+852-3069 6950
css@gugent.com.hk
 

About 30 years ago MACHEREY‑NAGEL designed and introduced CHROMABOND SPE cartridges containing silica-based adsorbents.

SPE is a form of digital (step-wise) chromatography designed to extract, partition, and / or adsorb one or more components from a liquid phase (sample) onto a stationary phase (adsorbent or resin). An adsorbed substance can be removed from the adsorbent by stepwise increase of elution strength of the eluent (step gradient technique).

SPE extends a chromatographic system’s lifetime, improves qualitative and quantitative analysis, and the demand placed on an analytical instrument is considerably lessened.


Catalog No. Product Net Price
MN730013MPS SPE MPS columns, CHROMABOND C18 ec, 3 mL/500 mg Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE), automated
  • Brand
  • CHROMABOND
  • Phase
  • C18 ec
  • Mode
  • Reversed phase (RP)
  • Base material
  • Silica gel
  • Surface chemistry
  • Octadecyl (ODS, C18 ec, RP18 ec) modified silica phase, endcapped
  • Column type
  • SPE MPS column
  • Hardware
  • Polypropylene (PP) columns with polyethylene (PE) filter elements
  • Column shape
  • Tubular syringe-shaped SPE column - already equipped with special cap and cannula to be used in Gerstel MultiPurposeSampler (MPS)
  • Column volume
  • 3 mL
  • Filling quantity
  • 500 mg
  • Column volume/adsorbent weight
  • 3 mL/500 mg
  • Recommended application(s)
  • Aflatoxins, Chloramphenicol, Pesticides, Steroids, Vitamins
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 45 µm
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • pH stability
  • 2.0–8.0
  • Filter element material
  • Polyethylene (PE)
  • Storage temperature
  • RT
MN730073MPS SPE MPS columns, CHROMABOND SiOH, 3 mL/500 mg Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE), automated
  • Brand
  • CHROMABOND
  • Phase
  • SiOH
  • Mode
  • Normal phase (NP)
  • Base material
  • Silica gel
  • Surface chemistry
  • Unmodified silica gel (SiOH)
  • Column type
  • SPE MPS column
  • Hardware
  • Polypropylene (PP) columns with polyethylene (PE) filter elements
  • Column shape
  • Tubular syringe-shaped SPE column - already equipped with special cap and cannula to be used in Gerstel MultiPurposeSampler (MPS)
  • Column volume
  • 3 mL
  • Filling quantity
  • 500 mg
  • Column volume/adsorbent weight
  • 3 mL/500 mg
  • Recommended application(s)
  • Aflatoxins, Chloramphenicol, Pesticides, Steroids, Vitamins
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 45 µm
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • pH stability
  • 2.0–8.0
  • Filter element material
  • Polyethylene (PE)
  • Storage temperature
  • RT
MN730931MPS SPE MPS columns, CHROMABOND HR-X, 3 mL/200 mg Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE), automated
  • Brand
  • CHROMABOND
  • Phase
  • HR-X
  • Mode
  • Reversed phase (RP)
  • Base material
  • PS/DVB copolymer
  • Surface chemistry
  • Hydrophobic spherical polystyrene-divinylbenzene copolymer (PS/DVB)
  • Column type
  • SPE MPS column
  • Hardware
  • Polypropylene (PP) columns with polyethylene (PE) filter elements
  • Column shape
  • Tubular syringe-shaped SPE column - already equipped with special cap and cannula to be used in Gerstel MultiPurposeSampler (MPS)
  • Column volume
  • 3 mL
  • Filling quantity
  • 200 mg
  • Column volume/adsorbent weight
  • 3 mL/200 mg
  • Recommended application(s)
  • Active ingredients from creams, Active ingredients from tablets, Active ingredients from water/waste water, Drugs, Drugs from serum and plasma, Drugs from urine, Herbicide, PAHs and PCBs from water, PCB, Pharmaceuticals, Phenols, Trace analysis of pesticides
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 85 µm
  • Particle shape
  • Spherical
  • Specific surface according to BET
  • 1000 m²/g
  • pH stability
  • 1.0–14.0
  • Filter element material
  • Polyethylene (PE)
  • Storage temperature
  • RT
MN730935MPS SPE MPS columns, CHROMABOND HR-X, 1 mL/100 mg Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE), automated
  • Brand
  • CHROMABOND
  • Phase
  • HR-X
  • Mode
  • Reversed phase (RP)
  • Base material
  • PS/DVB copolymer
  • Surface chemistry
  • Hydrophobic spherical polystyrene-divinylbenzene copolymer (PS/DVB)
  • Column type
  • SPE MPS column
  • Hardware
  • Polypropylene (PP) columns with polyethylene (PE) filter elements
  • Column shape
  • Tubular syringe-shaped SPE column - already equipped with special cap and cannula to be used in Gerstel MultiPurposeSampler (MPS)
  • Column volume
  • 1 mL
  • Filling quantity
  • 100 mg
  • Column volume/adsorbent weight
  • 1 mL/100 mg
  • Recommended application(s)
