About 30 years ago MACHEREY‑NAGEL designed and introduced CHROMABOND SPE cartridges containing silica-based adsorbents.

SPE is a form of digital (step-wise) chromatography designed to extract, partition, and / or adsorb one or more components from a liquid phase (sample) onto a stationary phase (adsorbent or resin). An adsorbed substance can be removed from the adsorbent by stepwise increase of elution strength of the eluent (step gradient technique).

SPE extends a chromatographic system’s lifetime, improves qualitative and quantitative analysis, and the demand placed on an analytical instrument is considerably lessened.


Catalog No. Product Net Price
MN731923 SPE cartridges, CHROMAFIX HLB (60 µm), Large Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE)
  • Brand
  • CHROMAFIX
  • Phase
  • HLB
  • Mode
  • Reversed phase (RP)
  • Base material
  • N-vinylpyrrolidone-divinylbenzene
  • Surface chemistry
  • Hydrophilic-lipophilic balanced N-vinylpyrrolidone-divinylbenzene
  • Column type
  • SPE cartridge
  • Hardware
  • Polypropylene (PP) cartridges with polyethylene (PE) filter elements
  • Column shape
  • Tubular syringe-shaped cartridge with Luer tip inlet and outlet
  • Filling quantity
  • 350 mg
  • Recommended application(s)
  • Chloramphenicol, Iodinated contrast media, Pesticides, Polar organic molecules from polar matrices, Sulfonamide
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 60 µm
  • Particle shape
  • Spherical
  • Specific surface according to BET
  • 750 m²/g
  • pH stability
  • 1.0–14.0
  • Filter element material
  • Polyethylene (PE)
  • Storage temperature
  • RT
MN731835 SPE cartridges, CHROMAFIX SB, Medium Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE)
  • Brand
  • CHROMAFIX
  • Phase
  • SB
  • Mode
  • Ion exchange (IEX)
  • Base material
  • Silica gel
  • Surface chemistry
  • Silica gel with quaternary ammonium modification, strongly basic anion exchanger (SAX)
  • Column type
  • SPE cartridge
  • Hardware
  • Polypropylene (PP) cartridges with polyethylene (PE) filter elements
  • Column shape
  • Tubular syringe-shaped cartridge with Luer tip inlet and outlet
  • Filling quantity
  • 180 mg
  • Recommended application(s)
  • Caffeine, Organic acids, Saccharin
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 45 µm
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • pH stability
  • 2.0–8.0
  • Filter element material
  • Polyethylene (PE)
  • Storage temperature
  • RT
MN731836 SPE cartridges, CHROMAFIX SB, Large Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE)
  • Brand
  • CHROMAFIX
  • Phase
  • SB
  • Mode
  • Ion exchange (IEX)
  • Base material
  • Silica gel
  • Surface chemistry
  • Silica gel with quaternary ammonium modification, strongly basic anion exchanger (SAX)
  • Column type
  • SPE cartridge
  • Hardware
  • Polypropylene (PP) cartridges with polyethylene (PE) filter elements
  • Column shape
  • Tubular syringe-shaped cartridge with Luer tip inlet and outlet
  • Filling quantity
  • 500 mg
  • Recommended application(s)
  • Caffeine, Organic acids, Saccharin
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 45 µm
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • pH stability
  • 2.0–8.0
  • Filter element material
  • Polyethylene (PE)
  • Storage temperature
  • RT
MN738637 CHROMABOND Multi 96 collection rack for PP-Vessels (12x8-well-strips), 96x1.0 mL Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE), accessory
  • Brand
  • CHROMABOND
  • Hardware
  • Polypropylene (PP)
  • Recommended application(s)
  • Accessories for SPE applications (solid phase extraction - sample preparation
  • Storage temperature
  • RT
MN730011ASP SPE Aspec columns, CHROMABOND C18 ec, 1 mL/100 mg Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE), automated
  • Brand
  • CHROMABOND
  • Phase
  • C18 ec
  • Mode
  • Reversed phase (RP)
  • Base material
  • Silica gel
  • Surface chemistry
  • Octadecyl (ODS, C18 ec, RP18 ec) modified silica phase, endcapped
  • Column type
  • SPE Aspec column
  • Hardware
  • Polypropylene (PP) columns with polyethylene (PE) filter elements
  • Column shape
  • Tubular syringe-shaped SPE column - already assembled with caps for ASPEC systems
  • Column volume
  • 1 mL
  • Filling quantity
  • 100 mg
  • Column volume/adsorbent weight
  • 1 mL/100 mg
  • Recommended application(s)
  • Aflatoxins, Chloramphenicol, Pesticides, Steroids, Vitamins
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 45 µm
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • pH stability
  • 2.0–8.0
  • Filter element material
  • Polyethylene (PE)
  • Storage temperature
  • RT
MN730013ASP SPE Aspec columns, CHROMABOND C18 ec, 3 mL/500 mg Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE), automated
  • Brand
  • CHROMABOND
  • Phase
  • C18 ec
  • Mode
