Meet the new GS1440 and GS1440EX hydrogen sulfide sensors from Hach. Whether in water or air, you will have the direct H2S measurement you need to optimize your H2S treatment process and proactively control H2S before it causes issues.

Catalog No. Product Net Price
LXV404.99.03512 SC200 Controller, 100-240 VAC, one digital sensor input, one analog pH/ORP/DO sensor input, Profibus DP, 4-20 mA outputs Special offer 
Add to Cart
  • Analog Output Functional Mode
  • Linear, logarithmic, bi-linear, PID
  • Communication Capabilities
  • Profibus DP
  • Conduit Openings
  • 1/2" NPT Conduit
  • Display
  • Graphic dot matrix LCD with LED backlighting, transreflective
  • Enclosure Rating
  • IP66 / NEMA 4X
  • Length
  • 181 mm
  • Material Enclosures
  • PolycarbonateAluminium (powder coated)Stainless steel
  • Operating Temperature Range
  • -20 - 60 °C at 0 - 95% RH (non-condensing)
  • Power Requirements (Voltage)
  • 100 - 240 VAC
  • Power Supply
  • Without power cord
  • Relays
  • Four electromechanical SPDT (Form C) contacts, 1200 W, 5 A
  • Sensor Input #1
  • Digital
  • Sensor Input #2
  • Analog pH/ORP/DO
  • Storage Conditions
  • -20 °C to 70 °C
  • Warranty
  • 24 months
  • Weight
  • 1.70 kg
  • What's included?
  • Controller, Mounting Hardware, Basic User Manual
LXV404.99.05102 SC200 Universal Controller: 100-240 V AC with one analog pH/ORP/DO sensor input, HART and two 4-20mA outputs Special offer 
Add to Cart
  • Analog Output Functional Mode
  • Linear, logarithmic, bi-linear, PID
  • Communication Capabilities
  • HART
  • Conduit Openings
  • 1/2" NPT Conduit
  • Display
  • Graphic dot matrix LCD with LED backlighting, transreflective
  • Enclosure Rating
  • IP66 / NEMA 4X
  • Length
  • 181 mm
  • Material Enclosures
  • PolycarbonateAluminium (powder coated)Stainless steel
  • Operating Temperature Range
  • -20 - 60 °C at 0 - 95% RH (non-condensing)
  • Power Requirements (Voltage)
  • 100 - 240 VAC
  • Power Supply
  • Without power cord
  • Relays
  • Four electromechanical SPDT (Form C) contacts, 1200 W, 5 A
  • Sensor Input #1
  • Analog pH/ORP/DO
  • Sensor Input #2
  • None
  • Storage Conditions
  • -20 °C to 70 °C
  • Warranty
  • 24 months
  • Weight
  • 1.70 kg
  • What's included?
  • Controller, Mounting Hardware, Basic User Manual
410K/P1C00000 Orbisphere 410K Controller, 1 Channel, LDO Luminescent Dissolved Oxygen (O₂), panel mount, 100-240 VAC, 4-20 mA, RS485 Special offer 
Add to Cart
  • Communication Capabilities
  • 3 x 0/4-20 mA; RS485; Ethernet
  • Compatible Instruments
  • Channel 1: K1100
  • Compliance Certifications
  • EMC: EN61326-1:2006CE: EN61010-1:2010ETL, conforming to UL 61010-1 and CSA 22.2 No. 61010-1
  • Controller
  • 410, Mono-channel
  • Display
  • Color TFT touchscreen display
  • Material
  • Aluminum
  • Measurements
  • Resolution, accuracy and response time are determined by sensor
  • Mounting
  • Panel
  • Operating Temperature Range
  • -5 - 50 °C
  • Parameter
  • Oxygen LDO sensor K1100 (power and steam)
  • Power Requirements (Voltage)
  • 100 - 240 VAC
  • Relays
  • 3 measurement alarm relays (2A to 30 VAC or 0.5 A to 50 VDC); configurable to send diagnostics information1 system alarm relay (2 A to 30 VAC or 0.5 A to 50 VDC)
  • User Interface
  • Touch screen panel displays: concentration, trend graph, diagnostics, alarm status, historical data
  • Warranty
  • 12 months
  • Weight
  • 3.35 kg
  • What's included?
  • 410 controller and manual only.K1100 sensor and cable, flow-chamber or process connection, must be ordered separately.
