+852-3069 6950
css@gugent.com.hk
 

We have developed a unique portfolio of consumables, each adapted to the different feed water quality requirements and to your various applications. To maintain your water system’s performance, it’s critical to replace your purification cartridges on time and with genuine ISO 9001-certified parts.

Catalog No. Product Net Price
P2C010V20 Pellicon® 2 Maxi Cassette with Ultracel® 10 kDa Membrane, V screen, 2 m² 8312 
Add to Cart
  • Catalogue Number
  • P2C010V20
  • Chemistry
  • Composite Regenerated Cellulose (CRC)
  • Device Configuration
  • Maxi Cassette
  • Device Material
  • Polypropylene and Polysulfone end cap
  • Filter Code
  • PLCGC
  • Filter Type
  • Ultrafiltration
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Height
  • 9.0 cm (3.5 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 20.6 cm (8.1 in)
  • Material Size
  • 1
  • Maximum Operating Temperature
  • 0 - 30°C
  • Maximum Transmembrane Pressure
  • Forward: 3.4 bar (50 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
  • Media
  • Ultracel®
  • Membrane Area
  • 2 m²
  • NMWL
  • 10 kDa
  • pH Range
  • pH2 – pH13
  • Recirculation Rate
  • 7 to 10 L/min/m²
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type V screen (open channel)
  • Trade Name
  • Pellicon®
  • Width
  • 17.8 cm (7.0 in.)
P2C010V20 Pellicon® 2 Maxi Cassette with Ultracel® 10 kDa Membrane, V screen, 2 m² 8312 
Add to Cart
  • Catalogue Number
  • P2C010V20
  • Chemistry
  • Composite Regenerated Cellulose (CRC)
  • Device Configuration
  • Maxi Cassette
  • Device Material
  • Polypropylene and Polysulfone end cap
  • Filter Code
  • PLCGC
  • Filter Type
  • Ultrafiltration
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Height
  • 9.0 cm (3.5 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 20.6 cm (8.1 in)
  • Material Size
  • 1
  • Maximum Operating Temperature
  • 0 - 30°C
  • Maximum Transmembrane Pressure
  • Forward: 3.4 bar (50 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
  • Media
  • Ultracel®
  • Membrane Area
  • 2 m²
  • NMWL
  • 10 kDa
  • pH Range
  • pH2 – pH13
  • Recirculation Rate
  • 7 to 10 L/min/m²
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type V screen (open channel)
  • Trade Name
  • Pellicon®
  • Width
  • 17.8 cm (7.0 in.)
P2C030V20 Pellicon® 2 Maxi Cassette with Ultracel® 30 kDa Membrane, V screen, 2 m² 8312 
Add to Cart
  • Catalogue Number
  • P2C030V20
  • Chemistry
  • Composite Regenerated Cellulose (CRC)
  • Device Configuration
  • Maxi Cassette
  • Device Material
  • Polypropylene and Polysulfone end cap
  • Filter Code
  • PLCTK
  • Filter Type
  • Ultrafiltration
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 20.6 cm (8.1 in)
  • Material Size
  • 1
  • Maximum Operating Temperature
  • 0 - 30°C
  • Maximum Transmembrane Pressure
  • Forward: 3.4 bar (50 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
  • Media
  • Ultracel®
  • Membrane Area
  • 2 m²
  • NMWL
  • 30 kDa
  • Recirculation Rate
  • 7 to 10 L/min/m²
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type V screen (open channel)
  • Trade Name
  • Pellicon®
  • Width
  • 17.8 cm (7.0 in.)
P2PLACC25 Pellicon 2 Maxi Ultrafiltration Module PLAC C 2.5 m2 8390 
Add to Cart
  • Catalogue Number
  • P2PLACC25
  • Chemistry
  • Regenerated Cellulose (RC)
  • Device Configuration
  • Maxi Cassette
  • Device Size
  • 2.5 m²
  • Filter Code
  • PLAC
  • Filter Type
  • Ultrafiltration
  • Filtration Area
  • 2.5 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Height
  • 7.6 cm (3 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 21 cm (8.3 in.)
  • Material Size
  • 1
  • Maximum Transmembrane Pressure
  • 3.5 bar (50 psig) @ 30 °C
  • Media
  • Ultracel®
  • Membrane Area
  • 2.5 m²
  • NMWL
  • 1 kDa
  • Recirculation Rate
  • 5–35 L/min @ 0.4 bar (6 psi)
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type C screen (coarse screen)
  • Trade Name
  • Pellicon®
  • Width
  • 17.8 cm (7.0 in.)
SJ4R026W5 Pellicon® 2 V180 2.5M2 8731 
Add to Cart
  • Catalogue Number
  • SJ4R026W5
  • Device Configuration
  • Maxi Cassette
  • Device Size
  • 2.5 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Material Size
  • 1
  • Media
  • Viresolve® 180
  • Membrane Area
  • 2.5 m²
  • Screen Type
  • Type A screen (tight screen)
P2PLBCC25 Pellicon 2 Maxi Ultrafiltration Module PLBC C 2.5 m2 8807 
Add to Cart
  • Catalogue Number
  • P2PLBCC25
  • Chemistry
  • Regenerated Cellulose (RC)
  • Device Configuration
  • Maxi Cassette
  • Device Size
  • 2.5 m²
  • Filter Code
  • PLBC
