+852-3069 6950
css@gugent.com.hk
 

Stainless steel HPLC columns for analytical or preparative applictions from MACHEREY‑NAGEL are a great choice for your daily labwork.

* NUCLEOSIL HPLC phases have gained wide acceptance as routine chromatographic packings for very different fields of modern chromatography. It is one of the first spherical silicas used in HPLC and is an absolutely reliable choice for routine analyses.

* NUCLEODUR as a state-of-the-art silica is the ideal base material for modern HPLC phases. It is the result of MACHEREY-NAGEL's pioneering research in chromatography for almost 50 years. NUCLEODUR HPLC columns with 1.8 µm particle size for increased separation efficiency are used for UHPLC applications.

* Due to core-shell technology NUCLEOSHELL columns provide highly efficient separation results with a comparably lower back pressure to fully porous materials.

Catalog No. Product Net Price
MN721188.30 EC HPLC guard column (analytical), NUCLEOSIL CHIRAL-1, 5 µm, 4x3 mm Special offer 
Add to Cart
  • Recommended application(s)
  • Guard column, ideal protection for your main column, HPLC
  • Storage temperature
  • RT
  • Scope of delivery
  • 1x analytical HPLC guard column
  • Hazardous material
  • No
  • Method
  • HPLC, analytical
  • Brand
  • NUCLEOSIL
  • Base material
  • NUCLEOSIL - the standard silica
  • Phase
  • NUCLEOSIL CHIRAL-1
  • USP listing
  • L32
  • Surface chemistry
  • L-hydroxyproline – Cu²⁺ complexes (chiral selector) modification
  • Mode
  • Special application or diverse
  • Type
  • EC HPLC guard column (analytical)
  • Hardware
  • Stainless steel
  • Column length
  • 4 mm
  • Column inner diameter
  • 3 mm
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • 5 µm
  • Eluent in HPLC column
  • 0.5 mmol/L copper sulfate solution
  • Endcapped
  • No
  • Carbon content
  • Not available or proprietary
  • pH stability
  • 2.0–8.0
  • Pore size
  • 120 Å
  • Specific surface according to BET
  • 200 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 400 bar
MN721190.30 EC HPLC guard column (analytical), NUCLEOSIL CHIRAL-2/3, 5 µm, 4x3 mm Special offer 
Add to Cart
  • Recommended application(s)
  • Guard column, ideal protection for your main column, HPLC
  • Storage temperature
  • RT
  • Scope of delivery
  • 1x analytical HPLC guard column
  • Hazardous material
  • No
  • Method
  • HPLC, analytical
  • Brand
  • NUCLEOSIL
  • Base material
  • NUCLEOSIL - the standard silica
  • Phase
  • NUCLEOSIL CHIRAL-2/3
  • USP listing
  • L36
  • Surface chemistry
  • Not available or proprietary
  • Mode
  • Special application or diverse
  • Type
  • EC HPLC guard column (analytical)
  • Hardware
  • Stainless steel
  • Column length
  • 4 mm
  • Column inner diameter
  • 3 mm
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • 5 µm
  • Eluent in HPLC column
  • n-heptane – 2-propanol – TFAA (trifluoroacetic acid) (100/0.05/0.05, v/v/v)
  • Endcapped
  • No
  • Carbon content
  • Not available or proprietary
  • pH stability
  • 2.0–8.0
  • Pore size
  • 100 Å
  • Specific surface according to BET
  • 350 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 400 bar
MN721194.30 EC HPLC guard column (analytical), NUCLEOSIL 100-5 C8, 5 µm, 4x3 mm Special offer 
Add to Cart
  • Recommended application(s)
  • Guard column, ideal protection for your main column, HPLC
  • Storage temperature
  • RT
  • Scope of delivery
  • 3x analytical HPLC guard columns
  • Hazardous material
  • No
  • Method
  • HPLC, analytical
  • Brand
  • NUCLEOSIL
  • Base material
  • NUCLEOSIL - the standard silica
  • Phase
  • NUCLEOSIL 100-5 C8
  • USP listing
  • L7
  • Surface chemistry
  • Octyl (C8, RP8, MOS) modification
  • Mode
  • Reversed phase (RP)
  • Type
  • EC HPLC guard column (analytical)
  • Hardware
  • Stainless steel
  • Column length
  • 4 mm
  • Column inner diameter
  • 3 mm
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • 5 µm
  • Eluent in HPLC column
  • Acetonitrile – water
  • Endcapped
  • No
  • Carbon content
  • 8.5 %
  • pH stability
  • 2.0–8.0
  • Pore size
  • 100 Å
  • Specific surface according to BET
  • 350 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 400 bar
MN721196.30 EC HPLC guard column (analytical), NUCLEOSIL 100-3 C18 HD, 3 µm, 4x3 mm Special offer 
Add to Cart
  • Recommended application(s)
  • Guard column, ideal protection for your main column, HPLC
  • Storage temperature
  • RT
  • Scope of delivery
