We have developed a unique portfolio of consumables, each adapted to the different feed water quality requirements and to your various applications. To maintain your water system’s performance, it’s critical to replace your purification cartridges on time and with genuine ISO 9001-certified parts.

Catalog No. Product Net Price
CN1272E06 Polygard-CN Cartridge Filter 20 in. 1.2 µm Code 7 Ethylene-Propylene 1491 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 7 (2-226) O-rings w/locking-tabs
  • Cartridge Nominal Length
  • 20 in. (50 cm)
  • Catalogue Number
  • CN1272E06
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Filtration Area
  • 0.84 m²
  • Gravimetric Extractables
  • ≤100 mg after 24-h soak in water
  • Length
  • 20 in. (50 cm)
  • Material Size
  • 6
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 1.2 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥10 L
  • Pore Size
  • 1.2 µm
  • Sanitization
  • 30 min with hot water @ 80 °C
  • Seal Material
  • Ethylene Propylene
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Polygard®
  • Wettability
  • Hydrophilic
CN1272V06 Polygard-CN Cartridge Filter 20 in. 1.2 µm Code 7 Fluoroelastomer 1491 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 7 (2-226) O-rings w/locking-tabs
  • Cartridge Nominal Length
  • 20 in. (50 cm)
  • Catalogue Number
  • CN1272V06
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Filtration Area
  • 0.84 m²
  • Gravimetric Extractables
  • ≤100 mg after 24-h soak in water
  • Length
  • 20 in. (50 cm)
  • Material Size
  • 6
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 1.2 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥10 L
  • Pore Size
  • 1.2 µm
  • Sanitization
  • 30 min with hot water @ 80 °C
  • Seal Material
  • Fluorocarbon rubber
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Polygard®
  • Wettability
  • Hydrophilic
CVBW73PK3 Vitipore® II Cartridge Filter 30 in. 0.22 µm Code 7 1523 
Add to Cart
  • Cartridge Code
  • Code 7 (2-226) O-rings w/locking-tabs
  • Cartridge Nominal Length
  • 40 in. (100 cm)
  • Catalogue Number
  • CVBW73PK3
  • Chemistry
  • Polyvinylidene Fluoride (PVDF)
  • Device Configuration
  • Cartridge
  • Device Size
  • 30 in.
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 23 mg per 10-inch cartridge after 24 hours in water at controlled room temperature.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182. All component materials meet the requirements of the EU framework regulation [1935/2004/EC] regarding materials and articles intended to contact food.
  • Key Applications
  • Food and BeverageBeerBottled WaterWine
  • Length
  • 40 in. (100 cm)
  • Material Size
  • 3
  • Media
  • Vitipore® II
  • Non-Fiber Releasing
  • This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Pore Size
  • 0.22 µm
  • Sterility
  • Other
  • Trade Name
  • Vitipore® II
  • Wettability
  • Hydrophilic
CN0602E06 Polygard-CN Cartridge Filter 20 in. 0.6 µm Code 0 Ethylene-Propylene 1540 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 0 (2-222) O-rings
  • Cartridge Nominal Length
  • 20 in. (50 cm)
  • Catalogue Number
  • CN0602E06
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Filtration Area
  • 0.84 m²
  • Gravimetric Extractables
  • ≤100 mg after 24-h soak in water
  • Length
  • 20 in. (50 cm)
  • Material Size
  • 6
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 0.6 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥10 L
  • Pore Size
  • 0.6 µm
  • Sanitization
  • 30 min with hot water @ 80 °C
  • Seal Material
  • Ethylene Propylene
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Polygard®
  • Wettability
  • Hydrophilic
CN0602E06 Polygard-CN Cartridge Filter 20 in. 0.6 µm Code 0 Ethylene-Propylene 1540 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 0 (2-222) O-rings
