MN761907.20
EC HPLC guard column (analytical), NUCLEODUR C8 Gravity, 5 µm, 4x2 mm
Special offer
Add to Cart
Recommended application(s)
Guard column, ideal protection for your main column, HPLC
Storage temperature
RT
Scope of delivery
3x analytical HPLC guard columns
Hazardous material
No
Method
HPLC, analytical
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR C8 Gravity
USP listing
L7
Surface chemistry
Base deactivated (BDS), High density monomeric octyl (C8, MOS) modification
Mode
Reversed phase (RP)
Type
EC HPLC guard column (analytical)
Hardware
Stainless steel
Column length
4 mm
Column inner diameter
2 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
5 µm
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
11.0 %
pH stability
1.0–11.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
400 bar
MN761907.30
EC HPLC guard column (analytical), NUCLEODUR C8 Gravity, 5 µm, 4x3 mm
Special offer
Add to Cart
Recommended application(s)
Guard column, ideal protection for your main column, HPLC
Storage temperature
RT
Scope of delivery
3x analytical HPLC guard columns
Hazardous material
No
Method
HPLC, analytical
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR C8 Gravity
USP listing
L7
Surface chemistry
Base deactivated (BDS), High density monomeric octyl (C8, MOS) modification
Mode
Reversed phase (RP)
Type
EC HPLC guard column (analytical)
Hardware
Stainless steel
Column length
4 mm
Column inner diameter
3 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
5 µm
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
11.0 %
pH stability
1.0–11.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
400 bar
MN761910.20
EC UHPLC guard column (analytical), NUCLEODUR C18 Isis, 1.8 µm, 4x2 mm
Special offer
Add to Cart
Recommended application(s)
Guard column, ideal protection for your main column, HPLC
Storage temperature
RT
Scope of delivery
3x analytical HPLC guard columns
Hazardous material
No
Method
HPLC/UHPLC, analytical
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR C18 Isis
USP listing
L1
Surface chemistry
High steric selectivity, Nonpolar crosslinked polymeric octadecyl (C18, ODS) modification
Mode
Reversed phase (RP)
Type
EC UHPLC guard column (analytical)
Hardware
Stainless steel
Column length
4 mm
Column inner diameter
2 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
1.8 µm
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
20.0 %
pH stability
1.0–10.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
900 bar
MN761910.30
EC UHPLC guard column (analytical), NUCLEODUR C18 Isis, 1.8 µm, 4x3 mm
Special offer
Add to Cart
Recommended application(s)
Guard column, ideal protection for your main column, HPLC
Storage temperature
RT
Scope of delivery
3x analytical HPLC guard columns
Hazardous material
No
Method
HPLC/UHPLC, analytical
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR C18 Isis
USP listing
L1
Surface chemistry
High steric selectivity, Nonpolar crosslinked polymeric octadecyl (C18, ODS) modification
Mode
Reversed phase (RP)
Type
EC UHPLC guard column (analytical)
Hardware
Stainless steel
Column length
4 mm
Column inner diameter
3 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
1.8 µm
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
20.0 %
pH stability
1.0–10.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
900 bar
MN761911.20
EC HPLC guard column (analytical), NUCLEODUR C18 Isis, 3 µm, 4x2 mm
Special offer
Add to Cart
Recommended application(s)
Guard column, ideal protection for your main column, HPLC
Storage temperature
RT
Scope of delivery
3x analytical HPLC guard columns
Hazardous material
No
Method
HPLC, analytical
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR C18 Isis
USP listing
L1
Surface chemistry
High steric selectivity, Nonpolar crosslinked polymeric octadecyl (C18, ODS) modification
Mode
Reversed phase (RP)
Type
EC HPLC guard column (analytical)
Hardware
Stainless steel
Column length
4 mm
Column inner diameter
2 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
3 µm
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
20.0 %
pH stability
1.0–10.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
600 bar
MN761911.30
EC HPLC guard column (analytical), NUCLEODUR C18 Isis, 3 µm, 4x3 mm
Special offer
Add to Cart
Recommended application(s)
Guard column, ideal protection for your main column, HPLC
Storage temperature
RT
Scope of delivery
3x analytical HPLC guard columns
Hazardous material
No
Method
HPLC, analytical
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR C18 Isis
USP listing
L1
Surface chemistry
High steric selectivity, Nonpolar crosslinked polymeric octadecyl (C18, ODS) modification
Mode
Reversed phase (RP)
Type
EC HPLC guard column (analytical)
Hardware
Stainless steel
Column length
4 mm
Column inner diameter
3 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
3 µm
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
20.0 %
pH stability
1.0–10.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
600 bar
MN761912.20
EC HPLC guard column (analytical), NUCLEODUR C18 Isis, 5 µm, 4x2 mm
Special offer
Add to Cart
Recommended application(s)
Guard column, ideal protection for your main column, HPLC
Storage temperature
RT
Scope of delivery
3x analytical HPLC guard columns
Hazardous material
No
Method
HPLC, analytical
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR C18 Isis
USP listing
L1
Surface chemistry
High steric selectivity, Nonpolar crosslinked polymeric octadecyl (C18, ODS) modification
Mode
Reversed phase (RP)
Type
EC HPLC guard column (analytical)
Hardware
Stainless steel
Column length
4 mm
Column inner diameter
2 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
5 µm
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
20.0 %
pH stability
1.0–10.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
600 bar
MN761912.30
EC HPLC guard column (analytical), NUCLEODUR C18 Isis, 5 µm, 4x3 mm
Special offer
Add to Cart
Recommended application(s)
Guard column, ideal protection for your main column, HPLC
Storage temperature
RT
Scope of delivery
3x analytical HPLC guard columns
Hazardous material
No
Method
HPLC, analytical
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR C18 Isis
USP listing
L1
Surface chemistry
High steric selectivity, Nonpolar crosslinked polymeric octadecyl (C18, ODS) modification
Mode
Reversed phase (RP)
Type
EC HPLC guard column (analytical)
Hardware
Stainless steel
Column length
4 mm
Column inner diameter
3 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
5 µm
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
20.0 %
pH stability
1.0–10.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
600 bar
MN761915.20
EC UHPLC guard column (analytical), NUCLEODUR C18 Pyramid, 1.8 µm, 4x2 mm
Special offer
Add to Cart
Recommended application(s)
Guard column, ideal protection for your main column, HPLC
Storage temperature
RT
Scope of delivery
3x analytical HPLC guard columns
Hazardous material
No
Method
HPLC/UHPLC, analytical
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR C18 Pyramid
USP listing
L1
Surface chemistry
Octadecyl (C18, ODS) modification, Polar endcapping
Mode
Reversed phase (RP)
Type
EC UHPLC guard column (analytical)
Hardware
Stainless steel
Column length
4 mm
Column inner diameter
2 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
1.8 µm
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
14.0 %
pH stability
1.0–9.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
900 bar
MN761915.30
EC UHPLC guard column (analytical), NUCLEODUR C18 Pyramid, 1.8 µm, 4x3 mm
Special offer
Add to Cart
Recommended application(s)
Guard column, ideal protection for your main column, HPLC
Storage temperature
RT
Scope of delivery
3x analytical HPLC guard columns
Hazardous material
No
Method
HPLC/UHPLC, analytical
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR C18 Pyramid
USP listing
L1
Surface chemistry
Octadecyl (C18, ODS) modification, Polar endcapping
Mode
Reversed phase (RP)
Type
EC UHPLC guard column (analytical)
Hardware
Stainless steel
Column length
4 mm
Column inner diameter
3 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
1.8 µm
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
14.0 %
pH stability
1.0–9.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
900 bar