410M/P1C00000 Orbisphere 410M Controller O₂ (LDO), Panel Mount, 100-240 VAC, 0/4-20mA, RS485 Special offer 
Add to Cart
  • Communication Capabilities
  • 3 x 0/4-20 mA; RS485; Ethernet
  • Compatible Instruments
  • Channel 1: M1100
  • Compliance Certifications
  • EMC: EN61326-1:2006CE: EN61010-1:2010ETL, conforming to UL 61010-1 and CSA 22.2 No. 61010-1
  • Controller
  • 410, Mono-channel
  • Display
  • Color TFT touchscreen display
  • Material
  • Aluminum
  • Measurements
  • Resolution, accuracy and response time are determined by sensor
  • Mounting
  • Panel
  • Operating Temperature Range
  • -5 - 50 °C
  • Parameter
  • Oxygen LDO M1100 (beverage)
  • Power Requirements (Voltage)
  • 100 - 240 VAC
  • Relays
  • 3 measurement alarm relays (2A to 30 VAC or 0.5 A to 50 VDC); configurable to send diagnostics information1 system alarm relay (2 A to 30 VAC or 0.5 A to 50 VDC)
  • User Interface
  • Touch-screen panel displays: concentration, trend graph, diagnostics, alarm status, historical data
  • Warranty
  • 12 months
  • Weight
  • 3.35 kg
  • What's included?
  • 410 controller and manual only.M1100 sensor and cable, flow-chamber or process connection, must be ordered separately.
410A/W1C00000 Orbisphere 410A Controller O₂ (EC), 1 Channel, Wall Mount, 100-240 VAC, 4-20mA, RS485 Special offer 
Add to Cart
  • Communication Capabilities
  • 3 x 0/4-20 mA; RS485; Ethernet
  • Compatible Instruments
  • Channel 1: 311xx, A1100 or GA2x00
  • Compliance Certifications
  • EMC: EN61326-1:2006CE: EN61010-1:2010ETL, conforming to UL 61010-1 and CSA 22.2 No. 61010-1
  • Controller
  • 410, Mono-channel
  • Display
  • Color TFT touchscreen display
  • Material
  • Stainless steel
  • Measurements
  • Resolution, accuracy and response time are determined by sensor
  • Mounting
  • Wall
  • Operating Temperature Range
  • -5 - 50 °C
  • Parameter
  • O₂ (EC)
  • Power Requirements (Voltage)
  • 100 - 240 VAC
  • Relays
  • 3 measurement alarm relays (2A to 30 VAC or 0.5 A to 50 VDC); configurable to send diagnostics information1 system alarm relay (2 A to 30 VAC or 0.5 A to 50 VDC)
  • User Interface
  • Touch screen panel displays: concentration, trend graph, diagnostics, alarm status, historical data
  • Warranty
  • 12 months
  • Weight
  • 4.25 kg
  • What's included?
  • 410 controller and manual only.Sensor and cable, flow-chamber or process connection, must be ordered separately.
410C/P2C00000 Orbisphere 410 Controller O₃ (EC), Panel Mount, 10-30 VDC, 0/4-20mA Special offer 
Add to Cart
  • Communication Capabilities
  • 3 x 0/4-20 mA; RS485; Ethernet
  • Compatible Instruments
  • Channel 1 : 313xx or C1100
  • Compliance Certifications
  • EMC: EN61326-1:2006CE: EN61010-1:2010ETL, conforming to UL 61010-1 and CSA 22.2 No. 61010-1
  • Controller
  • 410, Mono-channel
  • Display
  • Colour TFT touchscreen display
  • Material
  • Aluminium
  • Measurements
  • Resolution, accuracy and response time are determined by sensor
  • Operating Temperature Range
  • -5 - 50 °C
  • Parameter
  • O₃ (EC)
  • Power Requirements (Voltage)
  • 10 - 30 V DC
  • Relays
  • 3 measurement alarm relays (2A to 30 VAC or 0.5 A to 50 VDC); configurable to send diagnostics information1 system alarm relay (2 A to 30 VAC or 0.5 A to 50 VDC)
  • User Interface
  • Touch screen panel displays: concentration, trend graph, diagnostics, alarm status, historical data
  • Warranty
  • 12 months
  • Weight
  • 2.9 kg
  • What's included?
  • 410 controller and manual only.Sensor and cable, flow-chamber or process connection, must be ordered separately.
