We have developed a unique portfolio of consumables, each adapted to the different feed water quality requirements and to your various applications. To maintain your water system’s performance, it’s critical to replace your purification cartridges on time and with genuine ISO 9001-certified parts.

Catalog No. Product Net Price
PXB500C50 Pellicon® XL50 with Biomax® 500 kDa Membrane, C screen, 50 cm² 232 
Add to Cart
  • Catalogue Number
  • PXB500C50
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • Biomax 500
  • Filter Type
  • Ultrafiltration
  • Filtration Area
  • 50 cm²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 7.5 mg per device after a water flush
  • Hold-up Volume
  • 3.2 mL
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 18.8 cm (7.4 in.)
  • Material Package
  • Each Pellicon® XL50 cassette is packaged one per box and includes Operating Instructions, an Accessory Kit and a Certificate of Quality
  • Material Size
  • 1
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 50 °C
  • Maximum Transmembrane Pressure
  • 2.8 bar (40 psig)
  • Media
  • Biomax®
  • Membrane Area
  • 50 cm²
  • Minimum Working Volume
  • 15 mL
  • NMWL
  • 500 kDa
  • pH Range
  • pH1 – pH14 continuous; pH1 – pH14 cleaning
  • Recirculation Rate
  • 0.03–0.05 L/min
  • Screen Material
  • Polypropylene, Thermoplastic Elastomer
  • Screen Type
  • Type C screen (coarse screen)
  • Trade Name
  • Pellicon®
  • Volume
  • 3.2 mL
  • Width
  • 3 cm (1.2 in.)
PXC005C50 Pellicon® XL50 with Ultracel® 5 kDa Membrane, C screen, 50 cm² 232 
Add to Cart
  • Catalogue Number
  • PXC005C50
  • Chemistry
  • Composite Regenerated Cellulose (CRC)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • PLCCC
  • Filter Type
  • Ultrafiltration
  • Filtration Area
  • 50 cm²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 7.5 mg per device after a water flush
  • Hold-up Volume
  • 3.2 mL
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 18.8 cm (7.4 in.)
  • Material Package
  • Each Pellicon® XL50 cassette is packaged one per box and includes Operating Instructions, an Accessory Kit and a Certificate of Quality
  • Material Size
  • 1
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 50 °C
  • Maximum Transmembrane Pressure
  • 2.8 bar (40 psig)
  • Media
  • Ultracel®
  • Membrane Area
  • 50 cm²
  • Minimum Working Volume
  • 15 mL
  • NMWL
  • 5 kDa
  • pH Range
  • pH2 – pH12 continuous; pH2 – pH13 cleaning
  • Recirculation Rate
  • 0.03–0.05 L/min
  • Screen Material
  • Polypropylene, Thermoplastic Elastomer
  • Screen Type
  • Type C screen (coarse screen)
  • Trade Name
  • Pellicon®
  • Volume
  • 3.2 mL
  • Width
  • 3 cm (1.2 in.)
PXC005C50 Pellicon® XL50 with Ultracel® 5 kDa Membrane, C screen, 50 cm² 232 
Add to Cart
  • Catalogue Number
  • PXC005C50
  • Chemistry
  • Composite Regenerated Cellulose (CRC)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • PLCCC
  • Filter Type
  • Ultrafiltration
  • Filtration Area
  • 50 cm²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 7.5 mg per device after a water flush
  • Hold-up Volume
  • 3.2 mL
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 18.8 cm (7.4 in.)
  • Material Package
  • Each Pellicon® XL50 cassette is packaged one per box and includes Operating Instructions, an Accessory Kit and a Certificate of Quality
  • Material Size
  • 1
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 50 °C
  • Maximum Transmembrane Pressure
  • 2.8 bar (40 psig)
  • Media
  • Ultracel®
  • Membrane Area
  • 50 cm²
  • Minimum Working Volume
  • 15 mL
  • NMWL
  • 5 kDa
  • pH Range
  • pH2 – pH12 continuous; pH2 – pH13 cleaning
  • Recirculation Rate
  • 0.03–0.05 L/min
  • Screen Material
  • Polypropylene, Thermoplastic Elastomer
  • Screen Type
  • Type C screen (coarse screen)
  • Trade Name
  • Pellicon®
  • Volume
  • 3.2 mL
  • Width
  • 3 cm (1.2 in.)
PXC010C50 Pellicon® XL50 with Ultracel® 10 kDa Membrane, C screen, 50 cm² 232 
Add to Cart
  • Catalogue Number
  • PXC010C50
  • Chemistry
  • Composite Regenerated Cellulose (CRC)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • PLCGC
  • Filter Type
  • Ultrafiltration
  • Filtration Area
