+852-3069 6950
css@gugent.com.hk
 

We have developed a unique portfolio of consumables, each adapted to the different feed water quality requirements and to your various applications. To maintain your water system’s performance, it’s critical to replace your purification cartridges on time and with genuine ISO 9001-certified parts.

Catalog No. Product Net Price
CVBB73PK1 Vitipore® II Cartridge Filter 30 in. 0.45 µm Code 7 Special offer 
Add to Cart
  • Cartridge Code
  • Code 7 (2-226) O-rings w/locking-tabs
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • CVBB73PK1
  • Chemistry
  • Polyvinylidene Fluoride (PVDF)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Device Size
  • 30 in.
  • Diameter
  • 6.9 cm (2.7 in.)
  • Filtration Area
  • 2.34 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 23 mg per 10-inch cartridge after 24 hours in water at controlled room temperature.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182. All component materials meet the requirements of the EU framework regulation [1935/2004/EC] regarding materials and articles intended to contact food.
  • Key Applications
  • Food and BeverageBeerBottled WaterWine
  • Length
  • 30 in. (75 cm)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • Forward: 5.5 bar (80 psid) @ 25 °C; 1.7 bar (25 psid) @ 80 °C; 0.35 bar (5 psid) @ 109 °C. Reverse: 3.5 bar (50 psid) @ 25 °C, intermittent
  • Maximum Inlet Pressure, bar (psi)
  • Forward - 5.5 bar (80 psi) @ 25 °C; 1.7 bar (25 psi) @ 80 °C; 0.35 bar (5 psi) @ 109 °C. Reverse - 3.5 bar (50 psi) @ 25 °C, Intermittent
  • Media
  • Vitipore® II
  • Non-Fiber Releasing
  • This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Pore Size
  • 0.45 µm
  • Seal Material
  • Silicone (SI)
  • Sterility
  • Other
  • Sterilization
  • 100 SIP cycles of 30 min @ 109 °C; hot water sanitized 50 times for 30 min @ 80 °C maximum
  • Support Material
  • Polypropylene
  • Trade Name
  • Vitipore®
  • Wettability
  • Hydrophilic
CVBB73PK1 Vitipore® II Cartridge Filter 30 in. 0.45 µm Code 7 Special offer 
Add to Cart
  • Cartridge Code
  • Code 7 (2-226) O-rings w/locking-tabs
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • CVBB73PK1
  • Chemistry
  • Polyvinylidene Fluoride (PVDF)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Device Size
  • 30 in.
  • Diameter
  • 6.9 cm (2.7 in.)
  • Filtration Area
  • 2.34 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 23 mg per 10-inch cartridge after 24 hours in water at controlled room temperature.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182. All component materials meet the requirements of the EU framework regulation [1935/2004/EC] regarding materials and articles intended to contact food.
  • Key Applications
  • Food and BeverageBeerBottled WaterWine
  • Length
  • 30 in. (75 cm)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • Forward: 5.5 bar (80 psid) @ 25 °C; 1.7 bar (25 psid) @ 80 °C; 0.35 bar (5 psid) @ 109 °C. Reverse: 3.5 bar (50 psid) @ 25 °C, intermittent
  • Maximum Inlet Pressure, bar (psi)
  • Forward - 5.5 bar (80 psi) @ 25 °C; 1.7 bar (25 psi) @ 80 °C; 0.35 bar (5 psi) @ 109 °C. Reverse - 3.5 bar (50 psi) @ 25 °C, Intermittent
  • Media
  • Vitipore® II
  • Non-Fiber Releasing
  • This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Pore Size
  • 0.45 µm
  • Seal Material
  • Silicone (SI)
  • Sterility
  • Other
  • Sterilization
  • 100 SIP cycles of 30 min @ 109 °C; hot water sanitized 50 times for 30 min @ 80 °C maximum
  • Support Material
  • Polypropylene
  • Trade Name
  • Vitipore®
  • Wettability
  • Hydrophilic
CVBB73PK3 Vitipore® II Cartridge Filter 30 in. 0.45 µm Code 7 Special offer 
Add to Cart
  • Cartridge Code
  • Code 7 (2-226) O-rings w/locking-tabs
  • Cartridge Nominal Length
  • 40 in. (100 cm)
  • Catalogue Number
  • CVBB73PK3
  • Chemistry
  • Polyvinylidene Fluoride (PVDF)