LXV525.99A11601 SC4500 Controller, Prognosys, mA Output, 1 Ultrapure Water Conductivity, 100-240 VAC, without power cord Special offer 
Add to Cart
  • Altitude
  • 3000 m (9842 ft) maximum
  • Analog Output Functional Mode
  • Linear, PID
  • Communication (optional)
  • Analog:Five 0-20 mA or 4-20 mA analog outputs on each analog output moduleUp to two analog Input modules (0-20 mA or 4-20 mA). Each input module replaces a digital sensor input.Digital:Profibus DPV1 moduleModbus TCPProfinet IO moduleEthernet IP module
  • Compatible Instruments
  • Compatible Sensors and Analyzers / Software Version (Release Year)Amtax sc / V2.30 (2018) or higherA-ISE sc / V1.02 or higherAN-ISE sc / V1.08 (2013) or higherN-ISE sc / V1.02 or higherNitratax clear sc, Nitratax eco sc, Nitratax plus sc / V3.13 (2013) or higherNT3100sc/NT3200scPhosphax sc / V2.30 (2018) or higherPhosphax sc LR/MR/HR / V1.01 (2018) or higherTSS sc / V41.73 (2013) or higherSolitax sc / V2.20 (2013) or higherTU5300sc, TU5400sc / V1.34 (2017) or higherSS7 sc (in Bypass) / V1.06 (2006) or higherUltraturb sc / V3.06 (2017) or higher1720E / V2.10 (2006) or higherSonatax sc / V1.15 (2016) or higherCL17sc / V2.7 (2019) or higherCL10sc / V1.14 (2013) or higher9184sc, 9185sc, 9187sc* / V2.03 (2013) or higherUvas plus sc / V3.01 (2017) or higherLDO 2 sc* / V1.22 (2013) or higher3798sc* / V2.03 (2013) or higher3700sc + Inductive Conductive Digital Gateway 6120800 / V3.00 (2017) or higher3422sc, Analog 3400 + Contacting Cond. Digital Gateway 6120700 / V3.00 or higherpHD sc*, pHD-S sc / V3.10 (2016) or higher1200-S sc* / V2.04 (2013) or higher pHD analog + Digital Gateway 6120500 / V3.00 (2017) or higherRC and PC analog sensor + Digital Gateway for conventional analog pH and ORP sensors 6120600 / V3.00 (2017) or higher 8362sc* / V3.00 (2017) or higher*Hardware Version1 of instrument is not supported
  • Compatible Network Technologies
  • GSM 3G/4G (e.g. AT&T, T-Mobile, Rogers, Vodafone etc.)CDMA (e.g. Verizon)
  • Compliance Certifications
  • CE. ETL certified to UL and CSA safety standards (with all sensor types), FCC, ISED, KC, RCM, EAC, UKCA, SABS, C م (Morocco)
  • Conduit Openings
  • ½" NPT conduit
  • Dimensions
  • ½ DIN - 144 x 144 x 192 mm (5.7 x 5.7 x 7.6 in.)
  • Display
  • 3.5-inch TFT colour display with capacitive touchpad
  • Enclosure Rating
  • UL50E type 4X, IEC/EN 60529–IP 66, NEMA 250 type 4XMetal enclosure with a corrosion-resistant finish
  • Indoor/Outdoor
  • Outdoor installation in direct sunlight or UV radiation requires UV protection screen and/or sunroof
  • Installation Category
  • Category II
  • Material Enclosures
  • Polycarbonate, aluminum (powder coated), stainless steel
  • Measurements
  • One analog device connector
  • Mounting
  • Wall, Pole, or Panel Mounting
  • Network Connectivity
  • LAN: Two Ethernet connectors (10/100 Mbps)Cellular: External 4GWi-Fi
  • Operating Temperature Range
  • -20 to 60 °C (-4 to 140 °F) (8 W (AC)/9 W (DC) sensor load)-20 to 45 °C (-4 to 113 °F) (28 W (AC)/20 W (DC) sensor load) Linear derating between 45 and 60 °C (-1.33 W/°C)
  • Outputs
  • 5x mA Output
  • Pollution Degree
  • 4
  • Power Requirements (Voltage)
  • 100-240 VAC ±10%, 50/60 Hz; 1 A
  • Power Supply
  • No Plug
  • Protection Class
  • I, connected to protective earth
  • Relays
  • Two relays (SPDT);Wire gauge: 0.75 to 1.5 mm² (18 to 16 AWG)AC controllerMaximum switching voltage: 100 - 240 VACMaximum switching current: 5 A Resistive/1 A Pilot DutyMaximum switching power: 1200 VA Resistive/360 VA Pilot DutyDC controllerMaximum switching voltage: 30 VAC or 42 VDCMaximum switching current: 4 A Resistive/1 A Pilot DutyMaximum switching power: 125 W Resistive/28 W Pilot Duty
  • Sensor Input #1
  • Analog UPW Conductivity
  • Sensor Input #2
  • None
  • Software available
  • Non-Claros + Embedded Prognosys
  • Storage Conditions
  • -20 - 70 °C (-4 - 158 °F), 0 - 95% relative humidity, non-condensing
  • USB Port
  • Used for data download and software upload. The controller records approximately 20,000 data points for each connected sensor.