  • Reversed phase (RP)
  • Base material
  • Silica gel
  • Surface chemistry
  • Octadecyl (ODS, C18 ec, RP18 ec) modified silica phase, endcapped
  • Column type
  • SPE Aspec column
  • Hardware
  • Polypropylene (PP) columns with polyethylene (PE) filter elements
  • Column shape
  • Tubular syringe-shaped SPE column - already assembled with caps for ASPEC systems
  • Column volume
  • 3 mL
  • Filling quantity
  • 500 mg
  • Column volume/adsorbent weight
  • 3 mL/500 mg
  • Recommended application(s)
  • Aflatoxins, Chloramphenicol, Pesticides, Steroids, Vitamins
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 45 µm
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • pH stability
  • 2.0–8.0
  • Filter element material
  • Polyethylene (PE)
  • Storage temperature
  • RT
MN730249 SPE columns, CHROMABOND Na₂SO₄/Florisil, 6 mL/2/2g Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE)
  • Brand
  • CHROMABOND
  • Phase
  • Na₂SO₄/Florisil
  • Mode
  • Special application or diverse
  • Base material
  • Sodium sulfate/magnesium silicate
  • Surface chemistry
  • Sodium sulfate and magnesium silicate (MgO – SiOH 15/85)
  • Column type
  • SPE column
  • Hardware
  • Polypropylene (PP) columns with polyethylene (PE) filter elements
  • Column shape
  • Open tubular syringe-shaped column with Luer tip outlet
  • Column volume
  • 6 mL
  • Filling quantity
  • 2/2g
  • Column volume/adsorbent weight
  • 6 mL/2/2g
  • Recommended application(s)
  • Hydrocarbons from water acc. to DIN H53 /ISO DIS 9377-4
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Irregular
  • pH stability
  • Not available or not applicable
  • Filter element material
  • Polyethylene (PE)
  • Storage temperature
  • RT
MN730249G SPE glass columns, CHROMABOND Na₂SO₄/Florisil, 6 mL/2/2g Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE)
  • Brand
  • CHROMABOND
  • Phase
  • Na₂SO₄/Florisil
  • Mode
  • Special application or diverse
  • Base material
  • Sodium sulfate/magnesium silicate
  • Surface chemistry
  • Sodium sulfate and magnesium silicate (MgO – SiOH 15/85)
  • Column type
  • SPE glass column
  • Hardware
  • Glass columns (borosilicate type I) with glass fiber (GF) filter elements
  • Column shape
  • Open tubular syringe-shaped column with Luer tip outlet
  • Column volume
  • 6 mL
  • Filling quantity
  • 2/2g
  • Column volume/adsorbent weight
  • 6 mL/2/2g
  • Selling unit
  • 30 columns, 250 columns
  • Recommended application(s)
  • Hydrocarbons from water acc. to DIN H53 /ISO DIS 9377-4
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Irregular
  • pH stability
  • Not available or not applicable
  • Filter element material
  • Glass fiber (GF)
  • Storage temperature
  • RT
MN730085 SPE columns, CHROMABOND SiOH-H₂SO₄/SA, 45 µm, 3 mL/500/500 mg Special offer 
Add to Cart
  • Hazardous material
  • Yes
  • Method
  • Solid phase extraction (SPE)
  • Brand
  • CHROMABOND
  • Phase
  • SiOH-H₂SO₄/SA
  • Mode
  • Special application or diverse
  • Base material
  • Silica gel
  • Surface chemistry
  • Special combination of SiOH-H₂SO₄- Silica phase (SiOH) impregnated with sulfuric acid (H₂SO₄) and SA- strongly acidic cation exchanger (SCX) based on silica with benzene­sulfonic acid modification
  • Column type
  • SPE column
  • Hardware
  • Polypropylene (PP) columns with polyethylene (PE) filter elements
  • Column shape
  • Open tubular syringe-shaped column with Luer tip outlet
  • Column volume
  • 3 mL
  • Filling quantity
  • 500/500 mg
  • Column volume/adsorbent weight
  • 3 mL/500/500 mg
  • Selling unit
  • 50 columns, 250 columns
  • Recommended application(s)
  • Extraction of PCBs from oil with reference to German industrial standard DIN 51527, part 1, PCB
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 45 µm
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • pH stability
  • 2.0–8.0
  • Filter element material
  • Polyethylene (PE)
  • Storage temperature
  • 2−8 °C
MN730061 SPE columns, CHROMABOND CN, 45 µm, 1 mL/100 mg Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE)
  • Brand
  • CHROMABOND
  • Phase
  • CN
  • Mode
  • Normal phase (NP)
  • Base material
  • Silica gel
  • Surface chemistry
  • Cyanopropyl (CN, nitrile) modified silica phase
  • Column type
  • SPE column
  • Hardware
  • Polypropylene (PP) columns with polyethylene (PE) filter elements
  • Column shape
  • Open tubular syringe-shaped column with Luer tip outlet
  • Column volume
  • 1 mL
  • Filling quantity
  • 100 mg
  • Column volume/adsorbent weight
  • 1 mL/100 mg
  • Recommended application(s)
  • Carbohydrates, Cyclosporins
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 45 µm
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • pH stability
  • 2.0–8.0
  • Filter element material
  • Polyethylene (PE)
  • Storage temperature
  • RT

