CN1273V06
Polygard-CN Cartridge Filter 30 in. 1.2 µm Code 7 Fluoroelastomer
2222
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Code
Code 7 (2-226) O-rings w/locking-tabs
Cartridge Nominal Length
30 in. (75 cm)
Catalogue Number
CN1273V06
Chemistry
Polypropylene (PP)
Device Configuration
Cartridge
Device Material
Polypropylene
Diameter
7.0 cm (2.75 in.)
Filtration Area
1.26 m²
Gravimetric Extractables
≤150 mg after 24-h soak in water
Length
30 in. (75 cm)
Material Size
6
Maximum Differential Pressure, bar (psid)
4.8 bar (70 psid) @ 25 °C
Maximum Inlet Pressure, bar (psi)
4.8 bar (70 psi) @ 25 °C
Nominal Pore Size
1.2 µm
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥15 L
Pore Size
1.2 µm
Sanitization
30 min with hot water @ 80 °C
Seal Material
Fluorocarbon rubber
Sterilization
10 autoclave cycles or SIP @ 126 °C for 30 min
Trade Name
Polygard®
Wettability
Hydrophilic
P2B010A05
Pellicon® 2 Cassette with Biomax® 10 kDa Membrane, A screen, 0.5 m²
2225
Add to Cart
Catalogue Number
P2B010A05
Chemistry
Polyethersulfone (PES)
Device Configuration
Cassette
Device Material
Polypropylene
Filter Code
Biomax 10
Filter Type
Ultrafiltration
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 1500 mg/m² after a water flush.
Height
1.5 cm (0.6 in.)
Key Applications
Protein PurificationAnalytical Sample Prep
Length
20.6 cm (8.1 in)
Material Size
1
Maximum Operating Temperature
0 - 50°C
Maximum Transmembrane Pressure
Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
Media
Biomax®
Membrane Area
0.5 m²
NMWL
10 kDa
pH Range
pH1 – pH14
Recirculation Rate
4 to 7 L/min/m²
Screen Material
Polypropylene (PP)
Screen Type
Type A screen (tight screen)
Trade Name
Pellicon®
Width
17.8 cm (7.0 in.)
P2B010A05
Pellicon® 2 Cassette with Biomax® 10 kDa Membrane, A screen, 0.5 m²
2225
Add to Cart
Catalogue Number
P2B010A05
Chemistry
Polyethersulfone (PES)
Device Configuration
Cassette
Device Material
Polypropylene
Filter Code
Biomax 10
Filter Type
Ultrafiltration
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 1500 mg/m² after a water flush.
Height
1.5 cm (0.6 in.)
Key Applications
Protein PurificationAnalytical Sample Prep
Length
20.6 cm (8.1 in)
Material Size
1
Maximum Operating Temperature
0 - 50°C
Maximum Transmembrane Pressure
Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
Media
Biomax®
Membrane Area
0.5 m²
NMWL
10 kDa
pH Range
pH1 – pH14
Recirculation Rate
4 to 7 L/min/m²
Screen Material
Polypropylene (PP)
Screen Type
Type A screen (tight screen)
Trade Name
Pellicon®
Width
17.8 cm (7.0 in.)
P2B030A05
Pellicon® 2 Cassette with Biomax® 30 kDa Membrane, A screen, 0.5 m²
2225
Add to Cart
Catalogue Number
P2B030A05
Chemistry
Polyethersulfone (PES)
Device Configuration
Cassette
Device Material
Polypropylene
Filter Code
Biomax 30
Filter Type
Ultrafiltration
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 1500 mg/m² after a water flush.
Height
1.5 cm (0.6 in.)
Key Applications
Protein PurificationAnalytical Sample Prep
Length
20.6 cm (8.1 in)
Material Size
1
Maximum Operating Temperature
0 - 50°C
Maximum Transmembrane Pressure
Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
Media
Biomax®
Membrane Area
0.5 m²
NMWL
30 kDa
pH Range
pH1 – pH14
Recirculation Rate
4 to 7 L/min/m²
Screen Material
Polypropylene (PP)
Screen Type
Type A screen (tight screen)
Trade Name
Pellicon®
Width
17.8 cm (7.0 in.)
P2B030A05
Pellicon® 2 Cassette with Biomax® 30 kDa Membrane, A screen, 0.5 m²
2225
Add to Cart
Catalogue Number
P2B030A05
Chemistry
Polyethersulfone (PES)
Device Configuration
Cassette
Device Material
Polypropylene
Filter Code
Biomax 30
Filter Type
Ultrafiltration
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 1500 mg/m² after a water flush.
Height
1.5 cm (0.6 in.)
Key Applications
Protein PurificationAnalytical Sample Prep
Length
20.6 cm (8.1 in)
Material Size
1
Maximum Operating Temperature
0 - 50°C
Maximum Transmembrane Pressure
Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
Media
Biomax®
Membrane Area
0.5 m²
NMWL
30 kDa
pH Range
pH1 – pH14
Recirculation Rate
4 to 7 L/min/m²
Screen Material
Polypropylene (PP)
Screen Type
Type A screen (tight screen)
Trade Name
Pellicon®
Width
17.8 cm (7.0 in.)
P2B050A05
Pellicon® 2 Cassette with Biomax® 50 kDa Membrane, A screen, 0.5 m²
2225
Add to Cart
Catalogue Number
P2B050A05
Chemistry
Polyethersulfone (PES)
Device Configuration
Cassette
Device Material
Polypropylene
Filter Code
Biomax 50
Filter Type
Ultrafiltration
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 1500 mg/m² after a water flush.