  • Warranty
  • 12 months
  • Weight
  • 3.7 lb (controller only, w/o modules)
  • What's included?
  • SC4500 Controller, Non-Claros + Embedded Prognosys, mA Output, 1 Ultrapure Water Conductivity, without power cord; includes mounting hardware
LXV525.99A12601 SC4500 Controller, Prognosys, Profibus DP, 1 Ultrapure Water Conductivity, 100-240 VAC, without power cord Special offer 
Add to Cart
  • Altitude
  • 3000 m (9842 ft) maximum
  • Analog Output Functional Mode
  • Linear, PID
  • Communication (optional)
  • Analog:Five 0-20 mA or 4-20 mA analog outputs on each analog output moduleUp to two analog Input modules (0-20 mA or 4-20 mA). Each input module replaces a digital sensor input.Digital:Profibus DPV1 moduleModbus TCPProfinet IO moduleEthernet IP module
  • Compatible Instruments
  • Compatible Sensors and Analyzers / Software Version (Release Year)Amtax sc / V2.30 (2018) or higherA-ISE sc / V1.02 or higherAN-ISE sc / V1.08 (2013) or higherN-ISE sc / V1.02 or higherNitratax clear sc, Nitratax eco sc, Nitratax plus sc / V3.13 (2013) or higherNT3100sc/NT3200scPhosphax sc / V2.30 (2018) or higherPhosphax sc LR/MR/HR / V1.01 (2018) or higherTSS sc / V41.73 (2013) or higherSolitax sc / V2.20 (2013) or higherTU5300sc, TU5400sc / V1.34 (2017) or higherSS7 sc (in Bypass) / V1.06 (2006) or higherUltraturb sc / V3.06 (2017) or higher1720E / V2.10 (2006) or higherSonatax sc / V1.15 (2016) or higherCL17sc / V2.7 (2019) or higherCL10sc / V1.14 (2013) or higher9184sc, 9185sc, 9187sc* / V2.03 (2013) or higherUvas plus sc / V3.01 (2017) or higherLDO 2 sc* / V1.22 (2013) or higher3798sc* / V2.03 (2013) or higher3700sc + Inductive Conductive Digital Gateway 6120800 / V3.00 (2017) or higher3422sc, Analog 3400 + Contacting Cond. Digital Gateway 6120700 / V3.00 or higherpHD sc*, pHD-S sc / V3.10 (2016) or higher1200-S sc* / V2.04 (2013) or higher pHD analog + Digital Gateway 6120500 / V3.00 (2017) or higherRC and PC analog sensor + Digital Gateway for conventional analog pH and ORP sensors 6120600 / V3.00 (2017) or higher 8362sc* / V3.00 (2017) or higher*Hardware Version1 of instrument is not supported
  • Compatible Network Technologies
  • GSM 3G/4G (e.g. AT&T, T-Mobile, Rogers, Vodafone etc.)CDMA (e.g. Verizon)
  • Compliance Certifications
  • CE. ETL certified to UL and CSA safety standards (with all sensor types), FCC, ISED, KC, RCM, EAC, UKCA, SABS, C م (Morocco)
  • Conduit Openings
  • ½" NPT conduit
  • Dimensions
  • ½ DIN - 144 x 144 x 192 mm (5.7 x 5.7 x 7.6 in.)
