+852-3069 6950
css@gugent.com.hk
 

Stainless steel HPLC columns for analytical or preparative applictions from MACHEREY‑NAGEL are a great choice for your daily labwork.

* NUCLEOSIL HPLC phases have gained wide acceptance as routine chromatographic packings for very different fields of modern chromatography. It is one of the first spherical silicas used in HPLC and is an absolutely reliable choice for routine analyses.

* NUCLEODUR as a state-of-the-art silica is the ideal base material for modern HPLC phases. It is the result of MACHEREY-NAGEL's pioneering research in chromatography for almost 50 years. NUCLEODUR HPLC columns with 1.8 µm particle size for increased separation efficiency are used for UHPLC applications.

* Due to core-shell technology NUCLEOSHELL columns provide highly efficient separation results with a comparably lower back pressure to fully porous materials.

Catalog No. Product Net Price
MN760785.40 EC HPLC column (analytical), NUCLEODUR C18 PAH, 3 µm, 150x4 mm Special offer 
Add to Cart
  • Recommended application(s)
  • PAHs according to EPA, Reversed phase, RP applications HPLC
  • Storage temperature
  • RT
  • Scope of delivery
  • 1x analytical HPLC column, instruction leaflet, certificate of analysis
  • Hazardous material
  • No
  • Method
  • HPLC, analytical
  • Brand
  • NUCLEODUR
  • Base material
  • NUCLEODUR - high purity silica
  • Phase
  • NUCLEODUR C18 PAH
  • USP listing
  • L118
  • Surface chemistry
  • Special octadecyl (C18, ODS) modification
  • Mode
  • Reversed phase (RP)
  • Type
  • EC HPLC column (analytical)
  • Hardware
  • Stainless steel
  • Column length
  • 150 mm
  • Column inner diameter
  • 4 mm
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • 3 µm
  • Eluent in HPLC column
  • Acetonitrile – water (70/30, v/v)
  • Endcapped
  • Yes
  • Carbon content
  • Not available or proprietary
  • pH stability
  • 2.0–8.0
  • Pore size
  • 110 Å
  • Specific surface according to BET
  • 340 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 600 bar
  • Column volume
  • 1.9 mL
MN760786.30 EC HPLC column (analytical), NUCLEODUR C18 PAH, 3 µm, 250x3 mm Special offer 
Add to Cart
  • Recommended application(s)
  • PAHs according to EPA, Reversed phase, RP applications HPLC
  • Storage temperature
  • RT
  • Scope of delivery
  • 1x analytical HPLC column, instruction leaflet, certificate of analysis
  • Hazardous material
  • No
  • Method
  • HPLC, analytical
  • Brand
  • NUCLEODUR
  • Base material
  • NUCLEODUR - high purity silica
  • Phase
  • NUCLEODUR C18 PAH
  • USP listing
  • L118
  • Surface chemistry
  • Special octadecyl (C18, ODS) modification
  • Mode
  • Reversed phase (RP)
  • Type
  • EC HPLC column (analytical)
  • Hardware
  • Stainless steel
  • Column length
  • 250 mm
  • Column inner diameter
  • 3 mm
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • 3 µm
  • Eluent in HPLC column
  • Acetonitrile – water (70/30, v/v)
  • Endcapped
  • Yes
  • Carbon content
  • Not available or proprietary
  • pH stability
  • 2.0–8.0
  • Pore size
  • 110 Å
  • Specific surface according to BET
  • 340 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 600 bar
  • Column volume
  • 1.75 mL
MN760786.40 EC HPLC column (analytical), NUCLEODUR C18 PAH, 3 µm, 250x4 mm Special offer 
Add to Cart
  • Recommended application(s)
  • PAHs according to EPA, Reversed phase, RP applications HPLC
  • Storage temperature
  • RT
  • Scope of delivery
  • 1x analytical HPLC column, instruction leaflet, certificate of analysis
  • Hazardous material
  • No
  • Method
  • HPLC, analytical
  • Brand
  • NUCLEODUR
  • Base material
  • NUCLEODUR - high purity silica
  • Phase
  • NUCLEODUR C18 PAH
  • USP listing
  • L118
  • Surface chemistry
  • Special octadecyl (C18, ODS) modification
  • Mode
  • Reversed phase (RP)
  • Type
  • EC HPLC column (analytical)
  • Hardware
  • Stainless steel
  • Column length
  • 250 mm
  • Column inner diameter
  • 4 mm
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • 3 µm
  • Eluent in HPLC column
  • Acetonitrile – water (70/30, v/v)
  • Endcapped
  • Yes
  • Carbon content
  • Not available or proprietary
  • pH stability
  • 2.0–8.0
  • Pore size
  • 110 Å
  • Specific surface according to BET
  • 340 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 600 bar
  • Column volume
  • 3.15 mL
MN720231.40 EC HPLC column (analytical), NUCLEOSIL 100-5 C18 MPN, 5 µm, 250x4 mm Special offer 
Add to Cart
  • Recommended application(s)
  • Biological macromolecules, HPLC
  • Storage temperature
  • RT
  • Scope of delivery
  • 1x analytical HPLC column, instruction leaflet, certificate of analysis