  • Device Configuration
  • Cartridge
  • Device Size
  • 30 in.
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 23 mg per 10-inch cartridge after 24 hours in water at controlled room temperature.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182. All component materials meet the requirements of the EU framework regulation [1935/2004/EC] regarding materials and articles intended to contact food.
  • Key Applications
  • Food and BeverageBeerBottled WaterWine
  • Length
  • 40 in. (100 cm)
  • Material Size
  • 3
  • Media
  • Vitipore® II
  • Non-Fiber Releasing
  • This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Pore Size
  • 0.45 µm
  • Sterility
  • Other
  • Trade Name
  • Vitipore® II
  • Wettability
  • Hydrophilic
CVBH71PK1 Brewpore® Cartridge Filter 10 in. 0.55 µm Code 7 Special offer 
Add to Cart
  • Bacterial Retention
  • Microbial titer reduction >1011 CFU/cartridge when challenged with Saccharomyces cerevisae; >107 CFU/cartridge with Pediococcus damnosus; >106 CFU/cartridge with Lactobacillus brevis
  • Cartridge Code
  • Code 7 (2-226) O-rings w/locking-tabs
  • Cartridge Nominal Length
  • 10 in. (25 cm)
  • Catalogue Number
  • CVBH71PK1
  • Chemistry
  • Hydrophobic Polyvinylidene Fluoride (PVDF)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 6.9 cm (2.7 in.)
  • Filtration Area
  • 0.75 m²
  • Flow Rate
  • 20 L/min @ 330 mbar ΔP
  • Key Applications
  • Food and BeverageBeerBottled WaterWine
  • Length
  • 10 in. (25 cm)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • Forward: 5.5 bar (80 psid) @ 25 °C; 1.7 bar (25 psid) @ 80 °C; 0.35 bar (5 psid) @ 121 °C. Reverse: 3.5 bar (50 psid) @ 25 °C, intermittent; 0.35 bar (5 psid) @ 121 °C
  • Maximum Inlet Pressure, bar (psi)
  • Forward - 5.5 bar (80 psi) @ 25 °C; 1.7 bar (25 psi) @ 80 °C; 0.35 bar (5 psi) @ 121 °C. Reverse - 3.5 bar (50 psi) @ 25 °C, Intermittent; 0.35 bar (5 psi) @ 121 °C
  • Media
  • Durapore®
  • Pore Size
  • 0.55 µm
  • Seal Material
  • Silicone (SI)
  • Sterility
  • Other
  • Sterilization
  • 100 SIP cycles of 30 min @ 109 °C; hot water sanitized 50 times for 30 min @ 80 °C maximum
  • Support Material
  • Polypropylene
  • Trade Name
  • Brewpore®
  • Wettability
  • Hydrophobic
CVBH71PK1 Brewpore® Cartridge Filter 10 in. 0.55 µm Code 7 Special offer 
Add to Cart
  • Bacterial Retention
  • Microbial titer reduction >1011 CFU/cartridge when challenged with Saccharomyces cerevisae; >107 CFU/cartridge with Pediococcus damnosus; >106 CFU/cartridge with Lactobacillus brevis
  • Cartridge Code
  • Code 7 (2-226) O-rings w/locking-tabs
  • Cartridge Nominal Length
  • 10 in. (25 cm)
  • Catalogue Number
  • CVBH71PK1
  • Chemistry
  • Hydrophobic Polyvinylidene Fluoride (PVDF)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 6.9 cm (2.7 in.)
  • Filtration Area
  • 0.75 m²
  • Flow Rate
  • 20 L/min @ 330 mbar ΔP
  • Key Applications
  • Food and BeverageBeerBottled WaterWine
  • Length
  • 10 in. (25 cm)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • Forward: 5.5 bar (80 psid) @ 25 °C; 1.7 bar (25 psid) @ 80 °C; 0.35 bar (5 psid) @ 121 °C. Reverse: 3.5 bar (50 psid) @ 25 °C, intermittent; 0.35 bar (5 psid) @ 121 °C
  • Maximum Inlet Pressure, bar (psi)
  • Forward - 5.5 bar (80 psi) @ 25 °C; 1.7 bar (25 psi) @ 80 °C; 0.35 bar (5 psi) @ 121 °C. Reverse - 3.5 bar (50 psi) @ 25 °C, Intermittent; 0.35 bar (5 psi) @ 121 °C
  • Media
  • Durapore®
  • Pore Size
  • 0.55 µm
  • Seal Material
  • Silicone (SI)
  • Sterility
  • Other
  • Sterilization
  • 100 SIP cycles of 30 min @ 109 °C; hot water sanitized 50 times for 30 min @ 80 °C maximum
  • Support Material
  • Polypropylene
  • Trade Name
  • Brewpore®
  • Wettability
  • Hydrophobic
CVBH72PK1 Brewpore® Cartridge Filter 20 in. 0.55 µm Code 7 Special offer 
Add to Cart
  • Cartridge Code
  • Code 7 (2-226) O-rings w/locking-tabs
  • Cartridge Nominal Length