  • 3x analytical HPLC guard columns
  • Hazardous material
  • No
  • Method
  • HPLC, analytical
  • Brand
  • NUCLEOSIL
  • Base material
  • NUCLEOSIL - the standard silica
  • Phase
  • NUCLEOSIL 100-3 C18 HD
  • USP listing
  • L1
  • Surface chemistry
  • High density monomeric octadecyl (C18, ODS) modification
  • Mode
  • Reversed phase (RP)
  • Type
  • EC HPLC guard column (analytical)
  • Hardware
  • Stainless steel
  • Column length
  • 4 mm
  • Column inner diameter
  • 3 mm
  • Particle type
  • Fully porous particle (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • 3 µm
  • Eluent in HPLC column
  • Acetonitrile – water
  • Endcapped
  • Yes
  • Carbon content
  • 20.0 %
  • pH stability
  • 2.0–9.0
  • Pore size
  • 100 Å
  • Specific surface according to BET
  • 350 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 400 bar
MN721402.30 EC HPLC guard column (analytical), RESOLVOSIL BSA-7, 7 µm, 4x3 mm Special offer 
Add to Cart
  • Recommended application(s)
  • Guard column, ideal protection for your main column, HPLC
  • Storage temperature
  • RT
  • Scope of delivery
  • 1x analytical HPLC guard column
  • Hazardous material
  • No
  • Method
  • HPLC, analytical
  • Brand
  • RESOLVOSIL
  • Base material
  • NUCLEOSIL - the standard silica
  • Phase
  • RESOLVOSIL BSA-7
  • USP listing
  • L75
  • Surface chemistry
  • Bovine serum albumin (BSA, chiral selector) modification
  • Mode
  • Special application or diverse
  • Type
  • EC HPLC guard column (analytical)
  • Hardware
  • Stainless steel
  • Column length
  • 4 mm
  • Column inner diameter
  • 3 mm
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • 7 µm
  • Eluent in HPLC column
  • 0.1 mol/L phosphate buffer, pH 7.5 + 2 % 1-propanol
  • Endcapped
  • No
  • Carbon content
  • Not available or proprietary
  • pH stability
  • 5.0–8.0
  • Pore size
  • 300 Å
  • Specific surface according to BET
  • 100 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 400 bar
MN721469.30 EC HPLC guard column (analytical), NUCLEODEX ALPHA-PM, 5 µm, 4x3 mm Special offer 
Add to Cart
  • Recommended application(s)
  • Guard column, ideal protection for your main column, HPLC
  • Storage temperature
  • RT
  • Scope of delivery
  • 1x analytical HPLC guard column
  • Hazardous material
  • No
  • Method
  • HPLC, analytical
  • Brand
  • NUCLEODEX
  • Base material
  • NUCLEOSIL - the standard silica
  • Phase
  • NUCLEODEX ALPHA-PM
  • USP listing
  • Not available or proprietary
  • Surface chemistry
  • Permethylated α-cyclodextrin (chiral selector) modification
  • Mode
  • Special application or diverse
  • Type
  • EC HPLC guard column (analytical)
  • Hardware
  • Stainless steel
  • Column length
  • 4 mm
  • Column inner diameter
  • 3 mm
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • 5 µm
  • Eluent in HPLC column
  • CH₃OH (methanol) – 50 mmol/L phosphate, pH 3 (70/30, v/v)
  • Endcapped
  • No
  • Carbon content
  • Not available or proprietary
  • pH stability
  • 3.0–8.0
  • Pore size
  • 100 Å
  • Specific surface according to BET
  • 350 m²/g
  • Temperature stability (max)
  • 50 °C
  • Pressure stability (max)
  • 400 bar
MN721473.30 EC HPLC guard column (analytical), NUCLEOSIL 50-5 C18 ec, 5 µm, 4x3 mm Special offer 
Add to Cart
  • Recommended application(s)
  • Guard column, ideal protection for your main column, HPLC
  • Storage temperature
  • RT
  • Scope of delivery
  • 3x analytical HPLC guard columns
  • Hazardous material
  • No
  • Method
  • HPLC, analytical
  • Brand
  • NUCLEOSIL
  • Base material
  • NUCLEOSIL - the standard silica
  • Phase
  • NUCLEOSIL 50-5 C18 ec
  • USP listing
  • L1
  • Surface chemistry
  • Octadecyl (C18, ODS) modification, Octadecyl phase (C18, ODS) modification
  • Mode
  • Reversed phase (RP)
  • Type
  • EC HPLC guard column (analytical)
  • Hardware
  • Stainless steel
  • Column length
  • 4 mm
  • Column inner diameter
  • 3 mm
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • 5 µm
  • Eluent in HPLC column
  • Acetonitrile – water
  • Endcapped
  • Yes
  • Carbon content
  • 14.5 %
  • pH stability
  • 2.0–8.0
  • Pore size
  • 50 Å
  • Specific surface according to BET
  • 420 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 400 bar
MN721518.30 EC HPLC guard column (analytical), NUCLEOSIL 100-5, 5 µm, 4x3 mm Special offer 
Add to Cart
  • Recommended application(s)
  • Guard column, ideal protection for your main column, HPLC
  • Storage temperature
  • RT
