Water or air, measure H2S where it matters – right at the source.
Meet the new GS1440 and GS1440EX hydrogen sulfide sensors from Hach. Whether in water or air, you will have the direct H2S measurement you need to optimize your H2S treatment process and proactively control H2S before it causes issues.
Low alarm point, low alarm point deadband, high alarm point, high alarm point deadband, off delay, and on delay
Analog Output Functional Mode
PID, high/low phasing, setpoint, deadband, overfeed timer, off delay, on delay
Certifications
North American Certifications:cTUVus to UL 61010A-1 and CSA C22.2 No. 1010.1FCC ID QIPMC56 / IC ID 267W-MC56European Certifications:CE per 73/23/EEC and 89/336/EECTUV-GS to EN 61010-1EN 61326 Amd's 1 & 2
Communication Capabilities
Modbus 485
Display
1/4 inch VGA graphical backlit TFT color Glas/Glas-Touch screen, high resistance, 320 x 240 pixels 320 x 240 pixels
Enclosure Rating
IP65
Inputs
Up to 12 analogue 0-20 mA, maximum impedance 500 Ohms per probe module. Additional inputs are available with additional probe modules.
Material Enclosures
ABS (display module) and metal (probe module) enclosure with corrosion resistant finish
CE approved (with all sensor types). Listed for use in general locations to UL and CSA safety standards by ETL (with all sensor types).Certain AC mains powered models are listed for use in general safety locations to UL and CSA safety standards by Underwriters Laboratories (with all sensor types).
Conduit Openings
½" NPT conduit
Dimensions
½ DIN - 144 x 144 x 192 mm (5.7 x 5.7 x 7.6 in.)
Display
None
Enclosure Rating
NEMA 4X/IP66 metal enclosure with a corrosion-resistant finish
LAN version: Two Ethernet connectors (10/100 Mbps), switch function, M12 female D-coding connector.Cellular version: SIM card holder (3G/4G).The type of connection is dependent on controller configuration.
Operating Temperature Range
LAN version: -20 - 60 °C (-4 - 140 °F)Cellular version: -20 - 55 °C (-4 - 131 °F)
Pollution Degree
2
Power Requirements (Voltage)
100 - 240 VAC
Protection Class
I, connected to protective earth
Relays
High voltage:Two relays (SPDT)Maximum switching voltage: 250 VACMaximum switching current: 5 A (resistive only load)Maximum switching power: 1250 VA, 125 W (resistive only load)Wire gauge: 0.75 to 2.5 mm2 (18 to 12 AWG)Low voltage:Four relays on each low voltage relay module
CE approved (with all sensor types). Listed for use in general locations to UL and CSA safety standards by ETL (with all sensor types).Certain AC mains powered models are listed for use in general safety locations to UL and CSA safety standards by Underwriters Laboratories (with all sensor types).
Conduit Openings
½" NPT conduit
Dimensions
½ DIN - 144 x 144 x 192 mm (5.7 x 5.7 x 7.6 in.)
Display
None
Enclosure Rating
NEMA 4X/IP66 metal enclosure with a corrosion-resistant finish
LAN version: Two Ethernet connectors (10/100 Mbps), switch function, M12 female D-coding connector.Cellular version: SIM card holder (3G/4G).The type of connection is dependent on controller configuration.
Operating Temperature Range
LAN version: -20 - 60 °C (-4 - 140 °F)Cellular version: -20 - 55 °C (-4 - 131 °F)
Outputs
5x mA Output
Pollution Degree
2
Protection Class
I, connected to protective earth
Relays
High voltage:Two relays (SPDT)Maximum switching voltage: 250 VACMaximum switching current: 5 A (resistive only load)Maximum switching power: 1250 VA, 125 W (resistive only load)Wire gauge: 0.75 to 2.5 mm2 (18 to 12 AWG)Low voltage:Four relays on each low voltage relay module