+852-3069 6950
css@gugent.com.hk
 

Agilent Inductively Coupled Plasma Mass Spectrometry (ICP-MS) is available in single quadrupole and triple quadrupole configurations. Our single quadrupole ICP-MS address the range of typical ICP-MS measurements from routine, regulated analysis to advanced research and demanding applications. Our triple quadrupole ICP-MS will give you the confidence of knowing you can resolve problematic interferences – even in your most difficult samples – delivering results you know you can trust.

Catalog No. Product Net Price
G3160-80041 I-AS autosampler needle/probe holder 97 
Add to Cart
  • UNSPSC Code
  • 41115411
G3160-80060 Sample Tray A for Agilent Integrated Autosampler (I-AS), with 89 positions for 6 mL polypropylene vials. Polypropylene (PP) sample rack. Order 6 mL PP vials (G3160-65303) separately. Ideal for use in semi-conductor applications. 849 
Add to Cart
  • UNSPSC Code
  • 41115411
  • Autosampler Compatibility
  • I-AS
  • Component Type
  • Rack
  • Nominal Tube Volume
  • 6 mL
  • Number Tubes Held
  • 89
G3160-80061 Sample Tray B for Agilent Integrated Autosampler (I-AS), with 53 positions for 18 mL polypropylene vials. Polypropylene (PP) sample rack. Order 18 mL PP vials (G3160-65304) separately. Ideal for use in semi-conductor applications. 850 
Add to Cart
  • UNSPSC Code
  • 41115411
  • Autosampler Compatibility
  • I-AS
  • Component Type
  • Rack
  • Nominal Tube Volume
  • 18 mL
  • Number Tubes Held
  • 53
G3160-80062 Sample Tray C for Agilent Integrated Autosampler (I-AS), with 18 positions for 50 mL polypropylene vials. Polypropylene (PP) sample rack. Order 50 mL PP vials (G3160-65305) separately. Ideal for use in semi-conductor applications. 751 
Add to Cart
  • UNSPSC Code
  • 41115411
  • Autosampler Compatibility
  • I-AS
  • Component Type
  • Rack
  • Nominal Tube Volume
  • 50 mL
  • Number Tubes Held
  • 18
G3160-80063 Sample Tray D for Agilent Integrated Autosampler (I-AS), with 79 positions for 1.5 or 2 mL and 10 positions for 18 mL polypropylene vials. Polypropylene (PP) sample rack. Order 1.5 or 2 mL PP vials (G3160-65315) and 18 mL PP vials (G3160-65304) separately 850 
Add to Cart
  • UNSPSC Code
  • 41115411
  • Autosampler Compatibility
  • I-AS
  • Component Type
  • Rack
  • Nominal Tube Volume
  • 2 mL
  • Number Tubes Held
  • 89
G3160-80064 Sample Tray E for Agilent Integrated Autosampler (I-AS), with 79 positions for 6 mL and 10 positions for 18 mL polypropylene vials. Polypropylene (PP) sample rack. Order 6 mL PP vials (G3160-65303) and 18 mL PP vials (G3160-65304) separately. Ideal for u 849 
Add to Cart
  • UNSPSC Code
  • 41115411
  • Autosampler Compatibility
  • I-AS
  • Component Type
  • Rack
  • Nominal Tube Volume
  • 6 mL
  • Number Tubes Held
  • 89
G3160-80065 Sample Tray F for Agilent Integrated Autosampler (I-AS), with 15 positions for 48 mm od vials. Polypropylene (PP) sample rack. Order suitable 48 mm od x 55 mm tall vials seperately. Ideal for use in semi-conductor applications. 847 
Add to Cart
  • UNSPSC Code
  • 41115411
  • Autosampler Compatibility
  • I-AS
  • Component Type
  • Rack
  • Number Tubes Held
  • 15
  • Tube Height
  • 55 mm
  • Tube Max Outer Diameter
  • 48 mm
G3160-80066 Sample Tray G for Agilent integrated autosampler (I-AS), with 28 positions for 20 mL PFA vials up to 28 mm od x 58 mm tall. Polypropylene (PP) sample rack. Order 20 mL PFA vials up to 28 mm od x 58 mm tall seperately. Ideal for use in semi-conductor appl 845 
Add to Cart
  • UNSPSC Code
  • 41113000
  • Autosampler Compatibility
  • I-AS
  • Component Type
  • Rack
  • Nominal Tube Volume
  • 20 mL
  • Number Tubes Held
  • 28
  • Tube Height
  • 58 mm
  • Tube Max Outer Diameter
  • 28 mm
G3160-80200 I-AS autosampler Serial-USB converter cable 177 
Add to Cart
  • UNSPSC Code
  • 41115411
G3280-01507 Interface wrench for Sampling cone for Agilent ICP-MS. Used to remove tightly bound sampler cone, suitable for 7700, 7800, 7850, 7900, 8800, 8900 63 
Add to Cart
  • UNSPSC Code
  • 41115411
  • Tool Type
  • Wrench
  • Where Used
  • Interface cone removal

Overview

ICP-MS system operates with an ICP-MS Nebulizer, in which a high velocity Argon gas stream meets a liquid stream causing filmwise breakup of the solution into a fine aerosol. The aerosol particle size should ideally be sub-10µm with a narrow particle size distribution to achieve efficient atomization and ionization. Agilent offers a comprehensive range of ICP-MS nebulizers and supplies to solve any ICP-MS analysis challenge.

The portfolio includes standard glass concentric nebulizer (MicroMist), quartz and inert PFA nebulizers (MicroFlow and C-Flow), as well as robust Mira Mist PEEK or PTFE for high TDS samples and low-flow self-aspirating or total consumption nebulizers for your clinical or limited volume samples. ICP-MS nebulizer support is provided with a full range of accessories for all models including nebulizer cleaning tools.


The ICP torch is used to form, shape, and sustain an argon plasma which atomizes and ionizes the sample aerosol. Agilent ICP-MS Torches with Shield Torch System (STS) provide precise ion energy control, ensuring high sensitivity and stability, even in cool plasma mode for effective interference removal (ArO+).

Our portfolio is comprised of a wide range of ICP torches for your specific ICP-MS configuration. One-piece quartz torches offer the best stability and ease of use. The large 2.5mm injector on the standard torch gives maximum robustness and lowest matrix interferences for the best plasma stability. Single-piece torches with narrow bore injectors (1.0mm or 1.5 mm) are designed for use with organic solvents, to reduce plasma loading and improve plasma stability. Optional semi-demountable quartz torches with removable platinum or sapphire injectors are also available for use with the PFA inert sample introduction kit.


Resources