+852-3069 6950
css@gugent.com.hk
 

We have developed a unique portfolio of consumables, each adapted to the different feed water quality requirements and to your various applications. To maintain your water system’s performance, it’s critical to replace your purification cartridges on time and with genuine ISO 9001-certified parts.

Catalog No. Product Net Price
KHVEG2TTT1H Gamma Compatible High Area Opticap® XLT 20 Millipore Express® SHR with prefilter 0.5 µm/0.1 µm 1-1/2 in. TC 1604 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Bacterial Retention
  • Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
  • Cartridge Nominal Length
  • 20 in (50 cm)
  • Catalogue Number
  • KHVEG2TTT1H
  • Chemistry
  • Hydrophilic Polyethersulfone (PES)
  • Device Configuration
  • Capsule
  • Device Material
  • Gamma Stable Polypropylene/Polysulfone
  • Device Size
  • 20 in.
  • Diameter
  • 10.7 cm (4.2 in)
  • European Pressure Equipment Directive
  • EMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
  • Filtration Area
  • 20000 cm²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Housing Material
  • Polypropylene (PP)
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Sanitary Flange
  • Inlet Connection Diameter
  • 1.5 in
  • Inlet to Outlet Width
  • 15.2 cm (6.0 in)
  • Key Applications
  • Laboratory Filtration
  • Length
  • 20 in (50 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • Forward: 6.9 (100) intermittent @ 25 °C; 5.5 (80) @ 25 °C; 1.0 (15) @ 80 °C. Reverse: 2.1 (30) @ 25 °C, intermittent
  • Maximum Inlet Pressure (psig)
  • 80
  • Maximum Inlet Pressure, bar (psi)
  • 6.9 (100) intermittent @ 25 °C; 5.5 (80) @ 25 °C; 2.75 (40) @ 60 °C; 1.0 (15) @ 80 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Non-Fiber Releasing
  • This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Outlet Connection
  • Sanitary Flange
  • Outlet Connection Diameter
  • 1.5 in
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥4 L
  • Pore Size
  • 0.5 / 0.1 µm
  • Seal Material
  • Silicone (SI)
  • Sterility
  • Non-Sterile
  • Sterilization
  • Gamma compatible to 45 kGy; 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
  • Support Material
  • Polyester
  • Trade Name
  • Millipore Express®
  • Vent Cap Material
  • Gamma stable polypropylene (PP)
  • Wettability
  • Hydrophilic
  • Width
  • 15.2 cm (6.0 in)
CN0372E06 Polygard-CN Cartridge Filter 20 in. 0.3 µm Code 7 Ethylene-Propylene 1618 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 7 (2-226) O-rings w/locking-tabs
  • Cartridge Nominal Length
  • 20 in. (50 cm)
  • Catalogue Number
  • CN0372E06
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Filtration Area
  • 0.84 m²
  • Gravimetric Extractables
  • ≤100 mg after 24-h soak in water
  • Length
  • 20 in. (50 cm)
  • Material Size
  • 6
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 0.3 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥10 L
  • Pore Size
  • 0.3 µm
  • Sanitization
  • 30 min with hot water @ 80 °C
  • Seal Material
  • Ethylene Propylene
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Polygard®
  • Wettability
  • Hydrophilic
CN0372E06 Polygard-CN Cartridge Filter 20 in. 0.3 µm Code 7 Ethylene-Propylene 1618 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 7 (2-226) O-rings w/locking-tabs
  • Cartridge Nominal Length
  • 20 in. (50 cm)
  • Catalogue Number
  • CN0372E06
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Filtration Area
  • 0.84 m²
  • Gravimetric Extractables
  • ≤100 mg after 24-h soak in water
  • Length
  • 20 in. (50 cm)
  • Material Size
  • 6
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 0.3 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥10 L
  • Pore Size
  • 0.3 µm
  • Sanitization
  • 30 min with hot water @ 80 °C
  • Seal Material
  • Ethylene Propylene
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Polygard®
  • Wettability
  • Hydrophilic
KVGLG3TBB1 Opticap® Gamma Compatible XLT30 Durapore® 0.22 µm 1 in. HB/HB 1643 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Bacterial Retention
  • Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • KVGLG3TBB1
  • Chemistry
  • Polyvinylidene Fluoride (PVDF)
  • Device Configuration
  • Capsule
  • Device Material
  • Gamma-stable polypropylene
  • Device Size
  • 30 in.
  • Diameter
  • 10.7 cm (4.2 in.)
  • Filtration Area
  • 2.17 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 75 mg per capsule after 24 hours in water at controlled room temperature.
  • Housing Material
  • Polypropylene (PP)
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Hose Barb
  • Inlet Connection Diameter
  • 1 in.
  • Inlet to Outlet Width
  • 19.8 cm (7.8 in.)
  • Length
  • 30 in. (75 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • Forward: 5.5 bar (80 psid) @ 25 °C; 1.7 bar (25 psid) @ 80 °C. Reverse: 3.5 bar (50 psid) @ 25 °C, intermittent
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 23 °C; 2.8 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Durapore®
  • Non-Fiber Releasing
  • This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Outlet Connection
  • Hose Barb
  • Outlet Connection Diameter
  • 1 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥3 L
  • Pore Size
  • 0.22 µm
  • Seal Material
  • Silicone (SI)
  • Sterility
  • Gamma
  • Sterilization
  • 3 autoclave cycles of 60 min @ 126 °C; capable of 45 kilogray (4.5 Megarad) gamma exposure; not in-line steam sterilizable
  • Support Material
  • Polyester
