We have developed a unique portfolio of consumables, each adapted to the different feed water quality requirements and to your various applications. To maintain your water system’s performance, it’s critical to replace your purification cartridges on time and with genuine ISO 9001-certified parts.

Catalog No. Product Net Price
MSP000812 Durapore® Cartridge Filter 10 in. 0.22 µm Code 7 13187 
Add to Cart
  • Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Bacterial Retention
  • Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
  • Cartridge Code
  • Code 7 (2-226) O-rings w/locking-tabs
  • Cartridge Nominal Length
  • 10 in. (25 cm)
  • Catalogue Number
  • MSP000812
  • Chemistry
  • Polyvinylidene Fluoride (PVDF)
  • Device Configuration
  • Cartridge
  • Device Size
  • 10 in.
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 20 mg per 10-inch cartridge after 24 hours in water at controlled room temperature.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Length
  • 10 in. (25 cm)
  • Material Size
  • 48
  • Media
  • Durapore®
  • Non-Fiber Releasing
  • This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Pore Size
  • 0.22 µm
  • Sterility
  • Other
  • Trade Name
  • Durapore®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Wettability
  • Hydrophilic
P2C010V05 Pellicon® 2 Cassette with Ultracel® 10 kDa Membrane, V screen, 0.5 m² 2161 
Add to Cart
  • Catalogue Number
  • P2C010V05
  • Chemistry
  • Composite Regenerated Cellulose (CRC)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene and Polysulfone end cap
  • Filter Code
  • PLCGC
  • Filter Type
  • Ultrafiltration
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Height
  • 2.16 cm (0.85 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 20.6 cm (8.1 in)
  • Material Size
  • 1
  • Maximum Operating Temperature
  • 0 - 30°C
  • Maximum Transmembrane Pressure
  • Forward: 3.4 bar (50 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
  • Media
  • Ultracel®
  • Membrane Area
  • 0.5 m²
  • NMWL
  • 10 kDa
  • pH Range
  • pH2 – pH13
  • Recirculation Rate
  • 7 to 10 L/min/m²
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type V screen (open channel)
  • Trade Name
  • Pellicon®
  • Width
  • 17.8 cm (7.0 in.)
P2C010V05 Pellicon® 2 Cassette with Ultracel® 10 kDa Membrane, V screen, 0.5 m² 2161 
Add to Cart
  • Catalogue Number
  • P2C010V05
  • Chemistry
  • Composite Regenerated Cellulose (CRC)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene and Polysulfone end cap
  • Filter Code
  • PLCGC
  • Filter Type
  • Ultrafiltration
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Height
  • 2.16 cm (0.85 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 20.6 cm (8.1 in)
  • Material Size
  • 1
  • Maximum Operating Temperature
  • 0 - 30°C
  • Maximum Transmembrane Pressure
  • Forward: 3.4 bar (50 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
  • Media
  • Ultracel®
  • Membrane Area
  • 0.5 m²
  • NMWL
  • 10 kDa
  • pH Range
  • pH2 – pH13
  • Recirculation Rate
  • 7 to 10 L/min/m²
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type V screen (open channel)
  • Trade Name
  • Pellicon®
  • Width
  • 17.8 cm (7.0 in.)
P2C030V05 Pellicon® 2 Cassette with Ultracel® 30 kDa Membrane, V screen, 0.5 m² 2161 
Add to Cart
  • Catalogue Number
  • P2C030V05
  • Chemistry
  • Composite Regenerated Cellulose (CRC)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene and Polysulfone end cap
  • Filter Code
  • PLCTK
  • Filter Type
  • Ultrafiltration
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Height
  • 2.16 cm (0.85 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 20.6 cm (8.1 in)
  • Material Size
  • 1
  • Maximum Operating Temperature
  • 0 - 30°C
  • Maximum Transmembrane Pressure
  • Forward: 3.4 bar (50 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
  • Media
  • Ultracel®
  • Membrane Area
  • 0.5 m²
  • NMWL
  • 30 kDa
  • pH Range
  • pH2 – pH13
  • Recirculation Rate
  • 7 to 10 L/min/m²
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type V screen (open channel)
  • Trade Name
  • Pellicon®
  • Width
  • 17.8 cm (7.0 in.)
P2C030V05 Pellicon® 2 Cassette with Ultracel® 30 kDa Membrane, V screen, 0.5 m² 2161 
Add to Cart
  • Catalogue Number
  • P2C030V05
  • Chemistry
  • Composite Regenerated Cellulose (CRC)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene and Polysulfone end cap
  • Filter Code
  • PLCTK
  • Filter Type
  • Ultrafiltration
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Height