  • Display
  • 3.5-inch TFT colour display with capacitive touchpad
  • Enclosure Rating
  • UL50E type 4X, IEC/EN 60529–IP 66, NEMA 250 type 4XMetal enclosure with a corrosion-resistant finish
  • Indoor/Outdoor
  • Outdoor installation in direct sunlight or UV radiation requires UV protection screen and/or sunroof
  • Installation Category
  • Category II
  • Material Enclosures
  • Polycarbonate, aluminum (powder coated), stainless steel
  • Measurements
  • One analog device connector
  • Mounting
  • Wall, Pole, or Panel Mounting
  • Network Connectivity
  • LAN: Two Ethernet connectors (10/100 Mbps)Cellular: External 4GWi-Fi
  • Operating Temperature Range
  • -20 to 60 °C (-4 to 140 °F) (8 W (AC)/9 W (DC) sensor load)-20 to 45 °C (-4 to 113 °F) (28 W (AC)/20 W (DC) sensor load) Linear derating between 45 and 60 °C (-1.33 W/°C)
  • Outputs
  • Profibus DP
  • Pollution Degree
  • 4
  • Power Requirements (Voltage)
  • 100-240 VAC ±10%, 50/60 Hz; 1 A
  • Power Supply
  • No Plug
  • Protection Class
  • I, connected to protective earth
  • Relays
  • Two relays (SPDT);Wire gauge: 0.75 to 1.5 mm² (18 to 16 AWG)AC controllerMaximum switching voltage: 100 - 240 VACMaximum switching current: 5 A Resistive/1 A Pilot DutyMaximum switching power: 1200 VA Resistive/360 VA Pilot DutyDC controllerMaximum switching voltage: 30 VAC or 42 VDCMaximum switching current: 4 A Resistive/1 A Pilot DutyMaximum switching power: 125 W Resistive/28 W Pilot Duty
  • Sensor Input #1
  • Analog UPW Conductivity
  • Sensor Input #2
  • None
  • Software available
  • Non-Claros + Embedded Prognosys
  • Storage Conditions
  • -20 - 70 °C (-4 - 158 °F), 0 - 95% relative humidity, non-condensing
  • USB Port
  • Used for data download and software upload. The controller records approximately 20,000 data points for each connected sensor.
  • Warranty
  • 12 months
  • Weight
  • 3.7 lb (controller only, w/o modules)
  • What's included?
  • SC4500 Controller, Non-Claros + Embedded Prognosys, Profibus DP, 1 Ultrapure Water Conductivity, without power cord; includes mounting hardware
LXV525.99A1B541 SC4500 Controller, Prognosys, LAN + mA Output, 1 digital Sensor, 1 mA Input, 100-240 VAC, without power cord Special offer 
Add to Cart
  • Altitude
  • 3000 m (9842 ft) maximum
  • Analog Output Functional Mode
  • Linear, PID
  • Communication (optional)
  • Analog:Five 0-20 mA or 4-20 mA analog outputs on each analog output moduleUp to two analog Input modules (0-20 mA or 4-20 mA). Each input module replaces a digital sensor input.Digital:Profibus DPV1 moduleModbus TCPProfinet IO moduleEthernet IP module
  • Compatible Instruments
  • Compatible Sensors and Analyzers / Software Version (Release Year)Amtax sc / V2.30 (2018) or higherA-ISE sc / V1.02 or higherAN-ISE sc / V1.08 (2013) or higherN-ISE sc / V1.02 or higherNitratax clear sc, Nitratax eco sc, Nitratax plus sc / V3.13 (2013) or higherNT3100sc/NT3200scPhosphax sc / V2.30 (2018) or higherPhosphax sc LR/MR/HR / V1.01 (2018) or higherTSS sc / V41.73 (2013) or higherSolitax sc / V2.20 (2013) or higherTU5300sc, TU5400sc / V1.34 (2017) or higherSS7 sc (in Bypass) / V1.06 (2006) or higherUltraturb sc / V3.06 (2017) or higher1720E / V2.10 (2006) or higherSonatax sc / V1.15 (2016) or higherCL17sc / V2.7 (2019) or higherCL10sc / V1.14 (2013) or higher9184sc, 9185sc, 9187sc* / V2.03 (2013) or higherUvas plus sc / V3.01 (2017) or higherLDO 2 sc* / V1.22 (2013) or higher3798sc* / V2.03 (2013) or higher3700sc + Inductive Conductive Digital Gateway 6120800 / V3.00 (2017) or higher3422sc, Analog 3400 + Contacting Cond. Digital Gateway 6120700 / V3.00 or higherpHD sc*, pHD-S sc / V3.10 (2016) or higher1200-S sc* / V2.04 (2013) or higher pHD analog + Digital Gateway 6120500 / V3.00 (2017) or higherRC and PC analog sensor + Digital Gateway for conventional analog pH and ORP sensors 6120600 / V3.00 (2017) or higher 8362sc* / V3.00 (2017) or higher*Hardware Version1 of instrument is not supported
  • Compatible Network Technologies
  • GSM 3G/4G (e.g. AT&T, T-Mobile, Rogers, Vodafone etc.)CDMA (e.g. Verizon)
  • Compliance Certifications
  • CE. ETL certified to UL and CSA safety standards (with all sensor types), FCC, ISED, KC, RCM, EAC, UKCA, SABS, C م (Morocco)
  • Conduit Openings
  • ½" NPT conduit
  • Dimensions
  • ½ DIN - 144 x 144 x 192 mm (5.7 x 5.7 x 7.6 in.)