  • Filter Type
  • Ultrafiltration
  • Filtration Area
  • 2.5 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Height
  • 7.6 cm (3 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 21 cm (8.3 in.)
  • Material Size
  • 1
  • Maximum Transmembrane Pressure
  • 3.5 bar (50 psig) @ 30 °C
  • Media
  • Ultracel®
  • Membrane Area
  • 2.5 m²
  • NMWL
  • 3 kDa
  • Recirculation Rate
  • 5–35 L/min @ 0.4 bar (6 psi)
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type C screen (coarse screen)
  • Trade Name
  • Pellicon®
  • Width
  • 17.8 cm (7.0 in.)
P2VVPPV20 Pellicon® 2 Maxi Cassette with Durapore 0.1 µm Membrane, V screen, 2 m² 9143 
Add to Cart
  • Catalogue Number
  • P2VVPPV20
  • Chemistry
  • Polyvinylidene Fluoride (PVDF)
  • Device Configuration
  • Maxi Cassette
  • Device Material
  • Polypropylene and Polysulfone end cap
  • Filter Code
  • VVPP
  • Filter Type
  • Microfiltration
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Height
  • 9.0 cm (3.5 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 20.6 cm (8.1 in)
  • Material Size
  • 1
  • Maximum Operating Temperature
  • 50˚C
  • Maximum Transmembrane Pressure
  • Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
  • Media
  • Durapore®
  • Membrane Area
  • 2 m²
  • Operating Temperature Range
  • 4 to 50 °C
  • pH Range
  • pH2 – pH11
  • Pore Size
  • 0.1 µm
  • Recirculation Rate
  • 7 to 10 L/min/m²
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type V screen (open channel)
  • Trade Name
  • Pellicon®
  • Width
  • 17.8 cm (7.0 in.)
P2VVPPV20 Pellicon® 2 Maxi Cassette with Durapore 0.1 µm Membrane, V screen, 2 m² 9143 
Add to Cart
  • Catalogue Number
  • P2VVPPV20
  • Chemistry
  • Polyvinylidene Fluoride (PVDF)
  • Device Configuration
  • Maxi Cassette
  • Device Material
  • Polypropylene and Polysulfone end cap
  • Filter Code
  • VVPP
  • Filter Type
  • Microfiltration
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Height
  • 9.0 cm (3.5 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 20.6 cm (8.1 in)
  • Material Size
  • 1
  • Maximum Operating Temperature
  • 50˚C
  • Maximum Transmembrane Pressure
  • Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
  • Media
  • Durapore®
  • Membrane Area
  • 2 m²
  • Operating Temperature Range
  • 4 to 50 °C
  • pH Range
  • pH2 – pH11
  • Pore Size
  • 0.1 µm
  • Recirculation Rate
  • 7 to 10 L/min/m²
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type V screen (open channel)
  • Trade Name
  • Pellicon®
  • Width
  • 17.8 cm (7.0 in.)
P2B01MC25 Pellicon® 2 Maxi Cassette with Biomax® 1000 kDa Membrane, C screen, 2.5 m² 9199 
Add to Cart
  • Catalogue Number
  • P2B01MC25
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Maxi Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • Biomax 1000
  • Filter Type
  • Ultrafiltration
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Height
  • 7.6 cm (3 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 20.6 cm (8.1 in)
  • Material Size
  • 1
  • Maximum Operating Temperature
  • 0 - 50°C
  • Maximum Transmembrane Pressure
  • Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
  • Media
  • Biomax®
  • Membrane Area
  • 2.5 m²
  • NMWL
  • 1000 kDa
  • pH Range
  • pH1 – pH14
  • Recirculation Rate
  • 4 to 7 L/min/m²
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type C screen (coarse screen)
  • Trade Name
  • Pellicon®
  • Width
  • 17.8 cm (7.0 in.)
P2B01MC25 Pellicon® 2 Maxi Cassette with Biomax® 1000 kDa Membrane, C screen, 2.5 m² 9199 
Add to Cart
  • Catalogue Number
  • P2B01MC25
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Maxi Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • Biomax 1000
  • Filter Type
  • Ultrafiltration
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Height
  • 7.6 cm (3 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 20.6 cm (8.1 in)
  • Material Size
  • 1
  • Maximum Operating Temperature
  • 0 - 50°C
  • Maximum Transmembrane Pressure
  • Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
  • Media
  • Biomax®
  • Membrane Area
  • 2.5 m²
  • NMWL
  • 1000 kDa
  • pH Range
  • pH1 – pH14
  • Recirculation Rate
  • 4 to 7 L/min/m²
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type C screen (coarse screen)
  • Trade Name
  • Pellicon®
  • Width
  • 17.8 cm (7.0 in.)

Overview

Analytical Sample Preparation Membrane Filtration Devices


Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.


Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.


Filter Membranes

Millex® Syringe Filters

Filtration Holders & Accessories



Resources