  • 20 in. (50 cm)
  • Catalogue Number
  • CVBH72PK1
  • Chemistry
  • Polyvinylidene Fluoride (PVDF)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Device Size
  • 20 in.
  • Diameter
  • 6.9 cm (2.7 in.)
  • Filtration Area
  • 1.5 m²
  • Flow Rate
  • 40 L/min @ 330 mbar ΔP
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 30 mg per 10-inch cartridge after 24 hours in a 70/30% IPA/water mixture at controlled room temperature.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182. All component materials meet the requirements of the EU framework regulation [1935/2004/EC] regarding materials and articles intended to contact food.
  • Key Applications
  • Food and BeverageBeerBottled WaterWine
  • Length
  • 20 in. (50 cm)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • Forward: 5.5 bar (80 psid) @ 25 °C; 1.7 bar (25 psid) @ 80 °C; 0.35 bar (5 psid) @ 121 °C. Reverse: 3.5 bar (50 psid) @ 25 °C, intermittent; 0.35 bar (5 psid) @ 121 °C
  • Maximum Inlet Pressure, bar (psi)
  • Forward - 5.5 bar (80 psi) @ 25 °C; 1.7 bar (25 psi) @ 80 °C; 0.35 bar (5 psi) @ 121 °C. Reverse - 3.5 bar (50 psi) @ 25 °C, Intermittent; 0.35 bar (5 psi) @ 121 °C
  • Media
  • Brewpore®
  • Non-Fiber Releasing
  • This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Pore Size
  • 0.55 µm
  • Seal Material
  • Silicone (SI)
  • Sterility
  • Other
  • Sterilization
  • 100 SIP cycles of 30 min @ 109 °C; hot water sanitized 50 times for 30 min @ 80 °C maximum
  • Support Material
  • Polypropylene
  • Trade Name
  • Brewpore®
  • Wettability
  • Hydrophobic
CVBH72PK1 Brewpore® Cartridge Filter 20 in. 0.55 µm Code 7 Special offer 
Add to Cart
  • Cartridge Code
  • Code 7 (2-226) O-rings w/locking-tabs
  • Cartridge Nominal Length
  • 20 in. (50 cm)
  • Catalogue Number
  • CVBH72PK1
  • Chemistry
  • Polyvinylidene Fluoride (PVDF)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Device Size
  • 20 in.
  • Diameter
  • 6.9 cm (2.7 in.)
  • Filtration Area
  • 1.5 m²
  • Flow Rate
  • 40 L/min @ 330 mbar ΔP
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 30 mg per 10-inch cartridge after 24 hours in a 70/30% IPA/water mixture at controlled room temperature.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182. All component materials meet the requirements of the EU framework regulation [1935/2004/EC] regarding materials and articles intended to contact food.
  • Key Applications
  • Food and BeverageBeerBottled WaterWine
  • Length
  • 20 in. (50 cm)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • Forward: 5.5 bar (80 psid) @ 25 °C; 1.7 bar (25 psid) @ 80 °C; 0.35 bar (5 psid) @ 121 °C. Reverse: 3.5 bar (50 psid) @ 25 °C, intermittent; 0.35 bar (5 psid) @ 121 °C
  • Maximum Inlet Pressure, bar (psi)
  • Forward - 5.5 bar (80 psi) @ 25 °C; 1.7 bar (25 psi) @ 80 °C; 0.35 bar (5 psi) @ 121 °C. Reverse - 3.5 bar (50 psi) @ 25 °C, Intermittent; 0.35 bar (5 psi) @ 121 °C
  • Media
  • Brewpore®
  • Non-Fiber Releasing
  • This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Pore Size
  • 0.55 µm
  • Seal Material
  • Silicone (SI)
  • Sterility
  • Other
  • Sterilization
  • 100 SIP cycles of 30 min @ 109 °C; hot water sanitized 50 times for 30 min @ 80 °C maximum
  • Support Material
  • Polypropylene
  • Trade Name
  • Brewpore®
  • Wettability
  • Hydrophobic
CVBW03PK1 Vitipore® II Cartridge Filter 30 in. 0.22 µm Code 0 Special offer 
Add to Cart
  • Cartridge Code
  • Code 0 (2-222) O-rings
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • CVBW03PK1
  • Chemistry
  • Polyvinylidene Fluoride (PVDF)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Device Size
  • 30 in.
  • Diameter
  • 6.9 cm (2.7 in.)
  • Filtration Area
  • 2.34 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 23 mg per 10-inch cartridge after 24 hours in water at controlled room temperature.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182. All component materials meet the requirements of the EU framework regulation [1935/2004/EC] regarding materials and articles intended to contact food.
