Agilent Inductively Coupled Plasma Mass Spectrometry (ICP-MS) is available in single quadrupole and triple quadrupole configurations. Our single quadrupole ICP-MS address the range of typical ICP-MS measurements from routine, regulated analysis to advanced research and demanding applications. Our triple quadrupole ICP-MS will give you the confidence of knowing you can resolve problematic interferences – even in your most difficult samples – delivering results you know you can trust.

Catalog No. Product Net Price
G3285-80023 Tube, connector, perfluoroalkoxy (PFA), for inert kit, without gas port, suits inert sample introduction kit with Agilent 7500 series ICP-MS 422 
Add to Cart
  • UNSPSC Code
  • 41115411
G3285-80037 Injector, platinum, 1.5 mm id, with Oxygen gas port, for PFA inert kit, for semiconductor organic solvent analysis. Replacement for PFA inert sample introduction kit with Agilent 7500 ICP-MS Special offer 
Add to Cart
  • UNSPSC Code
  • 41115411
  • Chemical Compatibility
  • Aqueous Organic solvents Strong acids
  • Type
  • Inert
G4912-80013 Semi-demountable inert torch for PFA inert kit, used with 1.5mm id sapphire or platinum injector for organic applications. Replacement outer quartz torch body for PFA inert sample introduction kit suitable for Agilent 7500, 7700, 7800, 7850, 7900, 8800, 8 1187 
Add to Cart
  • UNSPSC Code
  • 41115411
  • Chemical Compatibility
  • Aqueous Organic solvents Strong acids
  • Type
  • Inert
G8014-60023 Top seal for fully and semidemountable torches, 3/pk. For use with Agilent 5100/5110 and 5800/5900 ICP-OES instruments. This seals the outer-tube set to the torch base. 18 
Add to Cart
AGIL5042-4799 Peristaltic pump tubing, recommended for spray chamber drain for xylene analysis, 1 pc. Fluran®, 3-stop, yellow/blue tabs, 1.52 mm id, recommended for organic samples in Xylene matrix 213 
Add to Cart
  • Inner Diameter (ID)
  • 1.52 mm
  • UNSPSC Code
  • 41115720
  • Chemical Compatibility
  • Organic solvents
  • Flared
  • No
  • Number of Stops
  • 3
  • Stop Color
  • Yellow/Blue
  • Tubing Material
  • Fluran
AGIL5064-8101 Obsolete. Replaced by 5005-0023. Replaced by Easy-fit tubing with 2-stopper optimum length to avoid trimming and expedite sample and ISTD uptake. Special offer 
Add to Cart
  • Inner Diameter (ID)
  • 0.76 mm
  • UNSPSC Code
  • 40183000
  • Chemical Compatibility
  • Aqueous HF acid Strong acids
  • Flared
  • Yes
  • Number of Stops
  • 3
  • Stop Color
  • Black/Black
  • Tubing Material
  • PVC
G1820-65105 Sample tubing, PFA, 0.5mm ID, 1.6mm OD, 5m. Standard sample uptake tubing used with Agilent ICP-MS. Replace when tubing is bent, damaged, or when there are serious memory effects in the sample introduction area. 76 
Add to Cart
  • Inner Diameter (ID)
  • 0.5 mm
  • Length
  • 5 m
  • UNSPSC Code
  • 41115411
  • Chemical Compatibility
  • Aqueous HF acid Organic solvents Strong acids
  • Outer Diameter (OD)
  • 1.6 mm
  • Where Used
  • Sample uptake
G1820-65217 Peristaltic pump tubing, Silicone, 3-stop, white/white tabs, 1.02 mm id, 1 pack of 6 pcs. Recommended for high purity analysis when not using self-aspirating nebulizer. 201 
Add to Cart
  • Inner Diameter (ID)
  • 1.02 mm
  • UNSPSC Code
  • 41115411
  • Chemical Compatibility
  • Aqueous HF acid Strong acids
  • Flared
  • No
  • Material
  • Peroxide cured Silicone
  • Number of Stops
  • 3
  • Stop Color
  • White/White
  • Tubing Material
  • Silicone
G1820-65478 Sample tubing, PFA, 0.3 mm id, 1.6 mm od, 3 m, for online internal standard addition. Standard for all Agilent ICP-MS used with ISTD T-joint. Replace when tubing is bent, damaged, or when there is an issue with ISTD delivery 73 
Add to Cart
  • Inner Diameter (ID)
  • 0.3 mm
  • Length
  • 3 m
  • UNSPSC Code
  • 41115411
  • Chemical Compatibility
  • Aqueous HF acid Organic solvents Strong acids
  • Outer Diameter (OD)
  • 1.6 mm
  • Where Used
  • Internal standard (ISTD)
G1820-65527 ISIS-DS, Sample tubing, PFA with PEEK guide, 0.2 mm id, 1.6 mm od, 70 cm, 5/pk. Suitable for ISIS-DS used with Agilent 7500 ICP-MS 615 
Add to Cart
  • Inner Diameter (ID)
  • 0.2 mm
  • Length
  • 70 cm
  • UNSPSC Code
  • 41115411
  • Chemical Compatibility
  • Aqueous Organic solvents Strong acids
  • Material
  • PFA
  • Outer Diameter (OD)
  • 1.6 mm
  • Where Used
  • ISIS-DS

Overview

ICP-MS system operates with an ICP-MS Nebulizer, in which a high velocity Argon gas stream meets a liquid stream causing filmwise breakup of the solution into a fine aerosol. The aerosol particle size should ideally be sub-10µm with a narrow particle size distribution to achieve efficient atomization and ionization. Agilent offers a comprehensive range of ICP-MS nebulizers and supplies to solve any ICP-MS analysis challenge.

The portfolio includes standard glass concentric nebulizer (MicroMist), quartz and inert PFA nebulizers (MicroFlow and C-Flow), as well as robust Mira Mist PEEK or PTFE for high TDS samples and low-flow self-aspirating or total consumption nebulizers for your clinical or limited volume samples. ICP-MS nebulizer support is provided with a full range of accessories for all models including nebulizer cleaning tools.


The ICP torch is used to form, shape, and sustain an argon plasma which atomizes and ionizes the sample aerosol. Agilent ICP-MS Torches with Shield Torch System (STS) provide precise ion energy control, ensuring high sensitivity and stability, even in cool plasma mode for effective interference removal (ArO+).

Our portfolio is comprised of a wide range of ICP torches for your specific ICP-MS configuration. One-piece quartz torches offer the best stability and ease of use. The large 2.5mm injector on the standard torch gives maximum robustness and lowest matrix interferences for the best plasma stability. Single-piece torches with narrow bore injectors (1.0mm or 1.5 mm) are designed for use with organic solvents, to reduce plasma loading and improve plasma stability. Optional semi-demountable quartz torches with removable platinum or sapphire injectors are also available for use with the PFA inert sample introduction kit.


Resources