+852-3069 6950
css@gugent.com.hk
 

We have developed a unique portfolio of consumables, each adapted to the different feed water quality requirements and to your various applications. To maintain your water system’s performance, it’s critical to replace your purification cartridges on time and with genuine ISO 9001-certified parts.

Catalog No. Product Net Price
CRA503006 Polygard-CR Cartridge Filter 30 in. 0.5 µm Code 0 Silicone 1104 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 0 (2-222) O-rings
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • CRA503006
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Gravimetric Extractables
  • ≤50 mg after 24-h soak in water
  • Length
  • 30 in. (75 cm)
  • Material Size
  • 6
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 0.5 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥15 L
  • Pore Size
  • 0.5 µm
  • Sanitization
  • 30 min with hot water @ 80 °C
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Polygard®
  • Wettability
  • Hydrophilic
CRA553006 Polygard-CR Cartridge Filter 30 in. 0.5 µm Code 5 Silicone 1104 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 5 (2-222) O-rings and spear
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • CRA553006
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Gravimetric Extractables
  • ≤50 mg after 24-h soak in water
  • Length
  • 30 in. (75 cm)
  • Material Size
  • 6
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 0.5 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥15 L
  • Pore Size
  • 0.5 µm
  • Sanitization
  • 30 min with hot water @ 80 °C
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Polygard®
  • Wettability
  • Hydrophilic
CRA553006 Polygard-CR Cartridge Filter 30 in. 0.5 µm Code 5 Silicone 1104 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 5 (2-222) O-rings and spear
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • CRA553006
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Gravimetric Extractables
  • ≤50 mg after 24-h soak in water
  • Length
  • 30 in. (75 cm)
  • Material Size
  • 6
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 0.5 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥15 L
  • Pore Size
  • 0.5 µm
  • Sanitization
  • 30 min with hot water @ 80 °C
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Polygard®
  • Wettability
  • Hydrophilic
CRA573006 Polygard-CR Cartridge Filter 30 in. 0.5 µm Code 7 Silicone 1104 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 7 (2-226) O-rings w/locking-tabs
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • CRA573006
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Gravimetric Extractables
  • ≤50 mg after 24-h soak in water
  • Length
  • 30 in. (75 cm)
  • Material Size
  • 6
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 0.5 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥15 L
  • Pore Size
  • 0.5 µm
  • Sanitization
  • 30 min with hot water @ 80 °C
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Polygard®
  • Wettability
  • Hydrophilic
CRA573006 Polygard-CR Cartridge Filter 30 in. 0.5 µm Code 7 Silicone 1104 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 7 (2-226) O-rings w/locking-tabs
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • CRA573006
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Gravimetric Extractables
  • ≤50 mg after 24-h soak in water
  • Length
  • 30 in. (75 cm)
  • Material Size
  • 6
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 0.5 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥15 L
  • Pore Size
  • 0.5 µm
  • Sanitization
  • 30 min with hot water @ 80 °C
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Polygard®
  • Wettability
  • Hydrophilic
CRA5F4006 Polygard-CR Cartridge Filter 40 in. 0.5 µm Code F 1104 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code F double open end w/flat gaskets
  • Cartridge Nominal Length
  • 40 in. (100 cm)
  • Catalogue Number
  • CRA5F4006
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Gravimetric Extractables
  • ≤50 mg after 24-h soak in water
  • Length
  • 40 in. (100 cm)
  • Material Size
  • 6
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 0.5 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥20 L
  • Pore Size
  • 0.5 µm
  • Sanitization
  • 30 min with hot water @ 80 °C
  • Seal Material
  • Polyethylene (PE)
  • Sterilization
  • Do not autoclave
  • Trade Name
  • Polygard®
  • Wettability
  • Hydrophilic
CRA5F4006 Polygard-CR Cartridge Filter 40 in. 0.5 µm Code F 1104 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code F double open end w/flat gaskets
  • Cartridge Nominal Length
  • 40 in. (100 cm)
  • Catalogue Number
  • CRA5F4006
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Gravimetric Extractables
  • ≤50 mg after 24-h soak in water
  • Length
  • 40 in. (100 cm)
  • Material Size
  • 6
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 0.5 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥20 L
  • Pore Size
  • 0.5 µm
  • Sanitization
  • 30 min with hot water @ 80 °C
  • Seal Material
  • Polyethylene (PE)
  • Sterilization
  • Do not autoclave
  • Trade Name
  • Polygard®
  • Wettability
  • Hydrophilic
CR0154006 Polygard-CR Cartridge Filter 40 in. 1.0 µm Code 5 Silicone 1111 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 5 (2-222) O-rings and spear
  • Cartridge Nominal Length
  • 40 in. (100 cm)
  • Catalogue Number
  • CR0154006
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Gravimetric Extractables
  • ≤50 mg after 24-h soak in water
  • Length
  • 40 in. (100 cm)
  • Material Size
  • 6
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 1.0 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥20 L
  • Pore Size
  • 1.0 µm
  • Sanitization
  • 30 min with hot water @ 80 °C
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Polygard®
  • Wettability
  • Hydrophilic
CR0154006 Polygard-CR Cartridge Filter 40 in. 1.0 µm Code 5 Silicone 1111 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 5 (2-222) O-rings and spear
  • Cartridge Nominal Length
  • 40 in. (100 cm)
  • Catalogue Number
  • CR0154006
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Gravimetric Extractables
  • ≤50 mg after 24-h soak in water
  • Length
  • 40 in. (100 cm)
  • Material Size
  • 6
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 1.0 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥20 L
  • Pore Size
  • 1.0 µm
  • Sanitization
  • 30 min with hot water @ 80 °C
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Polygard®
  • Wettability
  • Hydrophilic
CR0154V06 Polygard-CR Cartridge Filter 40 in. 1.0 µm Code 5 Fluoroelastomer 1111 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 5 (2-222) O-rings and spear
  • Cartridge Nominal Length
  • 40 in. (100 cm)
  • Catalogue Number
  • CR0154V06
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Gravimetric Extractables
  • ≤50 mg after 24-h soak in water
  • Length
  • 40 in. (100 cm)
  • Material Size
  • 6
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 1.0 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥20 L
  • Pore Size
  • 1.0 µm
  • Sanitization
  • 30 min with hot water @ 80 °C
  • Seal Material
  • Fluorocarbon rubber
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Polygard®
  • Wettability
  • Hydrophilic

Overview

Analytical Sample Preparation Membrane Filtration Devices


Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.


Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.


Filter Membranes

Millex® Syringe Filters

Filtration Holders & Accessories



Resources