+852-3069 6950
css@gugent.com.hk
 

We have developed a unique portfolio of consumables, each adapted to the different feed water quality requirements and to your various applications. To maintain your water system’s performance, it’s critical to replace your purification cartridges on time and with genuine ISO 9001-certified parts.

Catalog No. Product Net Price
PXB01MC50 Pellicon® XL50 with Biomax® 1000 kDa Membrane, C screen, 50 cm² 232 
Add to Cart
  • Catalogue Number
  • PXB01MC50
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • Biomax 1000
  • Filter Type
  • Ultrafiltration
  • Filtration Area
  • 50 cm²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 7.5 mg per device after a water flush
  • Hold-up Volume
  • 3.2 mL
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 18.8 cm (7.4 in.)
  • Material Package
  • Each Pellicon® XL50 cassette is packaged one per box and includes Operating Instructions, an Accessory Kit and a Certificate of Quality
  • Material Size
  • 1
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 50 °C
  • Maximum Transmembrane Pressure
  • 2.8 bar (40 psig)
  • Media
  • Biomax®
  • Membrane Area
  • 50 cm²
  • Minimum Working Volume
  • 15 mL
  • NMWL
  • 1000 kDa
  • pH Range
  • pH1 – pH14 continuous; pH1 – pH14 cleaning
  • Recirculation Rate
  • 0.03–0.05 L/min
  • Screen Material
  • Polypropylene, Thermoplastic Elastomer
  • Screen Type
  • Type C screen (coarse screen)
  • Trade Name
  • Pellicon®
  • Volume
  • 3.2 mL
  • Width
  • 3 cm (1.2 in.)
PXB030A50 Pellicon® XL50 with Biomax® 30 kDa Membrane, A screen, 50 cm² 232 
Add to Cart
  • Catalogue Number
  • PXB030A50
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • Biomax 30
  • Filter Type
  • Ultrafiltration
  • Filtration Area
  • 50 cm²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 7.5 mg per device after a water flush
  • Hold-up Volume
  • 3.2 mL
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 18.8 cm (7.4 in.)
  • Material Package
  • Each Pellicon® XL50 cassette is packaged one per box and includes Operating Instructions, an Accessory Kit and a Certificate of Quality
  • Material Size
  • 1
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 50 °C
  • Maximum Transmembrane Pressure
  • 2.8 bar (40 psig)
  • Media
  • Biomax®
  • Membrane Area
  • 50 cm²
  • Minimum Working Volume
  • 15 mL
  • NMWL
  • 30 kDa
  • pH Range
  • pH1 – pH14 continuous; pH1 – pH14 cleaning
  • Recirculation Rate
  • 0.03–0.05 L/min
  • Screen Material
  • Polypropylene, Thermoplastic Elastomer
  • Screen Type
  • Type A screen (tight screen)
  • Trade Name
  • Pellicon®
  • Volume
  • 3.2 mL
  • Width
  • 3 cm (1.2 in.)
PXB030A50 Pellicon® XL50 with Biomax® 30 kDa Membrane, A screen, 50 cm² 232 
Add to Cart
  • Catalogue Number
  • PXB030A50
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • Biomax 30
  • Filter Type
  • Ultrafiltration
  • Filtration Area
  • 50 cm²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 7.5 mg per device after a water flush
  • Hold-up Volume
  • 3.2 mL
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 18.8 cm (7.4 in.)
  • Material Package
  • Each Pellicon® XL50 cassette is packaged one per box and includes Operating Instructions, an Accessory Kit and a Certificate of Quality
  • Material Size
  • 1
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 50 °C
  • Maximum Transmembrane Pressure
  • 2.8 bar (40 psig)
  • Media
  • Biomax®
  • Membrane Area
  • 50 cm²
  • Minimum Working Volume
  • 15 mL
  • NMWL
  • 30 kDa
  • pH Range
  • pH1 – pH14 continuous; pH1 – pH14 cleaning
  • Recirculation Rate
  • 0.03–0.05 L/min
  • Screen Material
  • Polypropylene, Thermoplastic Elastomer
  • Screen Type
  • Type A screen (tight screen)
  • Trade Name
  • Pellicon®
  • Volume
  • 3.2 mL
  • Width
  • 3 cm (1.2 in.)
PXB050A50 Pellicon® XL50 with Biomax® 50 kDa Membrane, A screen, 50 cm² 232 
Add to Cart
  • Catalogue Number
  • PXB050A50
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • Biomax 50
  • Filter Type
  • Ultrafiltration