  • Trade Name
  • Opticap®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Polypropylene (PP)
  • Wettability
  • Hydrophilic
  • Width
  • 19.8 cm (7.8 in.)
CRK304V06 Polygard-CR Cartridge Filter 40 in. 0.3 µm Code 0 Fluoroelastomer 1652 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 0 (2-222) O-rings
  • Cartridge Nominal Length
  • 40 in. (100 cm)
  • Catalogue Number
  • CRK304V06
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Gravimetric Extractables
  • ≤50 mg after 24-h soak in water
  • Length
  • 40 in. (100 cm)
  • Material Size
  • 6
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 0.3 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥20 L
  • Pore Size
  • 0.3 µm
  • Sanitization
  • 30 min with hot water @ 80 °C
  • Seal Material
  • Fluorocarbon rubber
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Polygard®
  • Wettability
  • Hydrophilic
CRK354V06 Polygard-CR Cartridge Filter 40 in. 0.3 µm Code 5 Fluoroelastomer 1652 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 5 (2-222) O-rings and spear
  • Cartridge Nominal Length
  • 40 in. (100 cm)
  • Catalogue Number
  • CRK354V06
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Gravimetric Extractables
  • ≤50 mg after 24-h soak in water
  • Length
  • 40 in. (100 cm)
  • Material Size
  • 6
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 0.3 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥20 L
  • Pore Size
  • 0.3 µm
  • Sanitization
  • 30 min with hot water @ 80 °C
  • Seal Material
  • Fluorocarbon rubber
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Polygard®
  • Wettability
  • Hydrophilic
PSDVAG101 Prostak™ MF Module 0.65 µm 10 stack 0.84 m2 1652 
Add to Cart
  • Catalogue Number
  • PSDVAG101
  • Chemistry
  • Polyvinylidene Fluoride (PVDF)
  • Device Configuration
  • Module
  • Device Size
  • 10 stack
  • Filter Code
  • DVPP
  • Filter Type
  • Microfiltration
  • Filtration Area
  • 0.84 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Height
  • 8.1 cm (3.2 in.)
  • Key Applications
  • Concentration and Clarification of cellsPerfusion
  • Length
  • 38.9 cm (15.3 in.)
  • Material Size
  • 1
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 50 °C4.1 bar (60 psi) @ 50-80 °C
  • Maximum Transmembrane Pressure
  • 4.1 bar (60 psi) @ 50 °C2.1 bar (30 psi) @ 50-80 °C
  • Media
  • Durapore®
  • Membrane Area
  • 0.84 m²
  • pH Range
  • pH2 – pH10 ContinuouspH1 – pH11 Short Duration
  • Pore Size
  • 0.65 µm
  • Screen Type
  • Type V screen (open channel)
  • Seal Material
  • Module supplied with Silicone (SI) gaskets
  • Trade Name
  • Prostak
  • Wettability
  • Hydrophilic
  • Width
  • 19.8 cm (7.8 in.)
PSDVAG101 Prostak™ MF Module 0.65 µm 10 stack 0.84 m2 1652 
Add to Cart
  • Catalogue Number
  • PSDVAG101
  • Chemistry
  • Polyvinylidene Fluoride (PVDF)
  • Device Configuration
  • Module
  • Device Size
  • 10 stack
  • Filter Code
  • DVPP
  • Filter Type
  • Microfiltration
  • Filtration Area
  • 0.84 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Height
  • 8.1 cm (3.2 in.)
  • Key Applications
  • Concentration and Clarification of cellsPerfusion
  • Length
  • 38.9 cm (15.3 in.)
  • Material Size
  • 1
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 50 °C4.1 bar (60 psi) @ 50-80 °C
  • Maximum Transmembrane Pressure
  • 4.1 bar (60 psi) @ 50 °C2.1 bar (30 psi) @ 50-80 °C
  • Media
  • Durapore®
  • Membrane Area
  • 0.84 m²
  • pH Range
  • pH2 – pH10 ContinuouspH1 – pH11 Short Duration
  • Pore Size
  • 0.65 µm
  • Screen Type
  • Type V screen (open channel)
  • Seal Material
  • Module supplied with Silicone (SI) gaskets
  • Trade Name
  • Prostak
  • Wettability
  • Hydrophilic
  • Width
  • 19.8 cm (7.8 in.)
CN1H03E06 Polygard-CN Cartridge Filter 30 in. 10.0 µm Code 0 Ethylene-Propylene 1667 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 0 (2-222) O-rings
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • CN1H03E06
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Filtration Area
  • 1.26 m²
  • Gravimetric Extractables
  • ≤150 mg after 24-h soak in water
  • Length
  • 30 in. (75 cm)
  • Material Size
  • 6
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 10.0 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥15 L
  • Pore Size
  • 10.0 µm
  • Sanitization
  • 30 min with hot water @ 80 °C
  • Seal Material
  • Ethylene Propylene
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Polygard®
  • Wettability
  • Hydrophilic
CN1H03E06 Polygard-CN Cartridge Filter 30 in. 10.0 µm Code 0 Ethylene-Propylene 1667 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 0 (2-222) O-rings
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • CN1H03E06
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Filtration Area
  • 1.26 m²
  • Gravimetric Extractables
  • ≤150 mg after 24-h soak in water
  • Length
  • 30 in. (75 cm)
  • Material Size
  • 6
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 10.0 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥15 L
  • Pore Size
  • 10.0 µm
  • Sanitization
  • 30 min with hot water @ 80 °C
  • Seal Material
  • Ethylene Propylene
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Polygard®
  • Wettability
  • Hydrophilic

Overview

Analytical Sample Preparation Membrane Filtration Devices


Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.


Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.


Filter Membranes

Millex® Syringe Filters

Filtration Holders & Accessories



Resources