  • 50 cm²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 7.5 mg per device after a water flush
  • Hold-up Volume
  • 3.2 mL
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 18.8 cm (7.4 in.)
  • Material Package
  • Each Pellicon® XL50 cassette is packaged one per box and includes Operating Instructions, an Accessory Kit and a Certificate of Quality
  • Material Size
  • 1
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 50 °C
  • Maximum Transmembrane Pressure
  • 2.8 bar (40 psig)
  • Media
  • Ultracel®
  • Membrane Area
  • 50 cm²
  • Minimum Working Volume
  • 15 mL
  • NMWL
  • 10 kDa
  • pH Range
  • pH2 – pH12 continuous; pH2 – pH13 cleaning
  • Recirculation Rate
  • 0.03–0.05 L/min
  • Screen Material
  • Polypropylene, Thermoplastic Elastomer
  • Screen Type
  • Type C screen (coarse screen)
  • Trade Name
  • Pellicon®
  • Volume
  • 3.2 mL
  • Width
  • 3 cm (1.2 in.)
PXC010C50 Pellicon® XL50 with Ultracel® 10 kDa Membrane, C screen, 50 cm² 232 
Add to Cart
  • Catalogue Number
  • PXC010C50
  • Chemistry
  • Composite Regenerated Cellulose (CRC)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • PLCGC
  • Filter Type
  • Ultrafiltration
  • Filtration Area
  • 50 cm²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 7.5 mg per device after a water flush
  • Hold-up Volume
  • 3.2 mL
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 18.8 cm (7.4 in.)
  • Material Package
  • Each Pellicon® XL50 cassette is packaged one per box and includes Operating Instructions, an Accessory Kit and a Certificate of Quality
  • Material Size
  • 1
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 50 °C
  • Maximum Transmembrane Pressure
  • 2.8 bar (40 psig)
  • Media
  • Ultracel®
  • Membrane Area
  • 50 cm²
  • Minimum Working Volume
  • 15 mL
  • NMWL
  • 10 kDa
  • pH Range
  • pH2 – pH12 continuous; pH2 – pH13 cleaning
  • Recirculation Rate
  • 0.03–0.05 L/min
  • Screen Material
  • Polypropylene, Thermoplastic Elastomer
  • Screen Type
  • Type C screen (coarse screen)
  • Trade Name
  • Pellicon®
  • Volume
  • 3.2 mL
  • Width
  • 3 cm (1.2 in.)
PXC01MC50 Pellicon® XL50 with Ultracel® 1000 kDa Membrane, C screen, 50 cm² 232 
Add to Cart
  • Catalogue Number
  • PXC01MC50
  • Chemistry
  • Composite Regenerated Cellulose (CRC)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • PLCXK
  • Filter Type
  • Ultrafiltration
  • Filtration Area
  • 50 cm²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 7.5 mg per device after a water flush
  • Hold-up Volume
  • 3.2 mL
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 18.8 cm (7.4 in.)
  • Material Package
  • Each Pellicon® XL50 cassette is packaged one per box and includes Operating Instructions, an Accessory Kit and a Certificate of Quality
  • Material Size
  • 1
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 50 °C
  • Maximum Transmembrane Pressure
  • 2.8 bar (40 psig)
  • Media
  • Ultracel®
  • Membrane Area
  • 50 cm²
  • Minimum Working Volume
  • 15 mL
  • NMWL
  • 1000 kDa
  • pH Range
  • pH2 – pH12 continuous; pH2 – pH13 cleaning
  • Recirculation Rate
  • 0.03–0.05 L/min
  • Screen Material
  • Polypropylene, Thermoplastic Elastomer
  • Screen Type
  • Type C screen (coarse screen)
  • Trade Name
  • Pellicon®
  • Volume
  • 3.2 mL
  • Width
  • 3 cm (1.2 in.)
PXC01MC50 Pellicon® XL50 with Ultracel® 1000 kDa Membrane, C screen, 50 cm² 232 
Add to Cart
  • Catalogue Number
  • PXC01MC50
  • Chemistry
  • Composite Regenerated Cellulose (CRC)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • PLCXK
  • Filter Type
  • Ultrafiltration
  • Filtration Area
  • 50 cm²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 7.5 mg per device after a water flush
  • Hold-up Volume
  • 3.2 mL
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 18.8 cm (7.4 in.)
  • Material Package
  • Each Pellicon® XL50 cassette is packaged one per box and includes Operating Instructions, an Accessory Kit and a Certificate of Quality
  • Material Size
  • 1
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 50 °C
  • Maximum Transmembrane Pressure
  • 2.8 bar (40 psig)
  • Media
  • Ultracel®
  • Membrane Area
  • 50 cm²
  • Minimum Working Volume
  • 15 mL
