+852-3069 6950
css@gugent.com.hk
 

We have developed a unique portfolio of consumables, each adapted to the different feed water quality requirements and to your various applications. To maintain your water system’s performance, it’s critical to replace your purification cartridges on time and with genuine ISO 9001-certified parts.

Catalog No. Product Net Price
CW1903S03 Milligard® Cartridge Filter 30 in. Code 0 1.2 µm 926 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 0 (2-222) O-rings
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • CW1903S03
  • Chemistry
  • Mixed Cellulose Esters (MCE)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Device Size
  • 30 in.
  • Diameter
  • 7.1 cm (2.8 in.)
  • Filter Grade
  • Standard Milligard® Media
  • Filtration Area
  • 2.4 m²
  • Format
  • Single Layer
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 50 mg per 10-inch cartridge after 24 hours in water at controlled room temperature.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182. All component materials meet the requirements of the EU framework regulation [1935/2004/EC] regarding materials and articles intended to contact food.
  • Length
  • 30 in. (75 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 3
  • Maximum Differential Pressure, bar (psid)
  • 3.5 bar (50 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 3.5 bar (50 psi) @ 25 °C
  • Media
  • Maximum Differential Pressure, bar (psid)
  • Nominal Pore Size
  • 1.2 µm
  • Non-Fiber Releasing
  • This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥6 L
  • Pore Size
  • 1.2 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 10 autoclave cycles or SIP @ 121 °C for 30 min
  • Support Material
  • Polyester
  • Trade Name
  • Milligard®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
CW1903S03 Milligard® Cartridge Filter 30 in. Code 0 1.2 µm 926 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 0 (2-222) O-rings
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • CW1903S03
  • Chemistry
  • Mixed Cellulose Esters (MCE)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Device Size
  • 30 in.
  • Diameter
  • 7.1 cm (2.8 in.)
  • Filter Grade
  • Standard Milligard® Media
  • Filtration Area
  • 2.4 m²
  • Format
  • Single Layer
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 50 mg per 10-inch cartridge after 24 hours in water at controlled room temperature.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182. All component materials meet the requirements of the EU framework regulation [1935/2004/EC] regarding materials and articles intended to contact food.
  • Length
  • 30 in. (75 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 3
  • Maximum Differential Pressure, bar (psid)
  • 3.5 bar (50 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 3.5 bar (50 psi) @ 25 °C
  • Media
  • Maximum Differential Pressure, bar (psid)
  • Nominal Pore Size
  • 1.2 µm
  • Non-Fiber Releasing
  • This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥6 L
  • Pore Size
  • 1.2 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 10 autoclave cycles or SIP @ 121 °C for 30 min
  • Support Material
  • Polyester
  • Trade Name
  • Milligard®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
CW1973S03 Milligard® Cartridge Filter 30 in. Code 7 1.2 µm 926 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 7 (2-226) O-ring and spear
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • CW1973S03
  • Chemistry
  • Mixed Cellulose Esters (MCE)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Device Size
  • 30 in.
  • Diameter
  • 7.1 cm (2.8 in.)
  • Filter Grade
  • Standard Milligard® Media
  • Filtration Area
  • 2.4 m²
  • Format
  • Single Layer
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 50 mg per 10-inch cartridge after 24 hours in water at controlled room temperature.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182. All component materials meet the requirements of the EU framework regulation [1935/2004/EC] regarding materials and articles intended to contact food.
  • Length
  • 30 in. (75 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 3
  • Maximum Differential Pressure, bar (psid)
  • 3.5 bar (50 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 3.5 bar (50 psi) @ 25 °C
  • Media
  • Maximum Differential Pressure, bar (psid)
  • Nominal Pore Size
  • 1.2 µm
  • Non-Fiber Releasing
  • This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥3 L
  • Pore Size
  • 1.2 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 10 autoclave cycles or SIP @ 121 °C for 30 min
  • Support Material
  • Polyester
  • Trade Name
  • Milligard®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