  • Hazardous material
  • No
  • Method
  • HPLC, analytical
  • Brand
  • NUCLEOSIL
  • Base material
  • NUCLEOSIL - the standard silica
  • Phase
  • NUCLEOSIL 100-5 C18 MPN
  • USP listing
  • L1
  • Surface chemistry
  • Special octadecyl (C18, ODS) modification
  • Mode
  • Special application or diverse
  • Type
  • EC HPLC column (analytical)
  • Hardware
  • Stainless steel
  • Column length
  • 250 mm
  • Column inner diameter
  • 4 mm
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • 5 µm
  • Eluent in HPLC column
  • Methanol
  • Endcapped
  • No
  • Carbon content
  • Not available or proprietary
  • pH stability
  • 1.0–9.0
  • Pore size
  • 100 Å
  • Specific surface according to BET
  • 350 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 250 bar
MN720245.40 EC HPLC column (analytical), NUCLEOSIL 300-5 C4 MPN, 5 µm, 250x4 mm Special offer 
Add to Cart
  • Recommended application(s)
  • Biological macromolecules, HPLC
  • Storage temperature
  • RT
  • Scope of delivery
  • 1x analytical HPLC column, instruction leaflet, certificate of analysis
  • Hazardous material
  • No
  • Method
  • HPLC, analytical
  • Brand
  • NUCLEOSIL
  • Base material
  • NUCLEOSIL - the standard silica
  • Phase
  • NUCLEOSIL 300-5 C4 MPN
  • USP listing
  • L26
  • Surface chemistry
  • Special butyl (C4) modification
  • Mode
  • Special application or diverse
  • Type
  • EC HPLC column (analytical)
  • Hardware
  • Stainless steel
  • Column length
  • 250 mm
  • Column inner diameter
  • 4 mm
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • 5 µm
  • Eluent in HPLC column
  • Methanol
  • Endcapped
  • No
  • Carbon content
  • Not available or proprietary
  • pH stability
  • 1.0–9.0
  • Pore size
  • 300 Å
  • Specific surface according to BET
  • 100 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 250 bar
MN720258.40 EC HPLC column (analytical), NUCLEOSIL 500-5 C18 PPN, 5 µm, 250x4 mm Special offer 
Add to Cart
  • Recommended application(s)
  • Biological macromolecules, HPLC, Large peptides, Medium-size hydrophilic proteins
  • Storage temperature
  • RT
  • Scope of delivery
  • 1x analytical HPLC column, instruction leaflet, certificate of analysis
  • Hazardous material
  • No
  • Method
  • HPLC, analytical
  • Brand
  • NUCLEOSIL
  • Base material
  • NUCLEOSIL - the standard silica
  • Phase
  • NUCLEOSIL 500-5 C18 PPN
  • USP listing
  • L1
  • Surface chemistry
  • Special octadecyl (C18, ODS) modification
  • Mode
  • Special application or diverse
  • Type
  • EC HPLC column (analytical)
  • Hardware
  • Stainless steel
  • Column length
  • 250 mm
  • Column inner diameter
  • 4 mm
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • 5 µm
  • Eluent in HPLC column
  • Methanol
  • Endcapped
  • No
  • Carbon content
  • Not available or proprietary
  • pH stability
  • 1.0–9.0
  • Pore size
  • 500 Å
  • Specific surface according to BET
  • 35 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 250 bar
MN720252.40 EC HPLC column (analytical), NUCLEOSIL 100-5 C18 PPN, 5 µm, 250x4 mm Special offer 
Add to Cart
  • Recommended application(s)
  • Biological macromolecules, HPLC, Large peptides, Medium-size hydrophilic proteins
  • Storage temperature
  • RT
  • Scope of delivery
  • 1x analytical HPLC column, instruction leaflet, certificate of analysis
  • Hazardous material
  • No
  • Method
  • HPLC, analytical
  • Brand
  • NUCLEOSIL
  • Base material
  • NUCLEOSIL - the standard silica
  • Phase
  • NUCLEOSIL 100-5 C18 PPN
  • USP listing
  • L1
  • Surface chemistry
  • Special octadecyl (C18, ODS) modification
  • Mode
  • Special application or diverse
  • Type
  • EC HPLC column (analytical)
  • Hardware
  • Stainless steel
  • Column length
  • 250 mm
  • Column inner diameter
  • 4 mm
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • 5 µm
  • Eluent in HPLC column
  • Methanol
  • Endcapped
  • No
  • Carbon content
  • Not available or proprietary
  • pH stability
  • 1.0–9.0
  • Pore size
  • 100 Å
  • Specific surface according to BET
  • 350 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 250 bar
MN760001.20 EC HPLC column (analytical), NUCLEODUR 100-5 C18 ec, 5 µm, 125x2 mm Special offer 
Add to Cart
  • Recommended application(s)
  • Aldehydes, Basic, neutral or acidic drugs, Derivatized amino acids, Fat-soluble vitamins, Ketones, Pesticides, Phenolic compounds, Reversed phase, RP applications HPLC
  • Storage temperature
  • RT
  • Scope of delivery
  • 1x analytical HPLC column, instruction leaflet, certificate of analysis
  • Hazardous material
  • No
  • Method
  • HPLC, analytical