  • Active ingredients from creams, Active ingredients from tablets, Active ingredients from water/waste water, Drugs, Drugs from serum and plasma, Drugs from urine, Herbicide, PAHs and PCBs from water, PCB, Pharmaceuticals, Phenols, Trace analysis of pesticides
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 85 µm
  • Particle shape
  • Spherical
  • Specific surface according to BET
  • 1000 m²/g
  • pH stability
  • 1.0–14.0
  • Filter element material
  • Polyethylene (PE)
  • Storage temperature
  • RT
MN730939MPS SPE MPS columns, CHROMABOND HR-X, 6 mL/500 mg Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE), automated
  • Brand
  • CHROMABOND
  • Phase
  • HR-X
  • Mode
  • Reversed phase (RP)
  • Base material
  • PS/DVB copolymer
  • Surface chemistry
  • Hydrophobic spherical polystyrene-divinylbenzene copolymer (PS/DVB)
  • Column type
  • SPE MPS column
  • Hardware
  • Polypropylene (PP) columns with polyethylene (PE) filter elements
  • Column shape
  • Tubular syringe-shaped SPE column - already equipped with special cap and cannula to be used in Gerstel MultiPurposeSampler (MPS)
  • Column volume
  • 6 mL
  • Filling quantity
  • 500 mg
  • Column volume/adsorbent weight
  • 6 mL/500 mg
  • Recommended application(s)
  • Active ingredients from creams, Active ingredients from tablets, Active ingredients from water/waste water, Drugs, Drugs from serum and plasma, Drugs from urine, Herbicide, PAHs and PCBs from water, PCB, Pharmaceuticals, Phenols, Trace analysis of pesticides
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 85 µm
  • Particle shape
  • Spherical
  • Specific surface according to BET
  • 1000 m²/g
  • pH stability
  • 1.0–14.0
  • Filter element material
  • Polyethylene (PE)
  • Storage temperature
  • RT
MN815030.5 LC packing material (adsorbents, bulk), Aluminum oxide, Alox A, acidic Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • LC, packing material (adsorbent, bulk)
  • Phase
  • Alox A
  • Mode
  • Normal phase (NP)
  • Base material
  • Aluminum oxide
  • Surface chemistry
  • Aluminum oxide, acidic
  • Endcapped
  • No
  • Selling unit
  • 1 kg, 5 kg, 25 kg
  • Recommended application(s)
  • LC packing material
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 50–200 µm
  • Pore size
  • 90 Å
  • Particle shape
  • Irregular
  • Storage temperature
  • RT
MN815010.25 LC packing material (adsorbents, bulk), Aluminum oxide, Alox B, basic Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • LC, packing material (adsorbent, bulk)
  • Phase
  • Alox B
  • Mode
  • Normal phase (NP)
  • Base material
  • Aluminum oxide
  • Surface chemistry
  • Aluminum oxide, basic
  • Endcapped
  • No
  • Recommended application(s)
  • LC packing material
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 50–200 µm
  • Pore size
  • 90 Å
  • Particle shape
  • Irregular
  • Storage temperature
  • RT
MN815010.5 LC packing material (adsorbents, bulk), Aluminum oxide, Alox B, basic Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • LC, packing material (adsorbent, bulk)
  • Phase
  • Alox B
  • Mode
  • Normal phase (NP)
  • Base material
  • Aluminum oxide
  • Surface chemistry
  • Aluminum oxide, basic
  • Endcapped
  • No
  • Selling unit
  • 1 kg, 5 kg
  • Recommended application(s)
  • LC packing material
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 50–200 µm
  • Pore size
  • 90 Å
  • Particle shape
  • Irregular
  • Storage temperature
  • RT
MN815020.5 LC packing material (adsorbents, bulk), Aluminum oxide, Alox N, neutral Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • LC, packing material (adsorbent, bulk)
  • Phase
  • Alox N
  • Mode
  • Normal phase (NP)
  • Base material
  • Aluminum oxide
  • Surface chemistry
  • Aluminum oxide, neutral
  • Endcapped
  • No
  • Selling unit
  • 1 kg, 5 kg, 25 kg
  • Recommended application(s)
  • LC packing material
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 50–200 µm
  • Pore size
  • 90 Å
  • Particle shape
  • Irregular
  • Storage temperature
  • RT
MN730017 SPE columns, CHROMABOND Alox A, 60–150 µm, 6 mL/1000 mg Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE)
  • Brand
  • CHROMABOND
  • Phase
  • Alox A
  • Mode
  • Normal phase (NP)
  • Base material
  • Aluminum oxide
  • Surface chemistry
  • Aluminum oxide, acidic
  • Column type
  • SPE column
  • Hardware
  • Polypropylene (PP) columns with polyethylene (PE) filter elements
  • Column shape
  • Open tubular syringe-shaped column with Luer tip outlet
  • Column volume
  • 6 mL
  • Filling quantity
  • 1000 mg
  • Column volume/adsorbent weight
  • 6 mL/1000 mg
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 60–150 µm
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 150 m²/g
  • pH stability
  • Not available or not applicable
  • Filter element material
  • Polyethylene (PE)
  • Storage temperature
  • RT

