We have developed a unique portfolio of consumables, each adapted to the different feed water quality requirements and to your various applications. To maintain your water system’s performance, it’s critical to replace your purification cartridges on time and with genuine ISO 9001-certified parts.
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Code
Code 7 (2-226) O-ring and spear
Cartridge Nominal Length
30 in.
Catalogue Number
CWSC73S03
Chemistry
Mixed Cellulose Esters (MCE)
Device Configuration
Cartridge
Device Material
Polypropylene
Device Size
30 in.
Diameter
7.1 cm (2.8 in.)
Filter Grade
Standard Milligard® Media
Filtration Area
2.07 m²
Format
Double Layer
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 50 mg per 10-inch cartridge after 24 hours in water at controlled room temperature.
Indirect Food Additive
All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182. All component materials meet the requirements of the EU framework regulation [1935/2004/EC] regarding materials and articles intended to contact food.
Length
30 in.
Material Package
Double Easy-Open bag
Material Size
3
Maximum Differential Pressure, bar (psid)
3.5 bar (50 psid) @ 25 °C
Maximum Inlet Pressure, bar (psi)
3.5 bar (50 psi) @ 25 °C
Media
Maximum Differential Pressure, bar (psid)
Nominal Pore Size
1.2 / 0.5 µm
Non-Fiber Releasing
This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥3 L
Pore Size
1.2 / 0.5 µm
Seal Material
Silicone (SI)
Sterilization
10 autoclave cycles or SIP @ 121 °C for 30 min
Support Material
Polyester
Trade Name
Milligard®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Code
Code 0 (2-222) O-rings
Cartridge Nominal Length
30 in. (75 cm)
Catalogue Number
CWSS03S03
Chemistry
Mixed Cellulose Esters (MCE)
Device Configuration
Cartridge
Device Material
Polypropylene
Device Size
30 in.
Diameter
7.1 cm (2.8 in.)
Filter Grade
Standard Milligard® Media
Filtration Area
2.07 m²
Format
Double Layer
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 50 mg per 10-inch cartridge after 24 hours in water at controlled room temperature.
Indirect Food Additive
All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182. All component materials meet the requirements of the EU framework regulation [1935/2004/EC] regarding materials and articles intended to contact food.
Length
30 in. (75 cm)
Material Package
Double Easy-Open bag
Material Size
3
Maximum Differential Pressure, bar (psid)
3.5 bar (50 psid) @ 25 °C
Maximum Inlet Pressure, bar (psi)
3.5 bar (50 psi) @ 25 °C
Media
Maximum Differential Pressure, bar (psid)
Nominal Pore Size
0.5 / 0.2 µm
Non-Fiber Releasing
This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥12 L
Pore Size
0.5 / 0.2 µm
Seal Material
Silicone (SI)
Sterilization
10 autoclave cycles or SIP @ 121 °C for 30 min
Support Material
Polyester
Trade Name
Milligard®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Code
Code 0 (2-222) O-rings
Cartridge Nominal Length
30 in. (75 cm)
Catalogue Number
CWSS03S03
Chemistry
Mixed Cellulose Esters (MCE)
Device Configuration
Cartridge
Device Material
Polypropylene
Device Size
30 in.
Diameter
7.1 cm (2.8 in.)
Filter Grade
Standard Milligard® Media
Filtration Area
2.07 m²
Format
Double Layer
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 50 mg per 10-inch cartridge after 24 hours in water at controlled room temperature.
Indirect Food Additive
All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182. All component materials meet the requirements of the EU framework regulation [1935/2004/EC] regarding materials and articles intended to contact food.
Length
30 in. (75 cm)
Material Package
Double Easy-Open bag
Material Size
3
Maximum Differential Pressure, bar (psid)
3.5 bar (50 psid) @ 25 °C
Maximum Inlet Pressure, bar (psi)
3.5 bar (50 psi) @ 25 °C
Media
Maximum Differential Pressure, bar (psid)
Nominal Pore Size
0.5 / 0.2 µm
Non-Fiber Releasing
This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥12 L
Pore Size
0.5 / 0.2 µm
Seal Material
Silicone (SI)
Sterilization
10 autoclave cycles or SIP @ 121 °C for 30 min
Support Material
Polyester
Trade Name
Milligard®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Code
Code 5 (2-222) O-rings and spear
Cartridge Nominal Length
30 in. (75 cm)
Catalogue Number
CWSS53S03
Chemistry
Mixed Cellulose Esters (MCE)
Device Configuration
Cartridge
Device Material
Polypropylene
Device Size
30 in.
Diameter
7.1 cm (2.8 in.)
Filter Grade
Standard Milligard® Media
Filtration Area
2.07 m²
Format
Double Layer
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 50 mg per 10-inch cartridge after 24 hours in water at controlled room temperature.