  • Brand
  • NUCLEODUR
  • Base material
  • NUCLEODUR - high purity silica
  • Phase
  • NUCLEODUR 100-5 C18 ec
  • USP listing
  • L1
  • Surface chemistry
  • Medium density monomeric octadecyl (C18, ODS) modification
  • Mode
  • Reversed phase (RP)
  • Type
  • EC HPLC column (analytical)
  • Hardware
  • Stainless steel
  • Column length
  • 125 mm
  • Column inner diameter
  • 2 mm
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • 5 µm
  • Eluent in HPLC column
  • Acetonitrile – water
  • Endcapped
  • Yes
  • Carbon content
  • 17.5 %
  • pH stability
  • 1.0–9.0
  • Pore size
  • 110 Å
  • Specific surface according to BET
  • 340 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 600 bar
  • Column volume
  • 0.37 mL
MN760001.30 EC HPLC column (analytical), NUCLEODUR 100-5 C18 ec, 5 µm, 125x3 mm Special offer 
Add to Cart
  • Recommended application(s)
  • Aldehydes, Basic, neutral or acidic drugs, Derivatized amino acids, Fat-soluble vitamins, Ketones, Pesticides, Phenolic compounds, Reversed phase, RP applications HPLC
  • Storage temperature
  • RT
  • Scope of delivery
  • 1x analytical HPLC column, instruction leaflet, certificate of analysis
  • Hazardous material
  • No
  • Method
  • HPLC, analytical
  • Brand
  • NUCLEODUR
  • Base material
  • NUCLEODUR - high purity silica
  • Phase
  • NUCLEODUR 100-5 C18 ec
  • USP listing
  • L1
  • Surface chemistry
  • Medium density monomeric octadecyl (C18, ODS) modification
  • Mode
  • Reversed phase (RP)
  • Type
  • EC HPLC column (analytical)
  • Hardware
  • Stainless steel
  • Column length
  • 125 mm
  • Column inner diameter
  • 3 mm
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • 5 µm
  • Eluent in HPLC column
  • Acetonitrile – water
  • Endcapped
  • Yes
  • Carbon content
  • 17.5 %
  • pH stability
  • 1.0–9.0
  • Pore size
  • 110 Å
  • Specific surface according to BET
  • 340 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 600 bar
  • Column volume
  • 0.87 mL
MN760001.40 EC HPLC column (analytical), NUCLEODUR 100-5 C18 ec, 5 µm, 125x4 mm Special offer 
Add to Cart
  • Recommended application(s)
  • Aldehydes, Basic, neutral or acidic drugs, Derivatized amino acids, Fat-soluble vitamins, Ketones, Pesticides, Phenolic compounds, Reversed phase, RP applications HPLC
  • Storage temperature
  • RT
  • Scope of delivery
  • 1x analytical HPLC column, instruction leaflet, certificate of analysis
  • Hazardous material
  • No
  • Method
  • HPLC, analytical
  • Brand
  • NUCLEODUR
  • Base material
  • NUCLEODUR - high purity silica
  • Phase
  • NUCLEODUR 100-5 C18 ec
  • USP listing
  • L1
  • Surface chemistry
  • Medium density monomeric octadecyl (C18, ODS) modification
  • Mode
  • Reversed phase (RP)
  • Type
  • EC HPLC column (analytical)
  • Hardware
  • Stainless steel
  • Column length
  • 125 mm
  • Column inner diameter
  • 4 mm
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • 5 µm
  • Eluent in HPLC column
  • Acetonitrile – water
  • Endcapped
  • Yes
  • Carbon content
  • 17.5 %
  • pH stability
  • 1.0–9.0
  • Pore size
  • 110 Å
  • Specific surface according to BET
  • 340 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 600 bar
  • Column volume
  • 1.56 mL

Overview

High performance liquid chromatography (HPLC) is part of liquid chromatographic separating processes of substance mixtures and their analysis. At the beginning the technique was also called high pressure liquid chromatography due to the high back pressure of the column. HPLC offers qualitative (identification of substances) and quantitative (concentration determination) analysis by comparison with standard substances. The term HPLC was introduced in the 1970s, for the delineation of the high-performance method to the in the 1930s developed column liquid chromatography (column chromatography). At the beginning of the 21st century the HPLC was complemented by the even more efficient UHPLC (ultra high performance liquid chromatography). Hereby even higher pressures (> 400 bar) result in shorter analysis time and enhanced efficiency enabling a higher sample throughput with smaller sample volumes.


Detailed information of the particular properties of the high-purity silica phases NUCLEODUR, the established standard silica NUCLEOSIL and the modern Core-Shell material NUCLEOSHELL as well as phases for special separations can be found at the equivalent HPLC- and UHPLC-columns.


Each MACHEREY‑NAGEL HPLC / UHPLC column is individually tested according to the most important characteristic parameters in quality control and the results are documented in a certificate of analysis.



Resources