+852-3069 6950
css@gugent.com.hk
 

About 30 years ago MACHEREY‑NAGEL designed and introduced CHROMABOND SPE cartridges containing silica-based adsorbents.

SPE is a form of digital (step-wise) chromatography designed to extract, partition, and / or adsorb one or more components from a liquid phase (sample) onto a stationary phase (adsorbent or resin). An adsorbed substance can be removed from the adsorbent by stepwise increase of elution strength of the eluent (step gradient technique).

SPE extends a chromatographic system’s lifetime, improves qualitative and quantitative analysis, and the demand placed on an analytical instrument is considerably lessened.


Catalog No. Product Net Price
MN731808 SPE cartridges, CHROMAFIX C8, Medium Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE)
  • Brand
  • CHROMAFIX
  • Phase
  • C8
  • Mode
  • Reversed phase (RP)
  • Base material
  • Silica gel
  • Surface chemistry
  • Octyl (MOS, C8, RP8) modified silica phase, not endcapped
  • Column type
  • SPE cartridge
  • Hardware
  • Polypropylene (PP) cartridges with polyethylene (PE) filter elements
  • Column shape
  • Tubular syringe-shaped cartridge with Luer tip inlet and outlet
  • Filling quantity
  • 210 mg
  • Recommended application(s)
  • PCBs, Pesticides, Similar to C18
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 45 µm
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • pH stability
  • 2.0–8.0
  • Filter element material
  • Polyethylene (PE)
  • Storage temperature
  • RT
MN731831 SPE cartridges, CHROMAFIX SA, Small Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE)
  • Brand
  • CHROMAFIX
  • Phase
  • SA
  • Mode
  • Ion exchange (IEX)
  • Base material
  • Silica gel
  • Surface chemistry
  • Silica gel with benzenesulfonic acid modification, strongly acidic cation exchanger (SCX)
  • Column type
  • SPE cartridge
  • Hardware
  • Polypropylene (PP) cartridges with polyethylene (PE) filter elements
  • Column shape
  • Tubular syringe-shaped cartridge with Luer tip inlet and outlet
  • Filling quantity
  • 80 mg
  • Recommended application(s)
  • Amines, Amino acids, Chlorophyll, PCBs
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 45 µm
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • pH stability
  • 2.0–8.0
  • Filter element material
  • Polyethylene (PE)
  • Storage temperature
  • RT
MN731832 SPE cartridges, CHROMAFIX SA, Medium Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE)
  • Brand
  • CHROMAFIX
  • Phase
  • SA
  • Mode
  • Ion exchange (IEX)
  • Base material
  • Silica gel
  • Surface chemistry
  • Silica gel with benzenesulfonic acid modification, strongly acidic cation exchanger (SCX)
  • Column type
  • SPE cartridge
  • Hardware
  • Polypropylene (PP) cartridges with polyethylene (PE) filter elements
  • Column shape
  • Tubular syringe-shaped cartridge with Luer tip inlet and outlet
  • Filling quantity
  • 200 mg
  • Recommended application(s)
  • Amines, Amino acids, Chlorophyll, PCBs
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 45 µm
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • pH stability
  • 2.0–8.0
  • Filter element material
  • Polyethylene (PE)
  • Storage temperature
  • RT
MN731833 SPE cartridges, CHROMAFIX SA, Large Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE)
  • Brand
  • CHROMAFIX
  • Phase
  • SA
  • Mode
  • Ion exchange (IEX)
  • Base material
  • Silica gel
  • Surface chemistry
  • Silica gel with benzenesulfonic acid modification, strongly acidic cation exchanger (SCX)
  • Column type
  • SPE cartridge
  • Hardware
  • Polypropylene (PP) cartridges with polyethylene (PE) filter elements
  • Column shape
  • Tubular syringe-shaped cartridge with Luer tip inlet and outlet
  • Filling quantity
  • 580 mg
  • Recommended application(s)
  • Amines, Amino acids, Chlorophyll, PCBs
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 45 µm
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • pH stability
  • 2.0–8.0
  • Filter element material
  • Polyethylene (PE)
  • Storage temperature
  • RT
MN731839 SPE cartridges, CHROMAFIX HR-P, Small Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE)
  • Brand
  • CHROMAFIX
  • Phase
  • HR-P
  • Mode
  • Reversed phase (RP)
  • Base material
  • PS/DVB copolymer
  • Surface chemistry
  • Hydrophobic polystyrene-divinylbenzene copolymer (PS/DVB)
  • Column type
  • SPE cartridge
  • Hardware
  • Polypropylene (PP) cartridges with polyethylene (PE) filter elements
  • Column shape
  • Tubular syringe-shaped cartridge with Luer tip inlet and outlet
  • Filling quantity
  • 50 mg
  • Recommended application(s)
  • Aromatic compounds, Nitroaromatics from water, PAHs from oil, Pesticides from water, Phenols from water
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 50–100 µm
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 1200 m²/g
  • pH stability
  • 1.0–14.0
  • Filter element material
  • Polyethylene (PE)
  • Storage temperature
  • RT
MN731840 SPE cartridges, CHROMAFIX HR-P, Medium Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE)
  • Brand
  • CHROMAFIX
  • Phase
  • HR-P
  • Mode
  • Reversed phase (RP)
  • Base material
  • PS/DVB copolymer
  • Surface chemistry
  • Hydrophobic polystyrene-divinylbenzene copolymer (PS/DVB)
  • Column type
  • SPE cartridge
  • Hardware
  • Polypropylene (PP) cartridges with polyethylene (PE) filter elements
  • Column shape
  • Tubular syringe-shaped cartridge with Luer tip inlet and outlet
  • Filling quantity
  • 175 mg
  • Recommended application(s)
  • Aromatic compounds, Nitroaromatics from water, PAHs from oil, Pesticides from water, Phenols from water
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 50–100 µm
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 1200 m²/g
  • pH stability
  • 1.0–14.0
  • Filter element material
  • Polyethylene (PE)
  • Storage temperature
  • RT
MN731841 SPE cartridges, CHROMAFIX HR-P, Large Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE)
  • Brand
  • CHROMAFIX
  • Phase
  • HR-P
  • Mode
  • Reversed phase (RP)
  • Base material
  • PS/DVB copolymer
  • Surface chemistry
  • Hydrophobic polystyrene-divinylbenzene copolymer (PS/DVB)
  • Column type
  • SPE cartridge
  • Hardware
  • Polypropylene (PP) cartridges with polyethylene (PE) filter elements
  • Column shape
  • Tubular syringe-shaped cartridge with Luer tip inlet and outlet
  • Filling quantity
  • 380 mg
  • Recommended application(s)
  • Aromatic compounds, Nitroaromatics from water, PAHs from oil, Pesticides from water, Phenols from water
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 50–100 µm
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 1200 m²/g
  • pH stability
  • 1.0–14.0
  • Filter element material
  • Polyethylene (PE)
  • Storage temperature
  • RT
MN731844 SPE cartridges, CHROMAFIX Alox N, Medium Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE)
  • Brand
  • CHROMAFIX
  • Phase
  • Alox N
  • Mode
  • Normal phase (NP)
  • Base material
  • Aluminum oxide
  • Surface chemistry
  • Aluminum oxide, neutral
  • Column type
  • SPE cartridge
  • Hardware
  • Polypropylene (PP) cartridges with polyethylene (PE) filter elements
  • Column shape
  • Tubular syringe-shaped cartridge with Luer tip inlet and outlet
  • Filling quantity
  • 450 mg
  • Recommended application(s)
  • Antibiotics, Cation or anion exchange, Especially for polar compounds, Glycosides, Hormones, Vitamins
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 60–150 µm
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 150 m²/g
  • pH stability
  • Not available or not applicable
  • Filter element material
  • Polyethylene (PE)
  • Storage temperature
  • RT
MN731845 SPE cartridges, CHROMAFIX Alox N, Large Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE)
  • Brand
  • CHROMAFIX
  • Phase
  • Alox N
  • Mode
  • Normal phase (NP)
  • Base material
  • Aluminum oxide
  • Surface chemistry
  • Aluminum oxide, neutral
  • Column type
  • SPE cartridge
  • Hardware
  • Polypropylene (PP) cartridges with polyethylene (PE) filter elements
  • Column shape
  • Tubular syringe-shaped cartridge with Luer tip inlet and outlet
  • Filling quantity
  • 1200 mg
  • Recommended application(s)
  • Antibiotics, Cation or anion exchange, Especially for polar compounds, Glycosides, Hormones, Vitamins
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 60–150 µm
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 150 m²/g
  • pH stability
  • Not available or not applicable
  • Filter element material
  • Polyethylene (PE)
  • Storage temperature
  • RT
MN731848 SPE cartridges, CHROMAFIX Florisil, Large Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE)
  • Brand
  • CHROMAFIX
  • Phase
  • Florisil
  • Mode
  • Normal phase (NP)
  • Base material
  • Magnesium silicate
  • Surface chemistry
  • Magnesium silicate (MgO – SiOH 15/85)
  • Column type
  • SPE cartridge
  • Hardware
  • Polypropylene (PP) cartridges with polyethylene (PE) filter elements
  • Column shape
  • Tubular syringe-shaped cartridge with Luer tip inlet and outlet
  • Filling quantity
  • 700 mg
  • Recommended application(s)
  • Aliphatic carboxylic acids, Antibiotics, Clean-up of pesticide residues, Extraction of steroids, Lipids, Organic tin compounds, PAH, PCBs, Separation of chlorinated pesticides, Sex hormones
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 150–250 µm
  • Particle shape
  • Irregular
  • pH stability
  • Not available or not applicable
  • Filter element material
  • Polyethylene (PE)
  • Storage temperature
  • RT