Height
1.5 cm (0.6 in.)
Key Applications
Protein PurificationAnalytical Sample Prep
Length
20.6 cm (8.1 in)
Material Size
1
Maximum Operating Temperature
0 - 50°C
Maximum Transmembrane Pressure
Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
Media
Biomax®
Membrane Area
0.5 m²
NMWL
50 kDa
pH Range
pH1 – pH14
Recirculation Rate
4 to 7 L/min/m²
Screen Material
Polypropylene (PP)
Screen Type
Type A screen (tight screen)
Trade Name
Pellicon®
Width
17.8 cm (7.0 in.)
P2B050A05
Pellicon® 2 Cassette with Biomax® 50 kDa Membrane, A screen, 0.5 m²
2225
Add to Cart
Catalogue Number
P2B050A05
Chemistry
Polyethersulfone (PES)
Device Configuration
Cassette
Device Material
Polypropylene
Filter Code
Biomax 50
Filter Type
Ultrafiltration
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 1500 mg/m² after a water flush.
Height
1.5 cm (0.6 in.)
Key Applications
Protein PurificationAnalytical Sample Prep
Length
20.6 cm (8.1 in)
Material Size
1
Maximum Operating Temperature
0 - 50°C
Maximum Transmembrane Pressure
Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
Media
Biomax®
Membrane Area
0.5 m²
NMWL
50 kDa
pH Range
pH1 – pH14
Recirculation Rate
4 to 7 L/min/m²
Screen Material
Polypropylene (PP)
Screen Type
Type A screen (tight screen)
Trade Name
Pellicon®
Width
17.8 cm (7.0 in.)
P2C030C05
Pellicon® 2 Cassette with Ultracel® 30 kDa Membrane, C screen, 0.5 m²
2225
Add to Cart
Catalogue Number
P2C030C05
Chemistry
Composite Regenerated Cellulose (CRC)
Device Configuration
Cassette
Device Material
Polypropylene
Device Size
(delete)
Filter Code
PLCTK
Filter Type
Ultrafiltration
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 1500 mg/m² after a water flush.
Height
1.5 cm (0.6 in.)
Key Applications
Protein PurificationAnalytical Sample Prep
Length
20.6 cm (8.1 in)
Material Size
1
Maximum Operating Temperature
0 - 30°C
Maximum Transmembrane Pressure
Forward: 3.4 bar (50 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
Media
Ultracel®
Membrane Area
0.5 m²
NMWL
30 kDa
pH Range
pH2 – pH13
Recirculation Rate
4 to 7 L/min/m²
Screen Material
Polypropylene (PP)
Screen Type
Type C screen (coarse screen)
Trade Name
Pellicon®
Width
17.8 cm (7.0 in.)
P2C030C05
Pellicon® 2 Cassette with Ultracel® 30 kDa Membrane, C screen, 0.5 m²
2225
Add to Cart
Catalogue Number
P2C030C05
Chemistry
Composite Regenerated Cellulose (CRC)
Device Configuration
Cassette
Device Material
Polypropylene
Device Size
(delete)
Filter Code
PLCTK
Filter Type
Ultrafiltration
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 1500 mg/m² after a water flush.
Height
1.5 cm (0.6 in.)
Key Applications
Protein PurificationAnalytical Sample Prep
Length
20.6 cm (8.1 in)
Material Size
1
Maximum Operating Temperature
0 - 30°C
Maximum Transmembrane Pressure
Forward: 3.4 bar (50 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
Media
Ultracel®
Membrane Area
0.5 m²
NMWL
30 kDa
pH Range
pH2 – pH13
Recirculation Rate
4 to 7 L/min/m²
Screen Material
Polypropylene (PP)
Screen Type
Type C screen (coarse screen)
Trade Name
Pellicon®
Width
17.8 cm (7.0 in.)
CVDR03TP3
Durapore® Cartridge Filter with prefilter 30 in. 0.65 µm Code 0
2245
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Code
Code 0 (2-222) O-rings
Cartridge Nominal Length
30 in. (75 cm)
Catalogue Number
CVDR03TP3
Chemistry
Polyvinylidene Fluoride (PVDF)
Device Configuration
Cartridge
Device Material
Polypropylene
Device Size
30 in.
Diameter
6.9 cm (2.7 in.)
Filtration Area
2.07 m²
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 45 mg per 10-inch cartridge after 24 hours in water at controlled room temperature.
Indirect Food Additive
All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182. All component materials meet the requirements of the EU framework regulation [1935/2004/EC] regarding materials and articles intended to contact food.
Length
30 in. (75 cm)
Material Package
Double Easy-Open bag
Material Size
3
Maximum Differential Pressure, bar (psid)
Forward: 5.5 bar (80 psid) @ 25 °C; 1.7 bar (25 psid) @ 80 °C; 0.35 bar (5 psid) @ 121 °C. Reverse: 1.7 bar (25 psid) @ 25 °C
Maximum Inlet Pressure, bar (psi)
Forward - 5.5 bar (80 psi) @ 25 °C; 1.7 bar (25 psi) @ 80 °C; 0.35 bar (5 psi) @ 121 °C; Reverse - 1.7 bar (25 psi) @ 25 °C
Media
Durapore® w/Prefilter
Non-Fiber Releasing
This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥1 L
Pore Size
0.65 µm
Seal Material
Silicone (SI)
Sterility
Other
Sterilization
8 SIP cycles of 30 min or 8 autoclave cycles of 60 min @ 121 °C
Support Material
Polypropylene
Trade Name
Durapore®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Wettability
Hydrophilic