+852-3069 6950
css@gugent.com.hk
 

Agilent Inductively Coupled Plasma Mass Spectrometry (ICP-MS) is available in single quadrupole and triple quadrupole configurations. Our single quadrupole ICP-MS address the range of typical ICP-MS measurements from routine, regulated analysis to advanced research and demanding applications. Our triple quadrupole ICP-MS will give you the confidence of knowing you can resolve problematic interferences – even in your most difficult samples – delivering results you know you can trust.

Catalog No. Product Net Price
AGIL5043-0055 ISIS3, Replacement collapsible ferrules, PCTFE, for 1/8 inch tubing, 10/pk. Polychlorotrifluoroethylene ferrule suits flangeless tube end fitting. Suitable for ISIS3 used with Agilent 7800, 7850, 7900 and 8900 ICP-MS 43 
Add to Cart
  • UNSPSC Code
  • 40141616
  • Material
  • PCTFE
  • Where Used
  • ISIS 3
G8411-67111 ISIS 3 Valve rotor seal replacement set. Includes rotor seal for ISIS valve and hex key wrench, 7/64 inch 151 
Add to Cart
  • UNSPSC Code
  • 41113000
G8411-67118 ISIS 3 Sample loop tubing, PFA, 2.18 mm id, 1/8 inch od, 5 m. For manual assembly of wide bore sample loop. Requires black flangless tube fitting and ferrule (5023-1527). Used on Agilent 7900, 8900 with ISIS 3 switching valve 75 
Add to Cart
  • Inner Diameter (ID)
  • 2.18 mm
  • Length
  • 5 m
  • UNSPSC Code
  • 41113000
  • Chemical Compatibility
  • Aqueous Organic solvents Strong acids
  • Outer Diameter (OD)
  • 3.175 mm
  • Tubing Material
  • PFA
  • Tubing OD
  • 0.125 in
  • Where Used
  • ISIS 3
G8411-80119 ISIS3, Nut, PEEK, for pump, 1ea. Suitable for ISIS3 used with Agilent 7800, 7850, 7900 and 8900 ICP-MS 201 
Add to Cart
  • UNSPSC Code
  • 41113000
  • Material
  • PEEK
  • Where Used
  • ISIS 3
G8411-80121 ISIS 3 Stator, for 7 port, 2 position injection valve 1676 
Add to Cart
  • UNSPSC Code
  • 41113000
G3138-65136 ISIS cyclone chamber, for hydride generation accessory. Suitable for use with Agilent 7700 and 8800 with integrated sample introduction system (ISIS) Special offer 
Add to Cart
  • UNSPSC Code
  • 41115411
AGIL5064-8016 ISIS-DS, Sample tubing, PTFE, 0.8 mm id, 1.6 mm od, 5 m length. Suitable for ISIS-DS used with Agilent 7500 ICP-MS 91 
Add to Cart
  • Inner Diameter (ID)
  • 0.8 mm
  • Length
  • 5 m
  • UNSPSC Code
  • 41115411
  • Chemical Compatibility
  • Aqueous Organic solvents Strong acids
  • Outer Diameter (OD)
  • 1.6 mm
  • Where Used
  • ISIS-DS
AGIL5064-8020 ISIS-DS, Sample tubing, PTFE, 2 mm id, 3 mm od, 5 m length. Suitable for ISIS-DS used with Agilent 7500 ICP-MS 66 
Add to Cart
  • Inner Diameter (ID)
  • 2 mm
  • Length
  • 5 m
  • UNSPSC Code
  • 41115411
  • Chemical Compatibility
  • Aqueous Organic solvents Strong acids
  • Outer Diameter (OD)
  • 3 mm
  • Where Used
  • ISIS-DS
AGIL5064-8029 ISIS Tubing, spiral, 5 m. Suitable for use with Agilent 7500, 7700, 8800 with integrated sample introduction system with discrete sampling (ISIS-DS) 39 
Add to Cart
  • Length
  • 5 m
  • UNSPSC Code
  • 41115411
  • Fittings
  • None
  • Where Used
  • ISIS-DS
AGIL5064-8032 ISIS-DS Wrench for valve. Used for maintenance of Agilent ICP-MS integrated sample introduction system with discrete sampling (ISIS-DS) 32 
Add to Cart
  • UNSPSC Code
  • 41115411

Overview

ICP-MS system operates with an ICP-MS Nebulizer, in which a high velocity Argon gas stream meets a liquid stream causing filmwise breakup of the solution into a fine aerosol. The aerosol particle size should ideally be sub-10µm with a narrow particle size distribution to achieve efficient atomization and ionization. Agilent offers a comprehensive range of ICP-MS nebulizers and supplies to solve any ICP-MS analysis challenge.

The portfolio includes standard glass concentric nebulizer (MicroMist), quartz and inert PFA nebulizers (MicroFlow and C-Flow), as well as robust Mira Mist PEEK or PTFE for high TDS samples and low-flow self-aspirating or total consumption nebulizers for your clinical or limited volume samples. ICP-MS nebulizer support is provided with a full range of accessories for all models including nebulizer cleaning tools.


The ICP torch is used to form, shape, and sustain an argon plasma which atomizes and ionizes the sample aerosol. Agilent ICP-MS Torches with Shield Torch System (STS) provide precise ion energy control, ensuring high sensitivity and stability, even in cool plasma mode for effective interference removal (ArO+).

Our portfolio is comprised of a wide range of ICP torches for your specific ICP-MS configuration. One-piece quartz torches offer the best stability and ease of use. The large 2.5mm injector on the standard torch gives maximum robustness and lowest matrix interferences for the best plasma stability. Single-piece torches with narrow bore injectors (1.0mm or 1.5 mm) are designed for use with organic solvents, to reduce plasma loading and improve plasma stability. Optional semi-demountable quartz torches with removable platinum or sapphire injectors are also available for use with the PFA inert sample introduction kit.


Resources