We have developed a unique portfolio of consumables, each adapted to the different feed water quality requirements and to your various applications. To maintain your water system’s performance, it’s critical to replace your purification cartridges on time and with genuine ISO 9001-certified parts.
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Nominal Length
5 in. (12.5 cm)
Catalogue Number
KW03A05TT1
Chemistry
Mixed Cellulose Esters (MCE)
Device Configuration
Capsule
Device Material
Polypropylene
Device Size
5 in.
Diameter
14.5 cm (5.7 in.)
European Pressure Equipment Directive
EMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
Filter Grade
Standard Milligard® Media
Filtration Area
0.34 m²
Format
Single Layer
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 25 mg per capsule after 24 hours in water at controlled room temperature.
Housing Material
Polypropylene (PP)
Indirect Food Additive
All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
Inlet Connection
Sanitary Flange
Inlet Connection Diameter
1-1/2 in.
Inlet to Outlet Width
21.6 cm (8.5 in.)
Length
5 in. (12.5 cm)
Material Package
Double Easy-Open bag
Material Size
1
Maximum Differential Pressure, bar (psid)
3.5 bar (50 psid) @ 25 °C
Maximum Inlet Pressure (psig)
80 psig
Maximum Inlet Pressure, bar (psi)
5.5 bar (80 psi) @ 23 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
Maximum Inlet Temperature
25 °C
Media
Housing Material
Nominal Pore Size
0.2 µm
Non-Fiber Releasing
This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Outlet Connection
Sanitary Flange
Outlet Connection Diameter
1-1/2 in.
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥2 L
Pore Size
0.2 µm
Seal Material
Silicone (SI)
Sterilization
3 autoclave cycles of 30 min @ 121 °C; not in-line steam sterilizable
Support Material
Polyester
Trade Name
Opticap®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Nominal Length
2 in. (5 cm)
Catalogue Number
KW06A02HH3
Chemistry
Mixed Cellulose Esters (MCE)
Device Configuration
Capsule
Device Material
Polypropylene
Device Size
2 in.
Diameter
12.5 cm (4.9 in.)
European Pressure Equipment Directive
EMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
Filter Grade
Standard Milligard® Media
Filtration Area
0.1 m²
Format
Single Layer
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 15 mg per capsule after 24 hours in water at controlled room temperature.
Housing Material
Polypropylene (PP)
Indirect Food Additive
All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
Inlet Connection
Hose Barb
Inlet Connection Diameter
9/16 in.
Inlet to Outlet Width
14.2 cm (5.6 in.)
Length
2 in. (5 cm)
Material Package
Double Easy-Open bag
Material Size
3
Maximum Differential Pressure, bar (psid)
3.5 bar (50 psid) @ 25 °C
Maximum Inlet Pressure (psig)
80 psig
Maximum Inlet Pressure, bar (psi)
5.5 bar (80 psi) @ 23 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
Maximum Inlet Temperature
25 °C
Media
Housing Material
Nominal Pore Size
0.5 µm
Non-Fiber Releasing
This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Outlet Connection
Hose Barb
Outlet Connection Diameter
9/16 in.
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥1 L
Pore Size
0.5 µm
Seal Material
Silicone (SI)
Sterilization
3 autoclave cycles of 30 min @ 121 °C; not in-line steam sterilizable
Support Material
Polyester
Trade Name
Opticap®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Nominal Length
2 in. (5 cm)
Catalogue Number
KW06A02TT3
Chemistry
Mixed Cellulose Esters (MCE)
Device Configuration
Capsule
Device Material
Polypropylene
Device Size
2 in.
Diameter
12.5 cm (4.9 in.)
European Pressure Equipment Directive
EMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
Filter Grade
Standard Milligard® Media
Filtration Area
0.1 m²
Format
Single Layer
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 15 mg per capsule after 24 hours in water at controlled room temperature.
Housing Material
Polypropylene (PP)
Indirect Food Additive
All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
Inlet Connection
Sanitary Flange
Inlet Connection Diameter
1-1/2 in.
Inlet to Outlet Width
14.2 cm (5.6 in.)
Length
2 in. (5 cm)
Material Package
Double Easy-Open bag
Material Size
3
Maximum Differential Pressure, bar (psid)
3.5 bar (50 psid) @ 25 °C
Maximum Inlet Pressure (psig)
80 psig
Maximum Inlet Pressure, bar (psi)
5.5 bar (80 psi) @ 23 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
Maximum Inlet Temperature
25 °C
Media
Housing Material
Nominal Pore Size
0.5 µm
Non-Fiber Releasing
This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Outlet Connection
Sanitary Flange
Outlet Connection Diameter
1-1/2 in.
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥1 L
Pore Size
0.5 µm
Seal Material
Silicone (SI)
Sterilization
3 autoclave cycles of 30 min @ 121 °C; not in-line steam sterilizable
Support Material
Polyester
Trade Name
Opticap®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Nominal Length
4 in. (10 cm)
Catalogue Number
KW06A04TT3
Chemistry
Mixed Cellulose Esters (MCE)
Device Configuration
Capsule
Device Material
Polypropylene
Device Size
4 in.
Diameter
12.5 cm (4.9 in.)
European Pressure Equipment Directive
EMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
Filter Grade
Standard Milligard® Media
Filtration Area
0.2 m²
Format
Single Layer
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 25 mg per capsule after 24 hours in water at controlled room temperature.