CW1973S03 Milligard® Cartridge Filter 30 in. Code 7 1.2 µm 926 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 7 (2-226) O-ring and spear
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • CW1973S03
  • Chemistry
  • Mixed Cellulose Esters (MCE)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Device Size
  • 30 in.
  • Diameter
  • 7.1 cm (2.8 in.)
  • Filter Grade
  • Standard Milligard® Media
  • Filtration Area
  • 2.4 m²
  • Format
  • Single Layer
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 50 mg per 10-inch cartridge after 24 hours in water at controlled room temperature.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182. All component materials meet the requirements of the EU framework regulation [1935/2004/EC] regarding materials and articles intended to contact food.
  • Length
  • 30 in. (75 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 3
  • Maximum Differential Pressure, bar (psid)
  • 3.5 bar (50 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 3.5 bar (50 psi) @ 25 °C
  • Media
  • Maximum Differential Pressure, bar (psid)
  • Nominal Pore Size
  • 1.2 µm
  • Non-Fiber Releasing
  • This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥3 L
  • Pore Size
  • 1.2 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 10 autoclave cycles or SIP @ 121 °C for 30 min
  • Support Material
  • Polyester
  • Trade Name
  • Milligard®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
KGEPG3TTT1 Opticap® XLT 30 Millipore Express® SHF Gamma Compatible 0.2 µm 1-1/2 in. TC 927 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Bacterial Retention
  • Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • KGEPG3TTT1
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Capsule
  • Device Material
  • Gamma stable polypropylene/Polysulfone
  • Device Size
  • 30 in.
  • Diameter
  • 10.7 cm (4.2 in.)
  • Filtration Area
  • 1.71 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Housing Material
  • Polypropylene (PP)
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Sanitary Flange
  • Inlet Connection Diameter
  • 1-1/2 in.
  • Inlet to Outlet Width
  • 15.2 cm (6.0 in.)
  • Length
  • 30 in. (75 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 1
  • Maximum Differential Pressure
  • 80 psi (5.5 bar) continuous100 psi (6.9 bar) intermittent
  • Maximum Differential Pressure, bar (psid)
  • Forward: 6.9 bar (100 psid) intermittent @ 25 °C; 5.5 bar (80 psid) @ 25 °C; 1.0 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C, intermittent
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 6.9 bar (100 psi) intermittent @ 25 °C; 5.5 bar (80 psi) @ 25 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Millipore Express® SHF
  • Non-Fiber Releasing
  • This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Outlet Connection
  • Sanitary Flange
  • Outlet Connection Diameter
  • 1-1/2 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥4.5 L
  • Pore Size
  • 0.2 µm
  • Seal Material
  • Silicone (SI)
  • Sterility
  • Gamma
  • Sterilization
  • Gamma compatible to 45 kGy; 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
  • Support Material
  • Polyester
  • Trade Name
  • Millipore Express®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Polypropylene (PP)
  • Wettability
  • Hydrophilic
  • Width
  • 15.2 cm (6.0 in.)
KGEPG3TTT1 Opticap® XLT 30 Millipore Express® SHF Gamma Compatible 0.2 µm 1-1/2 in. TC 927 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Bacterial Retention
  • Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • KGEPG3TTT1
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Capsule
  • Device Material
  • Gamma stable polypropylene/Polysulfone
  • Device Size
  • 30 in.
  • Diameter
  • 10.7 cm (4.2 in.)
  • Filtration Area
  • 1.71 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Housing Material
  • Polypropylene (PP)
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Sanitary Flange
  • Inlet Connection Diameter
  • 1-1/2 in.
  • Inlet to Outlet Width
  • 15.2 cm (6.0 in.)
  • Length
  • 30 in. (75 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 1
  • Maximum Differential Pressure
  • 80 psi (5.5 bar) continuous100 psi (6.9 bar) intermittent
  • Maximum Differential Pressure, bar (psid)
  • Forward: 6.9 bar (100 psid) intermittent @ 25 °C; 5.5 bar (80 psid) @ 25 °C; 1.0 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C, intermittent
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 6.9 bar (100 psi) intermittent @ 25 °C; 5.5 bar (80 psi) @ 25 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Millipore Express® SHF
  • Non-Fiber Releasing
  • This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Outlet Connection