  • NMWL
  • 1000 kDa
  • pH Range
  • pH2 – pH12 continuous; pH2 – pH13 cleaning
  • Recirculation Rate
  • 0.03–0.05 L/min
  • Screen Material
  • Polypropylene, Thermoplastic Elastomer
  • Screen Type
  • Type C screen (coarse screen)
  • Trade Name
  • Pellicon®
  • Volume
  • 3.2 mL
  • Width
  • 3 cm (1.2 in.)
PXC030C50 Pellicon® XL50 with Ultracel® 30 kDa Membrane, C screen, 50 cm² 232 
Add to Cart
  • Catalogue Number
  • PXC030C50
  • Chemistry
  • Composite Regenerated Cellulose (CRC)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • PLCTK
  • Filter Type
  • Ultrafiltration
  • Filtration Area
  • 50 cm²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 7.5 mg per device after a water flush
  • Hold-up Volume
  • 3.2 mL
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 18.8 cm (7.4 in.)
  • Material Package
  • Each Pellicon® XL50 cassette is packaged one per box and includes Operating Instructions, an Accessory Kit and a Certificate of Quality
  • Material Size
  • 1
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 50 °C
  • Maximum Transmembrane Pressure
  • 2.8 bar (40 psig)
  • Media
  • Ultracel®
  • Membrane Area
  • 50 cm²
  • Minimum Working Volume
  • 15 mL
  • NMWL
  • 30 kDa
  • pH Range
  • pH2 – pH12 continuous; pH2 – pH13 cleaning
  • Recirculation Rate
  • 0.03–0.05 L/min
  • Screen Material
  • Polypropylene, Thermoplastic Elastomer
  • Screen Type
  • Type C screen (coarse screen)
  • Trade Name
  • Pellicon®
  • Volume
  • 3.2 mL
  • Width
  • 3 cm (1.2 in.)
PXC030C50 Pellicon® XL50 with Ultracel® 30 kDa Membrane, C screen, 50 cm² 232 
Add to Cart
  • Catalogue Number
  • PXC030C50
  • Chemistry
  • Composite Regenerated Cellulose (CRC)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • PLCTK
  • Filter Type
  • Ultrafiltration
  • Filtration Area
  • 50 cm²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 7.5 mg per device after a water flush
  • Hold-up Volume
  • 3.2 mL
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 18.8 cm (7.4 in.)
  • Material Package
  • Each Pellicon® XL50 cassette is packaged one per box and includes Operating Instructions, an Accessory Kit and a Certificate of Quality
  • Material Size
  • 1
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 50 °C
  • Maximum Transmembrane Pressure
  • 2.8 bar (40 psig)
  • Media
  • Ultracel®
  • Membrane Area
  • 50 cm²
  • Minimum Working Volume
  • 15 mL
  • NMWL
  • 30 kDa
  • pH Range
  • pH2 – pH12 continuous; pH2 – pH13 cleaning
  • Recirculation Rate
  • 0.03–0.05 L/min
  • Screen Material
  • Polypropylene, Thermoplastic Elastomer
  • Screen Type
  • Type C screen (coarse screen)
  • Trade Name
  • Pellicon®
  • Volume
  • 3.2 mL
  • Width
  • 3 cm (1.2 in.)
PXC300C50 Pellicon® XL50 with Ultracel® 300 kDa Membrane, C screen, 50 cm² 232 
Add to Cart
  • Catalogue Number
  • PXC300C50
  • Chemistry
  • Composite Regenerated Cellulose (CRC)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • PLCMK
  • Filter Type
  • Ultrafiltration
  • Filtration Area
  • 50 cm²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 7.5 mg per device after a water flush
  • Hold-up Volume
  • 3.2 mL
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 18.8 cm (7.4 in.)
  • Material Package
  • Each Pellicon® XL50 cassette is packaged one per box and includes Operating Instructions, an Accessory Kit and a Certificate of Quality
  • Material Size
  • 1
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 50 °C
  • Maximum Transmembrane Pressure
  • 2.8 bar (40 psig)
  • Media
  • Ultracel®
  • Membrane Area
  • 50 cm²
  • Minimum Working Volume
  • 15 mL
  • NMWL
  • 300 kDa
  • pH Range
  • pH2 – pH12 continuous; pH2 – pH13 cleaning
  • Recirculation Rate
  • 0.03–0.05 L/min
  • Screen Material
  • Polypropylene, Thermoplastic Elastomer
  • Screen Type
  • Type C screen (coarse screen)
  • Trade Name
  • Pellicon®
  • Volume
  • 3.2 mL
  • Width
  • 3 cm (1.2 in.)

Overview

Analytical Sample Preparation Membrane Filtration Devices


Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.


Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.


Filter Membranes

Millex® Syringe Filters

Filtration Holders & Accessories



Resources