  • Key Applications
  • Food and BeverageBeerBottled WaterWine
  • Length
  • 30 in. (75 cm)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • Forward: 5.5 bar (80 psid) @ 25 °C; 1.7 bar (25 psid) @ 80 °C; 0.35 bar (5 psid) @ 135 °C. Reverse: 3.5 bar (50 psid) @ 25 °C, intermittent
  • Maximum Inlet Pressure, bar (psi)
  • Forward - 5.5 bar (80 psi ) @ 25 °C; 1.7 bar (25 psi) @ 80 °C; 0.35 bar (5 psi) @ 135 °C. Reverse - 3.5 bar (50 psi) @ 25 °C, Intermittent
  • Media
  • Vitipore® II
  • Non-Fiber Releasing
  • This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Pore Size
  • 0.22 µm
  • Seal Material
  • Silicone (SI)
  • Sterility
  • Other
  • Sterilization
  • 100 SIP cycles of 30 min @ 109 °C; hot water sanitized 30 times for 30 min @ 80 °C maximum
  • Support Material
  • Polypropylene
  • Trade Name
  • Vitipore®
  • Wettability
  • Hydrophilic
CVBW51PK1 Vitipore® II Cartridge Filter 10 in. 0.22 µm Code 5 Special offer 
Add to Cart
  • Bacterial Retention
  • Quantitative retention of 107 CFU/cm2 Pseudomonas aeruginosa and Escherichia coli
  • Cartridge Code
  • Code 5 (2-222) O-rings and spear
  • Cartridge Nominal Length
  • 10 in. (25 cm)
  • Catalogue Number
  • CVBW51PK1
  • Chemistry
  • Polyvinylidene Fluoride (PVDF) Hydrophilic
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 6.9 cm (2.7 in.)
  • Filtration Area
  • 0.78 m²
  • Key Applications
  • Food and BeverageBeerBottled WaterWine
  • Length
  • 10 in. (25 cm)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • Forward: 5.5 bar (80 psid) @ 25 °C; 1.7 bar (25 psid) @ 80 °C; 0.35 bar (5 psid) @ 135 °C. Reverse: 3.5 bar (50 psid) @ 25 °C, intermittent
  • Maximum Inlet Pressure, bar (psi)
  • Forward - 5.5 bar (80 psi ) @ 25 °C; 1.7 bar (25 psi) @ 80 °C; 0.35 bar (5 psi) @ 135 °C. Reverse - 3.5 bar (50 psi) @ 25 °C, Intermittent
  • Media
  • Durapore®
  • Pore Size
  • 0.22 µm
  • Seal Material
  • Silicone (SI)
  • Sterility
  • Other
  • Sterilization
  • 100 SIP cycles of 30 min @ 109 °C; hot water sanitized 30 times for 30 min @ 80 °C maximum
  • Support Material
  • Polypropylene
  • Trade Name
  • Vitipore®
  • Wettability
  • Hydrophilic
CVBW51PK1 Vitipore® II Cartridge Filter 10 in. 0.22 µm Code 5 Special offer 
Add to Cart
  • Bacterial Retention
  • Quantitative retention of 107 CFU/cm2 Pseudomonas aeruginosa and Escherichia coli
  • Cartridge Code
  • Code 5 (2-222) O-rings and spear
  • Cartridge Nominal Length
  • 10 in. (25 cm)
  • Catalogue Number
  • CVBW51PK1
  • Chemistry
  • Polyvinylidene Fluoride (PVDF) Hydrophilic
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 6.9 cm (2.7 in.)
  • Filtration Area
  • 0.78 m²
  • Key Applications
  • Food and BeverageBeerBottled WaterWine
  • Length
  • 10 in. (25 cm)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • Forward: 5.5 bar (80 psid) @ 25 °C; 1.7 bar (25 psid) @ 80 °C; 0.35 bar (5 psid) @ 135 °C. Reverse: 3.5 bar (50 psid) @ 25 °C, intermittent
  • Maximum Inlet Pressure, bar (psi)
  • Forward - 5.5 bar (80 psi ) @ 25 °C; 1.7 bar (25 psi) @ 80 °C; 0.35 bar (5 psi) @ 135 °C. Reverse - 3.5 bar (50 psi) @ 25 °C, Intermittent
  • Media
  • Durapore®
  • Pore Size
  • 0.22 µm
  • Seal Material
  • Silicone (SI)
  • Sterility
  • Other
  • Sterilization
  • 100 SIP cycles of 30 min @ 109 °C; hot water sanitized 30 times for 30 min @ 80 °C maximum
  • Support Material
  • Polypropylene
  • Trade Name
  • Vitipore®
  • Wettability
  • Hydrophilic

Overview

Analytical Sample Preparation Membrane Filtration Devices


Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.


Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.


Filter Membranes

Millex® Syringe Filters

Filtration Holders & Accessories



Resources