+852-3069 6950
css@gugent.com.hk
 

We have developed a unique portfolio of consumables, each adapted to the different feed water quality requirements and to your various applications. To maintain your water system’s performance, it’s critical to replace your purification cartridges on time and with genuine ISO 9001-certified parts.

Catalog No. Product Net Price
KHVES015HB3 Opticap® Sterile XL 150 Millipore Express® SHR with Prefilter 0.5/0.1 µm 9/16 in. HB/HB with Bell 272 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Bacterial Retention
  • Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
  • Cartridge Nominal Length
  • 3.8 in. (9.7 cm)
  • Catalogue Number
  • KHVES015HB3
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Capsule
  • Device Material
  • Gamma stable polypropylene/Polysulfone
  • Diameter
  • 10.9 cm (4.3 in.)
  • European Pressure Equipment Directive
  • EMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
  • Filtration Area
  • 200 cm²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Housing Material
  • Polypropylene (PP)
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Hose Barb
  • Inlet Connection Diameter
  • 9/16 in.
  • Inlet to Outlet Width
  • 9.7 cm (3.8 in.)
  • Length
  • 3.8 in. (9.7 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 3
  • Maximum Differential Pressure
  • 80 psi (5.5 bar) continuous100 psi (6.9 bar) intermittent
  • Maximum Differential Pressure, bar (psid)
  • Forward: 6.9 bar (100 psid) intermittent @ 25 °C; 5.5 bar (80 psid) @ 25 °C; 1.0 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C, intermittent
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 6.9 bar (100 psi) intermittent @ 25 °C; 5.5 bar (80 psi) @ 25 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Millipore Express® SHR w/Prefilter
  • Non-Fiber Releasing
  • This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Outlet Connection
  • Hose Barb with Bell
  • Outlet Connection Diameter
  • 9/16 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥1 L
  • Pore Size
  • 0.5 / 0.1 µm
  • Seal Material
  • Silicone (SI)
  • Sterility
  • Sterile
  • Sterilization
  • 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
  • Support Material
  • Polyester
  • Trade Name
  • Millipore Express®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Gamma stable polypropylene (PP)
  • Wettability
  • Hydrophilic
  • Width
  • 9.7 cm (3.8 in.)
CRA5F1C06 Polygard-CR Cartridge Filter 10 in. 0.5 µm Code F Short 274 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code F double open end w/flat gaskets
  • Cartridge Nominal Length
  • 10 in. (25 cm)
  • Catalogue Number
  • CRA5F1C06
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Gravimetric Extractables
  • ≤50 mg after 24-h soak in water
  • Length
  • 10 in. (25 cm)
  • Material Size
  • 6
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 0.5 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥5 L
  • Pore Size
  • 0.5 µm
  • Sanitization
  • 30 min with hot water @ 80 °C
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • Do not autoclave
  • Trade Name
  • Polygard®
  • Wettability
  • Hydrophilic
CRA5F1C06 Polygard-CR Cartridge Filter 10 in. 0.5 µm Code F Short 274 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code F double open end w/flat gaskets
  • Cartridge Nominal Length
  • 10 in. (25 cm)
  • Catalogue Number
  • CRA5F1C06
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Gravimetric Extractables
  • ≤50 mg after 24-h soak in water
  • Length
  • 10 in. (25 cm)
  • Material Size
  • 6
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 0.5 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥5 L
  • Pore Size
  • 0.5 µm
  • Sanitization
  • 30 min with hot water @ 80 °C
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • Do not autoclave
  • Trade Name
  • Polygard®
  • Wettability
  • Hydrophilic
CWL6M4S03 Milligard® Low Protein Binding Cartridge Filter 4 in. Code M 0.5 µm 274 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code M (2-118) O-rings
  • Cartridge Nominal Length
  • 4 in. (10 cm)
  • Catalogue Number
  • CWL6M4S03
  • Chemistry
  • Low Protein-Binding Mixed Cellulose Esters (MCE)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Device Size
  • 4 in.
  • Diameter
  • 7.1 cm (2.8 in.)
  • Filter Grade
  • Low Protein Binding Milligard® Media
  • Filtration Area
  • 0.32 m²
  • Format
  • Single Layer
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 40 mg per 4-inch cartridge after a 2 L flush and 24 hours in water at controlled room temperature.
  • Length
  • 4 in. (10 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 3
  • Maximum Differential Pressure, bar (psid)
  • 3.5 bar (50 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 3.5 bar (50 psi) @ 25 °C
  • Media
  • Maximum Differential Pressure, bar (psid)
  • Nominal Pore Size
  • 0.5 µm
  • Non-Fiber Releasing
  • This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥3 L
  • Pore Size
  • 0.5 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 10 autoclave cycles or SIP @ 121 °C for 30 min
  • Support Material
  • Polyester
  • Trade Name
  • Milligard®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
