+852-3069 6950
css@gugent.com.hk
 

Agilent Inductively Coupled Plasma Mass Spectrometry (ICP-MS) is available in single quadrupole and triple quadrupole configurations. Our single quadrupole ICP-MS address the range of typical ICP-MS measurements from routine, regulated analysis to advanced research and demanding applications. Our triple quadrupole ICP-MS will give you the confidence of knowing you can resolve problematic interferences – even in your most difficult samples – delivering results you know you can trust.

Catalog No. Product Net Price
G3139-65106 Nebulizer, MicroFlow, inert PFA, self-aspirates at 20-50 μL/min. For use without Agilent integrated autosampler (I-AS), for low sample volume trace analysis and hydrofluoric acid (HF), self-aspirates or can be used with instrument peristaltic pump 2327 
Add to Cart
  • UNSPSC Code
  • 41115411
  • Autosampler Compatibility
  • None
  • Chemical Compatibility
  • Aqueous HF acid Organic solvents Strong acids
  • Gas Connector
  • Threaded connector
  • Material
  • PFA
  • Name
  • MicroFlow
  • Nebulizer Sample Particle Size Tolerance
  • 40 µm
  • Notes
  • Low flow rate self-aspirating inert nebulizer, not for use with the integrated autosampler (I-AS)
  • Sample Connection
  • Direct
  • Sample Uptake Rate
  • 50
  • Self Aspirating
  • Yes,
  • Type
  • Concentric
G3161-80000 Nebulizer, Mira Mist, PTFE, for high TDS applications with HF and Organic Solvent, suitable for all Agilent ICP-MS series. Enhanced parallel path nebulizer gives high salts and TDS capability. Suitable for all acids, including HF, and organic solvents. D 1461 
Add to Cart
  • UNSPSC Code
  • 41115411
  • Autosampler Compatibility
  • I-AS Other SPS 3 SPS 4
  • Chemical Compatibility
  • Aqueous HF acid Organic solvents Strong acids
  • Gas Connector
  • Threaded connector
  • Material
  • PTFE
  • Name
  • MiraMist
  • Nebulizer Sample Particle Size Tolerance
  • 150 µm
  • Notes
  • PTFE
  • Sample Connection
  • Threaded connector
  • Sample Uptake Rate
  • 2500
  • Self Aspirating
  • No
  • Type
  • Parallel path
G3285-80001 Nebulizer, C-Flow with Agilent I-AS probe, inert PFA, self-aspirates at 200 μL/min. For use with Agilent integrated autosampler (I-AS), for trace analysis and hydrofluoric acid (HF), self-aspirates with integrated sample probe. Optional for all Agilent IC 1971 
Add to Cart
  • UNSPSC Code
  • 41115411
  • Autosampler Compatibility
  • I-AS
  • Chemical Compatibility
  • Aqueous HF acid Organic solvents Strong acids
  • Gas Connector
  • Threaded connector
  • Material
  • PFA
  • Name
  • C-Flow
  • Nebulizer Sample Particle Size Tolerance
  • 40 µm
  • Notes
  • All PFA nebulizer recommended for ultratrace analysisAlternative to the MicroFlow nebulizer Alternative to the MicroFlow nebulizer -->
  • Sample Connection
  • Direct
  • Sample Uptake Rate
  • 200
  • Self Aspirating
  • Yes,
  • Type
  • Concentric
AGIL9910057400 V-groove nebulizer kit, inert, for the Sturman-Masters spray chamber. Recommended for samples containing hydrofluoric acid, fusions, slurries, or >20% TDS.Includes nebulizer body, sample capillary, nebulizer gas connector, cleaning wire. 1016 
Add to Cart
  • UNSPSC Code
  • 41115411
  • Chemical Compatibility
  • Aqueous HF acid Organic solvents
  • Gas Connector
  • Quick release
  • Material
  • PEEK
  • Name
  • V-Groove
  • Nebulizer Sample Particle Size Tolerance
  • 350 µm
  • Notes
  • Samples with hydrofluoric acid, fusions, slurries, or >20 % TDS 20 % TDS -->
  • Other Features
  • Only compatible with Sturman-Master spray chamber
  • Sample Connection
  • Direct
  • Self Aspirating
  • Yes
  • TDS Handling Capability
  • 25 % TDS
  • Type
  • V-groove
G8010-60293 OneNeb series 2 inert concentric nebulizer. Recommended for routine analysis of samples up to 25% TDS; inert construction makes it suitable for most solution types. Includes replaceable sample capillary/connector assembly, quick release connector for nebu 948 
Add to Cart
  • UNSPSC Code
  • 41113000
  • Chemical Compatibility
  • Aqueous HF acid Organic solvents
  • Compatible with Advanced Valve System (AVS)
  • No
  • Gas Connector
  • Quick release
  • Material
  • PEEK
  • Name
  • OneNeb
  • Nebulizer Sample Particle Size Tolerance
  • 150 µm
  • Notes
  • Ideal for routine analysis of samples up to 25 % TDS with good precision and better sensitivity than a SeaSpray; inert construction makes it suitable for most solution types
  • Other Features
  • Not suitable for use with SVS/AVS
  • Sample Connection
  • Direct
  • Self Aspirating
  • No
  • TDS Handling Capability
  • 25 % TDS
  • Type
  • Flow-blurring
G8010-60345 Sample inlet fitting, for OneNeb Series 2 nebulizer. Includes capillary connector with captive sample capillary tubing 0.5 mm id, 1/16 inch od, 750 mm long 86 
Add to Cart
  • Inner Diameter (ID)
  • 0.5 mm
  • Length
  • 750 mm
  • UNSPSC Code
  • 41113000
  • Notes
  • Suitable for the OneNeb Series 2 nebulizer
  • Outer Diameter (OD)
  • 1.59 mm
  • Where Used
  • Nebulizer
G3285-80016 Obsolete. No replacement recommendation. Inert sample introduction kit, 1.5 mm id sapphire injector tube, for Agilent 7500 ICP-MS, replaces standard sample introduction system with an inert system for volatile organic samples, requires but does not includ Special offer 
Add to Cart
  • UNSPSC Code
  • 41115411
G4912-68000 PFA Inert sample introduction kit with 2.5 mm id sapphire injector, for aqueous samples containing HF. Suits Agilent 7700, 7800, 7850, 7900, 8800, 8900 ICP-MS with PFA inert kit. Not compatible with HMI / UHMI aerosol gas dilution - order connector with g 5692 
Add to Cart
  • UNSPSC Code
  • 41115411
G4912-68001 PFA Inert sample introduction kit with 2.5 mm id platinum injector, for aqueous samples containing HF. Suits Agilent 7700, 7800, 7850, 7900, 8800, 8900 ICP-MS with PFA inert kit. Not compatible with HMI / UHMI aerosol gas dilution - order connector with g 8503 
Add to Cart
  • UNSPSC Code
  • 41115411
G4912-68002 PFA Inert sample introduction kit with 1.5 mm id sapphire injector, for organic samples. Suits Agilent 7700, 7800, 7850, 7900, 8800, 8900 ICP-MS with PFA inert kit. Not compatible with HMI / UHMI aerosol gas dilution. If make up and option gas are both re 5983 
Add to Cart
  • UNSPSC Code
  • 41115411

