+852-3069 6950
css@gugent.com.hk
 

We have developed a unique portfolio of consumables, each adapted to the different feed water quality requirements and to your various applications. To maintain your water system’s performance, it’s critical to replace your purification cartridges on time and with genuine ISO 9001-certified parts.

Catalog No. Product Net Price
D00202E01 Clarigard Cartridge Filter 20 in. 0.2 µm Code 0 Ethylene-Propylene 60000000 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 0 (2-222) O-rings
  • Cartridge Nominal Length
  • 20 in. (50 cm)
  • Catalogue Number
  • D00202E01
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Gravimetric Extractables
  • ≤20 mg after 24-h soak in water
  • Length
  • 20 in. (50 cm)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 0.2 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥6 L
  • Pore Size
  • 0.2 µm
  • Seal Material
  • Ethylene Propylene
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Clarigard®
  • Wettability
  • Hydrophilic
D00202T01 Clarigard Cartridge Filter 20 in. 0.2 µm Code 0 PTFE-encapsulated Fluoroelastomer 60000000 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 0 (2-222) O-rings
  • Cartridge Nominal Length
  • 20 in. (50 cm)
  • Catalogue Number
  • D00202T01
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Gravimetric Extractables
  • ≤20 mg after 24-h soak in water
  • Length
  • 20 in. (50 cm)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 0.2 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥6 L
  • Pore Size
  • 0.2 µm
  • Seal Material
  • Polytetrafluoroethylene (PTFE)
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Clarigard®
  • Wettability
  • Hydrophilic
D00202V01 Clarigard Cartridge Filter 20 in. 0.2 µm Code 0 Fluoroelastomer 60000000 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 0 (2-222) O-rings
  • Cartridge Nominal Length
  • 20 in. (50 cm)
  • Catalogue Number
  • D00202V01
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Gravimetric Extractables
  • ≤20 mg after 24-h soak in water
  • Length
  • 20 in. (50 cm)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 0.2 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥6 L
  • Pore Size
  • 0.2 µm
  • Seal Material
  • Fluorocarbon rubber
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Clarigard®
  • Wettability
  • Hydrophilic
MK108170 Thioacetamide Special offer 
Add to Cart
  • Catalogue Number
  • 108170
  • HS Code
  • 2930 90 98
  • Storage
  • Store below +30°C.
  • Storage class
  • 6.1C Combustible, acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
MK504528 NVP-AAM077 Tetrasodium Hydrate - CAS 459836-30-7 - Calbiochem Special offer 
Add to Cart
  • Catalogue Number
  • 504528
  • Overview
  • A potent antagonist for NMDA receptors. Modestly higher selectivity for the NR2A than for the NR2B containing NMDA receptors (IC50 = 0.015 and 0.078 µM) but insufficient to discriminate between NR2A and NR2B-containing NMDA receptors. Widely used for researches in synaptic plastic, learning and memory, and epilepsy.
  • Storage
  • -20°C Protect from Light
CB0173006 CB Filter 1.0 µm Code 7 30 in. Special offer 
Add to Cart
  • Availability by Geography
  • Available for sale in Japan only
  • Cartridge Code
  • Code 7 (2-226) O-rings w/locking-tabs
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • CB0173006
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Filtration Area
  • 0.15 m²
  • Length
  • 30 in. (75 cm)
  • Material Size
  • 6
  • Maximum Differential Pressure, bar (psid)
  • 483 bar @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 483 bar @ 25 °C
  • Nominal Pore Size
  • 1.0 µm
  • Pore Size
  • 1.0 µm
  • Sanitization
  • 30 min with hot water @ 80 °C
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • Hot water sanitized @ 80 °C for 30 min
  • Support Material
  • Polypropylene
  • Wettability
  • Hydrophilic
CE0172S06 Polygard® CE Cartridge Filter 20 in. 1.0 µm Code 7 Silicone Special offer 
Add to Cart
  • Cartridge Code
  • Code 7 (2-226) O-rings w/locking-tabs
  • Cartridge Nominal Length
  • 20 in. (50 cm)
  • Catalogue Number
  • CE0172S06
  • Chemistry
  • Polypropylene (PP)Borosilicate Glass Fiber (BGF)Inorganic Filter Aid
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Filtration Area
  • 0.6 m²
  • Length
  • 20 in. (50 cm)
  • Material Size
  • 6
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 1.0 µm
  • Pore Size
  • 1.0 µm
  • Sanitization
  • 30 min with hot water @ 80 °C
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 5 autoclave cycles or SIP @ 121 °C for 30 min
  • Trade Name
  • Polygard®
  • Wettability
  • Hydrophilic
CE0172S06 Polygard® CE Cartridge Filter 20 in. 1.0 µm Code 7 Silicone Special offer 
Add to Cart
  • Cartridge Code
  • Code 7 (2-226) O-rings w/locking-tabs
  • Cartridge Nominal Length
  • 20 in. (50 cm)
  • Catalogue Number
  • CE0172S06
  • Chemistry
  • Polypropylene (PP)Borosilicate Glass Fiber (BGF)Inorganic Filter Aid
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Filtration Area
  • 0.6 m²
  • Length
  • 20 in. (50 cm)
  • Material Size
  • 6
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 1.0 µm
  • Pore Size
  • 1.0 µm
  • Sanitization
  • 30 min with hot water @ 80 °C
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 5 autoclave cycles or SIP @ 121 °C for 30 min
  • Trade Name
  • Polygard®
  • Wettability
  • Hydrophilic
CE0173S06 Polygard® CE Cartridge Filter 30 in. 1.0 µm Code 7 Silicone Special offer 
Add to Cart
  • Cartridge Code
  • Code 7 (2-226) O-rings w/locking-tabs
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • CE0173S06
  • Chemistry
  • Polypropylene (PP)Borosilicate Glass Fiber (BGF)Inorganic Filter Aid
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Filtration Area
  • 0.9 m²
  • Length
  • 30 in. (75 cm)
  • Material Size
  • 6
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 1.0 µm
  • Pore Size
  • 1.0 µm
  • Sanitization
  • 30 min with hot water @ 80 °C
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 5 autoclave cycles or SIP @ 121 °C for 30 min
  • Trade Name
  • Polygard®
  • Wettability
  • Hydrophilic
CE0173S06 Polygard® CE Cartridge Filter 30 in. 1.0 µm Code 7 Silicone Special offer 
Add to Cart
  • Cartridge Code
  • Code 7 (2-226) O-rings w/locking-tabs
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • CE0173S06
  • Chemistry
  • Polypropylene (PP)Borosilicate Glass Fiber (BGF)Inorganic Filter Aid
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Filtration Area
  • 0.9 m²
  • Length
  • 30 in. (75 cm)
  • Material Size
  • 6
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 1.0 µm
  • Pore Size
  • 1.0 µm
  • Sanitization
  • 30 min with hot water @ 80 °C
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 5 autoclave cycles or SIP @ 121 °C for 30 min
  • Trade Name
  • Polygard®
  • Wettability
  • Hydrophilic

Overview

Analytical Sample Preparation Membrane Filtration Devices


Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.


Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.


Filter Membranes

Millex® Syringe Filters

Filtration Holders & Accessories



Resources