CWL6M4S03 Milligard® Low Protein Binding Cartridge Filter 4 in. Code M 0.5 µm 274 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code M (2-118) O-rings
  • Cartridge Nominal Length
  • 4 in. (10 cm)
  • Catalogue Number
  • CWL6M4S03
  • Chemistry
  • Low Protein-Binding Mixed Cellulose Esters (MCE)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Device Size
  • 4 in.
  • Diameter
  • 7.1 cm (2.8 in.)
  • Filter Grade
  • Low Protein Binding Milligard® Media
  • Filtration Area
  • 0.32 m²
  • Format
  • Single Layer
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 40 mg per 4-inch cartridge after a 2 L flush and 24 hours in water at controlled room temperature.
  • Length
  • 4 in. (10 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 3
  • Maximum Differential Pressure, bar (psid)
  • 3.5 bar (50 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 3.5 bar (50 psi) @ 25 °C
  • Media
  • Maximum Differential Pressure, bar (psid)
  • Nominal Pore Size
  • 0.5 µm
  • Non-Fiber Releasing
  • This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥3 L
  • Pore Size
  • 0.5 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 10 autoclave cycles or SIP @ 121 °C for 30 min
  • Support Material
  • Polyester
  • Trade Name
  • Milligard®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
KVGLA05TT1 Opticap® XL5 Durapore® 0.22 µm 1-1/2 in. TC/TC 274 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Bacterial Retention
  • Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
  • Cartridge Nominal Length
  • 5 in. (12.5 cm)
  • Catalogue Number
  • KVGLA05TT1
  • Chemistry
  • Polyvinylidene Fluoride (PVDF)
  • Device Configuration
  • Capsule
  • Device Material
  • Polypropylene
  • Device Size
  • 5 in.
  • Diameter
  • 14.5 cm (5.7 in.)
  • European Pressure Equipment Directive
  • EMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
  • Filtration Area
  • 0.35 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 15 mg per capsule after 24 hours in water at controlled room temperature.
  • Housing Material
  • Polypropylene (PP)
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Sanitary Flange
  • Inlet Connection Diameter
  • 1-1/2 in.
  • Inlet to Outlet Width
  • 21.6 cm (8.5 in.)
  • Length
  • 5 in. (12.5 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • Forward: 5.5 bar (80 psid) @ 25 °C; 1.0 bar (15 psid) @ 80 °C. Reverse: 3.4 bar (50 psid) @ 25 °C, intermittent
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 23 °C; 2.8 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Durapore®
  • Non-Fiber Releasing
  • This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Outlet Connection
  • Sanitary Flange
  • Outlet Connection Diameter
  • 1-1/2 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥500 mL
  • Pore Size
  • 0.22 µm
  • Seal Material
  • Silicone (SI)
  • Sterility
  • Other
  • Sterilization
  • 3 autoclave cycles of 60 min @ 126 °C; not in-line steam sterilizable
  • Support Material
  • Polypropylene
  • Trade Name
  • Opticap®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Polypropylene (PP)
  • Wettability
  • Hydrophilic
  • Width
  • 21.6 cm (8.5 in.)
KWLSA10FF1 Opticap® XL10 Milligard® Low Protein Binding 0.5/0.2 µm 3/4 in. TC/TC 274 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Nominal Length
  • 10 in. (25 cm)
  • Catalogue Number
  • KWLSA10FF1
  • Chemistry
  • Low Protein-Binding Mixed Cellulose Esters (MCE)
  • Device Configuration
  • Capsule
  • Device Material
  • Polypropylene
  • Device Size
  • 10 in.
  • Diameter
  • 14.5 cm (5.7 in.)
  • European Pressure Equipment Directive
  • EMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
  • Filter Grade
  • Low Protein Binding Milligard® Media
  • Filtration Area
  • 0.69 m²
  • Format
  • Double Layer
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 205 mg per capsule after a 5 L flush and 24 hours in water at controlled room temperature.
  • Housing Material
  • Polypropylene (PP)
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Sanitary Flange
  • Inlet Connection Diameter
  • 3/4 in.
  • Inlet to Outlet Width
  • 33.5 cm (13.2 in.)
  • Length
  • 10 in. (25 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 3.5 bar (50 psid) @ 25 °C
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 23 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Housing Material
  • Nominal Pore Size
  • 0.5 / 0.2 µm
  • Non-Fiber Releasing
  • This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Outlet Connection
  • Sanitary Flange
  • Outlet Connection Diameter
  • 3/4 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥5 L
  • Pore Size
  • 0.5 / 0.2 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 3 autoclave cycles of 30 min @ 121 °C; not in-line steam sterilizable
  • Support Material
  • Polyester
  • Trade Name
  • Opticap®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Polypropylene (PP)
  • Width
  • 33.5 cm (13.2 in.)
KWLSA10FF1 Opticap® XL10 Milligard® Low Protein Binding 0.5/0.2 µm 3/4 in. TC/TC 274 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Nominal Length
  • 10 in. (25 cm)
  • Catalogue Number
  • KWLSA10FF1
  • Chemistry
  • Low Protein-Binding Mixed Cellulose Esters (MCE)
  • Device Configuration
  • Capsule
