+852-3069 6950
css@gugent.com.hk
 

We have developed a unique portfolio of consumables, each adapted to the different feed water quality requirements and to your various applications. To maintain your water system’s performance, it’s critical to replace your purification cartridges on time and with genuine ISO 9001-certified parts.

Catalog No. Product Net Price
PXGVPPC50 Pellicon® XL50 with Durapore® 0.22 µm Membrane, C screen, 50 cm² 244 
Add to Cart
  • Catalogue Number
  • PXGVPPC50
  • Chemistry
  • Polyvinylidene Fluoride (PVDF)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • GVPP
  • Filter Type
  • Microfiltration
  • Filtration Area
  • 50 cm²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 7.5 mg per device after a water flush
  • Hold-up Volume
  • 3.2 mL
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 18.8 cm (7.4 in.)
  • Material Package
  • Each Pellicon® XL50 cassette is packaged one per box and includes Operating Instructions, an Accessory Kit and a Certificate of Quality
  • Material Size
  • 1
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 50 °C
  • Maximum Transmembrane Pressure
  • 2.8 bar (40 psig)
  • Media
  • Durapore®
  • Membrane Area
  • 50 cm²
  • Minimum Working Volume
  • 15 mL
  • pH Range
  • pH1.5 – pH9 continuous; pH1 – pH11 cleaning
  • Pore Size
  • 0.22 µm
  • Recirculation Rate
  • 0.03–0.05 L/min
  • Screen Material
  • Polypropylene, Thermoplastic Elastomer
  • Screen Type
  • Type C screen (coarse screen)
  • Trade Name
  • Pellicon®
  • Volume
  • 3.2 mL
  • Width
  • 3 cm (1.2 in.)
PXHVMPC50 Pellicon® XL50 with Durapore® 0.45 µm Membrane, C screen, 50 cm² 244 
Add to Cart
  • Catalogue Number
  • PXHVMPC50
  • Chemistry
  • Polyvinylidene Fluoride (PVDF)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • HVMP
  • Filter Type
  • Microfiltration
  • Filtration Area
  • 50 cm²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 7.5 mg per device after a water flush
  • Hold-up Volume
  • 3.2 mL
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 18.8 cm (7.4 in.)
  • Material Package
  • Each Pellicon® XL50 cassette is packaged one per box and includes Operating Instructions, an Accessory Kit and a Certificate of Quality
  • Material Size
  • 1
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 50 °C
  • Maximum Transmembrane Pressure
  • 2.8 bar (40 psig)
  • Media
  • Durapore®
  • Membrane Area
  • 50 cm²
  • Minimum Working Volume
  • 15 mL
  • pH Range
  • pH1.5 – pH9 continuous; pH1 – pH11 cleaning
  • Pore Size
  • 0.45 µm
  • Recirculation Rate
  • 0.03–0.05 L/min
  • Screen Material
  • Polypropylene, Thermoplastic Elastomer
  • Screen Type
  • Type C screen (coarse screen)
  • Trade Name
  • Pellicon®
  • Volume
  • 3.2 mL
  • Width
  • 3 cm (1.2 in.)
PXHVMPC50 Pellicon® XL50 with Durapore® 0.45 µm Membrane, C screen, 50 cm² 244 
Add to Cart
  • Catalogue Number
  • PXHVMPC50
  • Chemistry
  • Polyvinylidene Fluoride (PVDF)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • HVMP
  • Filter Type
  • Microfiltration
  • Filtration Area
  • 50 cm²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 7.5 mg per device after a water flush
  • Hold-up Volume
  • 3.2 mL
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 18.8 cm (7.4 in.)
  • Material Package
  • Each Pellicon® XL50 cassette is packaged one per box and includes Operating Instructions, an Accessory Kit and a Certificate of Quality
  • Material Size
  • 1
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 50 °C
  • Maximum Transmembrane Pressure
  • 2.8 bar (40 psig)
  • Media
  • Durapore®
  • Membrane Area
  • 50 cm²
  • Minimum Working Volume
  • 15 mL
  • pH Range
  • pH1.5 – pH9 continuous; pH1 – pH11 cleaning
  • Pore Size
  • 0.45 µm
  • Recirculation Rate
  • 0.03–0.05 L/min
  • Screen Material
  • Polypropylene, Thermoplastic Elastomer
  • Screen Type
  • Type C screen (coarse screen)
  • Trade Name
  • Pellicon®
  • Volume
  • 3.2 mL
  • Width
  • 3 cm (1.2 in.)
PXVVPPC50 Pellicon® XL50 with Durapore® 0.1 µm Membrane, C screen, 50 cm² 244 
Add to Cart
  • Catalogue Number
  • PXVVPPC50
  • Chemistry
  • Polyvinylidene Fluoride (PVDF)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • VVPP
  • Filter Type
  • Microfiltration
  • Filtration Area
  • 50 cm²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 7.5 mg per device after a water flush
  • Hold-up Volume
  • 3.2 mL
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 18.8 cm (7.4 in.)
  • Material Package
