We have developed a unique portfolio of consumables, each adapted to the different feed water quality requirements and to your various applications. To maintain your water system’s performance, it’s critical to replace your purification cartridges on time and with genuine ISO 9001-certified parts.
Forward: 6.9 bar (100 psid) intermittent @ 25 °C; 5.5 bar (80 psid) @ 25 °C; 1.0 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C, intermittent
Maximum Inlet Pressure (psig)
80 psig
Maximum Inlet Pressure, bar (psi)
6.9 bar (100 psi) intermittent @ 23 °C; 5.5 bar (80 psi) @ 23 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
Maximum Inlet Temperature
25 °C
Media
Millipore Express® SHR
Non-Fiber Releasing
This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Outlet Connection
Hose Barb
Outlet Connection Diameter
5/8 in.
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥3 L
Pore Size
0.1 µm
Seal Material
Silicone (SI)
Sterilization
3 autoclave cycles of 60 min @ 126 °C; not in-line steam sterilizable
Support Material
Polypropylene
Trade Name
Millipore Express®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Forward: 6.9 bar (100 psid) intermittent @ 25 °C; 5.5 bar (80 psid) @ 25 °C; 1.0 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C, intermittent
Maximum Inlet Pressure (psig)
80 psig
Maximum Inlet Pressure, bar (psi)
6.9 bar (100 psi) intermittent @ 23 °C; 5.5 bar (80 psi) @ 23 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
Maximum Inlet Temperature
25 °C
Media
Millipore Express® SHR
Non-Fiber Releasing
This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Outlet Connection
Sanitary Flange
Outlet Connection Diameter
1-1/2 in.
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥3 L
Pore Size
0.1 µm
Seal Material
Silicone (SI)
Sterilization
3 autoclave cycles of 60 min @ 126 °C; not in-line steam sterilizable
Support Material
Polypropylene
Trade Name
Millipore Express®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Bacterial Retention
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
Cartridge Nominal Length
30 in. (75 cm)
Catalogue Number
KHGEA3STT1
Chemistry
Polyethersulfone (PES)
Device Configuration
Capsule
Device Material
Polypropylene/Polysulfone
Device Size
30 in.
Diameter
19.8 cm (7.8 in.)
Filtration Area
1.48 m²
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Housing Material
Polypropylene (PP)
Indirect Food Additive
All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
Inlet Connection
Sanitary Flange
Inlet Connection Diameter
1-1/2 in.
Length
30 in. (75 cm)
Material Package
Double Easy-Open bag
Material Size
1
Maximum Differential Pressure
Forward: 5500 mbar (80 psi) @ 25 °C; 1000 bar (15 psi) @ 80 °C; 6900 mbar (100 psi) @ 25 °C, intermittent. Reverse: 2100 bar (30 psi) @ 25 °C, intermittent
Maximum Inlet Pressure (psig)
80 psig
Maximum Inlet Pressure, bar (psi)
6.9 bar (100 psi) intermittent @ 25 °C; 5.5 bar (80 psi) @ 25 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
Maximum Inlet Temperature
25 °C
Media
Millipore Express® SHC
Non-Fiber Releasing
This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Outlet Connection
Sanitary Flange
Outlet Connection Diameter
1-1/2 in.
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥6 L
Pore Size
0.5 / 0.2 µm
Seal Material
Silicone (SI)
Sterilization
3 autoclave cycles of 60 min @ 126 °C; not in-line steam sterilizable
Support Material
Polypropylene
Trade Name
Millipore Express®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Bacterial Retention
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
Cartridge Nominal Length
30 in. (75 cm)
Catalogue Number
KVVLA3TTH1
Chemistry
Polyvinylidene Fluoride (PVDF)
Device Configuration
Capsule
Device Material
Polypropylene
Device Size
30 in.
Diameter
10.7 cm (4.2 in.)
Filtration Area
2.1 m²
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 75 mg per capsule after 24 hours in water at controlled room temperature.
Housing Material
Polypropylene (PP)
Indirect Food Additive
All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
Inlet Connection
Sanitary Flange
Inlet Connection Diameter
1-1/2 in.
Inlet to Outlet Width
17.5 cm (6.9 in.)
Length
30 in. (75 cm)
Material Package
Double Easy-Open bag
Material Size
1
Maximum Differential Pressure, bar (psid)
Forward: 5.5 bar (80 psid) @ 25 °C; 1.7 bar (25 psid) @ 80 °C. Reverse: 3.5 bar (50 psid) @ 25 °C, intermittent
Maximum Inlet Pressure (psig)
80 psig
Maximum Inlet Pressure, bar (psi)
5.5 bar (80 psi) @ 23 °C; 2.8 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
Maximum Inlet Temperature
25 °C
Media
Durapore®
Non-Fiber Releasing
This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Outlet Connection
Hose Barb
Outlet Connection Diameter
5/8 in.