  • Device Material
  • Polypropylene
  • Device Size
  • 10 in.
  • Diameter
  • 14.5 cm (5.7 in.)
  • European Pressure Equipment Directive
  • EMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
  • Filter Grade
  • Low Protein Binding Milligard® Media
  • Filtration Area
  • 0.69 m²
  • Format
  • Double Layer
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 205 mg per capsule after a 5 L flush and 24 hours in water at controlled room temperature.
  • Housing Material
  • Polypropylene (PP)
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Sanitary Flange
  • Inlet Connection Diameter
  • 3/4 in.
  • Inlet to Outlet Width
  • 33.5 cm (13.2 in.)
  • Length
  • 10 in. (25 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 3.5 bar (50 psid) @ 25 °C
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 23 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Housing Material
  • Nominal Pore Size
  • 0.5 / 0.2 µm
  • Non-Fiber Releasing
  • This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Outlet Connection
  • Sanitary Flange
  • Outlet Connection Diameter
  • 3/4 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥5 L
  • Pore Size
  • 0.5 / 0.2 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 3 autoclave cycles of 30 min @ 121 °C; not in-line steam sterilizable
  • Support Material
  • Polyester
  • Trade Name
  • Opticap®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Polypropylene (PP)
  • Width
  • 33.5 cm (13.2 in.)
KWSCA04HH3 Opticap® XL4 Milligard® 1.2/0.5 µm 9/16 in. HB/HB 275 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Nominal Length
  • 4 in. (10 cm)
  • Catalogue Number
  • KWSCA04HH3
  • Chemistry
  • Mixed Cellulose Esters (MCE)
  • Device Configuration
  • Capsule
  • Device Material
  • Polypropylene
  • Device Size
  • 4 in.
  • Diameter
  • 12.5 cm (4.9 in.)
  • European Pressure Equipment Directive
  • EMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
  • Filter Grade
  • Standard Milligard® Media
  • Filtration Area
  • 0.16 m²
  • Format
  • Double Layer
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 25 mg per capsule after 24 hours in water at controlled room temperature.
  • Housing Material
  • Polypropylene (PP)
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Hose Barb
  • Inlet Connection Diameter
  • 9/16 in.
  • Inlet to Outlet Width
  • 19.6 cm (7.7 in.)
  • Length
  • 4 in. (10 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 3
  • Maximum Differential Pressure, bar (psid)
  • 3.5 bar (50 psid) @ 25 °C
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 23 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Housing Material
  • Nominal Pore Size
  • 1.2 / 0.5 µm
  • Non-Fiber Releasing
  • This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Outlet Connection
  • Hose Barb
  • Outlet Connection Diameter
  • 9/16 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥1 L
  • Pore Size
  • 1.2 / 0.5 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 3 autoclave cycles of 30 min @ 121 °C; not in-line steam sterilizable
  • Support Material
  • Polyester
  • Trade Name
  • Opticap®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Polypropylene (PP)
  • Width
  • 19.6 cm (7.7 in.)
KWSCA04HH3 Opticap® XL4 Milligard® 1.2/0.5 µm 9/16 in. HB/HB 275 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Nominal Length
  • 4 in. (10 cm)
  • Catalogue Number
  • KWSCA04HH3
  • Chemistry
  • Mixed Cellulose Esters (MCE)
  • Device Configuration
  • Capsule
  • Device Material
  • Polypropylene
  • Device Size
  • 4 in.
  • Diameter
  • 12.5 cm (4.9 in.)
  • European Pressure Equipment Directive
  • EMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
  • Filter Grade
  • Standard Milligard® Media
  • Filtration Area
  • 0.16 m²
  • Format
  • Double Layer
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 25 mg per capsule after 24 hours in water at controlled room temperature.
  • Housing Material
  • Polypropylene (PP)
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Hose Barb
  • Inlet Connection Diameter
  • 9/16 in.
  • Inlet to Outlet Width
  • 19.6 cm (7.7 in.)
  • Length
  • 4 in. (10 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 3
  • Maximum Differential Pressure, bar (psid)
  • 3.5 bar (50 psid) @ 25 °C
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 23 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Housing Material
  • Nominal Pore Size
  • 1.2 / 0.5 µm
  • Non-Fiber Releasing
  • This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Outlet Connection
  • Hose Barb
  • Outlet Connection Diameter
  • 9/16 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥1 L
  • Pore Size
  • 1.2 / 0.5 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 3 autoclave cycles of 30 min @ 121 °C; not in-line steam sterilizable
  • Support Material
  • Polyester
  • Trade Name
  • Opticap®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Polypropylene (PP)
  • Width
  • 19.6 cm (7.7 in.)

Overview

Analytical Sample Preparation Membrane Filtration Devices


Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.


Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.


Filter Membranes

Millex® Syringe Filters

Filtration Holders & Accessories



Resources