Overview

Main steps of the SPE procedure

1) Conditioning

Conditioning of the adsorbent is necessary in order to ensure reproducible interaction with the analyte. Conditioning, also called solvation, results in a wetting of the adsorbent and thus produces an environment, which is suitable for adsorption of the analyte. Nonpolar adsorbents are usually conditioned with 2–3 column volumes of a solvent, which is miscible with water (methanol, THF, 2-propanol etc.), followed by the solvent in which the analyte is dissolved (pure matrix, e.g., water, buffer). Polar adsorbents are conditioned with nonpolar solvents. After the conditioning step the adsorbent bed must not run dry, because otherwise solvation is destroyed (deconditioning).


2) Sample application (adsorption)

Sample application can be performed with positive or negative pressure with a flow rate of ~3 mL/min. Sample volumes vary from a few mL up to liters.


3) Washing

Washing of the adsorbent is usually achieved with a special wash solution; however, in some cases it may not be necessary. If the polarity difference between wash solution and eluent is very large, or if both are not miscible, drying of the adsorbent bed after washing is recommended to improve elution and recovery.


4) Elution

Elution with a suitable eluent should not be too fast. The elution speed depends on the column or cartridge dimension and the quantity of adsorbent (about 1 mL/min).


Since analytes can either be adsorbed on the SPE packing material or directly flown through while the interfering substances are retained, two general separation procedures are possible – both cases are shown in the figure below.



Resources