  • Each Pellicon® XL50 cassette is packaged one per box and includes Operating Instructions, an Accessory Kit and a Certificate of Quality
  • Material Size
  • 1
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 50 °C
  • Maximum Transmembrane Pressure
  • 2.8 bar (40 psig)
  • Media
  • Durapore®
  • Membrane Area
  • 50 cm²
  • Minimum Working Volume
  • 15 mL
  • pH Range
  • pH1.5 – pH9 continuous; pH1 – pH11 cleaning
  • Pore Size
  • 0.1 µm
  • Recirculation Rate
  • 0.03–0.05 L/min
  • Screen Material
  • Polypropylene, Thermoplastic Elastomer
  • Screen Type
  • Type C screen (coarse screen)
  • Trade Name
  • Pellicon®
  • Volume
  • 3.2 mL
  • Width
  • 3 cm (1.2 in.)
PXVVPPC50 Pellicon® XL50 with Durapore® 0.1 µm Membrane, C screen, 50 cm² 244 
Add to Cart
  • Catalogue Number
  • PXVVPPC50
  • Chemistry
  • Polyvinylidene Fluoride (PVDF)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • VVPP
  • Filter Type
  • Microfiltration
  • Filtration Area
  • 50 cm²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 7.5 mg per device after a water flush
  • Hold-up Volume
  • 3.2 mL
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 18.8 cm (7.4 in.)
  • Material Package
  • Each Pellicon® XL50 cassette is packaged one per box and includes Operating Instructions, an Accessory Kit and a Certificate of Quality
  • Material Size
  • 1
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 50 °C
  • Maximum Transmembrane Pressure
  • 2.8 bar (40 psig)
  • Media
  • Durapore®
  • Membrane Area
  • 50 cm²
  • Minimum Working Volume
  • 15 mL
  • pH Range
  • pH1.5 – pH9 continuous; pH1 – pH11 cleaning
  • Pore Size
  • 0.1 µm
  • Recirculation Rate
  • 0.03–0.05 L/min
  • Screen Material
  • Polypropylene, Thermoplastic Elastomer
  • Screen Type
  • Type C screen (coarse screen)
  • Trade Name
  • Pellicon®
  • Volume
  • 3.2 mL
  • Width
  • 3 cm (1.2 in.)
D003P3S01 Clarigard Cartridge Filter 30 in. 0.3 µm Code P Silicone 245 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code P double open end w/flat gaskets
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • D003P3S01
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Gravimetric Extractables
  • ≤30 mg after 24-h soak in water
  • Length
  • 30 in. (75 cm)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 0.3 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥9 L
  • Pore Size
  • 0.3 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Clarigard®
  • Wettability
  • Hydrophilic
D003P3S01 Clarigard Cartridge Filter 30 in. 0.3 µm Code P Silicone 245 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code P double open end w/flat gaskets
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • D003P3S01
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Gravimetric Extractables
  • ≤30 mg after 24-h soak in water
  • Length
  • 30 in. (75 cm)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 0.3 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥9 L
  • Pore Size
  • 0.3 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Clarigard®
  • Wettability
  • Hydrophilic
KHGEG003HB3 Opticap® Gamma Compatible XL 300 Millipore Express® SHC 0.5/0.2 µm 9/16 in. HB/HB with Bell 245 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Bacterial Retention
  • Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
  • Cartridge Nominal Length
  • 4.7 in. (11.9 cm)
  • Catalogue Number
  • KHGEG003HB3
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Capsule
  • Device Material
  • Gamma stable polypropylene/Polysulfone
  • Diameter
  • 5.6 cm (2.2 in.)
  • European Pressure Equipment Directive
  • EMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
  • Filtration Area
  • 290 cm²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Housing Material
  • Polypropylene (PP)
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Hose Barb
  • Inlet Connection Diameter
  • 9/16 in.
  • Inlet to Outlet Width
  • 11.9 cm (4.7 in.)
  • Length
  • 4.7 in. (11.9 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 3
  • Maximum Differential Pressure
  • 80 psi (5.5 bar) continuous100 psi (6.9 bar) intermittent
  • Maximum Differential Pressure, bar (psid)
  • Forward: 6.9 bar (100 psid) intermittent @ 25 °C; 5.5 bar (80 psid) @ 25 °C; 1.0 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C, intermittent
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 6.9 bar (100 psi) intermittent @ 23 °C; 5.5 bar (80 psi) @ 23 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Millipore Express® SHC
  • Non-Fiber Releasing