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥3 L
Pore Size
0.1 µm
Seal Material
Silicone (SI)
Sterility
Other
Sterilization
3 autoclave cycles of 60 min @ 126 °C; not in-line steam sterilizable
Support Material
Polypropylene
Trade Name
Opticap®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Code
Code 7 (2-226) O-ring and spear
Cartridge Nominal Length
30 in. (75 cm)
Catalogue Number
CGW173S03
Chemistry
Mixed Cellulose Esters (MCE)
Device Configuration
Cartridge
Device Material
Polypropylene
Device Size
30 in.
Diameter
7.1 cm (2.8 in.)
Filtration Area
1.26 m²
Format
Triple Layer
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 140 mg per 10-inch cartridge after 24 hours in water at controlled room temperature.
Indirect Food Additive
All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182. All component materials meet the requirements of the EU framework regulation [1935/2004/EC] regarding materials and articles intended to contact food.
Length
30 in. (75 cm)
Material Package
Double Easy-Open bag
Material Size
3
Maximum Differential Pressure, bar (psid)
3.5 bar (50 psid) @ 25 °C
Maximum Inlet Pressure, bar (psi)
3.5 bar (50 psi) @ 25 °C
Media
Polysep™ II
Nominal Pore Size
1.0 / 0.2 / 0.1 µm
Non-Fiber Releasing
This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥15 L
Pore Size
1.0 / 0.2 / 0.1 µm
Sanitization
30 min with hot water @ 80 °C
Seal Material
Silicone (SI)
Sterilization
10 autoclave cycles or SIP @ 121 °C for 30 min
Support Material
Spun bonded polypropylene
Trade Name
Polysep®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Code
Code 7 (2-226) O-ring and spear
Cartridge Nominal Length
30 in. (75 cm)
Catalogue Number
CGW173S03
Chemistry
Mixed Cellulose Esters (MCE)
Device Configuration
Cartridge
Device Material
Polypropylene
Device Size
30 in.
Diameter
7.1 cm (2.8 in.)
Filtration Area
1.26 m²
Format
Triple Layer
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 140 mg per 10-inch cartridge after 24 hours in water at controlled room temperature.
Indirect Food Additive
All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182. All component materials meet the requirements of the EU framework regulation [1935/2004/EC] regarding materials and articles intended to contact food.
Length
30 in. (75 cm)
Material Package
Double Easy-Open bag
Material Size
3
Maximum Differential Pressure, bar (psid)
3.5 bar (50 psid) @ 25 °C
Maximum Inlet Pressure, bar (psi)
3.5 bar (50 psi) @ 25 °C
Media
Polysep™ II
Nominal Pore Size
1.0 / 0.2 / 0.1 µm
Non-Fiber Releasing
This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥15 L
Pore Size
1.0 / 0.2 / 0.1 µm
Sanitization
30 min with hot water @ 80 °C
Seal Material
Silicone (SI)
Sterilization
10 autoclave cycles or SIP @ 121 °C for 30 min
Support Material
Spun bonded polypropylene
Trade Name
Polysep®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Forward: 6.9 bar (100 psid) intermittent @ 25 °C; 5.5 bar (80 psid) @ 25 °C; 1.0 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C, intermittent
Maximum Inlet Pressure (psig)
80 psig
Maximum Inlet Pressure, bar (psi)
6.9 bar (100 psi) intermittent @ 25 °C; 5.5 bar (80 psi) @ 25 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
Maximum Inlet Temperature
25 °C
Media
Millipore Express® SHC
Non-Fiber Releasing
This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Outlet Connection
Hose Barb
Outlet Connection Diameter
1 in.
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥6 L
Pore Size
0.5 / 0.2 µm
Seal Material
Silicone (SI)
Sterility
Gamma
Sterilization
Gamma compatible to 45 kGy; 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
Support Material
Polyester
Trade Name
Millipore Express®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Forward: 6.9 bar (100 psid) intermittent @ 25 °C; 5.5 bar (80 psid) @ 25 °C; 1.0 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C, intermittent
Maximum Inlet Pressure (psig)
80 psig
Maximum Inlet Pressure, bar (psi)
6.9 bar (100 psi) intermittent @ 25 °C; 5.5 bar (80 psi) @ 25 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
Maximum Inlet Temperature
25 °C
Media
Millipore Express® SHC
Non-Fiber Releasing
This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Outlet Connection
Hose Barb
Outlet Connection Diameter
1 in.
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥6 L
Pore Size
0.5 / 0.2 µm
Seal Material
Silicone (SI)
Sterility
Gamma
Sterilization
Gamma compatible to 45 kGy; 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
Support Material
Polyester
Trade Name
Millipore Express®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.
Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.