  • Display
  • 3.5-inch TFT colour display with capacitive touchpad
  • Enclosure Rating
  • UL50E type 4X, IEC/EN 60529–IP 66, NEMA 250 type 4XMetal enclosure with a corrosion-resistant finish
  • Indoor/Outdoor
  • Outdoor installation in direct sunlight or UV radiation requires UV protection screen and/or sunroof
  • Installation Category
  • Category II
  • Material Enclosures
  • Polycarbonate, aluminum (powder coated), stainless steel
  • Measurements
  • Two device digital SC connectors
  • Mounting
  • Wall, Pole, or Panel Mounting
  • Network Connectivity
  • LAN: Two Ethernet connectors (10/100 Mbps)Cellular: External 4GWi-Fi
  • Operating Temperature Range
  • -20 to 60 °C (-4 to 140 °F) (8 W (AC)/9 W (DC) sensor load)-20 to 45 °C (-4 to 113 °F) (28 W (AC)/20 W (DC) sensor load) Linear derating between 45 and 60 °C (-1.33 W/°C)
  • Outputs
  • LAN + mA Output
  • Pollution Degree
  • 4
  • Power Requirements (Voltage)
  • 100-240 VAC ±10%, 50/60 Hz; 1 A
  • Power Supply
  • Without power cord
  • Protection Class
  • I, connected to protective earth
  • Relays
  • Two relays (SPDT);Wire gauge: 0.75 to 1.5 mm² (18 to 16 AWG)Maximum switching voltage: 100 - 240 VACMaximum switching current: 5 A Resistive/1 A Pilot DutyMaximum switching power: 1200 VA Resistive/360 VA Pilot Duty
  • Sensor Input #1
  • Digital
  • Sensor Input #2
  • mA Input
  • Software available
  • Non-Claros + Embedded Prognosys
  • Storage Conditions
  • -20 - 70 °C (-4 - 158 °F), 0 - 95% relative humidity, non-condensing
  • USB Port
  • Used for data download and software upload. The controller records approximately 20,000 data points for each connected sensor.
  • Warranty
  • 12 months
  • Weight
  • 3.7 lb (controller only, w/o modules)
  • What's included?
  • SC4500 Controller, Non-Claros + Embedded Prognosys, without power cord; includes mounting hardware
LXV525.99A1B661 SC4500 Controller, Prognosys, LAN + mA Output, 2 Ultrapure Water Conductivity, 100-240 VAC, without power cord Special offer 
Add to Cart
  • Altitude
  • 3000 m (9842 ft) maximum
  • Analog Output Functional Mode
  • Linear, PID
  • Communication (optional)
  • Analog:Five 0-20 mA or 4-20 mA analog outputs on each analog output moduleUp to two analog Input modules (0-20 mA or 4-20 mA). Each input module replaces a digital sensor input.Digital:Profibus DPV1 moduleModbus TCPProfinet IO moduleEthernet IP module
  • Compatible Instruments
  • Compatible Sensors and Analyzers / Software Version (Release Year)Amtax sc / V2.30 (2018) or higherA-ISE sc / V1.02 or higherAN-ISE sc / V1.08 (2013) or higherN-ISE sc / V1.02 or higherNitratax clear sc, Nitratax eco sc, Nitratax plus sc / V3.13 (2013) or higherNT3100sc/NT3200scPhosphax sc / V2.30 (2018) or higherPhosphax sc LR/MR/HR / V1.01 (2018) or higherTSS sc / V41.73 (2013) or higherSolitax sc / V2.20 (2013) or higherTU5300sc, TU5400sc / V1.34 (2017) or higherSS7 sc (in Bypass) / V1.06 (2006) or higherUltraturb sc / V3.06 (2017) or higher1720E / V2.10 (2006) or higherSonatax sc / V1.15 (2016) or higherCL17sc / V2.7 (2019) or higherCL10sc / V1.14 (2013) or higher9184sc, 9185sc, 9187sc* / V2.03 (2013) or higherUvas plus sc / V3.01 (2017) or higherLDO 2 sc* / V1.22 (2013) or higher3798sc* / V2.03 (2013) or higher3700sc + Inductive Conductive Digital Gateway 6120800 / V3.00 (2017) or higher3422sc, Analog 3400 + Contacting Cond. Digital Gateway 6120700 / V3.00 or higherpHD sc*, pHD-S sc / V3.10 (2016) or higher1200-S sc* / V2.04 (2013) or higher pHD analog + Digital Gateway 6120500 / V3.00 (2017) or higherRC and PC analog sensor + Digital Gateway for conventional analog pH and ORP sensors 6120600 / V3.00 (2017) or higher 8362sc* / V3.00 (2017) or higher*Hardware Version1 of instrument is not supported
  • Compatible Network Technologies
  • GSM 3G/4G (e.g. AT&T, T-Mobile, Rogers, Vodafone etc.)CDMA (e.g. Verizon)
  • Compliance Certifications
  • CE. ETL certified to UL and CSA safety standards (with all sensor types), FCC, ISED, KC, RCM, EAC, UKCA, SABS, C م (Morocco)
  • Conduit Openings
  • ½" NPT conduit
  • Dimensions
  • ½ DIN - 144 x 144 x 192 mm (5.7 x 5.7 x 7.6 in.)
  • Display
  • 3.5-inch TFT colour display with capacitive touchpad
  • Enclosure Rating
  • UL50E type 4X, IEC/EN 60529–IP 66, NEMA 250 type 4XMetal enclosure with a corrosion-resistant finish
  • Indoor/Outdoor
  • Outdoor installation in direct sunlight or UV radiation requires UV protection screen and/or sunroof
  • Installation Category
  • Category II
  • Material Enclosures
  • Polycarbonate, aluminum (powder coated), stainless steel
  • Measurements
  • Two analog device connectors
  • Mounting
  • Wall, Pole, or Panel Mounting
  • Network Connectivity
  • LAN: Two Ethernet connectors (10/100 Mbps)Cellular: External 4GWi-Fi
  • Operating Temperature Range
  • -20 to 60 °C (-4 to 140 °F) (8 W (AC)/9 W (DC) sensor load)-20 to 45 °C (-4 to 113 °F) (28 W (AC)/20 W (DC) sensor load) Linear derating between 45 and 60 °C (-1.33 W/°C)
  • Outputs
  • LAN + 5x mA Output
  • Pollution Degree
  • 4
  • Power Requirements (Voltage)
  • 100-240 VAC ±10%, 50/60 Hz; 1 A
  • Power Supply
  • No Plug
  • Protection Class
  • I, connected to protective earth
  • Relays
  • Two relays (SPDT);Wire gauge: 0.75 to 1.5 mm² (18 to 16 AWG)AC controllerMaximum switching voltage: 100 - 240 VACMaximum switching current: 5 A Resistive/1 A Pilot DutyMaximum switching power: 1200 VA Resistive/360 VA Pilot DutyDC controllerMaximum switching voltage: 30 VAC or 42 VDCMaximum switching current: 4 A Resistive/1 A Pilot DutyMaximum switching power: 125 W Resistive/28 W Pilot Duty
  • Sensor Input #1
  • Analog UPW Conductivity
  • Sensor Input #2
  • Analog UPW Conductivity
  • Software available
  • Non-Claros + Embedded Prognosys
  • Storage Conditions
  • -20 - 70 °C (-4 - 158 °F), 0 - 95% relative humidity, non-condensing
  • USB Port
  • Used for data download and software upload. The controller records approximately 20,000 data points for each connected sensor.
  • Warranty
  • 12 months
  • Weight
  • 3.7 lb (controller only, w/o modules)
  • What's included?
  • SC4500 Controller, Non-Claros + Embedded Prognosys, LAN + mA Output, 2 Ultrapure Water Conductivity, without power cord; includes mounting hardware

Related Categories