  • Filtration Area
  • 50 cm²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 7.5 mg per device after a water flush
  • Hold-up Volume
  • 3.2 mL
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 18.8 cm (7.4 in.)
  • Material Package
  • Each Pellicon® XL50 cassette is packaged one per box and includes Operating Instructions, an Accessory Kit and a Certificate of Quality
  • Material Size
  • 1
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 50 °C
  • Maximum Transmembrane Pressure
  • 2.8 bar (40 psig)
  • Media
  • Biomax®
  • Membrane Area
  • 50 cm²
  • Minimum Working Volume
  • 15 mL
  • NMWL
  • 50 kDa
  • pH Range
  • pH1 – pH14 continuous; pH1 – pH14 cleaning
  • Recirculation Rate
  • 0.03–0.05 L/min
  • Screen Material
  • Polypropylene, Thermoplastic Elastomer
  • Screen Type
  • Type A screen (tight screen)
  • Trade Name
  • Pellicon®
  • Volume
  • 3.2 mL
  • Width
  • 3 cm (1.2 in.)
PXB050A50 Pellicon® XL50 with Biomax® 50 kDa Membrane, A screen, 50 cm² 232 
Add to Cart
  • Catalogue Number
  • PXB050A50
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • Biomax 50
  • Filter Type
  • Ultrafiltration
  • Filtration Area
  • 50 cm²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 7.5 mg per device after a water flush
  • Hold-up Volume
  • 3.2 mL
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 18.8 cm (7.4 in.)
  • Material Package
  • Each Pellicon® XL50 cassette is packaged one per box and includes Operating Instructions, an Accessory Kit and a Certificate of Quality
  • Material Size
  • 1
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 50 °C
  • Maximum Transmembrane Pressure
  • 2.8 bar (40 psig)
  • Media
  • Biomax®
  • Membrane Area
  • 50 cm²
  • Minimum Working Volume
  • 15 mL
  • NMWL
  • 50 kDa
  • pH Range
  • pH1 – pH14 continuous; pH1 – pH14 cleaning
  • Recirculation Rate
  • 0.03–0.05 L/min
  • Screen Material
  • Polypropylene, Thermoplastic Elastomer
  • Screen Type
  • Type A screen (tight screen)
  • Trade Name
  • Pellicon®
  • Volume
  • 3.2 mL
  • Width
  • 3 cm (1.2 in.)
PXB100C50 Pellicon® XL50 with Biomax® 100 kDa Membrane, C screen, 50 cm² 232 
Add to Cart
  • Catalogue Number
  • PXB100C50
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • Biomax 100
  • Filter Type
  • Ultrafiltration
  • Filtration Area
  • 50 cm²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 7.5 mg per device after a water flush
  • Hold-up Volume
  • 3.2 mL
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 18.8 cm (7.4 in.)
  • Material Package
  • Each Pellicon® XL50 cassette is packaged one per box and includes Operating Instructions, an Accessory Kit and a Certificate of Quality
  • Material Size
  • 1
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 50 °C
  • Maximum Transmembrane Pressure
  • 2.8 bar (40 psig)
  • Media
  • Biomax®
  • Membrane Area
  • 50 cm²
  • Minimum Working Volume
  • 15 mL
  • NMWL
  • 100 kDa
  • pH Range
  • pH1 – pH14 continuous; pH1 – pH14 cleaning
  • Recirculation Rate
  • 0.03–0.05 L/min
  • Screen Material
  • Polypropylene, Thermoplastic Elastomer
  • Screen Type
  • Type C screen (coarse screen)
  • Trade Name
  • Pellicon®
  • Volume
  • 3.2 mL
  • Width
  • 3 cm (1.2 in.)
PXB100C50 Pellicon® XL50 with Biomax® 100 kDa Membrane, C screen, 50 cm² 232 
Add to Cart
  • Catalogue Number
  • PXB100C50
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • Biomax 100
  • Filter Type
  • Ultrafiltration
  • Filtration Area
  • 50 cm²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 7.5 mg per device after a water flush
  • Hold-up Volume
  • 3.2 mL
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 18.8 cm (7.4 in.)
  • Material Package
  • Each Pellicon® XL50 cassette is packaged one per box and includes Operating Instructions, an Accessory Kit and a Certificate of Quality
  • Material Size
  • 1
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 50 °C
  • Maximum Transmembrane Pressure
  • 2.8 bar (40 psig)
  • Media
  • Biomax®
  • Membrane Area
  • 50 cm²
  • Minimum Working Volume
  • 15 mL