Indirect Food Additive
All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182. All component materials meet the requirements of the EU framework regulation [1935/2004/EC] regarding materials and articles intended to contact food.
Length
30 in. (75 cm)
Material Package
Double Easy-Open bag
Material Size
3
Maximum Differential Pressure, bar (psid)
3.5 bar (50 psid) @ 25 °C
Maximum Inlet Pressure, bar (psi)
3.5 bar (50 psi) @ 25 °C
Media
Maximum Differential Pressure, bar (psid)
Nominal Pore Size
0.5 / 0.2 µm
Non-Fiber Releasing
This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Pore Size
0.5 / 0.2 µm
Seal Material
Silicone (SI)
Sterilization
10 autoclave cycles or SIP @ 121 °C for 30 min
Support Material
Polyester
Trade Name
Milligard®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Code
Code 5 (2-222) O-rings and spear
Cartridge Nominal Length
30 in. (75 cm)
Catalogue Number
CWSS53S03
Chemistry
Mixed Cellulose Esters (MCE)
Device Configuration
Cartridge
Device Material
Polypropylene
Device Size
30 in.
Diameter
7.1 cm (2.8 in.)
Filter Grade
Standard Milligard® Media
Filtration Area
2.07 m²
Format
Double Layer
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 50 mg per 10-inch cartridge after 24 hours in water at controlled room temperature.
Indirect Food Additive
All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182. All component materials meet the requirements of the EU framework regulation [1935/2004/EC] regarding materials and articles intended to contact food.
Length
30 in. (75 cm)
Material Package
Double Easy-Open bag
Material Size
3
Maximum Differential Pressure, bar (psid)
3.5 bar (50 psid) @ 25 °C
Maximum Inlet Pressure, bar (psi)
3.5 bar (50 psi) @ 25 °C
Media
Maximum Differential Pressure, bar (psid)
Nominal Pore Size
0.5 / 0.2 µm
Non-Fiber Releasing
This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Pore Size
0.5 / 0.2 µm
Seal Material
Silicone (SI)
Sterilization
10 autoclave cycles or SIP @ 121 °C for 30 min
Support Material
Polyester
Trade Name
Milligard®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Code
Code 7 (2-226) O-ring and spear
Cartridge Nominal Length
30 in. (75 cm)
Catalogue Number
CWSS73S03
Chemistry
Mixed Cellulose Esters (MCE)
Device Configuration
Cartridge
Device Material
Polypropylene
Device Size
30 in.
Diameter
7.1 cm (2.8 in.)
Filter Grade
Standard Milligard® Media
Filtration Area
2.07 m²
Format
Double Layer
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 50 mg per 10-inch cartridge after 24 hours in water at controlled room temperature.
Indirect Food Additive
All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182. All component materials meet the requirements of the EU framework regulation [1935/2004/EC] regarding materials and articles intended to contact food.
Length
30 in. (75 cm)
Material Package
Double Easy-Open bag
Material Size
3
Maximum Differential Pressure, bar (psid)
3.5 bar (50 psid) @ 25 °C
Maximum Inlet Pressure, bar (psi)
3.5 bar (50 psi) @ 25 °C
Media
Maximum Differential Pressure, bar (psid)
Nominal Pore Size
0.5 / 0.2 µm
Non-Fiber Releasing
This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥9 L
Pore Size
0.5 / 0.2 µm
Seal Material
Silicone (SI)
Sterilization
10 autoclave cycles or SIP @ 121 °C for 30 min
Support Material
Polyester
Trade Name
Milligard®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Code
Code 7 (2-226) O-ring and spear
Cartridge Nominal Length
30 in. (75 cm)
Catalogue Number
CWSS73S03
Chemistry
Mixed Cellulose Esters (MCE)
Device Configuration
Cartridge
Device Material
Polypropylene
Device Size
30 in.
Diameter
7.1 cm (2.8 in.)
Filter Grade
Standard Milligard® Media
Filtration Area
2.07 m²
Format
Double Layer
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 50 mg per 10-inch cartridge after 24 hours in water at controlled room temperature.
Indirect Food Additive
All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182. All component materials meet the requirements of the EU framework regulation [1935/2004/EC] regarding materials and articles intended to contact food.
Length
30 in. (75 cm)
Material Package
Double Easy-Open bag
Material Size
3
Maximum Differential Pressure, bar (psid)
3.5 bar (50 psid) @ 25 °C
Maximum Inlet Pressure, bar (psi)
3.5 bar (50 psi) @ 25 °C
Media
Maximum Differential Pressure, bar (psid)
Nominal Pore Size
0.5 / 0.2 µm
Non-Fiber Releasing
This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥9 L
Pore Size
0.5 / 0.2 µm
Seal Material
Silicone (SI)
Sterilization
10 autoclave cycles or SIP @ 121 °C for 30 min
Support Material
Polyester
Trade Name
Milligard®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.
Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.