Overview

Main steps of the SPE procedure

1) Conditioning

Conditioning of the adsorbent is necessary in order to ensure reproducible interaction with the analyte. Conditioning, also called solvation, results in a wetting of the adsorbent and thus produces an environment, which is suitable for adsorption of the analyte. Nonpolar adsorbents are usually conditioned with 2–3 column volumes of a solvent, which is miscible with water (methanol, THF, 2-propanol etc.), followed by the solvent in which the analyte is dissolved (pure matrix, e.g., water, buffer). Polar adsorbents are conditioned with nonpolar solvents. After the conditioning step the adsorbent bed must not run dry, because otherwise solvation is destroyed (deconditioning).


2) Sample application (adsorption)

Sample application can be performed with positive or negative pressure with a flow rate of ~3 mL/min. Sample volumes vary from a few mL up to liters.


3) Washing

Washing of the adsorbent is usually achieved with a special wash solution; however, in some cases it may not be necessary. If the polarity difference between wash solution and eluent is very large, or if both are not miscible, drying of the adsorbent bed after washing is recommended to improve elution and recovery.


4) Elution

Elution with a suitable eluent should not be too fast. The elution speed depends on the column or cartridge dimension and the quantity of adsorbent (about 1 mL/min).


Since analytes can either be adsorbed on the SPE packing material or directly flown through while the interfering substances are retained, two general separation procedures are possible – both cases are shown in the figure below.



Resources