
  • -20 - 60 °C at 0 - 95% RH (non-condensing)
  • Power Requirements (Voltage)
  • 24 V DC
  • Range
  • 0 - 2000 ppb (0-2 ppm)
  • Relays
  • Four electromechanical SPDT (Form C) contacts, 1200 W, 5 A
  • Repeatability
  • ± 0.5 ppb or ±5%, whichever is greater
  • Storage Conditions
  • -20 °C to 70 °C
  • Weight
  • 3.2 kg
  • What's included?
  • Controller, Mounting Hardware, Oxygen sensor, Temperature Sensor, Cable, Flow-Chamber, Basic User Manual
HACH9582.99.05P4 Polymetron 9582 Dissolved Oxygen System with HART Communications, AC-DC Special offer 
Add to Cart
  • Cable Length
  • 10 m (33 ft)
  • Calibration Method
  • Zero: Electrically or with oxygen free water, Slope: in air or against a laboratory measurement
  • Communication Capabilities
  • Hart
  • Conduit Openings
  • 1/2" NPT Conduit
  • Display
  • Graphic dot matrix LCD with LED backlighting, transreflective
  • Enclosure Rating
  • IP66 / NEMA 4X
  • Maintenance Interval
  • Membrane Lifetime: 6 months depending on sample
  • Material
  • Electrodes: Gold cathode, Silver anode; Flow-through cell: Stainless Steel 316L; Membrane: PFA, Sensor Body: Noryl
  • Material Enclosures
  • PolycarbonateAluminium (powder coated)Stainless Steel
  • Measurements
  • 0 to 2000 ppb (0-2 ppm)
  • Operating Temperature Range
  • -20 - 60 °C at 0 - 95% RH (non-condensing)
  • Power Requirements (Voltage)
  • 100 - 240 VAC
  • Range
  • 0 - 2000 ppb (0-2 ppm)
  • Relays
  • Four electromechanical SPDT (Form C) contacts, 1200 W, 5 A
  • Repeatability
  • ± 0.5 ppb or ±5%, whichever is greater
  • Storage Conditions
  • -20 °C to 70 °C
  • Warranty
  • 12 months
  • Weight
  • 3.2 kg
  • What's included?
  • Controller, Mounting Hardware, Oxygen sensor, Temperature Sensor, Cable, Flow-Chamber, Basic User Manual
HACH9582.99.71P4 Polymetron 9582 Dissolved Oxygen System with Modbus Communications, 24 V DC Special offer 
Add to Cart
  • Cable Length
  • 10 m (33 ft)
  • Calibration Method
  • Zero: Electrically or with oxygen free water, Slope: in air or against a laboratory measurement
  • Communication Capabilities
  • Modbus RS232/RS485
  • Conduit Openings
  • 1/2" NPT Conduit
  • Display
  • Graphic dot matrix LCD with LED backlighting, transreflective
  • Enclosure Rating
  • IP66 / NEMA 4X
  • Maintenance Interval
  • Membrane Lifetime: 6 months depending on sample
  • Material
  • Electrodes: Gold cathode, Silver anode; Flow-through cell: Stainless Steel 316L; Membrane: PFA, Sensor Body: Noryl
  • Material Enclosures
  • PolycarbonateAluminium (powder coated)Stainless Steel
  • Measurements
  • 0 to 2000 ppb (0-2 ppm)
  • Operating Temperature Range
  • -20 - 60 °C at 0 - 95% RH (non-condensing)
  • Power Requirements (Voltage)
  • 24 V DC
  • Range
  • 0 - 2000 ppb (0-2 ppm)
  • Relays
  • Four electromechanical SPDT (Form C) contacts, 1200 W, 5 A
  • Repeatability
  • ± 0.5 ppb or ±5%, whichever is greater
  • Storage Conditions
  • -20 °C to 70 °C
  • Weight
  • 3.2 kg
  • What's included?
  • Controller, Mounting Hardware, Oxygen sensor, Temperature Sensor, Cable, Flow-Chamber, Basic User Manual
HACH9582.99.70P4 Polymetron 9582 Dissolved Oxygen System, 24 V DC Special offer 
Add to Cart
  • Cable Length
  • 10 m (33 ft)
  • Calibration Method
  • Zero: Electrically or with oxygen free water, Slope: in air or against a laboratory measurement
  • Communication Capabilities
  • Standard (2x 4-20 mA outputs)
  • Conduit Openings
  • 1/2" NPT Conduit
  • Display
  • Graphic dot matrix LCD with LED backlighting, transreflective
  • Enclosure Rating
  • IP66 / NEMA 4X
  • Maintenance Interval
  • Membrane Lifetime: 6 months depending on sample
  • Material
  • Electrodes: Gold cathode, Silver anode; Flow-through cell: Stainless Steel 316L; Membrane: PFA, Sensor Body: Noryl
  • Material Enclosures
  • PolycarbonateAluminium (powder coated)Stainless Steel
  • Measurements
  • 0 to 2000 ppb (0-2 ppm)
  • Operating Temperature Range
  • -20 - 60 °C at 0 - 95% RH (non-condensing)
  • Power Requirements (Voltage)
  • 24 V DC
  • Range
  • 0 - 2000 ppb (0-2 ppm)
  • Relays
  • Four electromechanical SPDT (Form C) contacts, 1200 W, 5 A
  • Repeatability
  • ± 0.5 ppb or ±5%, whichever is greater
  • Storage Conditions
  • -20 °C to 70 °C
  • Warranty
  • 12 months
  • Weight
  • 3.2 kg
  • What's included?
  • Controller, Mounting Hardware, Oxygen sensor, Temperature Sensor, Cable, Flow-Chamber, Basic User Manual

Related Categories