Overview

ICP-MS system operates with an ICP-MS Nebulizer, in which a high velocity Argon gas stream meets a liquid stream causing filmwise breakup of the solution into a fine aerosol. The aerosol particle size should ideally be sub-10µm with a narrow particle size distribution to achieve efficient atomization and ionization. Agilent offers a comprehensive range of ICP-MS nebulizers and supplies to solve any ICP-MS analysis challenge.

The portfolio includes standard glass concentric nebulizer (MicroMist), quartz and inert PFA nebulizers (MicroFlow and C-Flow), as well as robust Mira Mist PEEK or PTFE for high TDS samples and low-flow self-aspirating or total consumption nebulizers for your clinical or limited volume samples. ICP-MS nebulizer support is provided with a full range of accessories for all models including nebulizer cleaning tools.


The ICP torch is used to form, shape, and sustain an argon plasma which atomizes and ionizes the sample aerosol. Agilent ICP-MS Torches with Shield Torch System (STS) provide precise ion energy control, ensuring high sensitivity and stability, even in cool plasma mode for effective interference removal (ArO+).

Our portfolio is comprised of a wide range of ICP torches for your specific ICP-MS configuration. One-piece quartz torches offer the best stability and ease of use. The large 2.5mm injector on the standard torch gives maximum robustness and lowest matrix interferences for the best plasma stability. Single-piece torches with narrow bore injectors (1.0mm or 1.5 mm) are designed for use with organic solvents, to reduce plasma loading and improve plasma stability. Optional semi-demountable quartz torches with removable platinum or sapphire injectors are also available for use with the PFA inert sample introduction kit.


Resources