  • Scope of delivery
  • 3x analytical HPLC guard columns
  • Hazardous material
  • No
  • Method
  • HPLC, analytical
  • Brand
  • NUCLEOSIL
  • Base material
  • NUCLEOSIL - the standard silica
  • Phase
  • NUCLEOSIL 100-5
  • USP listing
  • L3
  • Surface chemistry
  • Unmodified silica gel (SiOH)
  • Mode
  • Normal phase (NP)
  • Type
  • EC HPLC guard column (analytical)
  • Hardware
  • Stainless steel
  • Column length
  • 4 mm
  • Column inner diameter
  • 3 mm
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • 5 µm
  • Eluent in HPLC column
  • n-heptane
  • Endcapped
  • No
  • Carbon content
  • Not available or proprietary
  • pH stability
  • 2.0–8.0
  • Pore size
  • 100 Å
  • Specific surface according to BET
  • 350 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 400 bar
MN721649.30 EC HPLC guard column (analytical), NUCLEOSIL 100-3 C18 Nautilus, 3 µm, 4x3 mm Special offer 
Add to Cart
  • Recommended application(s)
  • Guard column, ideal protection for your main column, HPLC
  • Storage temperature
  • RT
  • Scope of delivery
  • 3x analytical HPLC guard columns
  • Hazardous material
  • No
  • Method
  • HPLC, analytical
  • Brand
  • NUCLEOSIL
  • Base material
  • NUCLEOSIL - the standard silica
  • Phase
  • NUCLEOSIL 100-3 C18 Nautilus
  • USP listing
  • L1, L60
  • Surface chemistry
  • Octadecyl phase (C18, ODS) modification, with embedded polar group (PEG)
  • Mode
  • Reversed phase (RP)
  • Type
  • EC HPLC guard column (analytical)
  • Hardware
  • Stainless steel
  • Column length
  • 4 mm
  • Column inner diameter
  • 3 mm
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • 3 µm
  • Eluent in HPLC column
  • Acetonitrile – water
  • Endcapped
  • Yes
  • Carbon content
  • 16.0 %
  • pH stability
  • 2.0–8.0
  • Pore size
  • 100 Å
  • Specific surface according to BET
  • 350 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 400 bar
MN721916.30 EC HPLC guard column (analytical), NUCLEOSIL 300-5 C4, 5 µm, 4x3 mm Special offer 
Add to Cart
  • Recommended application(s)
  • Guard column, ideal protection for your main column, HPLC
  • Storage temperature
  • RT
  • Scope of delivery
  • 3x analytical HPLC guard columns
  • Hazardous material
  • No
  • Method
  • HPLC, analytical
  • Brand
  • NUCLEOSIL
  • Base material
  • NUCLEOSIL - the standard silica
  • Phase
  • NUCLEOSIL 300-5 C4
  • USP listing
  • L26
  • Surface chemistry
  • Medium density monomeric butyl (C4) wide-pore modification
  • Mode
  • Reversed phase (RP)
  • Type
  • EC HPLC guard column (analytical)
  • Hardware
  • Stainless steel
  • Column length
  • 4 mm
  • Column inner diameter
  • 3 mm
  • Particle type
  • Fully porous particles (FPP)
  • Particle shape
  • Spherical
  • Particle size
  • 5 µm
  • Eluent in HPLC column
  • Acetonitrile – water
  • Endcapped
  • Yes
  • Carbon content
  • 2.0 %
  • pH stability
  • 2.0–8.0
  • Pore size
  • 300 Å
  • Specific surface according to BET
  • 100 m²/g
  • Temperature stability (max)
  • 60 °C
  • Pressure stability (max)
  • 300 bar

Overview

High performance liquid chromatography (HPLC) is part of liquid chromatographic separating processes of substance mixtures and their analysis. At the beginning the technique was also called high pressure liquid chromatography due to the high back pressure of the column. HPLC offers qualitative (identification of substances) and quantitative (concentration determination) analysis by comparison with standard substances. The term HPLC was introduced in the 1970s, for the delineation of the high-performance method to the in the 1930s developed column liquid chromatography (column chromatography). At the beginning of the 21st century the HPLC was complemented by the even more efficient UHPLC (ultra high performance liquid chromatography). Hereby even higher pressures (> 400 bar) result in shorter analysis time and enhanced efficiency enabling a higher sample throughput with smaller sample volumes.


Detailed information of the particular properties of the high-purity silica phases NUCLEODUR, the established standard silica NUCLEOSIL and the modern Core-Shell material NUCLEOSHELL as well as phases for special separations can be found at the equivalent HPLC- and UHPLC-columns.


Each MACHEREY‑NAGEL HPLC / UHPLC column is individually tested according to the most important characteristic parameters in quality control and the results are documented in a certificate of analysis.



Resources