  • Cartridge Nominal Length
  • 20 in. (50 cm)
  • Catalogue Number
  • CN0602E06
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Filtration Area
  • 0.84 m²
  • Gravimetric Extractables
  • ≤100 mg after 24-h soak in water
  • Length
  • 20 in. (50 cm)
  • Material Size
  • 6
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 0.6 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥10 L
  • Pore Size
  • 0.6 µm
  • Sanitization
  • 30 min with hot water @ 80 °C
  • Seal Material
  • Ethylene Propylene
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Polygard®
  • Wettability
  • Hydrophilic
CN1272T06 Polygard-CN Cartridge Filter 20 in. 1.2 µm Code 7 PTFE-encapsulated Fluoroelastomer 1540 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 7 (2-226) O-rings w/locking-tabs
  • Cartridge Nominal Length
  • 20 in. (50 cm)
  • Catalogue Number
  • CN1272T06
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Filtration Area
  • 0.84 m²
  • Gravimetric Extractables
  • ≤100 mg after 24-h soak in water
  • Length
  • 20 in. (50 cm)
  • Material Size
  • 6
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 1.2 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥10 L
  • Pore Size
  • 1.2 µm
  • Sanitization
  • 30 min with hot water @ 80 °C
  • Seal Material
  • Polytetrafluoroethylene (PTFE)
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Polygard®
  • Wettability
  • Hydrophilic
CGEP72TE3 Millipore Express® SHF Cartridge Filter 20 in. 0.2 µm Code 7 EPDM 1554 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Bacterial Retention
  • Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
  • Cartridge Code
  • Code 7
  • Cartridge Nominal Length
  • 20 in. (50 cm)
  • Catalogue Number
  • CGEP72TE3
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene/Polysulfone
  • Device Size
  • 20 in.
  • Diameter
  • 6.9 cm (2.7 in.)
  • Filtration Area
  • 1.1 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Length
  • 20 in. (50 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 3
  • Maximum Differential Pressure
  • Forward: 6900 mbar (100 psi) @ 25 °C; 1700 bar (25 psi) @ 80 °C; 340 mbar (5 psi) @ 135 °C. Reverse: 2100 mbar (30 psi) @ 25 °C, 69 mbar (1 psi) @ 135 °C
  • Maximum Inlet Pressure, bar (psi)
  • Forward - 7 bar (100 psi) @ 25 °C; 1.7 bar (25 psi) @ 80 °C; 0.35 bar (5 psi) @ 135 °C; Reverse - 2.07 bar (30 psi) @ 25 °C; 0.07 bar (1 psi) @ 135 °C
  • Media
  • Millipore Express® SHF
  • Non-Fiber Releasing
  • This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥2 L
  • Pore Size
  • 0.2 µm
  • Seal Material
  • EPDM
  • Sterilization
  • 25 forward or 22 forward and 3 reverse SIP cycles of 30 min @ 135 °C; 25 autoclave cycles of 60 min @ 126 °C
  • Support Material
  • Polypropylene
  • Trade Name
  • Millipore Express®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Wettability
  • Hydrophilic
CGEP72TE3 Millipore Express® SHF Cartridge Filter 20 in. 0.2 µm Code 7 EPDM 1554 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Bacterial Retention
  • Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
  • Cartridge Code
  • Code 7
  • Cartridge Nominal Length
  • 20 in. (50 cm)
  • Catalogue Number
  • CGEP72TE3
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene/Polysulfone
  • Device Size
  • 20 in.
  • Diameter
  • 6.9 cm (2.7 in.)
  • Filtration Area
  • 1.1 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Length
  • 20 in. (50 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 3
  • Maximum Differential Pressure
  • Forward: 6900 mbar (100 psi) @ 25 °C; 1700 bar (25 psi) @ 80 °C; 340 mbar (5 psi) @ 135 °C. Reverse: 2100 mbar (30 psi) @ 25 °C, 69 mbar (1 psi) @ 135 °C
  • Maximum Inlet Pressure, bar (psi)