  • This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Outlet Connection
  • Hose Barb with Bell
  • Outlet Connection Diameter
  • 9/16 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥1 L
  • Pore Size
  • 0.5 / 0.2 µm
  • Seal Material
  • Silicone (SI)
  • Sterility
  • Gamma
  • Sterilization
  • Gamma compatible to 45 kGy; 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
  • Support Material
  • Polyethylene
  • Trade Name
  • Millipore Express®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Gamma stable polypropylene (PP)
  • Wettability
  • Hydrophilic
  • Width
  • 11.9 cm (4.7 in.)
KHGEG003HB3 Opticap® Gamma Compatible XL 300 Millipore Express® SHC 0.5/0.2 µm 9/16 in. HB/HB with Bell 245 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Bacterial Retention
  • Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
  • Cartridge Nominal Length
  • 4.7 in. (11.9 cm)
  • Catalogue Number
  • KHGEG003HB3
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Capsule
  • Device Material
  • Gamma stable polypropylene/Polysulfone
  • Diameter
  • 5.6 cm (2.2 in.)
  • European Pressure Equipment Directive
  • EMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
  • Filtration Area
  • 290 cm²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Housing Material
  • Polypropylene (PP)
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Hose Barb
  • Inlet Connection Diameter
  • 9/16 in.
  • Inlet to Outlet Width
  • 11.9 cm (4.7 in.)
  • Length
  • 4.7 in. (11.9 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 3
  • Maximum Differential Pressure
  • 80 psi (5.5 bar) continuous100 psi (6.9 bar) intermittent
  • Maximum Differential Pressure, bar (psid)
  • Forward: 6.9 bar (100 psid) intermittent @ 25 °C; 5.5 bar (80 psid) @ 25 °C; 1.0 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C, intermittent
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 6.9 bar (100 psi) intermittent @ 23 °C; 5.5 bar (80 psi) @ 23 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Millipore Express® SHC
  • Non-Fiber Releasing
  • This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Outlet Connection
  • Hose Barb with Bell
  • Outlet Connection Diameter
  • 9/16 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥1 L
  • Pore Size
  • 0.5 / 0.2 µm
  • Seal Material
  • Silicone (SI)
  • Sterility
  • Gamma
  • Sterilization
  • Gamma compatible to 45 kGy; 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
  • Support Material
  • Polyethylene
  • Trade Name
  • Millipore Express®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Gamma stable polypropylene (PP)
  • Wettability
  • Hydrophilic
  • Width
  • 11.9 cm (4.7 in.)
CVVL75S01 Durapore® Cartridge Filter 5 in. 0.1 µm Code 7 247 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Bacterial Retention
  • Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
  • Cartridge Code
  • Code 7 (2-226) O-rings w/locking-tabs
  • Cartridge Nominal Length
  • 5 in. (12.5 cm)
  • Catalogue Number
  • CVVL75S01
  • Chemistry
  • Polyvinylidene Fluoride (PVDF)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Device Size
  • 5 in.
  • Diameter
  • 6.9 cm (2.7 in.)
  • Filtration Area
  • 0.35 m²
  • Flow Rate
  • 7.5 L/min @ 700 mbar ΔP
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182. All component materials meet the requirements of the EU framework regulation [1935/2004/EC] regarding materials and articles intended to contact food.
  • Length
  • 5 in. (12.5 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • Forward: 5.5 bar (80 psid) @ 25 °C; 1.7 bar (25 psid) @ 80 °C; 0.35 bar (5 psid) @ 135 °C. Reverse: 3.5 bar (50 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • Forward - 5.5 bar (80 psi) @ 25 °C; 1.7 bar (25 psi) @ 80 °C; 0.35 bar (5 psi) @ 135 °C; Reverse - 3.5 bar (50 psi) @ 25 °C
  • Media
  • Durapore®
  • Non-Fiber Releasing
  • This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥500 mL
  • Pore Size
  • 0.1 µm
  • Seal Material
  • Silicone (SI)
  • Sterility
  • Other
  • Sterilization
  • 30 SIP cycles of 30 min @ 135 °C; 30 autoclave cycles of 60 min @ 126 °C
  • Support Material
  • Polypropylene
  • Trade Name
  • Durapore®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Wettability
  • Hydrophilic

Overview

Analytical Sample Preparation Membrane Filtration Devices


Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.


Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.


Filter Membranes

Millex® Syringe Filters

Filtration Holders & Accessories



Resources