  • NMWL
  • 100 kDa
  • pH Range
  • pH1 – pH14 continuous; pH1 – pH14 cleaning
  • Recirculation Rate
  • 0.03–0.05 L/min
  • Screen Material
  • Polypropylene, Thermoplastic Elastomer
  • Screen Type
  • Type C screen (coarse screen)
  • Trade Name
  • Pellicon®
  • Volume
  • 3.2 mL
  • Width
  • 3 cm (1.2 in.)
PXB300C50 Pellicon® XL50 with Biomax® 300 kDa Membrane, C screen, 50 cm² 232 
Add to Cart
  • Catalogue Number
  • PXB300C50
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • Biomax 300
  • Filter Type
  • Ultrafiltration
  • Filtration Area
  • 50 cm²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 7.5 mg per device after a water flush
  • Hold-up Volume
  • 3.2 mL
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 18.8 cm (7.4 in.)
  • Material Package
  • Each Pellicon® XL50 cassette is packaged one per box and includes Operating Instructions, an Accessory Kit and a Certificate of Quality
  • Material Size
  • 1
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 50 °C
  • Maximum Transmembrane Pressure
  • 2.8 bar (40 psig)
  • Media
  • Biomax®
  • Membrane Area
  • 50 cm²
  • Minimum Working Volume
  • 15 mL
  • NMWL
  • 300 kDa
  • pH Range
  • pH1 – pH14 continuous; pH1 – pH14 cleaning
  • Recirculation Rate
  • 0.03–0.05 L/min
  • Screen Material
  • Polypropylene, Thermoplastic Elastomer
  • Screen Type
  • Type C screen (coarse screen)
  • Trade Name
  • Pellicon®
  • Volume
  • 3.2 mL
  • Width
  • 3 cm (1.2 in.)
PXB300C50 Pellicon® XL50 with Biomax® 300 kDa Membrane, C screen, 50 cm² 232 
Add to Cart
  • Catalogue Number
  • PXB300C50
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • Biomax 300
  • Filter Type
  • Ultrafiltration
  • Filtration Area
  • 50 cm²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 7.5 mg per device after a water flush
  • Hold-up Volume
  • 3.2 mL
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 18.8 cm (7.4 in.)
  • Material Package
  • Each Pellicon® XL50 cassette is packaged one per box and includes Operating Instructions, an Accessory Kit and a Certificate of Quality
  • Material Size
  • 1
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 50 °C
  • Maximum Transmembrane Pressure
  • 2.8 bar (40 psig)
  • Media
  • Biomax®
  • Membrane Area
  • 50 cm²
  • Minimum Working Volume
  • 15 mL
  • NMWL
  • 300 kDa
  • pH Range
  • pH1 – pH14 continuous; pH1 – pH14 cleaning
  • Recirculation Rate
  • 0.03–0.05 L/min
  • Screen Material
  • Polypropylene, Thermoplastic Elastomer
  • Screen Type
  • Type C screen (coarse screen)
  • Trade Name
  • Pellicon®
  • Volume
  • 3.2 mL
  • Width
  • 3 cm (1.2 in.)
PXB500C50 Pellicon® XL50 with Biomax® 500 kDa Membrane, C screen, 50 cm² 232 
Add to Cart
  • Catalogue Number
  • PXB500C50
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • Biomax 500
  • Filter Type
  • Ultrafiltration
  • Filtration Area
  • 50 cm²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 7.5 mg per device after a water flush
  • Hold-up Volume
  • 3.2 mL
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 18.8 cm (7.4 in.)
  • Material Package
  • Each Pellicon® XL50 cassette is packaged one per box and includes Operating Instructions, an Accessory Kit and a Certificate of Quality
  • Material Size
  • 1
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 50 °C
  • Maximum Transmembrane Pressure
  • 2.8 bar (40 psig)
  • Media
  • Biomax®
  • Membrane Area
  • 50 cm²
  • Minimum Working Volume
  • 15 mL
  • NMWL
  • 500 kDa
  • pH Range
  • pH1 – pH14 continuous; pH1 – pH14 cleaning
  • Recirculation Rate
  • 0.03–0.05 L/min
  • Screen Material
  • Polypropylene, Thermoplastic Elastomer
  • Screen Type
  • Type C screen (coarse screen)
  • Trade Name
  • Pellicon®
  • Volume
  • 3.2 mL
  • Width
  • 3 cm (1.2 in.)

Overview

Analytical Sample Preparation Membrane Filtration Devices


Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.


Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.


Filter Membranes

Millex® Syringe Filters

Filtration Holders & Accessories



Resources