  • 2.16 cm (0.85 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 20.6 cm (8.1 in)
  • Material Size
  • 1
  • Maximum Operating Temperature
  • 0 - 30°C
  • Maximum Transmembrane Pressure
  • Forward: 3.4 bar (50 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
  • Media
  • Ultracel®
  • Membrane Area
  • 0.5 m²
  • NMWL
  • 30 kDa
  • pH Range
  • pH2 – pH13
  • Recirculation Rate
  • 7 to 10 L/min/m²
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type V screen (open channel)
  • Trade Name
  • Pellicon®
  • Width
  • 17.8 cm (7.0 in.)
P2PLGCC05 Pellicon® 2 47 0.5 m² 2161 
Add to Cart
  • Catalogue Number
  • P2PLGCC05
  • Chemistry
  • Regenerated Cellulose (RC)
  • Device Configuration
  • Cassette
  • Device Size
  • 0.5 m²
  • Filtration Area
  • 0.5 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Material Size
  • 1
  • Media
  • Biomax®
  • Membrane Area
  • 0.5 m²
  • NMWL
  • 10 kDa
  • Screen Type
  • Type C screen (coarse screen)
P2C005C05 Pellicon® 2 Cassette with Ultracel® 5 kDa Membrane, C screen, 0.5 m² 2168 
Add to Cart
  • Catalogue Number
  • P2C005C05
  • Chemistry
  • Composite Regenerated Cellulose (CRC)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • PLCCC
  • Filter Type
  • Ultrafiltration
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Height
  • 1.5 cm (0.6 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 20.6 cm (8.1 in)
  • Material Size
  • 1
  • Maximum Operating Temperature
  • 0 - 30°C
  • Maximum Transmembrane Pressure
  • Forward: 3.4 bar (50 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
  • Media
  • Ultracel®
  • Membrane Area
  • 0.5 m²
  • NMWL
  • 5 kDa
  • pH Range
  • pH2 – pH13
  • Recirculation Rate
  • 4 to 7 L/min/m²
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type C screen (coarse screen)
  • Trade Name
  • Pellicon®
  • Width
  • 17.8 cm (7.0 in.)
P2C005C05 Pellicon® 2 Cassette with Ultracel® 5 kDa Membrane, C screen, 0.5 m² 2168 
Add to Cart
  • Catalogue Number
  • P2C005C05
  • Chemistry
  • Composite Regenerated Cellulose (CRC)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • PLCCC
  • Filter Type
  • Ultrafiltration
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Height
  • 1.5 cm (0.6 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 20.6 cm (8.1 in)
  • Material Size
  • 1
  • Maximum Operating Temperature
  • 0 - 30°C
  • Maximum Transmembrane Pressure
  • Forward: 3.4 bar (50 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
  • Media
  • Ultracel®
  • Membrane Area
  • 0.5 m²
  • NMWL
  • 5 kDa
  • pH Range
  • pH2 – pH13
  • Recirculation Rate
  • 4 to 7 L/min/m²
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type C screen (coarse screen)
  • Trade Name
  • Pellicon®
  • Width
  • 17.8 cm (7.0 in.)
P2PLBCC05 Pellicon 2 Cassette Ultrafiltration Module PLBC C 0.5 m2 2168 
Add to Cart
  • Catalogue Number
  • P2PLBCC05
  • Chemistry
  • Regenerated Cellulose (RC)
  • Device Configuration
  • Cassette
  • Device Size
  • 0.5 m²
  • Filter Code
  • PLBC
  • Filter Type
  • Ultrafiltration
  • Filtration Area
  • 0.5 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Height
  • 1.5 cm (0.6 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 21 cm (8.3 in.)
  • Material Size
  • 1
  • Maximum Transmembrane Pressure
  • 3.5 bar (50 psig) @ 30 °C
  • Media
  • Ultracel®
  • Membrane Area
  • 0.5 m²
  • NMWL
  • 3 kDa
  • Recirculation Rate
  • 5–35 L/min @ 0.4 bar (6 psi)
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type C screen (coarse screen)
  • Trade Name
  • Pellicon®
  • Width
  • 17.8 cm (7.0 in.)
SF100300J SUS Filter 5Layered Mesh 10 µmCode 0 30 in. 2171 
Add to Cart
  • Availability by Geography
  • Available for sale in Japan only
  • Cartridge Code
  • Code 0 (2-222) O-rings
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • SF100300J
  • Chemistry
  • Stainless Steel
  • Device Configuration
  • Cartridge
  • Format
  • Single Layer
  • Length
  • 30 in. (75 cm)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 686 bar
  • Maximum Inlet Pressure, bar (psi)
  • 686 kPa (40° C)
  • Nominal Pore Size
  • 10.0 µm
  • Pore Size
  • 10.0 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • Multiple Steam Sterilizable
  • Trade Name
  • SUS Filter

Overview

Analytical Sample Preparation Membrane Filtration Devices


Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.


Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.


Filter Membranes

Millex® Syringe Filters

Filtration Holders & Accessories



Resources