Housing Material
Polypropylene (PP)
Indirect Food Additive
All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
Inlet Connection
Sanitary Flange
Inlet Connection Diameter
1-1/2 in.
Inlet to Outlet Width
19.6 cm (7.7 in.)
Length
4 in. (10 cm)
Material Package
Double Easy-Open bag
Material Size
3
Maximum Differential Pressure, bar (psid)
3.5 bar (50 psid) @ 25 °C
Maximum Inlet Pressure (psig)
80 psig
Maximum Inlet Pressure, bar (psi)
5.5 bar (80 psi) @ 23 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
Maximum Inlet Temperature
25 °C
Media
Housing Material
Nominal Pore Size
0.5 µm
Non-Fiber Releasing
This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Outlet Connection
Sanitary Flange
Outlet Connection Diameter
1-1/2 in.
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥1 L
Pore Size
0.5 µm
Seal Material
Silicone (SI)
Sterilization
3 autoclave cycles of 30 min @ 121 °C; not in-line steam sterilizable
Support Material
Polyester
Trade Name
Opticap®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Nominal Length
5 in. (12.5 cm)
Catalogue Number
KWSCA05HH1
Chemistry
Mixed Cellulose Esters (MCE)
Device Configuration
Capsule
Device Material
Polypropylene
Device Size
5 in.
Diameter
14.5 cm (5.7 in.)
European Pressure Equipment Directive
EMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
Filter Grade
Standard Milligard® Media
Filtration Area
0.28 m²
Format
Double Layer
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 25 mg per capsule after 24 hours in water at controlled room temperature.
Housing Material
Polypropylene (PP)
Indirect Food Additive
All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
Inlet Connection
Hose Barb
Inlet Connection Diameter
9/16 in.
Inlet to Outlet Width
21.6 cm (8.5 in.)
Length
5 in. (12.5 cm)
Material Package
Double Easy-Open bag
Material Size
1
Maximum Differential Pressure, bar (psid)
3.5 bar (50 psid) @ 25 °C
Maximum Inlet Pressure (psig)
80 psig
Maximum Inlet Pressure, bar (psi)
5.5 bar (80 psi) @ 23 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
Maximum Inlet Temperature
25 °C
Media
Housing Material
Nominal Pore Size
1.2 / 0.5 µm
Non-Fiber Releasing
This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Outlet Connection
Hose Barb
Outlet Connection Diameter
9/16 in.
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥2 L
Pore Size
1.2 / 0.5 µm
Seal Material
Silicone (SI)
Sterilization
3 autoclave cycles of 30 min @ 121 °C; not in-line steam sterilizable
Support Material
Polyester
Trade Name
Opticap®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Nominal Length
20 in. (50 cm)
Catalogue Number
KWSCA2TTT1
Chemistry
Mixed Cellulose Esters (MCE)
Device Configuration
Capsule
Device Material
Polypropylene
Device Size
20 in.
Diameter
1-1/2 in.
European Pressure Equipment Directive
EMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
Filter Grade
Standard Milligard® Media
Filtration Area
1.38 m²
Format
Double Layer
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 110 mg per capsule after 24 hours in water at controlled room temperature.
Housing Material
Polypropylene (PP)
Indirect Food Additive
All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
Inlet Connection
Sanitary Flange
Inlet Connection Diameter
1-1/2 in.
Inlet to Outlet Width
15.2 cm (6.0 in.)
Length
20 in. (50 cm)
Material Package
Double Easy-Open bag
Material Size
1
Maximum Differential Pressure, bar (psid)
3.5 bar (50 psid) @ 25 °C
Maximum Inlet Pressure (psig)
80 psig
Maximum Inlet Pressure, bar (psi)
5.5 bar (80 psi) @ 23 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
Maximum Inlet Temperature
25 °C
Media
Housing Material
Nominal Pore Size
1.2 / 0.5 µm
Non-Fiber Releasing
This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Outlet Connection
Sanitary Flange
Outlet Connection Diameter
1-1/2 in.
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥10 L
Pore Size
1.2 / 0.5 µm
Seal Material
Silicone (SI)
Sterilization
3 autoclave cycles of 30 min @ 121 °C; not in-line steam sterilizable
Support Material
Polyester
Trade Name
Opticap®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Catalogue Number
MPHL10CA3
Chemistry
Polyvinylidene Fluoride (PVDF)
Device Configuration
Capsule
Device Material
Polycarbonate
Diameter
9/16 in.
Filtration Area
500 cm²
Flow Rate
23 L/min @ 2.6 bar ΔP
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 2.5 mg per device after 24 hours in water at controlled room temperature.
Inlet Connection
Hose Barb
Inlet Connection Diameter
9/16 in.
Material Package
Double Easy-Open bag
Material Size
3
Maximum Differential Pressure, bar (psid)
Forward: 4.1 bar (60 psid) @ 25 °C; 1.7 bar (25 psid) @ 80 °C; 0.35 bar (5 psid) @ 123 °C; Reverse: 0.7 bar (10 psid) @ 25 °C
Maximum Inlet Pressure, bar (psi)
5.2 bar (75 psi) @ 25 °C
Media
Durapore®
Non-Fiber Releasing
This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Outlet Connection
Hose Barb
Outlet Connection Diameter
9/16 in.
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥200 mL
Pore Size
0.45 µm
Process Volume
50 L
Sterility
Other
Sterilization
3 autoclave cycles of 90 min @ 123°C; not in-line steam sterilizable
Support Material
Polycarbonate
Trade Name
Millipak®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.
Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.