  • Forward - 7 bar (100 psi) @ 25 °C; 1.7 bar (25 psi) @ 80 °C; 0.35 bar (5 psi) @ 135 °C; Reverse - 2.07 bar (30 psi) @ 25 °C; 0.07 bar (1 psi) @ 135 °C
  • Media
  • Millipore Express® SHF
  • Non-Fiber Releasing
  • This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥2 L
  • Pore Size
  • 0.2 µm
  • Seal Material
  • EPDM
  • Sterilization
  • 25 forward or 22 forward and 3 reverse SIP cycles of 30 min @ 135 °C; 25 autoclave cycles of 60 min @ 126 °C
  • Support Material
  • Polypropylene
  • Trade Name
  • Millipore Express®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Wettability
  • Hydrophilic
CGEP72TF3 Millipore Express® SHF Cartridge Filter 20 in. 0.2 µm Code 7 Fluorocarbon 1554 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Bacterial Retention
  • Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
  • Cartridge Code
  • Code 7
  • Cartridge Nominal Length
  • 20 in. (50 cm)
  • Catalogue Number
  • CGEP72TF3
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene/Polysulfone
  • Device Size
  • 20 in.
  • Diameter
  • 6.9 cm (2.7 in.)
  • Filtration Area
  • 1.1 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Length
  • 20 in. (50 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 3
  • Maximum Differential Pressure
  • Forward: 6900 mbar (100 psi) @ 25 °C; 1700 bar (25 psi) @ 80 °C; 340 mbar (5 psi) @ 135 °C. Reverse: 2100 mbar (30 psi) @ 25 °C, 69 mbar (1 psi) @ 135 °C
  • Maximum Inlet Pressure, bar (psi)
  • Forward - 7 bar (100 psi) @ 25 °C; 1.7 bar (25 psi) @ 80 °C; 0.35 bar (5 psi) @ 135 °C; Reverse - 2.07 bar (30 psi) @ 25 °C; 0.07 bar (1 psi) @ 135 °C
  • Media
  • Millipore Express® SHF
  • Non-Fiber Releasing
  • This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥2 L
  • Pore Size
  • 0.2 µm
  • Seal Material
  • Fluorocarbon rubber
  • Sterilization
  • 25 forward or 22 forward and 3 reverse SIP cycles of 30 min @ 135 °C; 25 autoclave cycles of 60 min @ 126 °C
  • Support Material
  • Polypropylene
  • Trade Name
  • Millipore Express®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Wettability
  • Hydrophilic
CGEP72TF3 Millipore Express® SHF Cartridge Filter 20 in. 0.2 µm Code 7 Fluorocarbon 1554 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Bacterial Retention
  • Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
  • Cartridge Code
  • Code 7
  • Cartridge Nominal Length
  • 20 in. (50 cm)
  • Catalogue Number
  • CGEP72TF3
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene/Polysulfone
  • Device Size
  • 20 in.
  • Diameter
  • 6.9 cm (2.7 in.)
  • Filtration Area
  • 1.1 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Length
  • 20 in. (50 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 3
  • Maximum Differential Pressure
  • Forward: 6900 mbar (100 psi) @ 25 °C; 1700 bar (25 psi) @ 80 °C; 340 mbar (5 psi) @ 135 °C. Reverse: 2100 mbar (30 psi) @ 25 °C, 69 mbar (1 psi) @ 135 °C
  • Maximum Inlet Pressure, bar (psi)
  • Forward - 7 bar (100 psi) @ 25 °C; 1.7 bar (25 psi) @ 80 °C; 0.35 bar (5 psi) @ 135 °C; Reverse - 2.07 bar (30 psi) @ 25 °C; 0.07 bar (1 psi) @ 135 °C
  • Media
  • Millipore Express® SHF
  • Non-Fiber Releasing
  • This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥2 L
  • Pore Size
  • 0.2 µm
  • Seal Material
  • Fluorocarbon rubber
  • Sterilization
  • 25 forward or 22 forward and 3 reverse SIP cycles of 30 min @ 135 °C; 25 autoclave cycles of 60 min @ 126 °C
  • Support Material
  • Polypropylene
  • Trade Name
  • Millipore Express®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Wettability
  • Hydrophilic

Overview

Analytical Sample Preparation Membrane Filtration Devices


Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.


Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.


Filter Membranes

Millex® Syringe Filters

Filtration Holders & Accessories



Resources