Overview

Main steps of the SPE procedure

1) Conditioning

Conditioning of the adsorbent is necessary in order to ensure reproducible interaction with the analyte. Conditioning, also called solvation, results in a wetting of the adsorbent and thus produces an environment, which is suitable for adsorption of the analyte. Nonpolar adsorbents are usually conditioned with 2–3 column volumes of a solvent, which is miscible with water (methanol, THF, 2-propanol etc.), followed by the solvent in which the analyte is dissolved (pure matrix, e.g., water, buffer). Polar adsorbents are conditioned with nonpolar solvents. After the conditioning step the adsorbent bed must not run dry, because otherwise solvation is destroyed (deconditioning).


2) Sample application (adsorption)

Sample application can be performed with positive or negative pressure with a flow rate of ~3 mL/min. Sample volumes vary from a few mL up to liters.


3) Washing

Washing of the adsorbent is usually achieved with a special wash solution; however, in some cases it may not be necessary. If the polarity difference between wash solution and eluent is very large, or if both are not miscible, drying of the adsorbent bed after washing is recommended to improve elution and recovery.


4) Elution

Elution with a suitable eluent should not be too fast. The elution speed depends on the column or cartridge dimension and the quantity of adsorbent (about 1 mL/min).


Since analytes can either be adsorbed on the SPE packing material or directly flown through while the interfering substances are retained, two general separation procedures are possible – both cases are shown in the figure below.



Resources