  • Sanitary Flange
  • Outlet Connection Diameter
  • 1-1/2 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥4.5 L
  • Pore Size
  • 0.2 µm
  • Seal Material
  • Silicone (SI)
  • Sterility
  • Gamma
  • Sterilization
  • Gamma compatible to 45 kGy; 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
  • Support Material
  • Polyester
  • Trade Name
  • Millipore Express®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Polypropylene (PP)
  • Wettability
  • Hydrophilic
  • Width
  • 15.2 cm (6.0 in.)
P3B030D01 Pellicon® 3 Cassette with Biomax® 30 kDa Membrane, D screen, 0.11 m² 927 
Add to Cart
  • Catalogue Number
  • P3B030D01
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Cassette
  • Device Material
  • Polypropylene end cap
  • Filter Type
  • Ultrafiltration
  • Filtration Area
  • 0.11 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m2after 24 hours in water at controlled room temperature.
  • Height
  • 2.34 cm (0.92 in.)
  • Hold-up Volume
  • 23 mL in feed channel
  • Key Applications
  • Protein ConcentrationPurification and Buffer Exchange
  • Length
  • 20.6 cm (8.1 in.)
  • Material Size
  • 1
  • Maximum Inlet Pressure, bar (psi)
  • 6.9 bar (100 psi)
  • Media
  • Biomax®
  • Membrane Area
  • 0.11 m²
  • NMWL
  • 30 kDa
  • pH Range
  • pH2 – pH14
  • Recirculation Rate
  • 4–6 L/min per m²
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type D screen (coarse screen for high viscosity)
  • Seal Material
  • Thermoplastic Elastomer (TPE)
  • Trade Name
  • Pellicon®
  • Volume
  • 23 mL in feed channel
  • Width
  • 5.6 cm (2.2 in.)
CR0103T06 Polygard-CR Cartridge Filter 30 in. 1.0 µm Code 0 PTFE-encapsulated Fluoroelastomer 935 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 0 (2-222) O-rings
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • CR0103T06
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Gravimetric Extractables
  • ≤50 mg after 24-h soak in water
  • Length
  • 30 in. (75 cm)
  • Material Size
  • 6
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 1.0 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥15 L
  • Pore Size
  • 1.0 µm
  • Sanitization
  • 30 min with hot water @ 80 °C
  • Seal Material
  • Polytetrafluoroethylene (PTFE)
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Polygard®
  • Wettability
  • Hydrophilic
CR0153T06 Polygard-CR Cartridge Filter 30 in. 1.0 µm Code 5 PTFE-encapsulated Fluoroelastomer 935 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 5 (2-222) O-rings and spear
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • CR0153T06
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Gravimetric Extractables
  • ≤50 mg after 24-h soak in water
  • Length
  • 30 in. (75 cm)
  • Material Size
  • 6
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 1.0 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥15 L
  • Pore Size
  • 1.0 µm
  • Sanitization
  • 30 min with hot water @ 80 °C
  • Seal Material
  • Polytetrafluoroethylene (PTFE)
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Polygard®
  • Wettability
  • Hydrophilic
CWLC72S03 Milligard® Low Protein Binding Cartridge Filter 20 in. Code 7 0.5 µm 940 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 7 (2-226) O-ring and spear
  • Cartridge Nominal Length
  • 20 in. (50 cm)
  • Catalogue Number
  • CWLC72S03
  • Chemistry
  • Low Protein-Binding Mixed Cellulose Esters (MCE)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Device Size
  • 20 in.
  • Diameter
  • 7.1 cm (2.8 in.)
  • Filter Grade
  • Low Protein Binding Milligard® Media
  • Filtration Area
  • 1.38 m²
  • Format
  • Double Layer
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 350 mg per 10-inch cartridge after a 5 L flush and 24 hours in water at controlled room temperature.
  • Length
  • 20 in. (50 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 3
  • Maximum Differential Pressure, bar (psid)
  • 3.5 bar (50 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 3.5 bar (50 psi) @ 25 °C
  • Media
  • Maximum Differential Pressure, bar (psid)
  • Nominal Pore Size
  • 1.2 / 0.5 µm
  • Non-Fiber Releasing
  • This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥6 L
  • Pore Size
  • 1.2 / 0.5 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 10 autoclave cycles or SIP @ 121 °C for 30 min
  • Support Material
  • Polyester
  • Trade Name
  • Milligard®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.

Overview

Analytical Sample Preparation Membrane Filtration Devices


Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.


Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.


Filter Membranes

Millex® Syringe Filters

Filtration Holders & Accessories



Resources